• Title/Summary/Keyword: S-N 법

Search Result 1,910, Processing Time 0.04 seconds

Analysis of stress distribution of tooth restored with metal-ceramic crown covering abfraction lesion according to its finish line location under occlusal load (금속도재관으로 수복된 Abfraction lesion이 있는 치아에 가해지는 교합력의 응력 분포 분석)

  • Kim, Jee-Hwan;Yoon, Chol-Wook;Kim, Taehyeon;Kim, Han-Sung;Woo, Dae-Gon;Lee, Keun-Woo;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.305-311
    • /
    • 2014
  • Purpose: When the full veneer crown was treated in the tooth with abfraction lesion due to various causes, the prognosis of it may be compromised according to the location of the finish line, but there is few study about the location of its buccal finish line. The purpose of this study was to investigate the effect of location of the finish line of the full veneer crown on stress distribution of the tooth with abfraction lesion. Materials and methods: The two dimensional finite element model was developed to express tooth, surrounding tissue and full veneer crown. The stress distribution under eccentric 144 N occlusal load was analyzed using finite element analysis. The location of finish line was set just at the lower border of the lesion (Group 0), 1 mm (Group 1) and 2 mm (Group 2) below the lower border of the lesion. Results: In the Group 0, von Mises stress was concentrated at the finish line and the apex of the lesion. Also, the stress at the bucal finish line propagated to the lingual side. In the Group 1 and Group 2, stress distribution was similar each other. Stress was concentrated at the apex of lesion, but the stress at the buccal finish line did not propagate to the lingual side. That implied decrease of the possibility of horizontal crown fracture. Conclusion: Full veneer crown alleviated the stress concentrated at the apex of the abfraction lesion, when the finish line of full veneer crown was set below the lower border of abfraction lesion.

Quantitative Analysis of t-Cinnamaldehyde of Cinnamomum cassia by $^1H-NMR$ Spectrometry ($^1H-NMR$을 이용한 계피의 t-cinnamaldehyde 정량분석)

  • Song, Myoung-Chong;Yoo, Jong-Su;Baek, Nam-In
    • Applied Biological Chemistry
    • /
    • v.48 no.3
    • /
    • pp.267-272
    • /
    • 2005
  • trans-Cinnamaldehyde, a major component of Cinnamomum cassia, was quantitatively analyzed using the $^1H-NMR$ spectrometry. Applicability of this method was confirmed through observing the variation of chemical shift in the $^1H-NMR$ spectrum of t-cinnamaldehyde and the integration value according to various sample concentrations or running temperatures. When the $^1H-NMR$ spectrometry was run for t-cinnamaldehyde (7.1429 mg/ml) at 19, 25, 30, 40 and $50^{\circ}C$, the chemical shifts of the doublet methine signal due to an aldehyde group were observed at 9.7202, 9.7184, 9.7169, 9.7142 and 9.7124 ppm, respectively, to imply that the running temperature had no significant variation in the chemical shift of the signal. The integration values of the signal were $1.37\;(19^{\circ}C),\;1.37\;(25^{\circ}C),\;1.37\;(30^{\circ}C),\;1.37(40^{\circ}C)$ and $1.37(50^{\circ}C)$, respectively, to also indicate running temperature gave no effect on the integration value. When the sample solutions with various concentrations such as 0.4464, 0.8929, 1.7857, 3.5714, 7.1429 and 14.286 mg/ml were respectively measured for the $^1H-NMR$ at $25^{\circ}C$, the chemical shifts of the aldehyde group were observed at 9.7206, 9.7201, 9.7196, 9.7192, 9.7185 and 9.7174 ppm. Even though the signal was slightly shifted to the high field in proportion to the increase of sample concentration, the alteration was not significant enough to applicate this method. The calibration curve for integration values of the doublet methine signal due to the aldehyde group vs the sample concentration was linear and showed very high regression rate ($r^2=1.0000$). Meantime, the $^1H-NMR$ spectra (7.1429 mg/ml $CDCl_3,\;25^{\circ}C$) of t-cinnamaldehyde and t-2-methoxycinnamaldehyde, another constituent of Cinnamomum cassia, showed the chemical shifts of the aldehyde group as ${\delta}_H$ 9.7174 (9.7078, 9.7270) for the former compound and ${\delta}_H$ 9.6936 (9.6839, 9.7032) for the latter one. The difference of the chemical shift between two compounds was big enough to be distinguished using the NMR spectrometer with 0.45 Hz of resolution. The contents of cinnamaldehyde in Cinnamomum cassia, which were respectively extracted with n-hexane, $CHCl_3$, and EtOAc, were determiend as 94.2 \;mg/g (0.94%), 137.6 mg/g (1.38%) and 140.1 mg/g(1.40%) t-cinnamaldehyde in each extract, respectively, by using the above method.

Assessment of Clinical Applicability of a New Plaque Scoring System Using Quantitative Light-Induced Fluorescence-Digital (Quantitative Light-Induced Fluorescence-Digital을 이용한 치면세균막 검사법의 임상적 활용 가능성 평가)

  • Hwang, Hye-Rim;Cho, Young-Sik;Kim, Baek-Il
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.150-157
    • /
    • 2014
  • The aim of this study was to suggest a convenient method of monitoring the gingival state through plaque detection. Quantitative Light-Induced Fluorescence-Digital (QLF-D), which can assess mature plaque, can be used to assess the oral hygiene status of individuals and to establish an adequate intervention plans for them. The subjects of the study participated in the clinical training at Department of Dental Hygiene, N University. The subjects completed questionnaires on general characteristics and oral hygiene methods. Then, photographs of maxillary and mandibular anterior teeth of the subjects were taken using the QLF-D. After the oral examinations, gingival state was recorded according to the $L{\ddot{o}}e$ & Silness's Gingival Index (GI). In addition, a plaque control record was calculated in percentage using disclosing agent. The analysis of the relation between the plaque control record and the QLF-D scores showed positive correlation (r=0.638, p<0.001), and the analysis of the relation between the QLF-D scores and the gingival bleeding index scores also showed positive correlation (r=0.562, p<0.001). Besides, the study classified the participants into healthy gingiva group and the gingivitis group according to the classification criteria of GI, and when the difference of QLF-D scores between the groups was analyzed, the QLF-D scores were statistically significantly higher (t=-2.785, p=0.007) in the gingivitis group ($1.71{\pm}1.545$) than the healthy gingiva group ($0.74{\pm}1.290$). When the differences in mean values of the QLF-D scores were analyzed against and the gingival bleeding index scores, the QLF-D scores of 0 and 1 belonged to the category of normal gingival state while the QLF-D scores of 2, 3 and 4 belonged to the category of gingivitis state. Therefore, it is deemed that the red fluorescence detected by the QLF-D from the mature supragingival plaque can be used for monitoring the state of gingivitis.

The Effect of Packing Method of Relining Material on the Flexural Strength of Denture Base Resin (첨상용 레진의 성형법이 의치상의 굴곡강도에 미치는 영향)

  • Kim, Min-Chul;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.197-207
    • /
    • 2011
  • The study aimed at examining how different reline resins affect flexural strength and flexural modulus of denture base. A total of 80 specimens ($64{\times}10{\times}3.3$ mm, according to ISO 1567:1999) of heat-polymerized resin, 40 specimens for (Lucitone199(Dentsply Int., NewYork, USA), SR Ivocap(Ivoclar AG, Schaan, Liechtenstein)) respectively, were polymerized according to the manufacturer's instructions and divided into eight groups(n = 10). Control group specimens remained intact. Specimens in the other groups were abraded on both sides to 2 mm thickness, and were relined in 1.3 mm thickness with 3 types of resins (Lucitone199(Dentsply), SR Ivocap(Ivoclar), and Rebase II(Tokuyama Co., Ltd, Tokyo, Japan)). All specimens were preserved in distilled water at $37^{\circ}C$ for 50 hours, and then were subjected to flexural strength testing in a universal testing machine using 3-point loading. A crosshead speed of 5 mm/min was used, and the distance between the supports was 50 mm. Data analyses included one-way analysis of variance(ANOVA) and the Tukey Honestly Significant Difference test (p=.05). Both heat-polymerized resin groups and auto-polymerized resin groups showed statistically low flexural strength and flexural modulus than control groups. Specimens relined with Lucitone 199 showed significantly higher flexural strength and flexural modulus than those relined with SR-Ivocap. Specimens relined with auto-polymerized resin showed significantly lower flexural strength and flexural modulus than those relined with heat-polymerized resin. Relining with heat-polymerized resins showed superior mechanical properties to relining with an auto-polymerized resin. Relining with the same heat-polymerized resin as the denture base does not affect mechanical properties of a denture. Lucitone199 using a compression-mould technique resulted in the highest flexural strength.

Application of Multiplex RT-PCR for Simultaneous Identification of Tomato Spotted Wilt Virus and Thrips Species in an Individual Thrips on Chrysanthemum (시설재배 국화에서 총채벌레의 종 동정 및 보독 바이러스 동시 검출을 위한 다중 진단법 적용)

  • Yoon, Ju-Yeon;Yoon, Jung-Beom;Seo, Mi-Hye;Choi, Seung-Kook;Cho, In-Sook;Chung, Bong-Nam;Yang, Chang Yeol;Gangireddygari, Venkata Subba Reddy
    • Research in Plant Disease
    • /
    • v.26 no.4
    • /
    • pp.264-271
    • /
    • 2020
  • We have developed a simultaneous diagnostic method that can identify both the species of thrips and tomato spotted wilt virus (TSWV) that are problematic in chrysanthemum plants. This is a method of amplifying DNA by performing reverse transcription-polymerase chain reaction by simultaneously adding primers specific to TSWV coat protein (N) gene and primers specific to the internal transcribed spacer 2 region of Frankliniella occidentalis and F. intonsa using total nucleic acid extracted from one thrips. The sizes of DNA fragments for TSWV, F. occidentalis, and F. intonsa were 777, 287, and 367 bp, respectively. These results showed species identification of thrips and whether thrips carrying TSWV can be simultaneously confirmed. Further usefulness of the simultaneous diagnostic method was made from greenhouse survey at chrysanthemum greenhouses in Taean (Chungcheongnam-do) and Changwon (Gyeongsangnam-do) to investigate the identification of thrips species and the rate of thrips carrying TSWV. Of thrips collected from the greenhouses, 83.7% thrips was F. occidentalis and 72.9% F. occidentalis carried TSWV in Taean. Similarly, the diagnostic method showed that 92.2% thrips was F. occidentalis and 84.0% F. occidentalis carried TSWV in Changwon. These results confirm that F. occidentalis is a dominant thrips species and the thrips species plays a crucial role in the transmission of TSWV in chrysanthemum plants in the greenhouses. Taken together, this study showed a simple diagnostic method for thrips identification and epidemiological studies of the timing and spread of TSWV through thrips in chrysanthemum greenhouses in South Korea.

Synthesis and luminescent properties of a new green $CaZrO_3:\;HO_{3+}$ long persistent phosphors (녹색 발광의 $CaZrO_3:\;HO_{3+}$ 축광성 형광체의 합성 및 발광 특성)

  • Park, Byeong-Seok;Choi, Jong-Keon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.18 no.3
    • /
    • pp.109-114
    • /
    • 2008
  • Novel green long persistent phosphors of $CaZrO_3$ : $HO_{3+}$ have been synthesized at high temperature with weak reduction atmosphere by traditional solid state reaction method. The role of $H_3BO_3$ as flux and the suitable concentration of Ho as activator on the $CaZrO_3$ : $HO_{3+}$ long persistent phosphors has been investigated. Crystals of $HO_{3+}$ doped $CaZrO_3$ long persistent phosphores were characterized by fluorescence spectrophotometer and photoluminescence (PL). The main emission spectra of 546 nm peak was revealed through synthesizing at high temperature in $N_2$ gas atmosphere. The after glow emission spectra of $CaZrO_3$ : $HO_{3+}$ long persistent phosphores arise at 546 nm peak of narrow range. because that revealed pure green color. Green long persistent phosphors have been observed in the system for over 5 h after UV irradiation (254 nm). The main emission peak was ascribed to $HO_{3+}$ ions transition from $^5F_4$, $^5S_2{\to}^5I_3$, and the after glow may be ascribed to the trap centers in the $CaZrO_3$ host lattice.

Electronic Structure and Elemental Composition of the Lead Sulfide Colloidal Quantum Dots Depending on the Types of Ligand and Post-Treatment (리간드 종류와 후처리 공정에 따른 황화납 콜로이드 양자점 박막의 전자 구조 및 원소 조성 분석)

  • Kim, Tae Gun;Choi, Hyekyoung;Jeong, Sohee;Kim, Jeong Won
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.6
    • /
    • pp.402-409
    • /
    • 2016
  • Thin films of lead sulfide colloidal quantum dots (CQDs) of 2.8 nm in diameter are fabricated and their surfaces are passivated by 3-mercaptopropionic acid (MPA) ligand or hybrid type ($MPA+CdCl_2$) ligand, respectively. The changes in valence band electronic structure and atomic composition of each PbS CQD film upon post-treatment such as air, N2 annealing or UV/Ozone have been studied by photoelectron spectroscopy. The air annealing makes the CQD fermi level to move toward the valence band leading to "p-type doping" regardless of ligand type. The UV/Ozone post-treatment generates $Pb(OH)_2$, $PbSO_x$ and PbO on both CQD surfaces. But the amount of the PbO has been reduced in hybrid type ligand case, especially. That is probably because the extra Pb cations in (111) surface are additionally passivated by $Cl_2$ ligand, which limits the reaction between the Pb cation and ozone.

A Study on the Moisture Evaporation and Property Change Depending on the Composting Temperature for the Escalator Reversing Composting System (기계교반 퇴비화시설에서의 구간별 발효온도에 따른 수분 증발량 및 특성 변화 연구)

  • Kwag J. H.;Choi D. Y.;Park C. H.;Jeong K. H.;Kim J. H.;Kang H. S.;Yang C. B.;La C. S.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.3
    • /
    • pp.163-168
    • /
    • 2004
  • This research was carried out to investigate the moisture evaporation and property change depenging on the composting temperature for the escalator reversing composting system. The system was supported by the Y livestock cooperative composting factory. According to the test, the composting remperature eas varied in the range of $65\~80^{\circ}C$. The water content was de-creased to $75\%$ and became about $60\%$ at the end of the phase. Total nitrogen became $0.58\%$, total phosphoric acid $1.47\%$ and potashium $0.49\%$ at the end of the phase.

  • PDF

Water Budget Analysis of Four big river basin based on K-WEAP (K-WEAP을 이용한 4대 권역별 물 수지 분석)

  • Moon, Jang-Won;Choi, Si-Jung;Lee, Dong-Ryul;Yoon, Seok-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1362-1366
    • /
    • 2006
  • 우리나라에서는 하천법 제11조에 의거하여 10년마다 한 번씩 수자원장기종합계획을 수립하고 있으며, 필요에 따라 5년마다 이를 수정 보완하고 있다. 2001년 7월 수자원장기종합계획(Water Vision 2020)이 수립된 이후 잦은 봄 가뭄 등 이수측면에서의 사회, 경제, 환경의 변화와 최근 이상홍수 등으로 인한 대규모 홍수피해 발생에 따른 치수측면의 종합적인 대책의 제시가 요구되면서 2001년 수립된 계획에 대한 보완 필요성이 제기되었다. 또한 수자원계획의 신뢰성에 대한 시민단체 등의 문제제기와 지역 차원의 수자원계획 및 수자원환경에 대한 국민적 관심 증대로 인해 계획 수립 과정과 결과에 대한 국민적인 공감대 형성을 위한 체제의 구축이 금번 보완 계획의 수립을 통해 추진되고 있다. 금번 수자원장기종합계획 보완은 투명성 확보라는 큰 목표를 가지고 수행되고 있으며, 이를 통해 국가 수자원 관리의 청사진을 제시하고 물 수급 전망 및 용수수급 계획을 수립하는 과정에 있다. 기 개발된 한국형 통합수자원평가계획 모형인 K-WEAP 모형을 보완 계획 수립 과정에서 활용하고 있으며, K-WEAP 모형을 통해 물 수지 분석을 수행하여 수급 균형을 판단함으로써 일반 대중에게 물 수급 관련 상황에 대한 이해력을 높일 수 있다는 장점을 확보할 수 있다. 본 연구에서는 K-WEAP 모형을 이용하여 각 권역별로 2003년의 물 수급 현황을 분석하여 이를 하천의 관측유량과 비교해봄으로써 모형의 검증을 수행하였으며, 각 권역에서 시나리오별로 추정된 용수수요량을 이용하여 물 수지 분석을 수행함으로써 목표연도별 물 수급 분석결과를 제시하였다. 물 수급 분석 시 지하수 및 농업용 저수지 등 하천과 다목적댐 이외의 지역 공급원에 대해서도 고려하였으며, 이를 통해 수자원계획 수립 시 도움이 될 수 있는 기초적인 자료를 제공할 수 있었다. 인공순환에 의한 저감효과가 크지는 않을 것으로 예측된다. 조사 기간중 H호의 현존 식물플랑크톤량의 $60%{\sim}87%$가 수심 10m 이내에 분포하였고, 녹조강과 남조강이 우점하는 하절기에는 5m 이내에 주로 분포하였다. 취수탑 지점의 수심이 연중 $25{\sim}35m$를 유지하는 H호의 경우 간헐식 폭기장치를 가동하는 기간은 물론 그 외 기간에도 취수구의 심도를 표층 10m 이하로 유지 할 경우 전체 조류 유입량을 60% 이상 저감할 수 있을 것으로 조사되었다.심볼 및 색채 디자인 등의 작업이 수반되어야 하며, 이들을 고려한 인터넷용 GIS기본도를 신규 제작한다. 상습침수지구와 관련된 각종 GIS데이타와 각 기관이 보유하고 있는 공공정보 가운데 공간정보와 연계되어야 하는 자료를 인터넷 GIS를 이용하여 효율적으로 관리하기 위해서는 단계별 구축전략이 필요하다. 따라서 본 논문에서는 인터넷 GIS를 이용하여 상습침수구역관련 정보를 검색, 처리 및 분석할 수 있는 상습침수 구역 종합정보화 시스템을 구축토록 하였다.N, 항목에서 보 상류가 높게 나타났으나, 철거되지 않은 검전보나 안양대교보에 비해 그 차이가 크지 않은 것으로 나타났다.의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에 있어서 시장수익률을 평균적으로 초과할 수 있는 거래전략은 존재하므로 이러한 전략을 개발 및 활용할 수 있으며, 특히, 한국주

  • PDF

The Establishment and Application of Very Short Range Forecast of Precipitation System (초단시간 강수예보시스템 구축 및 활용)

  • Choi, Ji-Hye;Nam, Kyung-Yeub;Suk, Mi-Kyung;Choi, Byoung-Cheol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1515-1519
    • /
    • 2006
  • 본 연구에서는 초단시간 강수예보(VSRF, Very Short-Range Forecast of precipitation) 시스템 구축 현황을 소개하고자 한다. VSRF 모델은 레이더 반사도 자료와 지상 AWS 자료를 이용하여 레이더-AWS 강우강도를 산출하는 강수분석과정과 분석된 강수량 자료와 중규모 수치예보장을 사용하여 외삽법에 의한 초단시간 강수예보를 수행하는 예보과정, 실시간으로 산출된 강수예보 자료를 검증하고 홈페이지에 제공하는 자료지원과정으로 구성된다. 본 연구에서는 모델의 예보능력을 향상시키기 위해 크게 두 가지 측면에서 모델을 개선하였다. 첫째는 모델의 입력자료인 레이더-AWS 강우강도 자료를 기상연구소 원격탐사연구실에서 운영하던 WPMM (Window Probability Matching Method)과 기상청 기상레이더과에서 운영하던 RQPE(Radar Quantitative Precipitation Estimation)의 알고리즘을 통합하여 정확한 강우강도 자료인 레이더-AWS 강우강도(RAR, Radar-AWS Rain rate) 시스템을 구축하여 개선하였으며, 둘째는 외삽과정을 통한 예보가 3시간이 지나면 예측능력이 감소하는 문제점을 보완하기 위해 현업 중규모 모델(RDAPS, Regional Data Assimilation and Prediction System)의 예측강수와 병합하여 모델을 개선하였다. 또한 이를 시계열 검증 및 공간 검증하는 실시간 검증 시스템을 구축하여 실시간으로 모델의 정확성을 평가하고 있다. 그 결과 입력자료 개선을 통한 모델의 정확도는 크게 향상된 결과는 볼 수 없었지만 미약하게 향상된 것을 확인할 수 있었으며, 모델의 병합을 통한 모델의 개선은 예측 3시간 이후부터는 50% 정도 향상되었다.의 대안을 제시하고자 한다.X>${\mu}_{max,A}$는 최대암모니아 섭취률을 이용하여 구한 결과 $0.65d^{-1}$로 나타났다.EX>$60%{\sim}87%$가 수심 10m 이내에 분포하였고, 녹조강과 남조강이 우점하는 하절기에는 5m 이내에 주로 분포하였다. 취수탑 지점의 수심이 연중 $25{\sim}35m$를 유지하는 H호의 경우 간헐식 폭기장치를 가동하는 기간은 물론 그 외 기간에도 취수구의 심도를 표층 10m 이하로 유지 할 경우 전체 조류 유입량을 60% 이상 저감할 수 있을 것으로 조사되었다.심볼 및 색채 디자인 등의 작업이 수반되어야 하며, 이들을 고려한 인터넷용 GIS기본도를 신규 제작한다. 상습침수지구와 관련된 각종 GIS데이타와 각 기관이 보유하고 있는 공공정보 가운데 공간정보와 연계되어야 하는 자료를 인터넷 GIS를 이용하여 효율적으로 관리하기 위해서는 단계별 구축전략이 필요하다. 따라서 본 논문에서는 인터넷 GIS를 이용하여 상습침수구역관련 정보를 검색, 처리 및 분석할 수 있는 상습침수 구역 종합정보화 시스템을 구축토록 하였다.N, 항목에서 보 상류가 높게 나타났으나, 철거되지 않은 검전보나 안양대교보에 비해 그 차이가 크지 않은 것으로 나타났다.의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에

  • PDF