• Title/Summary/Keyword: S-N curve S-N

Search Result 719, Processing Time 0.028 seconds

Fatigue Characteristic of High Impact Polystyrene(HR-1360) Materials (HIPS(HR-1360) 재료의 피로 특성 평가)

  • Kang, Min-Sung;Koo, Jae-Mean;Seok, Chang-Sung;Park, Jae-Sil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.763-769
    • /
    • 2010
  • In recent times, there has been considerable interest in HIPS (High Impact Polystyrene) materials for their use in construction of office equipments, home electronics, housing for electronics appliances, packing containers, etc. However, these materials suffer from problems caused by fatigue fracture. Further, their strength is substantially affected by environmental conditions. Therefore, in this study, the effect of temperature was analyzed by performing a tensile test and a fatigue test. It was observed that the yield strength, the ultimate strength, and the fatigue life decreased relatively with an increase in temperature. Further, an S-N curve can be predicted by using the results of the tensile test and a micro-Vickers hardness test.

Dielectric Characteristics of N2 Gas under Impulse Voltage in a Quasi-Uniform Electric Field (준평등전계에서 임펄스전압에 대한 N2가스의 절연파괴특성)

  • Lee, Bok-Hee;Kim, Dong-Kyu;Li, Feng
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.126-132
    • /
    • 2010
  • This paper presents dielectric characteristics of $N_2$ gas under impulse voltages in a quasi-uniform electric field gap. The experiments were carried out at the test gap applied by the 1.2/50[${\mu}s$] lightning impulse voltage, 180/2500[${\mu}s$] switching impulse voltage, 500[ns]/1[MHz] very fast transient overvoltage(VFTO). The gap separation of sphere-to-plane electrodes was 14[mm] and the electric field utilization factor was about 71.2[%]. The gas pressure ranges from 0.2 to 0.6[MPa]. As a result, the electrical breakdowns are occurred by streamer discharge. Breakdown voltages are linearly increased with the gas pressure and the highest breakdown voltage is appeared under the VFTOs having fast rising time. Breakdown voltages under the positive impulse voltages were higher than those under the negative ones, and also the time to breakdown in the positive polarity is longer than that in the negative polarity.

Prediction for Fatigue Life of Composite Ply-overlap Joint Structures (복합재 플라이 오버랩 조인트 구조의 피로 수명 예측)

  • Yeju Lee;Hiyeop Kim;Jungsun Park
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.2
    • /
    • pp.62-70
    • /
    • 2023
  • We proposed a technique for predicting Stress-Life (S-N) curve or fatigue life using geometric features of a ply-overlap joint structure in which plies of two composite materials are partially or wholly laminated and bonded. Geometric features that could affect fatigue properties of a structure were selected as variables. By analyzing relationships between geometric variables and material constants of the Epaarachchi-Clausen model, a fatigue model for composites, relational expressions of these two factors were proposed. To verify the prediction accuracy of the proposed method, fatigue life of a CFRP/GFRP ply-overlap joint was predicted. Predicted life and life obtained by test data-based model were compared to actual life. High prediction accuracy was confirmed by calculating the coefficient of determination of the predicted S-N curve.

Performance Analysis of Extended n-$\Delta$ Dely-Lock Loops (n-$\Delta$ Delay-Lock Loops의 성능 해석)

  • Ryu, Seung-Mun;Eun, Jung-Gwan;Kim, Jae-Gyun
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.1
    • /
    • pp.16-24
    • /
    • 1981
  • The delay-lock loop (DLL) is a statistically optimum device for tracking the de]ay difference between two correlated waveforms. In this paper an extended n - $\Delta$ (n=1,2,3‥‥) DLL is described, and its baseband performance including the frequency to lose lock is analyzed. The present DLL system employs a correlator and a pseudonoise sequence synthesizer that has been improved from the previously used ones The shape of the correlator characterigtic has the form of expanded S-curve. Despite of increase noise, this extended DLL has desirable characteristics in tracking range and initial synchronization time. Comparing a 3 - $\Delta$ DLL with a 1 - A DLL, the former Bives three times faster initial synchronization time with the serial synchronization method, and gives two times immunity against doppler shift.

  • PDF

Aquatic Plants for Wastewater Treatment (수생식물을 이용한 수질정화에 관한 연구)

  • 나규환;권성환;이장훈
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.49-55
    • /
    • 1996
  • Water parsley(Oenanthe javanica(Blume) DC) was raised with varying population density(S) in the laboratory aquarium unit to determine the growth equation. The population density was measure after 7 days. The resultant growth curve was well fit to the equation 1/S = A+B (1/S0) with a high correlation coefficient ($R^2$ = 0.999). The maximum specific absorption rate was $9.011 \times 10^{-5}$ kg $NO_x-N/kg$ water parsley$\cdot$day and $1.31 \times 10^{-5}$ kg $PO_4-P/kg$ water parsley$\cdot$day when the average population density was $2.62 kg/m^2$. The relationship between population density and nutrient absorption rate, the absorption rate of $NO_x-N$ was 5.04~5.24 mg/l$\cdot$day when the population density was $7.51~10.0 $mg/m^2\cdot day$ and the absorption rate of $PO_4-P$ was 0.56~0.78 mg/l$\cdot$day when the population density was 5.02~10.0 $kg/m^2\cdot day$. Taking into account the nutrient absorption rate and growth rate, the population density between $7.0 kg/m^2\cdot day$ and $8.0 kg/m^2 \cdot day$ was selected. The removal rate of nutrient was investigated after 7 days culture. Removal rate of $NO_x-N$ was 95.6~99.95% with initial concentration of 35 mg $NO_x-N/l$, and the removal rate of $PO_4-P$ was also high, indicating 80.24~98.9% with initial concentration of 5.95 mg $PO_x-P/l$.

  • PDF

Prediction of Cognitive Progression in Individuals with Mild Cognitive Impairment Using Radiomics as an Improvement of the ATN System: A Five-Year Follow-Up Study

  • Rao Song;Xiaojia Wu;Huan Liu;Dajing Guo;Lin Tang;Wei Zhang;Junbang Feng;Chuanming Li
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.89-100
    • /
    • 2022
  • Objective: To improve the N biomarker in the amyloid/tau/neurodegeneration system by radiomics and study its value for predicting cognitive progression in individuals with mild cognitive impairment (MCI). Materials and Methods: A group of 147 healthy controls (HCs) (72 male; mean age ± standard deviation, 73.7 ± 6.3 years), 197 patients with MCI (114 male; 72.2 ± 7.1 years), and 128 patients with Alzheimer's disease (AD) (74 male; 73.7 ± 8.4 years) were included. Optimal A, T, and N biomarkers for discriminating HC and AD were selected using receiver operating characteristic (ROC) curve analysis. A radiomics model containing comprehensive information of the whole cerebral cortex and deep nuclei was established to create a new N biomarker. Cerebrospinal fluid (CSF) biomarkers were evaluated to determine the optimal A or T biomarkers. All MCI patients were followed up until AD conversion or for at least 60 months. The predictive value of A, T, and the radiomics-based N biomarker for cognitive progression of MCI to AD were analyzed using Kaplan-Meier estimates and the log-rank test. Results: The radiomics-based N biomarker showed an ROC curve area of 0.998 for discriminating between AD and HC. CSF Aβ42 and p-tau proteins were identified as the optimal A and T biomarkers, respectively. For MCI patients on the Alzheimer's continuum, isolated A+ was an indicator of cognitive stability, while abnormalities of T and N, separately or simultaneously, indicated a high risk of progression. For MCI patients with suspected non-Alzheimer's disease pathophysiology, isolated T+ indicated cognitive stability, while the appearance of the radiomics-based N+ indicated a high risk of progression to AD. Conclusion: We proposed a new radiomics-based improved N biomarker that could help identify patients with MCI who are at a higher risk for cognitive progression. In addition, we clarified the value of a single A/T/N biomarker for predicting the cognitive progression of MCI.

A Study on the Flexural Fatigue Behavior of R/C Beams Repaired with Concrete-Polymer Composites (유기 및 유기재료로 보수된 R/C 보의 휨 피로거동에 관한 연구)

  • 심종성;황의승;배인환;이은호
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.233-241
    • /
    • 1995
  • In this thesis, the fatigue tests were performed on a series of R /C beams repaired with co& crete-lmlyrner composites to investigate the fatigue bahavior. The three point loading system is used in the fatigue tests. In these tests, relations between the repeated loading cycles and mid-span deflections, number of repeated loading cycles when repaired beams were fractured, the bonding performance of repair materials were observed. On this basis, the mid-span deflections, the crack growth and failure mode of repaired R /C beams were studied. A S-N curve was drawn to present the fatigue strength of repaired beams. From the test results, it was shown that behavior of R /C beams repaired with polymer-cement series were very sirnillar to control beam about bonding performance, mid-span deflections and fatigue strength according to S-N curve drawn by the regression anlysis on the fatigue test results.

Change in Properties of (Ba1-xLax)Fe3+1-tFe4+tO3-y System Depending on Heat Treatment Conditions

  • Lee, Eun-Seok;Lee, Seo-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.6
    • /
    • pp.311-315
    • /
    • 2017
  • The perovskite system $(Ba^{2+}{_{1-x}}La^{3+}{_x})Fe^{3+}{_{1-t}}Fe^{4+}{_t}O_{3-y}$ (y = (1 - x --t)/2) having a composition of x = 0.0, 0.1, 0.2, and 0.3 showedean increase in $Fe^{4+}$ mole ratios with an increase in oxygen partial pressure ($N_2{\rightarrow}air{\rightarrow}O_2$), and with an increasefin s, the $Fe^{3+}$ quantity decreased and oxygen content (3-y value) increased. For each N sampls heat-treated in $N_2$ gas, a considerable weight gain, i.e.g a steadynincrease if oxygen content, was observed in the TGA data on the cooling process. The conductivity values at a constant temperature were in the order of $N_2$$O_2$; the respective log ${\sigma}$ values (${\Omega}^{-1}{\cdot}cm^{-1}$) at 323 K of the BL0 sample were -5.75 (BL0-N), -3.39 (BL0-A), and -0.53 (BL0-O). The mixed valencies of $Fe^{3+}$ and $Fe^{4+}$ ions in each sample were also confirmed by both the oxidation curve above 350 mV and the cathodic reduction curve below 200 mV from cyclic voltammetry.

Analysis of Diethylcarbamazine and Diethylcarbamazine-N-oxide by Gas Chromatography

  • Lee, Suk-Hyang;M.S;Pharm.D
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.475-479
    • /
    • 1996
  • Diethylcarbamazine (DEC, 1-diethylcarbamyl-4-methylpiperazine) is an antiparasitic piperazine derivative used in the treatment of lymphatic filariasis caused by Wuchereria bancrofti, Brugia malayi or grugia timori. DEC-N-oxide is a major metabolite in humans and has antifilarial activity. In carrying out pharmacokinetic studies, gas chromatographic analysis of DEC in plasma can be complicated by the presence of the metabolite, since the thermally unstable DEC-N-oxide is converted back to a material which coelutes with DEC under the conditions of the analysis. We now report a method to separate DEC-N-oxide from DEC in plasma using solid phase extraction with subsequent gas chromatographic analysis using a nitrogen specific detector. One-diethylcarbamyl-4-ethylpiperazine (E-DEC) was the internal standard. The standard curve of DEC was linear in the range of 10 to 200 ng/ml as described by Y=0.0350+0.0128X, $R^2=0.999$. The limit of quantitation was 4 ng/mL. Reproducibility at 10, 100 and 200 ng/mL concentration points of the standard curve gave coefficient variations of 6.1%, 7.8% and 1.6%, respectively. The recovery following solid phase extraction was 99.3% for DEC and 94.8% for the internal standard. This sensitive and specific analytical method is suitable for pharmacokinetic studies of DEC.

  • PDF