• 제목/요약/키워드: SC Wall

검색결과 99건 처리시간 0.025초

트리즈와 브레인스토밍을 이용한 취부용 피스제거 자동화 시스템의 최적설계에 관한 연구 (A Study on Optimal Design of Piece Removing Automation System Using TRIZ and Brainstorming)

  • 이성조;정원지;김호종;김기정;김정현
    • 한국공작기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.43-48
    • /
    • 2008
  • This study includes contents on an effective designing of the outer-wall piece removing equipment of a hull, by applying TRIZ. To remove the piece, gas torch was used. However, the heat source must be shut down since the heat source of gas torch has a bad influence on this system. This is why TRIZ and Brainstorming were used, to solve this problem. First, we analyzed the system using TRIZ, and then presented the direction a solution is expected to follow. And the most suitable scheme was derived from brainstorming which had been conducted based on the direction of a solution. Lastly we conducted an equipment modeling based on the most suitable scheme we made before, and carried out the heat analysis to inspect its effect by comparing pre-existing mechanism with most suited scheme.

난류 파이프 유동 내 물질전달에 대한 레이놀즈 수 영향: Part I. 평균 농도장 및 저차 난류통계치 (REYNOLDS NUMBER EFFECTS ON MASS TRANSFER IN TURBULENT PIPE FLOW: PART I. MEAN CONCENTRATION FIELD AND LOW-ORDER STATISTICS)

  • 강창우;양경수
    • 한국전산유체공학회지
    • /
    • 제17권3호
    • /
    • pp.1-10
    • /
    • 2012
  • Large Eddy Simulation(LES) of turbulent mass transfer in fully developed turbulent pipe flow has been performed to study the effect of Reynolds number on the concentration fields at $Re_{\tau}=180$, 395, 590 based on friction velocity and pipe radius. Dynamic subgrid-scale models for the turbulent subgrid-scale stresses and mass fluxes were employed to close the governing equations. Fully developed turbulent pipe flows with constant mass flux imposed at the wall are studied for Sc=0.71. The mean concentration profiles and turbulent intensities obtained from the present LES are in good agreement with the previous numerical and experimental results currently available. To show the effects of Reynolds number on the turbulent mass transfer, the mean concentration profile, root-mean-square of concentration fluctuations, turbulent mass fluxes, cross-correlation coefficient, turbulent diffusivity and turbulent Schmidt number are presented.

겨울철 공동주택에서 붙박이장 내 보조난방장치를 활용한 결로 저감 효과 평가 (Assessment of Utilization of Auxiliary Heating Device for Prevention of Condensation in Built-in Furniture in Winter)

  • 이현화;임재한;송승영
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.99-106
    • /
    • 2017
  • Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Most of all, occupants in residential buildings has suffered from property damages due to the condensation and mold of built-in furniture. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. The aim of paper is to analyze the characteristics of adjacent area around built-in furniture's condensation problem and the thermal environment around the built-in furniture in winter through the field measurements at apartment buildings. In this research, the thermal conditions and surface temperature around the built-in furniture were measured during winter season. In this research, we analyzed thermal conditions for built-in furniture which were applied and not applied auxiliary heating device. In results, it is important to consider increasing surface temperature for using heater and decreasing absolute humidity due to the occupants' behavior around built-in furniture for preventing condensation.

원형개구부가 있는 강판 전단벽 시스템을 적용한 학교 건축물의 내진성능평가 (Seismic Performance Evaluation of School Building Reinforced by Circular-Opening Steel Shear Wall System)

  • 이유현;이수헌;이희두;신경재
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.19-26
    • /
    • 2018
  • After the Gyeongju earthquake, school buildings were designated as earthquake shelters. However, the ratio of designed for seismic of domestic school buildings is only 23.2% in Korea, and it is necessary to secure the seismic safety of those. Therefore, in this paper, a target building was selected before the seismic design criteria was established and the seismic performance of the building was evaluated. After the evaluation, reinforcement of the building was carried out using seismic retrofit systems which was previously tested. For this purpose, the evaluation was carried out using OpenSees program and the reliability of the seismic retrofit systems was also verified. In this way, we can more precisely reproduce the response of the building in case of actual earthquake and predict damage of the earthquake in the future.

성견의 3면 골내낭에 calcium carbonate와 calcium sulfate의 혼합이식이 치주조직 치유에 미치는 영향 (EFFECT OF COMPOSITE GRAFT OF CALCIUM CARBONATE AND CALCIUM SULFATE ON THE PERIODONTAL REGENERATION OF 3-WALL INTRABONY DEFECTS OF ADULT DOGS)

  • 최미령;조규성;채중규;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제24권3호
    • /
    • pp.633-648
    • /
    • 1994
  • Synthetic bone graft materials have been used for the regeneration of periodontal tissue lost due to periodontal disease, but the limitations of these materials had prompted the use of composite grafts. Among those, a composite graft of calcium carbonate(CC) and calcium sulfate(CS) is one of those materials that has not been studied extensively. CC, which is extracted from a natural coral, is known to possess osteoconductive property. SC can play an adjunctive role in the regeneration of bone tissue, and has shown good resorbability and biocompatibility. This study was conducted in order to investigate the effects of CC and CS composite graft to the regeneration of bone in the intrabony defects of dogs. 3-wall intrabony defects ub size of $4mm{\times}4mm{\times}4mm$ were created in the alveolar bone in the premolar areas. Then those defects that were treated with root planning only were designated as control, while the experimental group 1 and 2 each received the CC and CS composite grafts in the ratio of 8 : 2 and 5 : 5 the animals were sacrificed after 8weeks and the specimens were histologically analyzed. The results were as follows ; 1. No inflammation or foreign body reaction were observed in all subjects. CS has not been seen due to complete resorption, and resorption pattern of CC was observed. 2. Significant differences(p<0.05) in new cementum formation were observed between control($1.42{\pm}0.64mm$) and experimental groups(group 1 ; $2.53{\pm}0.94mm$, group 2 ; $2.23{\pm}0.96mm$) but the difference between the two experimental groups was not significant. 3. Significant differences(p<0.01) in new bone formation were observed between control($0.59{\pm}0.55mm$) and experimental groups(group 1 ; $2.27{\pm}0.61mm$, group 2 ; $2.05{\pm}0.56mm$) but the difference between the two experimental groups was not significant. 4. The extent of apical epithelial migration has shown no significant difference between control($1.18{\pm}1.24mm$) and experimental groups(group 1 ; $0.51{\pm}0.54mm$, group 2 ; $0.73{\pm}0.70mm$). 5. The extent of bone formation was generally limited to the extent of cementum formation for all groups, and significant correlation was found in the amount of bone formation and cementum formation in experimental group 1.(Co.=0.86, p<0.01) These results suggest that the composite graft of CC and CS is biocomplatible and effective in the new bone and new cementum formations. In the case of 3-wall intrabony defects of dogs, the composite ratio of 8 : 2 and 5 : 5 had shown no significant differences in the healing.

  • PDF

경남 밀양지역 납석광상과 안산암질 모암의 지구화학적 연구 (A Geochemical Study on Pyrophyllite Deposits and Andesitic Wall-Rocks in the Milyang Area, Kyeongnam Province)

  • 오대균;전효택;민경원
    • 자원환경지질
    • /
    • 제25권1호
    • /
    • pp.27-39
    • /
    • 1992
  • Several pyrophyllite deposits occur around the Milyang area where Cretaceous andesitic rocks and spatially related granitic rocks are widely distributed. Pyrophyllite ores consist mainly of pyrophyllite, and quartz with small amount of sericite, pyrite, dumortierite, and diaspore. The andesitic rocks and spatially related granitic rocks in this area suggest that they could be formed from the same series of a calc-alkaline magma series. The contents of $SiO_2$, $Al_2O_3$, LOI(loss on ignition) are enriched, and $K_2O$, $Na_2O$, CaO, MgO, $Fe_2O_3$ are depleted in altered andesitic rocks and ores. Enrichment of As, Cr, Sr, V, Sb and depletion of Ba, Cs, Ni, Rb, U, Y, Co, Sc, Zn are characteristic during mineralization. The pyrophyllite ores can be discriminated from the altered-and unaltered wall-rocks by an increasing of $(La/Lu)_{cn}$ from 4.18~22.13 to 8.98~55.05. In R-mode cluster analysis, Yb-Lu-Y, La-Ce-Hf-Th-U-Zr, $TiO_2-V-Al_2O_3$, Sm-Eu, $CaO-Na_2O-MnO$, Cu-Zn-Ag, $K_2O-Rb$ are closely correlated. In the discriminant analysis of multi-element data, $P_2O_5$, As, Cr and $Fe_2O_3$, Sr are helpful to identify the ores from the unaltered-and altered wall-rocks. In the factor analysis, the factors of alteration of andesitic rocks and ore mineralization were extracted. In the change of ions per unit volume, $SiO_2$, $Al^{3+}$ and LOI are enriched and $Na^+$, $K^+$, $Ca^{2+}$, $Mg^{2+}$, $Mn^{2+}$ and $Fe^{3+}$ are depleted during the alteration processes. The Milyang and the Sungjin pyrophyllite deposits could be mineralized by hydrothermal alteration in a geochemical condition of low activity ratio of alkaline ions to hydrogen ion with reference to spatially related granitic rocks.

  • PDF

자기공명영상(MRI) 검사 시 방사선사의 소음노출 (Noise Exposure of Radiographer Caused by Magnetic Resonance Imaging(MRI))

  • 길종원
    • 한국콘텐츠학회논문지
    • /
    • 제16권11호
    • /
    • pp.699-706
    • /
    • 2016
  • 본 연구는 MRI 검사로 인하여 방사선사가 노출되는 소음의 양을 평가하여 소음저감 시설의 필요성과 제도 마련을 제안하고자 하였다. 소음측정은 대전광역시 S 종합병원의 1.5 Tesla MRI 장비(7개 검사)와 3.0 Tesla MRI 장비(16개 검사)를 대상으로 하였고, 소음측정기는 SC-804를 사용하였다. 소음측정 거리는 MRI 검사실 방음문에서 검사자의 업무 위치까지 100cm 이며, 측정 높이는 업무 시 검사자의 귀 높이 100cm 이다. 검사별 소음측정은 각 검사의 시퀀스(Sequence)마다 발생되는 소음 수치를 관측하여 20초마다 기록하였고 검사별 3회씩 측정하여 평균값을 제시하였다. 연구결과 방사선사가 노출되는 소음의 최댓값은 73.3 dB(A)로 3.0 Tesla 장비에서 시행한 MRCP 검사, 검사별 평균소음의 최댓값은 66.9(3.1) dB(A)로 역시 3.0 Tesla 장비에서 시행한 Myelogram 검사이다. 장비별 평균소음은 3.0 Tesla 장비가 61.9(4.1) dB(A), 1.5 Tesla 장비가 52.0(3.1) dB(A)로 3.0 Tesla MRI 장비가 약 10 dB(A) 정도 높았다(p<0.001). 방사선사가 노출되는 소음의 양은 청력에 영향을 미치는 수준은 아니지만 비청력적영향이 발생할 수 있는 수준이다. 소음을 저감하기 위해 MRI 조정실 후면에 커튼을 설치하여 반사음을 제거할 수 있지만, 제도 마련이 선행되어야 할 것이다.

Nanolayered CuWO4 Decoration on Fluorine-Doped SnO2 Inverse Opals for Solar Water Oxidation

  • Cho, Ha Eun;Yun, Gun;Arunachalam, Maheswari;Ahn, Kwang-Soon;Kim, Chung Soo;Lim, Dong-Ha;Kang, Soon Hyung
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권4호
    • /
    • pp.282-291
    • /
    • 2018
  • The pristine fluorine-doped $SnO_2$ (abbreviated as FTO) inverse opal (IO) was developed using a 410 nm polystyrene bead template. The nanolayered copper tungsten oxide ($CuWO_4$) was decorated on the FTO IO film using a facile electrochemical deposition, subsequently followed by annealing at $500^{\circ}C$ for 90 min. The morphologies, crystalline structure, optical properties and photoelectrochemical characteristics of the FTO and $CuWO_4$-decorated FTO (briefly denoted as $FTO/CuWO_4$) IO film were investigated by field emission scanning electron microscopy, X-ray diffraction, UV-vis spectroscopy and electrochemical impedance spectroscopy, showing FTO IO in the hexagonally closed-pack arrangement with a pore diameter and wall thickness of about 300 nm and 20 nm, respectively. Above this film, the $CuWO_4$ was electrodeposited by controlling the cycling number in cyclic voltammetry, suggesting that the $CuWO_4$ formed during 4 cycles (abbreviated as $CuWO_4$(4 cycles)) on FTO IO film exhibited partial distribution of $CuWO_4$ nanoparticles. Additional distribution of $CuWO_4$ nanoparticles was observed in the case of $FTO/CuWO_4$(8 cycles) IO film. The $CuWO_4$ layer exhibits triclinic structure with an indirect band gap of approximately 2.5 eV and shows the enhanced visible light absorption. The photoelectrochemical (PEC) behavior was evaluated in the 0.5 M $Na_2SO_4$ solution under solar illumination, suggesting that the $FTO/CuWO_4$(4 cycles) IO films exhibit a photocurrent density ($J_{sc}$) of $0.42mA/cm^2$ at 1.23 V vs. reversible hydrogen electrode (RHE, denoted as $V_{RHE}$), while the FTO IO and $FTO/CuWO_4$(8 cycles) IO films exhibited a $J_{sc}$ of 0.14 and $0.24mA/cm^2$ at $1.23V_{RHE}$, respectively. This difference can be explained by the increased visible light absorption by the $CuWO_4$ layer and the favorable charge separation/transfer event in the cascading band alignment between FTO and $CuWO_4$ layer, enhancing the overall PEC performance.

단삼에 의한 Candida albicans 바이오필름 발달의 억제 (Growth of Candida albicans Biofilm is Inhibited by Salvia miltiorrhiza)

  • 이흥식;김연희
    • 한국미생물·생명공학회지
    • /
    • 제47권3호
    • /
    • pp.465-472
    • /
    • 2019
  • Candida albicans는 기회감염을 유발하는 주요한 병원성 진균 중의 하나이다. 캔디다증 치료과정에서 항진균제에 대한 내성이 흔히 발견되는데, 그 이유는 Candida가 바이오필름을 형성할 수 있기 때문이다. 이전의 연구에서 우리는 단삼(Salvia miltiorriza)의 에탄올추출물이 세포막의 투과성을 변화시키고 세포벽 합성을 저해하여 항캔디다 활성을 나타냄을 밝혔다. 본 연구에서는 10개 C. albicans 임상균주가 형성한 초기단계의 바이오필름을 대상으로 XTT 환원분석법으로 대사활성을 측정하니, $78{\mu}g/ml$ 단삼 에탄올추출물에 의해 바이오필름의 대사활성이 평균 51.3% 감소되었다. C. albicans 세포들이 폴리스티렌 표면에 부착하거나 germ tube를 형성하는 과정에서의 단삼 에탄올추출물의 영향을 현미경으로 분석하니, $39{\mu}g/ml$ 단삼 에탄올추출물에 의해 부착된 세포의 밀도는 현저하게 감소하였으나 germ tube 형성은 거의 억제하지 못했다. 단삼 에탄올추출물이 C. albicans SC5314 세포의 균사에 특이적인 유전자 발현에 미치는 영향을 qPCR로 분석한 결과, EAP1은 34.7% (p < 0.001), ALS1은 45.0% (p < 0.001), ALS3는 48.1% (p < 0.001), ECE1은 21.3% (p = 0.006) 억제하였다. 결론적으로 단삼의 에탄올추출물은 초기단계의 C. albicans 바이오필름 발달을 효율적으로 저해하며, 이는 EAP1, ALS1, ALS3 유전자의 발현억제에 따른 세포부착 억제와 관련이 있다. 더불어 단삼 에탄올추출물의 C. albicans 세포막 기능저해와 세포벽 합성억제에 의한 구조변화 또한 세포부착단계에서의 바이오필름 발달억제에 기여할 것으로 추정된다.

면방전 AC PDP에서 세폭소거 방식에 관한 연구 (A Study on the Narrow Erase Method of Surface Discharge AC PDP)

  • 안양기;윤동한
    • 전자공학회논문지SC
    • /
    • 제40권6호
    • /
    • pp.39-47
    • /
    • 2003
  • 본 논문에서는 세폭소거 방식에 관한 연구를 하였으며, 종래에는 세폭소거 이후 전극에 벽전하가 쌓이지 않게 하기 위해 X전극과 Y전극의 전압 레벨을 같게 하여 벽전하를 소거한 반면, 본 논문에서는 세폭소거 이후 X전극과 Y전극의 전압 레벨을 다르게 하고 유지구간에서 스위치의 펄스 타이밍을 조절하여 약한 방전을 일으키게 한 뒤 벽전하를 소거하였다. 실험결과 종래의 방식은 Y_Reset 전압이 150V, 서스테인 전압이 180V일 때 어드레스 전압 마진이 31.3V로 가장 크게 나타났다. 본 논문에서 제안한 방식은 Y_Reset 전압이 100V, 서스테인 전압이 180V, 185V일 때, 어드레스 전압 마진이 38.3Y로 가장 크게 나타났다. 본 논문에서 제안한 방식으로 인하여 종래의 방식 보다 약 7V(22%)정도의 전압마진을 더 확보할 수가 있었다.