• Title/Summary/Keyword: S-N Curves

Search Result 401, Processing Time 0.021 seconds

Improvement of HgCdTe Qualities grown by MOVPE using MBE grown CdTe/Si as Substrate (MBE법으로 성장된 CdTe(211)/Si 기판을 이용한 MOVPE HgCdTe 박막의 특성 향상)

  • Kim, Jin-Sang;Suh, Sang-Hee;Sivananthan, S.
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.282-288
    • /
    • 2003
  • We report the growth of HgCdTe by metal organic vapor phase epitaxy (MOVPE), using (211)B CdTe/Si substrates grown by molecular beam epitaxy (MBE). The surface morphology of these films is very smooth with hillock free. The etch pit densities (EPD) and full widths at half maximum (FWHM) of x-ray rocking curves exhibited that the crystalline quality of HgCdTe epilayer on MBE grown CdTe/Si was improved compare to HgCdTe on GaAs substrate. The Hall parameters of undoped HgCdTe layers on CdTe/Si showed n-type behavior with carrier concentration of $8{\times}10^{14}/cm^3$ at 77K. But HgCdTe on GaAs showed p-type conductivity due to in corporation of p-type impurities during GaAs substrate preparation. It is thought that these results are applicable for large area HgCdTe forcal plane arrays of $1024{\times}1024$ format and beyound.

Thermo-compression Bonding of Electrodes between RPCB and FPCB using Sn-Pb Solder (Sn-Pb 솔더를 이용한 경연성 인쇄 회로 기판간의 열압착 본딩)

  • Choi, Jung-Hyun;Lee, Jong-Gun;Yoon, Jeong-Won;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.3
    • /
    • pp.11-15
    • /
    • 2010
  • In this paper, we focused on the optimization of bonding conditions for the successful thermo-compression bonding of electrodes between the RPCB and FPCB with Sn-Pb solder. The peel strength was proportionally affected by the bonding conditions, such as pressure, temperature, and time. In order to figure out an optimized bonding condition, fracture energies were calculated through F-x (force-displacement) curves in the peel test. The optimum condition for the thermo-compression bonding of electrodes between the RPCB and FPCB was found to be temperature of $225^{\circ}C$ and time of 7 s, and its peel strength was 22 N/cm.

Ionic Dependence and Modulatory Factors of the Background Current Activated by Isoprenaline in Rabbit Ventricular Cells

  • Leem, Chae-Hun;Lee, Suk-Ho;So, In-Suk;Ho, Won-Kyung;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.26 no.1
    • /
    • pp.15-25
    • /
    • 1992
  • In order to elucidate the properties of the background current whole cell patch clamp studies were performed in rabbit ventricular cells. Ramp pulses of ${\pm}80\;mV$ from holding potential of 40 mV(or 20 mV) at the speed of 0.8 V/sec were given every 30 sec(or 10 sec) and current-voltage diagrams(I-V curve) were obtained. For the activation of the background current isoprenaline, adenosine 3',5'-cyclic monophosphate(dBcAMP), guanosine 3',5'-cyclic monophosphate(cGMP), and $N^6$-2'-o-dibutyryladenosine 3',5'-cyclic monophosphate(dBcAMP) were applied after all known current systems were blocked with 2mM Ba, 1 mM Cd ,5 mM Ni, 10 ${\mu}M$ diltiazem, 10 ${\mu}m$ ouabain, and 20 mM tetraethylammonium(TEA). The conductance of background current in control was $0.65{\pm}0.69$ nS at 0 mV, its I-V curves was almost linear and reversed near 50 mV. When there was no taurine in pipette solution, isoprenaline hardly activated the background current but when taurine existed in pipette solution, isoprenaline activated the larger background current. Cyclic AMP or cyclic GMP alone had little effect on the activation of the background current, while cGMP potentiated cGMP effect. When the background current was activated with cGMP and cAMP, isoprenaline could not further increased the background current. The background current activated by isoprenaline depended on extracellular $Cl^-$ concentration and its reversal potential was shifted according to chloride equilibrium potential. The change of extracellular $Na+$ concentration had little effect on reversal potential of the background current activated by isoprenaline.

  • PDF

Mesh Selectivity of the Gill Net for Anchovy, Engraulis japonica (멸치 자망의 망목선택성에 관하여)

  • SOHN Tae Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.6
    • /
    • pp.506-510
    • /
    • 1985
  • It is an important work to determine the mesh size of gill net for efficient catch. For investigating the suitable mesh size, the gill net for anchovy, Engraulis japonica was made and operated in the bay of Ulsan in July. 1983. The gill net for anchovy was composed of six different mesh size, 23.1mm (H=0.65), 21.6mm (H=0.65), 20.0mm (H=0.65), 23.1mm (H=0.55), 21.6mm (H=0.55) and 20.0mm(H=0.55). The parts of body caught by the gill net was examined, and the selectivity curves (for reference Ishida's method) with respect to the each mesh size were estimated using the data obtained through the operation of research gill net. The main results of this study are as follows: 1. The number of anchovy whose neck was in net was 148, more than $90\%$ of all, 161 2. The coefficient of relationship between the circumference of neck and the fork length were 0.70. 3. Fork length that the relative fishing efficiency of 23.1 mm mesh size (H=0.55) was maximum value was about 11.1 centimeter.

  • PDF

A Combined Random Scalar Multiplication Algorithm Resistant to Power Analysis on Elliptic Curves (전력분석 공격에 대응하는 타원곡선 상의 결합 난수 스칼라 곱셈 알고리즘)

  • Jung, Seok Won
    • Journal of Internet of Things and Convergence
    • /
    • v.6 no.2
    • /
    • pp.25-29
    • /
    • 2020
  • The elliptic curve crypto-algorithm is widely used in authentication for IoT environment, since it has small key size and low communication overhead compare to the RSA public key algorithm. If the scalar multiplication, a core operation of the elliptic curve crypto-algorithm, is not implemented securely, attackers can find the secret key to use simple power analysis or differential power analysis. In this paper, an elliptic curve scalar multiplication algorithm using a randomized scalar and an elliptic curve point blinding is suggested. It is resistant to power analysis but does not significantly reduce efficiency. Given a random r and an elliptic curve random point R, the elliptic scalar multiplication kP = u(P+R)-vR is calculated by using the regular variant Shamir's double ladder algorithm, where l+20-bit u≡rn+k(modn) and v≡rn-k(modn) using 2lP=∓cP for the case of the order n=2l±c.

Fabrication and Characterization of Spherical Carbon-Coated Li3V2(PO4)3 Cathode Material by Hydrothermal Method with Reducing Agent

  • Moon, Jung-In;Song, Jeong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.29 no.9
    • /
    • pp.519-524
    • /
    • 2019
  • Spherical $Li_3V_2(PO_4)_3$ (LVP) and carbon-coated LVP with a monoclinic phase for the cathode materials are synthesized by a hydrothermal method using $N_2H_4$ as the reducing agent and saccharose as the carbon source. The results show that single phase monoclinic LVP without impurity phases such as $LiV(P_2O_7)$, $Li(VO)(PO_4)$ and $Li_3(PO_4)$ can be obtained after calcination at $800^{\circ}C$ for 4 h. SEM and TEM images show that the particle sizes are $0.5{\sim}2{\mu}m$ and the thickness of the amorphous carbon layer is approximately 3~4 nm. CV curves for the test cell are recorded in the potential ranges of 3.0~4.3 V and 3.0~4.8 V at a scan rate of $0.01mV\;s^{-1}$ and at room temperature. At potentials between 3.0 and 4.8 V, the third $Li^+$ ions from the carbon-coated LVP can be completely extracted, at voltages close to 4.51 V. The carbon-coated LVP exhibits an initial specific discharge capacity of $118mAh\;g^{-1}$ in the voltage region of 3.0 to 4.3 V at a current rate of 0.2 C. The results indicate that the reducing agent and carbon source can affect the crystal structure and electrochemical properties of the cathode materials.

Estimation on Unsaturated Characteristic Curves of Tailings obtained from Waste Dump of Imgi Mine in Busan (부산 임기광산 폐석적치장 광미의 불포화 특성곡선 산정)

  • Song, Young-Suk;Kim, Kyeong-Su;Jeong, Sueng-Won;Lee, Choon-Oh
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.3
    • /
    • pp.47-58
    • /
    • 2014
  • To investigate the unsaturated characteristics of the tailings obtained from the waste dump at Imgi mine, matric suction and volumetric water content were measured in both drying and wetting processes using Automated Soil-Water Characteristics Curve Apparatus. Based on the measured result, Soil Water Characteristic Curves (SWCC) were estimated by van Genuchten model. According to the unsaturated soil classification method, the tailings of the waste dump correspond to clayey sand. As a result of Suction Stress Characteristic Curve (SSCC) by Lu and Likos model, SSCC has a shape of S which is similar to SWCC. The hysteresis phenomenon occurred in SSCCs, which means the suction stress of drying path is larger than that of wetting path in the same effective degree of saturation. The effective stress of unsaturated soil is equal to that of saturated soil when matric suction is less than Air Entry Value (AEV). However, the effective stress of unsaturated soil is larger than that of saturated soil when matic suction is more than AEV. Meanwhile, unsaturated hydraulic conductivity by van Genuchten model decreased with increasing matric suction, and the hydraulic conductivity of drying path is larger than that of wetting path.

DESIGN OF A CENTRIFUGAL BLOOD PUMP FOR ECMO DEVICE THROUGH NUMERICAL ANALYSES (수치해석을 통한 ECMO용 원심형 혈액 펌프 설계)

  • Choi, S.;Hur, N.;Moshfeghi, M.;Kang, S.;Kim, W.;Kang, S.H.
    • Journal of computational fluids engineering
    • /
    • v.21 no.1
    • /
    • pp.103-109
    • /
    • 2016
  • With the rapid increase in the number of patients with cardiopulmonary diseases, more cardiopulmonary circulatory assist devices are also needed. These devices can be employed when heart and/or lung function poorly. Due to the critical role they take, these devices have to be designed optimally from both mechanical and biomechanical aspects. This paper presents the CFD results of a baseline model of a centrifugal blood pump for the ECMO condition. The details of flow characteristics of the baseline model together with the performance curves and the modified index of hemolysis(MIH) are investigated. Then, the geometry of baseline impeller and the volute are modified in order to improve the biomechanical performance and reduce the MIH value. The numerical simulations of two cases represent that when impeller radius and prime volume decrease the MIH value also decreases. In addition, the modified geometry shows more uniform pressure distribution inside the volute. The findings provide valuable information for further modification and improvement of centrifugal blood pumps from both mechanical and biomechanical aspects.

Development of a method for the determination of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone in dust using liquld chromatography tandem mass spectrometry (LC-MS/MS를 이용하여 먼지 속의 NNK (4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone) 정량 분석법 개발)

  • Lee, W.K.;Kang, S.J.;Oh, J.E.;Hwang, S.H.;Lee, D.H.
    • Analytical Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), a tobacco specific nitrosamine found only in tobacco products. The ability to monitor biomarker concentrations is very important in understanding environmental tobacco smoke (ETS). In this study, an efficient and sensitive method for the analysis of NNK in dust was developed and validated using liquid chromatography tandem mass spectrometry. Dust was collected with filter paper soaked in methanol. The standard solution and dust sample were diluted with 100 mM ammonium acetate and extracted using dichloromethane. Our calibration curves ranged from 25 to $10^4pg/mL$. Excellent linearity was obtained with correlation coefficient values between 0.9996 and 1.0000. The limit of detection (LOD) was 5 pg/mL ($S/N{\geq}3$) and the retention time was 10 min. The limit of quantification (LOQ) was 25 pg/mL, and the acceptance criteria was the rate of 98-103% (80-120% at levels up to $3{\times}LOQ$). The coefficient of variations (CV) was 2.8%. Accuracies determined from dust samples spiked with four different levels of NNK racurves ranged that from 25 to 104 pg/mL. Excellent linearity was obtained between 92.1% and 114%. The precision of the method was acceptable (5% of CV). The recovery rates of the whole analytical procedure at low, medium, and high levels were 105.7-116.5% for NNK. The carry-over effects during LC-MS/MS analysis were not observed for NNK. This manuscript summarizes the scientific evidence on the use of markers to measure ETS.

Effect of Local Strain on Low Cycle Fatigue using ESPI System (ESPI System을 이용하여 측정한 국부 변형률이 저사이클 피로수명에 미치는 영향에 관한 연구)

  • Kim, Kyung-Su;Kim, Ki-Sung;Kwon, Jung-Min;Park, Seong-Mo;Kim, Beom-Il
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.2 s.146
    • /
    • pp.213-219
    • /
    • 2006
  • Low cycle fatigue cracks are mainly detected at discontinuous welded locations with high stresses under repeated cyclic static loads due to cargo leading and unloading. Theoretical and analytical methods have been used for evaluation of local stress and strain which have an effect on a prediction of fatigue life, but those have difficulties of considering stress concentration at notched location and complicated material behavior of welded joint or heat affected zone. Electronic speckle pattern interferometry(ESPI) system is nondestructive and non-contact measurement system which can get the relatively accurate full field strain at critical positions such as welded zone and structural discontinuous location. In this study, local strain was measured on welded cruciform joint by ESPI system and then low cycle fatigue test was performed. Effect of local strain on low cycle fatigue life was examined by measured values using ESPI system. Moreover, experimental fatigue life was compared with established S-N curves using theoretical local strain and stress calculated by Neuber's rule.