• Title/Summary/Keyword: S-N곡선

Search Result 324, Processing Time 0.029 seconds

Evaluation of Purification Capacity of Vegetable Lactobacillus fermentum Culture System in Closed Environmental Waste Water (식물성 유산균 혼합물을 활용한 환경 폐수의 정화능력 평가)

  • Lee, Deuk Sik;Kim, Nam Kyun;Shim, Sooyong;Lee, Dong Jin;Yoon, Won Byong
    • Food Engineering Progress
    • /
    • v.15 no.1
    • /
    • pp.22-27
    • /
    • 2011
  • Changes in total nitrogen (T.N.) and total phosphate (T.P.) content in environmental waste water upon the reaction of biological purifying reagents were measured and the reaction rate was evaluated. The purification capacity of two biological purifying reagents composed of vegetable Lactobacillus fermentum (V.L.F.), Saccharomyces cerevisiae(S.C), and Bacillus subtilis(B.S.) were evaluated and compared with that of commercial water purification system operating by local government. After 18days of reaction, the mixture of V.L.F. and S.C. showed dramatic decrease of T.N.(36.21% of the initial value). The mixture of V.L.F., S.C., and B.S. showed faster reaction rate to decrease T.P. compared with that of the mixture of V.L.F. and S.C. The reaction constant of mixture of V.L.F. and S.C. was estimated to be 0.178 $day^{-1}$ by the curve fitting of the data of changes in T.N. during the reaction.

A Study on the Reduction of Non-Point Source Pollution loads from Small Agricultural Watershed by Applying Surface Covering Scenario using HSPF Model (HSPF 모델을 이용한 지표피복 시나리오 적용에 따른 농촌 소유역에서의 비점원오염 저감연구)

  • Jung, Chung-Gil;Park, Jong-Yoon;Kim, Sang-Ho;Kim, Seong-Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.103-103
    • /
    • 2012
  • 본 연구에서는 시험포장($1276.6m^2$)에서의 지표피복 BMPs (Best Management Practices) 시나리오를 적용하여 얻은 평균 유출저감율을 HSPF 모델에 적용하여 유역차원에서의 비점원오염 저감효과를 평가하고자 한다. 본 연구에서는 별미천 유역($1.21km^2$)을 대상으로 모형의 적용을 위한 입력자료로 기상자료와 지형자료를 구축하였으며 기상자료로 수원, 양평, 이천 기상관측소 자료를 구축하였으며, 지형자료로 격자크기 2m의 DEM (Digital Elevation Model)과 토지이용도는 2006년 5월 1일 QuickBird 영상을 제공받아 기존 환경부, 건교부, USGS의 토지피복분류체계 및 현장조사를 통하여 QuickBird 영상으로부터 추출 가능한 정밀농업정보에 대한 항목을 결정하였으며, 정사보정된 QuickBird 영상을 스크린 디지타이징 기법(On-Screen Digitizing Method)을 이용하여 총 21개 토지이용항목의 정밀토지이용도를 구축하였다. 실제모니터링으로 측정된 자료를 바탕으로 수위-유량곡선 산정 및 오염부하곡선을 선정, 2011년 6월 8일부터 10월 31일 분석기간으로 HSPF 모델링을 실시하였으며 모의결과 월별 통계에 따른 적용성 분석으로 RMSE (Root Mean Square Error) 는 1.15 ~ 1.76(mm/day), $R^2$는 0.62 ~ 0.78, Nash-Sutcliffe model efficiency (NSE)는 0.62 ~ 0.76로 모의치는 실측치와 유의성이 있는 것으로 분석되었다. 또한, Sediment, T-N, T-P의 $R^2$는 각각 0.72, 0.62, 0.63으로 상관성을 보이는 것으로 분석되었다. 시험포장으로부터 얻어진 event별 볏짚을 이용한 지표피복시나리오적용 후 밭에서의 평균 유출 약 10 % 유출율 감소 조건과 실제 평균 비점원오염 저감효과 89.7 % ~ 99.4 %의 결과로부터 지표피복효과의 침투효과를 HSPF 모델로 적용하기 위해 침투량(INFILT)를 조절하여 평균유출 약 10 %가 감소되는 16.0 mm/hr 값을 선정하였다. 그 결과, Sediment. T-N, T-P의 평균 저감율은 각각 87.2 %, 28.5 %, 85.1 %로 나타났으며 이는 시험포장에서의 실제 평균 비점오염 저감효과 89.7 % ~ 99.4 %에 근접함을 알 수 있었다. 이 결과로부터 침투량 조절에 따른 지표피복(침투짚단)효과는 Sediment, T-P에서 저감효율이 80 % 이상으로 높았지만 T-N은 약 30 %로 낮은 저감율을 보임으로써 저감효과가 크지 않음을 나타냈다.

  • PDF

Fatigue Safe Life Analysis of Helicopter Bearingless Rotor Hub Composite Flexbeam (헬리콥터 무베어링 로터 허브 복합재 유연보 피로 안전수명 해석)

  • Kim, Taejoo;Kee, Youngjoong;Kim, Deog-Kwan;Kim, Seung-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.7
    • /
    • pp.561-568
    • /
    • 2013
  • After we designed Bearingless rotor hub system for 7,000lb class helicopter, flexbeam fatigue analysis was conducted for validation of requirement life time 8,000 hours. sectional structural analysis method applying elastic beam model was used. Fatigue analysis for two sections of flexbeam which were expected to weak to fatigue damage from result of static analysis was conducted. Extension, bending and torsion stiffness of flexbeam section shape was calculated using VABS for structure analysis. S-N curve of two composite material which composed flexbeam was generated using wohler equation. Load analysis of bearingless rotor system was conducted using CAMRAD II and load analysis result was applied HELIX/FELIX standard load spectrum to generate bearingless rotor system load spectrum which was used flexbeam fatigue safe life analysis.

A Study of Parametric Effects on the Thermal Performance of Flat-Plate Liquid-Heating Solar Collectors (평판형 액체식 집열기 의 각종 변수 가 집열기 의 열성능 에 미치는 영향)

  • 전문헌;윤석범;추교명
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.145-153
    • /
    • 1984
  • In the present work, a computer simulation is performed employing Hottel-Whillier-Bliss model for thermal performance of solar collectors. The major collector parameters examined in the computer simulation are: number of transparent glass covers(N), thermal emissivity of the absorbing plate surface (.epsilon.$_{P}$), absorptivity of absorber plate (.alpha.$_{p}$), flow rate per unit area of collector (G), $L_{b}$ / $k_{b}$ of insulation material, tilt angle of collector (S), and solar insolation(I). By varying numerical values of the major collector parameters around their typical values, the corresponding variations in thermal efficiency curves are examined. In addition, an experimental investigation has been carried out with a slightly modified KAIST collector test loop under a real sun condition in order to compare with the simulation results, examine the applicability of the mathematical model of the collector thermal performance, and study the effect of variation of flow rate (G) on thermal efficiency and the range of optimum flow rate.e.

Classification models for chemotherapy recommendation using LGBM for the patients with colorectal cancer

  • Oh, Seo-Hyun;Baek, Jeong-Heum;Kang, Un-Gu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.7
    • /
    • pp.9-17
    • /
    • 2021
  • In this study, we propose a part of the CDSS(Clinical Decision Support System) study, a system that can classify chemotherapy, one of the treatment methods for colorectal cancer patients. In the treatment of colorectal cancer, the selection of chemotherapy according to the patient's condition is very important because it is directly related to the patient's survival period. Therefore, in this study, chemotherapy was classified using a machine learning algorithm by creating a baseline model, a pathological model, and a combined model using both characteristics of the patient using the individual and pathological characteristics of colorectal cancer patients. As a result of comparing the prediction accuracy with Top-n Accuracy, ROC curve, and AUC, it was found that the combined model showed the best prediction accuracy, and that the LGBM algorithm had the best performance. In this study, a chemotherapy classification model suitable for the patient's condition was constructed by classifying the model by patient characteristics using a machine learning algorithm. Based on the results of this study in future studies, it will be helpful for CDSS research by creating a better performing chemotherapy classification model.

Finite element analysis of peri-implant bone stress influenced by cervical module configuration of endosseous implant (임플란트 경부형상이 주위골 응력에 미치는 영향에 관한 유한요소법적 분석)

  • Chung, Jae-Min;Jo, Kwang-Heon;Lee, Cheong-Hee;Yu, Won-Jae;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.394-405
    • /
    • 2009
  • Statement of problem: Crestal bone loss, a common problem associated with dental implant, has been attributed to excessive bone stresses. Design of implant's transgingival (TG) part may affect the crestal bone stresses. Purpose: To investigate if concavely designed geometry at a dental implant's TG part reduces peri-implant bone stresses. Material and methods: A total of five differently configured TG parts were compared. Base model was the ITI one piece implant (Straumann, Waldenburg, Switzerland) characterized by straight TG part. Other 4 experimental models, i.e. Model-1 to Model-4, were designed to have concave TG part. Finite element analyses were carried out using an axisymmetric assumption. A vertical load of 50 N or an oblique load of 50 N acting at $30^{\circ}$ with the implant's long axis was applied. For a systematic stress comparison, a total of 19 reference points were defined on nodal points around the implant. The peak crestal bone stress acting at the intersection of implant and crestal bone was estimated using regression analysis from the stress results obtained at 5 reference points defined along the mid plane of the crestal bone. Results: Base Model with straight configuration at the transgingival part created highest stresses on the crestal bone. Stress level was reduced when concavity was imposed. The greater the concavity and the closer the concavity to the crestal bone level, the less the crestal stresses. Conclusion: The transgingival part of dental implant affect the crestal bone stress. And that concavely designed one may be used to reduce bone stress.

Analysis of the Maximum Heat Release Rate in Accordance with the Test Method of the Flame Retardant Performance for Pipe Insulation (배관용 보온재의 난연 성능 시험방법에 따른 최대 발열량 분석)

  • You, Woo Jun;Park, Jung Wook;Sin, Yeon Je;Park, Hyeong Gyu;Lim, Ohk Kun
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.18-25
    • /
    • 2020
  • In this study, the heat release rate of pipe insulation is analyzed by considering the installation status in accordance with the standards ISO 20632 and NFPA 274. The flame retardation rate was evaluated for six types of test samples: polyethylene foam covered with beaten silver (PE(S)), PE foam tapped (PE(N)), elastomeric closed cell thermal insulation (rubber), Japanese PE foam (PE(J)), Japanese polyurethane foam (PU(J)), and Japanese styro form (ST(J)) by EN 13501-1 and fire growth curve. The results show that PU(J), PE(J), and PE(N) were Class E and ultra-fast, NFPA 274 test standards for Class D and Fast, and PE(S) by ISO 20632 were Class C and Slow, and Rubber and ST(J) were Classes and Low. However, the changes in the time-averaged maximum heat release rate for each test standard (ISO 20632 and NFPA 274) to evaluate the flame retardation rate differed among identical materials. This means that the fundamental study is necessary to analyze the more accurate reasons.

Effect of KOH Activation on Electrochemical Behaviors of Graphite Nanofibers (KOH 활성화 효과에 의한 흑연나노섬유의 전기화학적 거동)

  • Yoo, Hye-Min;Min, Byung-Gak;Lee, Kyu-Hwan;Byun, Joon-Hyung;Park, Soo-Jin
    • Polymer(Korea)
    • /
    • v.36 no.3
    • /
    • pp.321-325
    • /
    • 2012
  • In this work, we prepared the activated graphite nanofibers (A-GNFs) via chemical activation with KOH/GNFs ratios in a range of 0 to 5. The effect of KOH activation was studied in the surface and pore properties of the samples for electrochemical performance. The surface properties of A-GNFs were characterized by XRD and SEM measurements. The textural properties of the A-GNFs were investigated by $N_2$/77 K adsorption isotherms using Brunauer-Emmett-Teller (BET) equation. Their electrochemical behaviors were investigated by cyclic voltammetry and galvanostatic charge-discharge performance. From the results, electrochemical performances of the A-GNFs were improved with increasing the ratio of KOH reagent. It was found that specific surface area and total pore volume of the A-GNFs were increased by KOH activation.

Assessment and Recommendation of Fatigue Design Codes for Stud Shear Connectors in Composite Bridge (강합성 교량 스터드 전단연결재의 피로 설계식 평가 및 제안)

  • Lee, Kyoung-Chan;Yoon, Ki-Yong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.15-21
    • /
    • 2009
  • The design of the stud shear connector of a bridge structure is mostly controlled by the fatigue resistance not by the strength, if it is followed by AASHTO LRFD Bridge Design Specification. This fatigue design code in AASHTO LRFD is based on the research work done by Slutter and Fisher in 1966. These tests seemingly underestimated the fatigue resistance of connectors because of the inherent eccentricity of the one-face test setup which results additional tension forces to the stud. In addition, the stress ranges were not plotted in the log scale, because it was not known at that time that the fatigue resistance of the welded steel structures has a linear relationship of log scales of stress range and number of loading cycles. This study evaluates the test data produced by the Slutter and Fischer, and plot the data on the proper manner. The fatigue push-out test data produced recently by many other researches all around the world are gathered and analyzed, furthermore a design curve is recommended.

Determination of carbaryl in aqueous solution by fluorescence spectrometry (형광분광법을 이용한 수용액 중의 carbaryl의 정량)

  • Kim, Wook Hyun;Lee, Sang Hak
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.307-312
    • /
    • 2009
  • A spectrofluorimetric methods has been developed for the determination of carbaryl in an aqueous solution. The effects of excitation wavelength, concentration of surfactant, concentration of ethanol as cosurfactant and emission wavelength on the fluorescence intensity were investigated to find the optimum experimental conditions to determine carbaryl. The emission intensity of the carbayl was increased with addition of sodium dodecyl sulfate (SDS) as a surfactant. The emission intensity of the carbaryl was further increased with addition of ethanol as a co-surfactant. The optimum conditions were 281 nm for excitation wavelength, $1.0{\times}10^{-2}mol/L$ SDS, 20% (v/v) ethanol and 349 nm for emission wavelength. Under the optimum conditions, the emission intensity increased with the carbaryl concentration in the range of $5{\times}10^{-7}$ to $1.0{\times}10^{-4}mol/L$ with a detection limit ($3{\sigma}$) of $1.1{\times}10^{-8}mol/L$. The resulting correlation coefficient of the working curve was 0.9996.