• Title/Summary/Keyword: S3D

Search Result 21,004, Processing Time 0.053 seconds

Anylsis of Stereoscopic 3D Production Issues -Focus on S3D Cinematograhpy- (3D입체 영상작업 분석 -입체 3D촬영을 중심으로-)

  • Park, Jong-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.7
    • /
    • pp.121-130
    • /
    • 2011
  • If you ask many Stereographers how to make a good S3D and you will get all different answers. There are several 3D knowledges and opinions that were not always in agreement. we have to choose which advice to follow and find our own way. But there will be no durable screening of S3D films without a minimal viewing comfort of all the audience whatever the differences of their vision. First of all, We always consider several factors to get an appropriate S3D shot before moving on to production. This is intended to provide a practical example on S3D film production. I hope that this article will encourage further research on this topic.

COMBINATORIAL PROOF FOR THE POSITIVITY OF THE ORBIT POLYNOMIAL $O^{n,3}_d(q)$

  • Lee, Jae-Jin
    • Journal of applied mathematics & informatics
    • /
    • v.30 no.3_4
    • /
    • pp.455-462
    • /
    • 2012
  • The cyclic group $Cn={\langle}(12{\cdots}n){\rangle}$ acts on the set ($^{[n]}_k$) of all $k$-subsets of [$n$]. In this action of $C_n$ the number of orbits of size $d$, for $d|n$, is $$O^{n,k}_d=\frac{1}{d}\sum_{\frac{n}{d}|s|n}{\mu}(\frac{ds}{n})(^{n/s}_{k/s})$$. Stanton and White[7] generalized the above identity to construct the orbit polynomials $$O^{n,k}_d(q)=\frac{1}{[d]_{q^{n/d}}}\sum_{\frac{n}{d}|s|n}{\mu}(\frac{ds}{n})[^{n/s}_{k/s}]{_q}^s$$ and conjectured that $O^{n,k}_d(q)$ have non-negative coefficients. In this paper we give a combinatorial proof for the positivity of coefficients of the orbit polynomial $O^{n,3}_d(q)$.

A Linkage Study of Chromosome 5 D5S39(p105-153Ra), D5S76(p105-599Ha), and $D_2$, $D_3$ Receptor Gene($DRD_2$, $DRD_3$) in Schizophrenics in Korean Pedigree (한국인 정신분열병 가계의 염색체 5번 D5S39(p105-153Ra), D5S76(p105-599Ha) 및 도파민 $D_2$, $D_3$ 수용체 유전자좌간의 연관관계 연구)

  • Oh, Kang-Seob;Kim, Young-Tae;Lee, Min-Soo
    • Korean Journal of Biological Psychiatry
    • /
    • v.1 no.1
    • /
    • pp.67-78
    • /
    • 1994
  • The author examined the relationship of two markers, D5S39(p105-153Ra), D5S76(p105-599Ha) of chromosome 5 and $D_2$, $D_3$ receptor genes in a Korean schizophrenic pedigree using polymerase chain reaction(PCR). The results were as follows : 1) On D5S39 locus, 5 different alleles(224/226 bp : 4 cases, 218/226 bp : 3 cases, 222/226 bp : 3 cases, 218/230 bp : 1 case, 222/224 bp : 1 case) were produced. 2) On D5S76 locus, 5 different alleles(102/112 bp : 4 cases, 94/112 bp : 3 cases, 108/112 bp 3 cases, 94/94 bp : 1 case, 102/108 bp 1 case) were produced. 3) On $D_2$ receptor gene, 3 different alleles($A_1A_2$ : 8 cases, $A_1A_1$ : 2 cases, $A_2A_2$ : cases) were produced. 4) On $D_3$ receptor gene, 2 different alleles(1/2 : 7 cases, 1/1 : 5 cases) were produced. The author had not find any specific alleles on all four loci in all pedigree nor any specific alleles in the schizophrenic patients. Though the author has not found absolute relationship between the four loci and the onset of schizophrenia, there still remains the possibilities if the more detailed and elaborated pedigree studies are done.

  • PDF

Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

A study of refraction state of middle aged & manhood in Daegu (대구지역 중·장년층의 굴절상태 연구)

  • Choi, Gei-Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.323-332
    • /
    • 2004
  • This study researched the visual acuity test object and Auto-refractormeter, visual of near power. The object were composed of middle aged, the old men and women who in habit Daegu. The results were as follows : 1. The subjects consisted of 537 people, 29.98% men, 70.02% women. 2. The emmetropia was 1.12% for myopia, 2.79% for hyperopia, 96.09% for astigmatism. 3. The abnormal refraction was composition for myopic compound astigmatism(16.57%), hyperopia compound astigmatism(45.62%), Mixed astigmatism(33.89%). 4. On the Myopic Spherical Equivalent(S.E) power, the range of -0.50D ${\leq}$ M.S.E < -1.00D was 21.67%, -1.00D ${\leq}$ M.S.E < -2.00D was 48.89%, -2.00D ${\leq}$ M.S.E < -6.00D was 29.44%. 5. On the Hyperopic Spherical Equivalent(S.E) power, the range of +0.50D ${\leq}$ H.S.E < +1.00D was 28.57%, +1.00D ${\leq}$ H.S.E < +2.00D was 49.30%, +2.00D ${\leq}$ H.S.E < +6.00D was 23.13%. 6. The addition power was 1.00D(8.01%), 1.50D(8.57%), 2.00D(13.78%), 2.50D(16.57%), 3.00D(16.95%), 3.50D(17.88%), 4.00D(18.25%).

  • PDF

Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery (변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가)

  • Jang, Wonseok;Park, Kwangwoo;Shin, Dongbong;Kim, Jongdae;Kim, Seijoon;Ha, Jinsook;Jeon, Mijin;Cho, Yoonjin;Jung, Inho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • Purpose : This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. Materials and Methods : The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. Results : The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0.3%. However, to mention the average prescribed dose for the part of lung and heart, that of 3D-bolus was decreased by 11% for lung and by 8% for heart, compared to that of step-bolus. Conclusion : It was confirmed through this research that the dose uniformity could be improved better through the device of 3D-bolus than through the device of step-bolus, as the device of 3D-bolus, produced in consideration of the contact condition of skin surface of chest wall, could be attached to patients' skin more nicely and the thickness of chest wall can be guaranteed more accurately by the device of 3D-bolus. It is considered that 3D-bolus device can be highly appreciated clinically because 3D-bolus reduces the dose on the adjacent organs and make the normal tissues protected, while that gives no reduction of dose on chest wall.

  • PDF

Developing a 3D Indoor Evacuation Simulator using a Spatial DBMS (공간 DBMS를 활용한 3차원 실내 대피 경로 안내 시스템)

  • Kim, Geun-Han;Kim, Hye-Young;Jun, Chul-Min
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.4
    • /
    • pp.41-48
    • /
    • 2008
  • Currently used 3D models, which are mostly focused on visualization of 3D objects and lack topological structure, have limitation in being used for 3D spatial analyses and applications. However, implementing a full topology for the indoor spatial objects is less practical due to the increase of complexity and computation time. This study suggests an alternative method to build a 3D indoor model with less complexity using a spatial DBMS. Storing spatial and nonspatial information of indoor spaces in DB tables enables faster queries, computation and analyses. Also it is possible to display them in 2D or 3D using the queried information. This study suggests a 2D-3D hybrid data model, which combines the 2D topology constructed from CAD floor plans and stored in a spatial DBMS and the 3D visualization functionality. This study showed the process to build the proposed model in a spatial DBMS and use spatial functions and queries to visualize in 2D and 3D. And, then, as an example application, it illustrated the process to build an indoor evacuation simulator.

  • PDF

A Comparison on Clothing Appearance of 2D Flat Sketch, 3D Virtual Clothing and Real Clothing -Based on the Evaluation of Chinese in Their 20s and 30s- (의복의 2D 도식화, 3D 가상착의, 실제착의 외관 평가 비교 -20~30대 중국인 평가를 중심으로-)

  • Wang, Xueying;Kwon, Chae-Ryung;Kim, Dong-Eun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.2
    • /
    • pp.193-208
    • /
    • 2020
  • This study investigated similarities and differences between 2D flat sketch, 3D virtual clothing and real clothing images. Flat sketch, 3D virtual clothing, and real clothing images of T-shirts and dresses were made. Questionnaires were prepared for fit evaluation, sensory evaluation, and location evaluation. A survey of 440 questionnaires was collected from Chinese women in their 20s and 30s. As results of the sensibility evaluation, 3D virtual clothing expressed real clothing images slightly more similar than a 2D flat sketch. As results of the fit evaluation of the dresses, 2D flat sketch and 3D virtual clothing were rated as slightly longer/wider, and real clothing images were rated as slightly shorter/narrower. The results suggested that presenting 3D images with avatars as 3D virtual clothing images will provide more accurate fit evaluation results. This study presented possibilities and methods for apparel companies to utilize 3D system as an effective apparel production tool.

Effects of Initial EC Values on Seedling Growth and Utilization of Minerals in Hydroponic Rice Seedling Raising (벼 수경육묘에서 양액의 EC 초기 설정에 따른 묘 생육과 무기성분의 이용)

  • 김영광;홍광표;정완규;손길만;송근우;강진호
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.3
    • /
    • pp.200-204
    • /
    • 2003
  • This study was conducted to develop a technology for raising seedlings hydroponically using the bed in which the seedlings grew in nutrient solution without soil. In order to establish the optimum EC value of nutrient solution, six initial EC values (1, 2, 3, 4, 5 dS/m and control) of Yoshida's hydroponic solution were examined. Seedling height and dry weight increased with increasing below EC up to 3.0 dS/m, but showed no significant increase at higher than EC 3.0 dS/m. Nutrient solution with initial EC of 3.0 dS/m was good to be dropped down nearly to 1 dS/m after 15-day seedling culture. But those with initial EC of 4.0 and 5.0 dS/m were judged not appropriate because of high EC value in waste nutrient solution. Utilization efficiency of minerals of nutrient solution and rice endosperm was higher on the whole at initial EC of 2.0-3.0 dS/m. Considering seedling growth and utilization efficiency of supplied nutrient solution, initial EC is judged to be suitable at 3.0 dS/m.

Development of Stereoscopic 3D Personalized Adventure Game: HowSee (3D 체험형 어드벤처 게임 "HowSee" 개발)

  • Lim, C.J.;Chung, S.T.;Choi, Seung-Hoon;Lee, Chang-Nam;Song, Jang-Sup
    • Journal of Korea Game Society
    • /
    • v.11 no.5
    • /
    • pp.13-22
    • /
    • 2011
  • Advances in display technology, stereoscopic (S3D) in the development of social interest in the content development approach is high but it does not make the standardization of interactive 3D content creation performance is very poor. In this paper, real-time video input from an infrared camera that is based on eye tracking implementation user interface developed 3D interactive adventure game "HowSee" was the process of developing skills in the process, an efficient 3D content production methods were presented. unnormalized S3D-based game content production process on how this development occurred in the trial and how to troubleshoot S3D games, etc. to streamline content creation can be a basis for.