• 제목/요약/키워드: SAPS

검색결과 87건 처리시간 0.032초

Problems and improvement methods of passive treatment systems for acid mine drainage in Korea

  • Ji, Sang-Woo;Ko, Ju-In;Kim, Sun-Joon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.504-510
    • /
    • 2003
  • This study has been carried out to evaluate the passive treatment systems for acid mine drainage in Korea and to suggest, if possible, the method for the improvement. 35 passive treatment systems in 27 mines have been constructed since 1996. SAPS, being the main process, was combined with more than one of processes such as anaerobic wetland, aerobic wetland, and oxidation pond for the construction of passive treatment system. Problems observed during the operation include the poor sulfate removal ratio, overflow, leakage, unusabless of the whole system, and inefficiency. The reasons of the poor sulfate removal ratio are believed that the low temperature during the winter prohibits the SRB activity and HRT for bacterial sulfate reduction is insufficient. An alternative method In Adit Sulfate Reducing System which enables to keep the temperature constant at about $15^{\circ}C$ was suggested. IASRS is the methods of placing the SAPS inside the adit, which enables the temperature around the system constant can be maintained. The experiments using the laboratory scaled model systems made up of four sections showed high efficiencies in pH control and metal removal ratios, but showed still low sulfate removal ratio of about $23\%$ also with high COD at the beginning of the operation.

  • PDF

초기 동맥혈 Carboxyhemoglobin 농도가 높았던 화상 환자들의 예후지표에 관한 연구 (The Early Prognosis of Burn Patients with Elevated Initial Arterial Carboxyhemoglobin Level)

  • 최창순;김철홍;김근숙;이태유;정연손;엄광석;박용범;장승훈;김동규;박명재;이명구;현인규;정기석;김종현
    • Tuberculosis and Respiratory Diseases
    • /
    • 제55권2호
    • /
    • pp.188-197
    • /
    • 2003
  • 연구배경 : 고열과 유독가스에 의한 흡입 폐 손상은 화상 환자에서 화재와 관련한 주된 사망원인이다. 따라서 조기진단과 적절한 치료가 중요한데, 본 연구는 초기 COHb 농도가 증가한 화상 환자의 임상 특성 및 경과를 관찰하고 흡입 폐 손상에 대한 예후인자를 알아보고자 하였다. 방 법 : 2001년 8월부터 2002년 7월까지 응급실 통해 내원한 1,416명 환자 중 동맥혈 가스검사에서 COHb 농도가 5% 이상인 39명을 사망군(12명)과 생존군(27명)으로 나누어, 임상특성, 임상적 흡입 손상 정도, 흉부 X-선 소견, 화상 체표 면적, APACHE II 점수, SAPS II 점수 등을 후향적으로 비교하였다. 결 과 : 생존군과 사망군 사이에 COHb 농도는 각각 $10.3{\pm}8.8%$, $9.7{\pm}5.7%$, 화상 체표면적은 $16.6{\pm}17.8%$, $60.7{\pm}28.8%$였다. 임상적 흡입 폐 손상 정도 및 초기 흉부 X-선 소견은 생존군과 사망군 사이에 유의한 차이점을 관찰할 수 없었다. 두 군사이의 사망관련 인자로는 화상 체표면적, APACHE II 점수, SAPS II 점수, 기계 호흡 및 총 입원기간이 관여하고 있었으나 다변량 분석에서 화상 체표 면적이 가장 중요한 사망관련 인자였다. 결 론 : 초기 동맥혈 COHb 농도가 증가되어 있는 화상환자의 예후는 불량할 것으로 기대되기 때문에 치료에 많은 관심을 기울여야 할 것으로 사료된다. 하지만, COHb이 흡입 폐 손상을 동반한 화상 환자의 예후에 미치는 효과에 대해서는 향후 전향적 연구를 통해서 검토되어져야 할 것으로 생각된다.

만성 폐쇄성 폐질환에서 급성 호흡부전 발생시 Simplifed Acute Physiology Score에 따른 단기예후의 평가 (Determination of Short Term Prognosis Among Chronic Obstructive Lung Disease with Acute Respiratory Failure According to Simplified Acute Physiology Score)

  • 이상표;성윤업;김상훈;김봉식;김영훈;박인원;최병휘;허성호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제40권5호
    • /
    • pp.532-539
    • /
    • 1993
  • 임상에서 환자의 생존율을 평가하는 것은 순간순간 당면하는 치료를 결정함에 있어 중요하다. 특히 만성 폐쇄성 폐질환에서 급성 호흡부전증은 대부분의 환자들이 궁극적으로 겪게 되는 질병의 경과로 여겨지고 있고 이들을 치료하는 과정에서 질병 자체의 비가역적인 특성과 기계호흡 자체의 부작용으로 인하여 중환자실에서 인공호흡기의 부착여부에 대한 논란이 계속되고 있으나, 아직 이에 대한 뚜렷한 기준이 없는 상태이다. 이에 본 연구에서는 입원 첫 24시간이내에 측정가능한 14개의 임상지표를 이용하여(Simplified Acute Physiology Score, 이하 SAPS) 환자의 중증도와 사망률을 예측해 보는 것이었다. 대상환자는 1980년부터 1992년까지 중앙대학 부속병원에서 입원치료를 받은 74명의 만성 폐쇄성 폐질환에 동반된 급성 호흡부전증 환자들에 대한 후향성 연구로 시행하였고, 결과는 다음과 같다. 1) 사망율은 34%(25/74), 생존율은 66%(49/74)였으며, 나이가 많을수록 유의하게 사망율이 높았다. 2) 기저 폐기능 검사치에 따른 사망율의 차이는 없었다. 3) SAPS는사망군에서 10.8, 생존군에서 6.5로 유의한 차이가 있었고, SAPS와 사망율 사이에는 유의한 상관관계가 있었다. 4) SAPS에 포함되는 14개의 임상지표 이외에 입원당시 악액질, 뇌병증, 혈중 Phosphate와 Creatinine 농도에 따라 유의한 사망율의 차이가 있었다. 결론적으로, SAPS는 만성 폐쇄성 폐질환에 동반된 급성 호흡부전증 환자의 예후와 중증도 평가에 유용하며, 이러한 환자군에서 SAPS에 포함되는 14개의 임상지표 이외에도 혈중 Creatinine 농도, 혈중 Phosphate 농도, 입원 당시 악액질유무, 뇌병변에 의한 신경학적 증상의 유무가 예후에 중요한 영향을 미친다고 사료되며, 적극적인 치료와 인공호흡기 치료의 결정에서 SAPS의 사용이 타당하리라 여겨지나, 향후 대단위 전향적 연구가 필요하리라 여겨진다.

  • PDF

일월탄광에서 유출되는 산성광산배수 자연정화시설의 정화 효율 평가 및 침전물의 특성연구 (Evaluation of Purification Efficiency of Passive Treatment Systems for Acid Mine Drainage and Characterization of Precipitates in Ilwal Coal Mine)

  • 류충석;김영훈;김정진
    • 한국광물학회지
    • /
    • 제27권2호
    • /
    • pp.97-105
    • /
    • 2014
  • 일월탄광에는 산화조, SAPS, 소택지의 3단계 자연정화시설이 설치되어 있으며 갱내수를 모아 정화한 후 주변 하천으로 유출시키고 있다. 일월탄광 갱내수의 pH 값은 계절에 관계없이 2.28-2.42로 낮은값을 나타내지만 산화조를 거치는 동안 pH 값은 6.17-6.53 급격하게 증가한다. 정화시설에 의한 정화효율은 $SO_4$, Mg, Al, Ca, Mn은 각각 약 50%, 40%, 100%, 24%, 59%이다. 갱내수의 Fe는 아주 낮은 값($1.06-1.09mg/{\ell}$)이지만 정화시설을 거치는 동안 100%의 제거효율을 나타낸다. 이와 같이 일월탄광에 설치한 정화시설은 pH 상승과 Fe와 Al의 제거 효율은 높지만 $SO_4$, Mg, Ca, Mn 등은 60% 이하로 상대적으로 낮다. 따라서 이러한 이온을 제거하기 위해서는 다른 정화기술을 적용해야 할 것으로 판단된다. pH 2.28-2.42 범위인 갱내수가 유입되는 정화시설 바닥에 침전되는 침전물은 슈워트마나이트이며 ($Fe_8O_8(OH)_6SO_4$), pH 5.83-5.96인 침출수에서는 2-line 페리하이드라이트(2-line $Fe_2O_3{cdot}0.5H_2O$H2O)가 침전된다.

유기인계 농약 중독 환자에서 초기 적혈구 아세틸콜린에스테라제 활성도의 임상적 의의 (Clinical Implication of Acetylcholinesterase in Acute Organophosphate Poisoning)

  • 김훈;한승백;김준식;이미진;박준석;권운용;어은경;오범진;이성우;서주현;노형근
    • 대한임상독성학회지
    • /
    • 제6권1호
    • /
    • pp.25-31
    • /
    • 2008
  • Purpose: Acute organophosphate (OP) poisoning may be monitored by measuring the acetylcholinesterase (AChE). It is important to assess severity and establish prognostic tests in the early stage of OP poisoning. The aim of this study was to look at the relationship between various clinical aspects of the OP poisoning, prognostic indicators of OP poisoning including Simplified Acute Physiology Score (SAPS) 3, and the associated changes in AChE levels. Methods: Clinical data and initial AChE levels from thirty-seven patients with OP poisoning were prospectively reviewed from 12 teaching hospitals in South Korea from August 2005 to July 2006. Clinical manifestations at the time of arrival such as miosis, respiratory abnormality, salivation, urinary incontinence, GCS score, AVPU scale, need for intubation, and mechanical ventilation requirements were recorded. SAPS 3 was calculated using clinical data and laboratory results. Results: The median level of AChE was 9.8 (1.3-53.6) U/gHb. There was no significant difference in AChE levels between the groups with and without cholinergic symptoms. The median level of AChE of the patients who required intubation and those who did not were 3.5 U/gHb and it 19.7 U/gHb respectively (Mann-Whitney test; p<0.001). The AChE levels were also significantly different (p=0.007) in patients who needed mechanical ventilation compared to those who did not with AChE levels found to be 3.1 U/gHb and it was 14.8 U/gHb, respectively. Level of consciousness assessed using the AVPU scale was correlated with AChE levels (Kruskal-Wallis test; p=0.013). GCS score were correlated with AChE levels (p=0.007, Spearman's rho = 0.454). In addition, the lower the level of initial AChE, the longer the ICU stay (p=0.029, Spearman's rho=-0.380). SAPS 3 was inversely correlated with the initial AChE (p<0.001, Spearman's rho=-0.633). Conclusion: In the acute OP poisoning, low AChE levels appear to help indicate the severity of poisoning. The initial AChE level may be a useful prognostic parameter for acute OP poisoning.

  • PDF

고흡수성 수지(SAP)를 이용한 내부양생이 초고성능 콘크리트(UHPC)의 수화반응, 자기수축, 내구성 및 역학적 특성에 미치는 영향 (Effect of Internal Curing by Super-Absorbent Polymer (SAP) on Hydration, Autogenous Shrinkage, Durability and Mechanical Characteristics of Ultra-High Performance Concrete (UHPC))

  • 강성훈;문주혁;홍성걸
    • 콘크리트학회논문집
    • /
    • 제28권3호
    • /
    • pp.317-328
    • /
    • 2016
  • 이 연구의 목적은 내부양생을 위한 고흡수성 수지(SAP)의 혼입이 초고성능 콘크리트(UHPC)의 수화특성, 자기수축, 내구성 및 역학적 특성에 미치는 영향을 알아보는 것이다. 이를 위해 입도범위는 유사하지만 화학적 구조가 다른 2 종류의 SAP이 선택되었고, 이러한 SAP이 혼입된 UHPC의 성능이 실험을 통해 평가되었다. 평가결과는 SAP의 종류, 그리고 혼입 여부에 따라 비교되었다. 수화반응성과 수화생성물 확인을 위해 등온열량계 및 XRD를 이용한 실험이 각각 진행되었고, 이 실험을 통해 초기 재령일에서 수화반응성 및 장기 재령일에서의 수화생성물을 확인하였다. UHPC의 수축저감제로서 SAP의 적용 가능성을 확인하기 위해 자기수축 변형율, 압축강도 및 염분침투성을 측정하였다. 또한, SEM 이미지 촬영을 통해 SAP이 UHPC 내부에서 형성한 공극을 실제로 확인하고 분석하였다. 이러한 분석 및 평가결과를 통해, SAP을 이용한 내부양생은 역학적 성능과 내구성 저하 없이 UHPC의 자기수축을 저감시킬 수 있다는 결론을 내렸다. 실험에 사용된 두 종류의 SAP 중에서, UHPC 내부에서 흡수력이 더 우수한 SAP_AM이 SAP_AA 보다 수축저감성능 뿐만 아니라, 장기적인 수화반응성, 압축강도, 염분침투 저항력에서도 성능이 더 우수한 것으로 나타났다.

고로쇠 및 거제수나무 수액 간장의 이화학적 분석 및 관능 평가 (Physicochemical Analysis and Sensory Evaluation of Fermented Soy Sauce from Gorosoe(Acer mono Max.) and Kojesu(Betula costata T.) Saps)

  • 최선영;성낙주;김행자
    • 한국식품영양학회지
    • /
    • 제19권3호
    • /
    • pp.318-326
    • /
    • 2006
  • 기능성이 보완된 고품질의 간장을 제조하기 위하여 기존의 간장 담금용 용수 대신에 고로쇠 및 거제수나무 수액을 이용하여 간장을 담근 후 120일간 숙성시키면서 간장의 맛과 기능성과 관련이 있는 화학 성분을 분석하였다. 간장 숙성 중 유리당을 분석한 결과 대조군에서는 3종의 유리당(fructose, glucose 및 galactose), 수액 간장에서는 상기 유리당 외에 sucrose가 검출되었다. 간장의 숙성 중 유리당은 불규칙한 함량 변화를 보였으나, 숙성 기간 중 모든 시료군에서 galactose의 함량이 월등히 높았다. 유기산은 butyric acid의 함량이 월등히 높았으며 반면에 fumaric acid는 미량에 분과하였다. 무기물은 모든 시료군에서 K와 P의 함량이 가장 높았다. 수액 간장에서 대조군에 비해 Ca, Mg및 Fe의 함량이 높게 나타났다. 간장 숙성 중 아미노산은 총 15종이 검출되었으며, glutamic acid의 함량(185.6${\pm}$1.0${\sim}$363.0${\pm}$2.7 mg/100 ml)이 가장 높았고, 다음으로 aspartic acid, lysine 및 leucine의 순이었으며, proline과 arginine은 모든 시료에서 검출되지 않았다. 핵산 관련 물질은 대조군과 시료군 모두 숙성 기간에 관계없이 AMP의 함량(7.5${\pm}$0.2 ${\mu}$mol/100 ml이상)이 가장 높았으며, 반면에 inosine은 전혀 검출되지 않았다. 관능검사 결과 고로쇠 수액 간장, 거제수 수액 간장 및 대조군의 순으로 맛이나 향이 강하게 나타났다.

혹한기 광산배수 처리 공정 내 황산염 환원 박테리아의 활성 증진을 위한 발광다이오드의 이용 제안 (Use of Light Emitting Diode for Enhanced Activity of Sulfate Reducing Bacteria in Mine Drainage Treatment Process Under Extreme Cold)

  • 최유진;최연우;이안나;김경웅
    • 자원환경지질
    • /
    • 제50권3호
    • /
    • pp.251-256
    • /
    • 2017
  • 본 연구는 폐광산에서 배출되는 산성광산배수가 하천수 및 지하수에 유출되면서 발생되는 환경 오염들을 막기 위해 생물학적 자연정화 처리 방법인 연속적 알칼리도 생성 시스템의 효율을 증대 시키는 방안에 관한 연구이다. 연속적 알칼리도 생성 시스템를 이용한 산성광산배수의 처리는 대부분 황산염 환원 박테리아를 이용한 생물학적 처리 기술이며, 실제 현장 적용실험에서 그 효과가 증명되었고, 광산배수 정화 사업에 적용하도록 개발된 사례가 많다. 그러나 계절적인 온도 저하로 기온이 매우 낮은 겨울이나 초봄 동안에는 황산염 환원 박테리아가 생존은 가능하더라도 황산염을 환원시키는 활동이 거의 멈추게 되어 지속적인 산성광산배수 처리 효율에 문제점을 야기한다. 본 연구에서는 연속적 알칼리도 생성 시스템에 발광 다이오드를 접목하여 유기물 층의 황산염 환원 박테리아 활성을 증진시키고, 온도가 낮은 겨울철에도 발광 다이오드의 발열 효과를 이용하여 활성 온도를 유지 할 수 있는 방안을 제안한다. 더불어, 산성광산배수 처리 시설은 전력을 쉽게 공급할 수 없는 곳에 위치한 지리적인 특성을 고려하여, 발광 다이오드에 전원을 공급할 수 있는 전원 공급 장치로 태양 전지 모듈 사용을 제안한다. 본 방법을 통하여 추가적 연구들이 진행된다면, 태양광 에너지와 발광 다이오드를 융합한 친환경적인 방법을 이용하여 겨울철에도 산성광산배수 처리 기술의 효율을 극대화 할 수 있을 것이다.

갱내 황산염환원시설(IASRS)을 이용한 산성광산배수 처리에 관한 연구

  • 지상우;이상훈;유상희;김재욱;김선준
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.184-187
    • /
    • 2003
  • To solve the problems of operating passive mine drainage treatment systems, the In Adit Sulfate Reducing System(IASRS) was suggested. By placing the SAPS inside the adit, the condition of constant temperature of 10~15$^{\circ}C$ can be maintained. The experiments using the models made up by four sections showd good efficiencies in pH control and metal removal rate, but showed still low sulfate removal rate of about 30% with high COB in the begining of the operation.

  • PDF

김치에서의 활성 TMV 검출 (Detection of tobacco mosaic virus from "Kimchi")

  • 박은경;김정화;이영근
    • 한국연초학회지
    • /
    • 제5권1호
    • /
    • pp.43-47
    • /
    • 1983
  • Tobacco mosaic virus (TMV) was detected from Kimchi by biological and serological assay 5. Kimchi samples three month after cooked were collected, and were inoculated on N. tabacum var. Burley 21 and NC 95. Out of 33 samples, 6 showed typical symptoms induced by TMV, local necrotic lesions on Burley 21 and mosaic on NC 95. All saps from tobacco leaves showed the mosaic symptom reacted positively against TMV antiserum by agar gel double diffusion test. Based on the results, the Kimchi is considered as one of the important inoculum sources in Korea.

  • PDF