• 제목/요약/키워드: SCREEN TEST

검색결과 627건 처리시간 0.027초

오일교환경보 알고리즘 및 표시장치 개발 (Development of Oil Change Warning Algorithm and Display Device)

  • 전상명
    • Tribology and Lubricants
    • /
    • 제30권3호
    • /
    • pp.168-176
    • /
    • 2014
  • This paper presents an engine oil change warning algorithm based on the test results of a small dip-stick-gage-type engine-oil-deterioration-detection sensor, software to realize the algorithm and a display device to apply the software. The algorithm determines the engine oil deterioration condition from the rate of change in the dielectric constant based on the average measured capacitance at $80^{\circ}C$ after the engine stops. The rate of change in the dielectric constant at the time for oil change correlates with the time that one of recommended warning limits for engine oil physical properties such as TAN (Total Acid Number), TBN (Total Base Number) and viscosity is first reached. At this point, a warning signal for oil change appears on the display device like a smart-phone or individual display device. The frames of smartphone app have three stages. The user can directly input all of the thresholds into the frame of the smartphone app. The screen of the display device comprises one frame for each warning signature with the related message. The user can input the thresholds to the device through a USB cable connected to a personal computer.

Ex Vivo Permeability Characteristics of Porcine Buccal Mucosa to Drugs with Various Polarity

  • Lee, Jae-Hwi;Lee, Yoon-Jin;Yoon, Mi-Kyeong;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권2호
    • /
    • pp.71-74
    • /
    • 2005
  • The aim of this study was to analyze characteristics of the barrier function of excised porcine buccal mucosa to the test compounds, estradiol, propranolol HCI, melatonin, and mannitol with a wide range of partition coefficient values. The permeability of melatonin was measured through frozen, stored, and fresh porcine buccal mucosa to examine the impact of storage conditions on the permeability of porcine buccal mucosa. The results demonstrated that the ex vivo permeability of the porcine buccal mucosa was greater for more lipophilic solutes, which was consistent with a series of molecules transported by passive transepithelial diffusion. The melatonin permeation profiles through frozen, stored, and fresh mucosa illustrated that damage was incurred by the freezing process of the mucosal tissue, leading to loss of the barrier function and thereby an increased permeation coefficient. It can be observed that the influence of compound lipophilicity on the association of the compounds with buccal mucosa was clear. The relationship between permeation coefficient and Log P values for the four compounds investigated demonstrated a proportional relationship, further confirming the importance of the lipophilicity of a compound to permeate the buccal mucosa. These results showed that the ex vivo porcine buccal mucosa model is a suitable tool to screen oral mucosal permeability.

Computer Program을 이용한 화학물질의 환경동태 예측 (Prediction of Environmental Fate of Certain Chemicals Using Computer Simulation Programs)

  • 김균;김용화
    • 한국환경농학회지
    • /
    • 제12권1호
    • /
    • pp.69-80
    • /
    • 1993
  • Environmental hazards of a chemical could be assessed by two different approaches : toxicity test and assessment of exposure potentials to human and environmental organisms. For the prediction of environmental fate of chemicals three available computer programs were compared each other and were verified. The results obtained by using these computer programs, PCHEM, EXAMS, and E4CHEM were summarized as follows. The estimated octanol/water partition coefficients by PCHEM were similar to the experimental values in the literature. But the other factors, water solubility and vapor pressure were different from the data in the literature. The simulation results of selected compounds by EXAMS showed similar tendency to the literature results of model field environment. Therefore, this computer program could be utilized to predict the environmental fate of chemicals. E4CHEM program is very simple and this program could predict the ultimate environmental fate of stable chemicals by input of two or three parameters. However, the validity should further be verified in the future field study using more compounds. It is suggested that these approaches could be fully utilized by understanding their limitations to predict the environmental fate of new chemicals under development, to screen the potential environmental pollutants among chemicals already-in use, and to devise measures to minimize the hazards to the environment.

  • PDF

삼점 신호 평균기법에 의한 요속신호의 잡음 축소 기법 (Noise Reduction Technique by Three-Points Ensemble Averaging in Uroflowmetry)

  • 최성수;이인광;이상봉;박준오;이수옥;차은종;김경아
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1638-1643
    • /
    • 2009
  • Uroflowmetry is a convenient clinical test to screen the benign prostatic hyperplasia(BPH) common in the aged men. A load cell is located beneath the urine container to measure the weight of urine. However, it is sensitive to the impact applied on the bottom of the container by the urine stream, which could be a noise source lowering the reliability of the system. With this aim, our study proposed a noise reduction technique by computing ensemble average of the weighted signals that were acquired from three-load cells forming a regular triangle beneath the urine container. Simulated urination experiment was performed with three different collection methods, all of which demonstrated significant noise reduction by ensemble averaging. Furthermore, the best results can be obtained without any special urine collection devices. Thus, our novel method can be usefully applied to uroflowmetry for enhancing measurement in terms of accuracy and reliability.

이미지 피드백에 의한 스카라 로봇의 실시간 제어 (A Real-Time Control of SCARA Robot Based Image Feedback)

  • 이우송;구영목;심현석;이상훈;김동엽
    • 한국산업융합학회 논문집
    • /
    • 제17권2호
    • /
    • pp.54-60
    • /
    • 2014
  • The equipment of SCARA robot in processing and assembly lines has rapidly increased. In order to achieve high productivity and flexibility, it becomes very important to develop the visual feedback control system with Off-Line Programming System(OLPS). We can save much efforts and time in adjusting robots to newly defined workcells by using OLPS. A proposed visual calibration scheme is based on position-based visual feedback. The calibration program firstly generates predicted images of objects in an assumed end-effector position. The process to generate predicted images consists of projection to screen-coordinates, visible range test, and construction of simple silhouette figures. Then, camera images acquired are compared with predicted ones for updating position and orientation data. Computation of error is very simple because the scheme is based on perspective projection, which can be also expanded to experimental results. Computation time can be extremely reduced because the proposed method does not requirethe precise calculation of tree-dimensional object data and image Jacobian.

수경재배용 배양액의 이온성분 분석을 위한 고체형 센서 모듈 개발 (Development of a Solid State Ion Sensor Module for Analysis of Hydroponic Nutrients)

  • 김기영;이상봉;장영창
    • Journal of Biosystems Engineering
    • /
    • 제32권5호
    • /
    • pp.348-353
    • /
    • 2007
  • A solid state ion sensor module has been developed and evaluated for hydroponic nutrients analysis. The sensor module consisted of five ion-selective electrodes (ISE) fabricated by screen-printing technology. The electrochemical responses of ion sensors for nitrate, ammonium, potassium, calcium, and pH were measured with specially designed 7-channel low voltage signal transducers. The analytical characteristics of the sensors were comparable with those of conventional ISE sensors. The solid state ion sensors exhibit linear relationships over five concentration decades. Detection limit of the sensors were $5.6{\times}10^{-5}{\sim}1.6{\times}10^{-7}M$ depends on ions. Performance test results showed that relative errors of measured ion concentrations were less than 5% for $NO_3{^-},\;K^+,\;Ca^{2+}$ ion, and pH. The concentration of $NO_3{^-},\;NH_4{^+},\;K^+,\;Ca^{2+}$, and pH ion in standard solution and nutrient solutions could be determined by direct potentiometric measurements without any conditioning before measurements.

Racial and Socioeconomic Disparities in Malignant Carcinoid Cancer Cause Specific Survival: Analysis of the Surveillance, Epidemiology and End Results National Cancer Registry

  • Cheung, Rex
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7117-7120
    • /
    • 2013
  • Background: This study hypothesized living in a poor neighborhood decreased the cause specific survival in individuals suffering from carcinoid carcinomas. Surveillance, Epidemiology and End Results (SEER) carcinoid carcinoma data were used to identify potential socioeconomic disparities in outcome. Materials and Methods: This study analyzed socioeconomic, staging and treatment factors available in the SEER database for carcinoid carcinomas. The Kaplan-Meier method was used to analyze time to events and the Kolmogorov-Smirnov test to compare survival curves. The Cox proportional hazard method was employed for multivariate analysis. Areas under the receiver operating characteristic curves (ROCs) were computed to screen the predictors for further analysis. Results: There were 38,546 patients diagnosed from 1973 to 2009 included in this study. The mean follow up time (S.D.) was 68.1 (70.7) months. SEER stage was the most predictive factor of outcome (ROC area of 0.79). 16.4% of patients were un-staged. Race/ethnicity, rural urban residence and county level family income were significant predictors of cause specific survival on multivariate analysis, these accounting for about 5% of the difference in actuarial cause specific survival at 20 years of follow up. Conclusions: This study found poorer cause specific survival of carcinoid carcinomas of individuals living in poor and rural neighborhoods.

비압축 HD급 영상 및 고음질 음성 출력을 지원하는 휴대용 게임기 구현 (Development of portable game device with uncompressed HD video and high quality sound output)

  • 이충희;이종훈;정우영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.391-393
    • /
    • 2006
  • In this paper, we develop a portable game device with uncompressed HD video and high quality sound output. Portable game devices support not only game function but also various complex functions recently. It especially supports TV-Out port to play realistic game, connecting a large screen display device. But the video and audio output signals of conventional TV-out port have the low performance and these signals are analog output. So, it is difficult that the users enjoy realistic game with benefit of high resolution digital TV. We propose the game device output with uncompressed digital signal, which has no delay of video/audio signal, also has strong immunity to external noise. Since it supports a high resolution video and high quality sound, users can playa realistic game. First, we implement the HDMI to the game device and we test reliability with the various resolutions video inputs and audio inputs. The proposed method can be applied multimedia devices requiring high performance output function as well as portable devices.

  • PDF

스마트 디바이스를 위한 3D 파라메트릭 CAD 시스템 (A 3D Parametric CAD System for Smart Devices)

  • 강윤아;한순흥
    • 한국CDE학회논문집
    • /
    • 제19권2호
    • /
    • pp.191-201
    • /
    • 2014
  • A 3D CAD system that can be used on a smart device is proposed. Smart devices are now a part of everyday life and also are widely being used in various industry domains. The proposed 3D CAD system would allow modeling in a rapid and intuitive manner on a smart device when an engineer makes a 3D model of a product while moving in an engineering site. There are several obstacles to develop a 3D CAD system on a smart device such as low computing power and the small screen of smart devices, imprecise touch inputs, and transfer problems of created 3D models between PCs and smart devices. The author discusses the system design of a 3D CAD system on a smart device. The selection of the modeling operations, the assignment of touch gestures to these operations, and the construction of a geometric kernel for creating both meshes and a procedural CAD model are introduced. The proposed CAD system has been implemented for validation by user tests and to demonstrate case studies using test examples. Using the proposed system, it is possible to produce a 3D editable model swiftly and simply in a smart device environment to reduce design time of engineers.

Characterization of the 2 inch CNT-FED Fabricated by using a Vacuum In-Line Sealing Technology

  • Kwon, Sang-Jik;Kim, Tae-Ho;Cho, Euo-Sik;Shon, Byeong-Kyoo;Uh, Hyung-Soo;Lee, Jong-Duk;Cho, Sung-Hee;Lee, Chun-Gyoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.870-873
    • /
    • 2003
  • We have fabricated a carbon nanotube field emission display(CNT FED) panel with a 2 inch diagonal size by using screen printing method and vacuum in-line sealing technology. The sealing temperature of the panel was around 390 $^{\circ}C$ and the leak test was carried out for 72 hrs after sealing process. When field emission properties of fabricated and sealed CNT FED panel were characterized and compared with those of unsealed panel which was located in vacuum chamber of vacuum level similar with the sealed panel, the sealed panel showed more improved field emission properties.

  • PDF