• Title/Summary/Keyword: SAW Device

Search Result 115, Processing Time 0.028 seconds

SAW Device Reader Platform Using FPGA Implementation (FPGA를 이용한 SAW Device Reader Platform 구현)

  • Jeong, Yong-Hyun;Son, Young-Tae;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2805-2810
    • /
    • 2010
  • The Passive Device called SAW Device of the ID Tag or a small sensor that can replace all of MEMS technology Micro Device. When using SAW Device will be able to replace that sensor control the power needed or separate space. Enlarge the scope of this advantage to use as a platform for various SAW Device is required. However, the current SAW Sensor development has many, but SAW Sensor that can leverage the platform's development is sketchy. Therefore, this paper implements SAW Reader can be measured in SAW Device Using an FPGA more simple and efficient Reader platform.

SAW Device Reader Platform using FPGA (FPGA를 이용한 SAW Device Reader Platform 구현)

  • Son, Young-Tae;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.447-450
    • /
    • 2010
  • SAW Device 라는 Passive 소자는 ID Tag나 소형센서들을 대체할 수 있는 MEMS 기술의 초소형 Device 다. 이 SAW Device를 이용하면 독립된 공간이나 전원이 필요한 센서 제어 등을 대신할 수 있을 것이다. 이렇게 활용범위가 확대됨에 따라 다양한 SAW Device를 사용하기 위한 플랫폼이 요구된다. 하지만 현재 SAW Sensor는 많은 발전을 해왔지만 SAW Sensor를 활용할 수 있는 플랫폼의 발전은 미흡하기 때문에 본 논문에서는 이러한 SAW Device를 측정할 수 있는 SAW Reader를 FPGA를 이용하여 좀 더 간단하고 효율적인 Reader platform을 구현해 보고자 한다.

  • PDF

The Design and Implementation of Frequency Domain Sampling Surface Acoustic Wave Sensor Platform (Frequency Domain Sampling 방식의 Surface Acoustic Wave Sensor Platform 설계 및 구현)

  • Joh, Yool-Hee;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.220-223
    • /
    • 2012
  • Generally, SAW device, which uses Time Domain Sampling, requires high speed AD converter because SAW device (TDS) needs high sampling speed as much as its high data speed. However, the high price of AD converter discourages makers from using it. On the other hand, SAW device, which uses Frequency Domain Sampling, does not required high speed AD converter because SAW device (FDS) does not need high sampling speed. It is very efficient in price comparison to its performance because high processing speed of SAW device (FDS) can be implemented using low price Embedded Systems. The purpose of the thesis is to solve the issues above by designing and realizing SAW device (FDS) using SAW sensor for TDS.

  • PDF

The Design and Implementation of Frequency Domain Sampling Surface Acoustic Wave Sensor Platform using Cortex-A8 (Cortex-A8을 이용한 Frequency Domain Sampling 방식의 Surface Acoustic Wave Sensor Platform 설계 및 구현)

  • Joh, Yool-hee;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.312-315
    • /
    • 2012
  • Generally, SAW device, which uses Time Domain Sampling, requires high speed AD converter because SAW device (TDS) needs high sampling speed as much as its high data speed. However, the high price of AD converter discourages makers from using it. On the other hand, SAW device, which uses Frequency Domain Sampling, does not required high speed AD converter because SAW device (FDS) does not need high sampling speed. It is very efficient in price comparison to its performance because high processing speed of SAW device (FDS) can be implemented using low price Embedded Systems. The purpose of the thesis is to solve the issues above by designing and realizing SAW device (FDS) using SAW sensor for TDS.

  • PDF

A Study on the Implementation of SAW ID Reader Platform (SAW ID리더 플랫폼 구현에 관한 연구)

  • Yu, Ho-Jun;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.4
    • /
    • pp.766-771
    • /
    • 2008
  • As the practical range of SAW Device extended into various fields including physical sensor, chemical sensor and ID Tag, the platform for various SAW Devices is required more than ever. While SAW ID or Sensors advanced remarkably, the development of platform which applies to SAW Sensor left much to be desired. Therefore this paper represents the SAW platform in order to use SAW ID such as ID Tag or Sensors more conveniently. The SAW platform consists of a RF module which can recognize SAW ID and a main module which has a hish performance processor in order to process the response signal of SAW ID. The main module which has a high performance processor is designed by GUI environmental type to ensure that users are able to use the platform more easily. In this paper, the SAW platform, which is based on ARM9 core processor, used Windows Embedded CE 6.0 OS which brings friendly interface to users. Also the developers can make less effort to design various applications with sensors.

The Design and Implementation of Frequency Domain Sampling Method for Surface Acoustic Wave Sensor Platform (주파수 영역 샘플링 방식의 표면 탄성파 센서 플랫폼 설계 및 구현)

  • Sun, Hee-Gab;Joh, Yool-Hee;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.218-224
    • /
    • 2013
  • Generally, SAW device, which uses Time Domain Sampling, requires high speed A/D converter because SAW device using TDS needs high sampling speed as much as its high data speed. However, the high price of A/D converter discourages makers from using it. On the other hand, SAW device, which uses Frequency Domain Sampling, does not required high speed A/D converter because SAW device using FDS does not need high sampling speed. It is very efficient in price comparison to its performance because high processing speed of SAW device using FDS can be implemented using low price Embedded Systems. The purpose of the paper is to solve the issues above by designing and realizing SAW device(FDS) using SAW sensor for TDS.

Detection of odorants and study on the odorant sensor system by using SAW device (SAW 디바이스를 이용한 냄새물질 측정 및 냄새센서 시스템의 연구)

  • 장상목;김기영;김종민;최용성;권영수
    • Electrical & Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.48-55
    • /
    • 1995
  • A surface acoustic wave (SAW) sensor for the detection of odorants has been constructed by depositing various phospholipids and fatty acids onto the surface of the SAW device. The characteristics of a SAW device operating at 310 MHz deposited with silicon monoxide were analyzed. Menthone, amylacetate, acetoin, and other organic gases show different affinities to the coated lipids. An explanation is given for different odorant affinities based on the monolayer properties of phospholipids. The identification of odorants depending on the tkpe of lipid used for coating is discussed in terms of the similarity of their normalized resonant frequency shift patterns. Using a number of different lipid-coated SAW devices, odorants can be identified by a computerized pattern recognition algorithm.

  • PDF

Failure Mechanism Analysis of SAW Device under RF High Power Stress (RF 고전력 스트레스에 의한 SAW Device의 고장메카니즘 분석)

  • Kim, Young-Goo;Kim, Tae-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.215-221
    • /
    • 2014
  • In this paper, the improved power durability test system and method for an reliability analysis of SAW device is proposed and the failure mechanism through failure analysis is analyzed. As a result of the failure analysis using microscope, SEM and EDX, the failure mechanism of the SAW device is electromigration due to joule heating under high current density and high temperature condition. The electromigration makes voids and hillocks in the IDT electrode and the voids and hillocks can lead to short circuit and open circuit faults, respectively, increasing the insertion loss of an SAW filter. The accelerated life testing of the SAW filter for 450MHz CDMA application using the proposed power durability test system and method is carried out. $B_{10}$ lifetime of the SAW filter using Eyring model and Weibull distribution is estimated as about 98,500 hours.

Surface Acoustic Wave Sensor using Electroactive Paper (EAPap) (Electroactive Paper (EAPap)를 이용한 표면탄성파 센서)

  • Lee, Min-Hee;Kim, Joo-Hyung;Kim, Jae-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.368-371
    • /
    • 2008
  • Cellulose based Electroactive Paper (EAPap) has been developed as a new smart material due to its advantages of piezoelectricity, large displacement, low power consumption, low cost and flexibility. EAPap can be used fur a surface acoustic wave (SAW) device using the piezoelectric property of EAPap, resulting in the cost effective and flexible SAW device. In this paper, inter digit transducer (IDT) structure using lift-off technique with a finger gap of $10{\mu}m$ was used for micro fabrication of the cellulose EAPap SAW devices. The performance of IDT patterned SAW device was characterized by a Network Analyzer. The feasibility of cellulose EAPap as a potential acoustic device was presented and explained.

  • PDF

Characteristic analysis and design of a precise manipulation device using surface acoustic wave (표면탄성파를 이용한 이송장치의 IDT 형상 변화에 따른 특성 연구)

  • Eom, Jinwoo;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.79-83
    • /
    • 2014
  • In this paper, SAW devices are fabricated using various IDT shape(Single/Double) to check an effect of the IDT on SAW device. And based on theory of a particle velocity moved by SAW and IDT, a particle velocity is measured and calculated. Depend on insert power, a particle velocity using Single-IDT SAW device is about two times bigger than Double-IDT SAW device and it's almost same with a theoretical different.

  • PDF