• Title/Summary/Keyword: SCADA

Search Result 373, Processing Time 0.032 seconds

Prototype design of fiber optics based 765kV substation control system (광 LAN을 적용한 765kV변전소 감시제어 시범시스템 설계)

  • 송인호;박종화;최종협
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.996-999
    • /
    • 1996
  • This paper introduces prototype design of 765kV Substation control system based on fiber optics LAN and distributed network protocol. Two major important facts, immunity of any surge which frequently occurs in Ultra High Voltage Substation and the most suitable communication protocol for substation control system, are considered on the system design conception. To meet the first fact, use of fiber optics cable and isolation transformer are considered, and to satisfy the second fact, DNP3.0(Distributed Network Protocol) which is IEC870-5 compatible is adopted.

  • PDF

한국형 계통운영시스템 간 보안을 고려한 ICCP/TASE.2 개발

  • Park, Sung-wan;KIM, Jincheol;KIM, Sangtae;LEE, Seungwon
    • Review of KIISC
    • /
    • v.25 no.5
    • /
    • pp.67-73
    • /
    • 2015
  • 한국형 계통운영시스템인 전력거래소(KPX)의 EMS(Energy Management System)와 한국전력공사(이하 한전)의 급전소 SCADA시스템은 서로 ICCP(Inter-Control Center Protocol)를 통한 데이터 교환을 하고 있다. 현재의 ICCP는 데이터 교환에 있어서 보안 기능이 고려되어 있지 않기 때문에 본 논문에서는 안전하고 신뢰성 있는 계통운영시스템 간 데이터 교환을 위한 ICCP/TASE.2의 보안 통신 기능 개발을 소개하고자 한다.

2000년대 전력계통 운용

  • 이경재;김창무
    • 전기의세계
    • /
    • v.35 no.11
    • /
    • pp.694-698
    • /
    • 1986
  • 최근 전자설비를 바탕으로 한 고도 정밀산업의 발달과 국민 생활수준 향상은 전력의 고품질화와 고신뢰성을 절실히 요구하고 있다. 즉, 전력이라는 에너지를 수용가에게 공급하는 것으로 그치지 않고 전력의 품질(주파수와 전압을 규정값 이내로 유지)에 엄격한 제한을 두어야 함은 물론 공급의 신뢰성, 즉 중단없는 전력 공급이 요구되고 있다. 이러한 미래의 전력 경영상의 어려운 과제를 해결하기 위하여 지금까지 이용되어 왔던 자동 급전시스템(ALD:Automatic Load Dispatching)을 최신 기술이 집약된 급전종합자동화시스템(EMS:Energy Management System)으로 교체운용할 계획이다. 지금까지의 분산 설차 운용되어 왔던 지역급전 시스템(SCADA)과 한강수계제어시스템을 EMS시스템과 연계하여 운용함으로써 전력계통을 종합 감시 제어하게 될 것이다.

  • PDF

The development feasibility of MMI for automated distribution systems (배전자동화 시스템용 MMI 개발 가능성)

  • 류재택;박세응
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.107-112
    • /
    • 1990
  • It is necessary to develop graphic MMI (Man-Machine Interface) for the maximum utilization of our installed ADS (Automated Distribution System) for which an operator types and executes string commands. Considering the restrictions and characteristics of the installed ADS and the data for modelled distribution lines, we calculated the time of periodic data acquisition for large number of points. And we presented the performance and characteristics of the graphic MMI system which will be developed and which will facilitate SCADA(Supervisory Control And Data Acquisition) functions.

  • PDF

시뮬레이터 디스플레이 및 제어 시스템 개발

  • 서재승;김성배
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.11a
    • /
    • pp.63-69
    • /
    • 1995
  • 고등기술연구원에서 개발한 중수로형 발전소 시뮬레이션 프로그램을 적용하여 시뮬레이션된 결과를 그래프 및 그래픽 객체를 이용하여 모니터에 디스플레이하며, 그래픽 사용자 인터페이스(GUI) 개념을 이용한 사용자와 시뮬레이터 프로그램 사이의 실시간 상호 정보 교환을 위한 프로그램을 X-윈도우 환경에 기초를 두고 있는 SCADA 개념의 그래픽 데이터 프리젠테이션 툴을 이용하여 개발하였다. 시뮬레이터 디스플레이 시스템은 X-윈도우의 그래픽 라이브러리에서 제공하는 기능을 이용하여 사용자에게 시뮬레이션 결과의 정보를 전달하며, 단지 결과를 보는 것에 비하여 사용자의 제어 값을 입력하여 모사를 할 수 있도록 기계와 사용자 사이의 인터페이스를 제공하는 제어 입력 시스템을 개발하고 이를 이용하여 발전소 운전원의 교육 및 발전소 주요 시스템의 운전 상태와 운전 변수들의 감시 및 제어 기능을 제공하도록 설계하였다.

  • PDF

A Study on the Design of Database to Improve the Capability of Managing Offshore Wind Power Plant (해상풍력 풍력시스템의 관리능력 향상을 위한 데이터베이스 설계에 관한 연구)

  • Kim, Do-Hyung;Kim, Chang-Suk;Kyong, Nam-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.65-70
    • /
    • 2010
  • As for the present wind power industry, most of the computerization for monitoring and control is based on the traditional development methodology, but it is necessary to improve SCADA system since it has a phenomenon of backlog accumulation in the applicable aspect of back-data as well as in the operational aspect in the future. Especially for a system like offshore wind power where a superintendent cannot reside, it is desirable to operate a remote control system. Therefore, it is essential to establish a monitoring system with appropriate control and monitoring inevitably premised on the integrity and independence of data. As a result, a study was carried out on the modeling of offshore wind power data-centered database. In this paper, a logical data modeling method was proposed and designed to establish the database of offshore wind power. In order for designing the logical data modeling of an offshore wind power system, this study carried out an analysis of design elements for the database of offshore wind power and described considerations and problems as well. Through a comparative analysis of the final database of the newly-designed off-shore wind power system against the existing SCADA System, this study proposed a new direction to bring about progress toward a smart wind power system, showing a possibility of a service-oriented smart wind power system, such as future prediction, hindrance-cause examination and fault analyses, through the database integrating various control signals, geographical information and data about surrounding environments.

Implementation of Communication Protocol between Control Centers using ICCP (ICCP를 사용한 전력센터간의 통신 프로토콜 구현)

  • Jang, Kyung-Soo;Chang, Byung-Wook;Hahn, Kyung-Duk;Shin, Dong-Ryeol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.12
    • /
    • pp.3910-3922
    • /
    • 2000
  • Current power systems are distributed geographically and operated in the form of Energy Management System(EMS)/ Supervision Control and Data Acquisition(SCADA) with the aid of computers and communications. Recently a variety of utilities have had interests in using inforrration technology to bring the efficiency and low operational costs. There is also a trend to integrdte the production, transmission, distribution and management/control of power into one and unified distributed system. To this end, Electric Power Hesearch Institute(EPRI) announced a new standard communication protocol called Inter-Control Center Protocol(ICCP).ICCP specifies the use of Manufacturing Message Specification(MMS) for services required by rccr in application layer and supports the communications between heterogeneous control centers. This paper presents the characteristics of MMS,ICCP and their relationship. Futherrnore, we implement the basic functional blocks of ICCP using MMS services under TCI/IP environments. Finally, we model a simple power system and apply the rccp protocol to this system in a window-based scheme, and finally show the operation and validation of this protocol.

  • PDF

Development of RTDS-MATLAB Integrated Simulation Environment for Development and Verification of Voltage Measurement based CVR Control Algorithm (전압계측기반 CVR제어 알고리즘 개발 및 검증을 위한 RTDS-MATLAB 연동 시뮬레이션 환경 개발)

  • Go, Seok-Il;Ahn, Seon-Ju;Choi, Joon-Ho;Nam-Koong, Won;Shin, Chang-Hoon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.549-556
    • /
    • 2016
  • CVR is a technique for reducing power consumption by reducing the voltage of the system and many demonstrations and studies have been conducted in the past. Recently, SCADA-based or AMI-based VVC have been developed and the CVR is used as an important operation mode. Using a variety of instruments, CVR determines the optimal VVC control references by closed loop control. In this paper, we implemented RTDS-MATLAB integrated simulation environment for development and verification of CVR control algorithm based on voltage measurement. The voltage control device of distribution system was modeled using RTDS and MATLAB has constructed a controller that can measure and control the voltage of the simulation system of RTDS. After the capacitor, which is a reactive power control device, flattens the voltage of the system, the control algorithm reduces the voltage of the system by tap control of the OLTC based on the flatten voltage. The proposed system was verified by simulations.

A Study on Development of Systematic Practical Education Model, Equipment Design and Application for Undergraduate linked with Employee Training on the Spot for Practical Engineering Empowerment (실천공학역량강화를 위한 학부와 재직자 교육의 체계적인 연계 모델 개발 및 장비 설계·적용에 대한 연구)

  • Lee, Woo-Young;Kim, Jin-Woo;Cho, Nam-Chae
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.3 no.2
    • /
    • pp.136-141
    • /
    • 2011
  • The current tendency on development and change of equipment system in the factory are overlapped with the specific field of the existing systems such as PLC, DCS and SCADA, and the limited portion of the systems in the specific field stands in their own field. Specially, systematic integration, inspection control system and manufacturing management system, management information system are getting closely linked and therefore we increasingly need the open system. Meeting the needs, manufacturing automated equipments in the factory overcoming the shortcomings of unlinked unit equipment recently are getting changed to the phase closely linking with other systems. The training systems for the university, however, have not kept up with the needs from the industry, in spite that fused complex function and performance are asked in the field. To solve the problems, we suggest that the training courses and the equipment designed for the undergraduate education.

  • PDF

Validation of the Eddy Viscosity and Lange Wake Models using Measured Wake Flow Characteristics Behind a Large Wind Turbine Rotor (풍력터빈 후류 유동특성 측정 데이터를 이용한 Eddy Viscosity 및 Lange 후류모델의 예측 정확도 검증)

  • Jeon, Sang Hyeon;Go, Young Jun;Kim, Bum Suk;Huh, Jong Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.21-29
    • /
    • 2016
  • The wake effects behind wind turbines were investigated by using data from a Met Mast tower and the SCADA (Supervisory Control and Data Acquisition) system for a wind turbine. The results of the wake investigations and predicted values for the velocity deficit based on the eddy viscosity model were compared with the turbulence intensity from the Lange model. As a result, the velocity deficit and turbulence intensity of the wake increased as the free stream wind speed decreased. In addition, the magnitude of the velocity deficit for the center of the wake using the eddy viscosity model was overestimated while the turbulence intensity from the Lange model showed similarities with measured values.