• 제목/요약/키워드: S-Glass

검색결과 2,850건 처리시간 0.031초

COG 압착 공정에서의 Glass 휨 연구 (Investigation for glass warpage in the COG process)

  • 김병용;김종환;최성호;오용철;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.300-301
    • /
    • 2006
  • We studied about new module technology to solve warpage problems that produce bending of cell in the LCD (Liquid crystal display). Characteristics of cell gap and glass bending of applying heat Panel's PAD part and cell at various temperature was investigated. When applies heat and compresses PAD party only in case of compressing COG(Chip on Glass), uniformity of cell gap that happen by glass bending by temperature of these compressing COG In the PAD party is decreased. However, in case of compress COG. glass bending of applying heat Panel's PAD part and cell at various temperature produced 20um. But, uniformity of cell gap was not decreased. Therefore, it is considered that applying heat Panel's PAD part and cell could decrease uniformity of cell gap and bending of glass.

  • PDF

헬륨가스 주입식 유리섬유 냉각장치의 냉각성능 해석 (COMPUTATIONAL ANALYSIS ON THE COOLING PERFORMANCE OF GLASS FIBER COOLING UNIT WITH HELIUM GAS INJECTION)

  • 오일석;김동주;우마로프 알리세르;곽호상;김경진
    • 한국전산유체공학회지
    • /
    • 제16권4호
    • /
    • pp.110-115
    • /
    • 2011
  • A modern optical fiber manufacturing process requires the sufficient cooling of glass fibers freshly drawn from the heated and softened silica preform in the furnace, since the inadequately cooled glass fibers are known to cause improper polymer resin coating on the fiber surface and to adversely affect the product quality of optical fibers. In order to greatly enhance the fiber cooling effectiveness at increasingly high fiber drawing speed, it is necessary to use a dedicated glass fiber cooling unit with helium gas injection between glass fiber drawing and coating processes. The present numerical study features a series of three-dimensional flow and heat transfer computations on the cooling gas and the fast moving glass fiber to analyze the cooling performance of glass fiber cooling unit, in which the helium is supplied through the discretely located rectangular injection holes. The air entrainment into the cooling unit at the fiber inlet is also included in the computational model and it is found to be critical in determining the helium purity in the cooling gas and the cooling effectiveness on glass fiber. The effects of fiber drawing speed and helium injection rate on the helium purity decrease by air entrainment and the glass fiber cooling are also investigated and discussed.

광섬유 고속생산용 헬륨 주입식 유리섬유 냉각공정에 대한 열유동 해석 (THERMO-FLUID ANALYSIS ON THE HELIUM INJECTION COOLING OF GLASS FIBER FOR HIGH SPEED OPTICAL FIBER MANUFACTURING)

  • 오일석;김동주;곽호상;김경진
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.92-95
    • /
    • 2011
  • In manufacturing optical fibers, the process starts with the glass fiber drawing from the heated and softened silica preform in the furnace, and the freshly drawn glass fiber is still at high temperature when it leaves the glass fiber drawing furnace. It is necessary to cool down the glass fiber to the ambient temperature before it then enters the fiber coating applicator, since the hot glass fiber is known to cause several technical difficulties in achieving high quality fiber coating. As the fiber drawing speed keeps increasing, a current manufacturing of optical fibers requires a dedicated cooling unit with helium gas injection. A series of three-dimensional flow and heat transfer computations are carried out to investigate the effectiveness of fiber cooling in the fiber cooling unit. The glass fiber cooling unit is simplified into the long cylindrical enclosure at which the hot glass fiber passes through at high speed, and the helium is being supplied through several injection slots of rectangular shape along the cooling unit. This study presents and discusses the effects of helium injection rates on the glass fiber cooling rates.

  • PDF

레이저 웰딩 기술을 이용한 ECL용 유리 기판 접합에 대한 고찰 (Investigation of Glass Substrate Sealing for ECL Application using Laser Welding Technology)

  • 성열문
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.28-32
    • /
    • 2015
  • In this work, we reported fabrication of sealing the glass substrate using laser treatment at low temperature for electrochemical luminescence (ECL) cell. The laser treatment at temperature is using laser diode. The glass substrate sealing by laser treatment tested at 3-10W, 2-5 mm/s for build and tested. The sealing laser treatment method will allow associate coordination between the two glass substrate was enclosed. The effect of laser treatment to sealing the glass substrate was found to have cracks and air gap at best thickness of about 550-600 im for condition 3 W, 3 mm/s. The surface of sealing was roughness which was not influent to electrodes It can reduce the cracks, crevices and air gaps as well, improves the performance viscosity in butter bus bar electrodes. Therefore, it is more effective viscosity between two FTO glasses substrate.

직물형 유리섬유/에폭시 프리프레그로 피막된 판유리의 강구 충격 파괴 거동 (Steel-Ball-Impact fracture Behavior of Soda-Lime Glass Plates Bonded with Glass Fabric/Epoxy Prepreg)

  • 김형구;최낙삼
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 춘계학술발표대회 논문집
    • /
    • pp.20-25
    • /
    • 2000
  • In order to study the impact fracture behavior of brittle materials, a steel-ball-impact experiment was Performed. Five kinds of materials were used in this study : soda-lime glass plates, glass/epoxy prepreg-one layer-bonded and unbonded glass plates, glass/epoxy prepreg-three layers-bonded and unbonded glass plates. Fracture patterns, the maximum stress and absorbed fracture energy were observed according to various impact velocities 40-120m/s. With increasing impact velocity, ring crack, cone crack, radial crack and lateral crack took place in the interior of glass plates. The generation of such cracks was largely reduced with glass/epoxy prepreg coating. Consequently, it is thought that the characteristics of the dynamic Impact fracture behavior could be evaluated using the absorbed fracture energy and the maximum stress measured at the back surface of glass plates.

  • PDF

다축 구조 S-2 유리섬유 복합재의 충격 특성 (Impact Properties of S-2 Glass Fiber Composites with Multi-axial Structure)

  • 송승욱;이창훈;변준형;황병선;엄문광;이상관
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.71-75
    • /
    • 2005
  • For the damage tolerance improvement of conventional laminated composites, stitching process have been utilized for providing through-thickness reinforcements. 2D preforms were stacked with S-2 glass plain weave and S-2 glass MWK (Multi-axial Warp Knit) L type. 3D preforms were fabricated using the stitching process. All composite samples were fabricated by RTM (Resin Transfer Molding) process. To examine the damage resistance performance the low speed drop weight impact test has been carried out. For the assessment of damage after the impact loading, specimens were examined by scanning image. CAI (Compressive After Impact) tests were also conducted to evaluate residual compressive strength. Compared with 2D composites, the damage area of 3D composites was reduced by 20-30% and the CAI strength showed 5-10% improvement.

  • PDF

Glass Infiltration법에 의한 $Al_2O_3$/Glass/$Al_2O_3$ 세라믹스의 소결거동 및 유전특성 (Sintering Behavior and Dielectric Properties of $Al_2O_3$/Glass/$Al_2O_3$ Ceramics by Glass Infiltration)

  • 조태진;여동훈;신효순;홍연우;김종희;조용수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.177-177
    • /
    • 2009
  • 이동통신 시스템의 소형화 경량화 다기능화 추세에 따라 세라믹 모듈의 정밀도 및 집적도가 중요한 요소로 부각되고 있다. 이러한 모듈의 고집적화 추세에 대응하기 위하여 세라믹 소성시 수축율 제어가 필수적인 요소로 부각되고 있으며, 이에 따라 X, Y축의 소성 수축율을 0에 근접하게 제어하는 무수축 소성 기술이 요구되고 있다. 선행연구를 통하여 $Al_2O_3$/Glass/$Al_2O_3$ 구조의 glass infiltration법에 의한 무수축 소성 기술 구현 가능성을 확인하였으나, 아직 해결해야 할 문제점들이 있다. glass가 $Al_2O_3$층으로 infiltration되는 과정에서 glass층이 de-lamination 되는 결함이 발견되었으며 이는 유전체 기판의 Q값을 낮추고 기판의 신뢰성에 악영향을 줄 수 있어 이에 대한 개선이 필요한 실정이다. 본 연구에서는 $Al_2O_3$/Glass/$Al_2O_3$ 구조의 glass infiltration법에 의한 선행 실험에서 관찰된 기판 내부의 de-lamination 현상에 대한 원인을 규명하고 해결책을 제시하고자 하였다. glass 유동과 바인더 burn-out이 동시에 진행됨에 따라 기공이 생성되며 glass가 점성유동함에 따라 이 기공이 glass층으로 모이게 되어 de-lamination 현상이 발생하는 것으로 사료된다. 이를 해결하기 위하여 de-lamination층에 $Al_2O_3$의 tamping을 시도하여 glass층의 기공이 빠져 나갈 수 있는 channel 을 형성하고, 남아있는 기공을 $Al_2O_3$로 채우는 효과를 얻을 수 있었다. 이에 따라 기판의 밀도와 Quality factor 값이 향상되었으며 미세구조가 치밀한 무수축 기판을 제작할 수 있었다.

  • PDF

Glass Wool Filtration 후 돼지정액의 평가 (Evaluation of Extended Boar Semen after Glass Wool Filtration)

  • 강태영
    • 한국임상수의학회지
    • /
    • 제32권1호
    • /
    • pp.45-48
    • /
    • 2015
  • 돼지의 희석정액을 glass wool filtration 한 후 양질의 정자를 선별하고자 실시하였다. 돼지의 정액을 채취한 후 glass wool 높이와 시간에 따른 정자의 농도, 기형율, 생존율, 그리고 운동성을 조사하였다. Glass wool 여과 후 정자의 농도는 줄었으나, 정상 정자비율과 생존율은 상승하였고, 운동성의 변화는 나타나지 않았다. 이상의 결과들을 통해 돼지 정자의 glass wool 여과는 상대적으로 낮은 기형율과 높은 생존율을 가진 정자를 얻을 수 있는 방법임을 알 수 있었다.

유리병 경량화 지수를 이용한 유리병 포장용기 분석 (Analysis of Glass Bottle using Glass Bottle Lightness Index)

  • 김선종;장시훈;김기태;이유석;박수일
    • 한국포장학회지
    • /
    • 제19권2호
    • /
    • pp.109-115
    • /
    • 2013
  • 국내 유리병 포장의 개선 방향을 제시하기 위하여 유리병 경량화 지수를 이용하여 유리병 재질 사용 원천 감량을 위한 적정 기준을 설정하였다. 제품의 구분은 사용목적과 사용시간에 따라 일회용병과 다회에 걸쳐 장기간 두고 쓰는 반복사용병(returnable bottle) 및 장기보관 사용 일회용 유리병으로 구분하여 설정하였다. 재사용병의 대부분은 권고기준을 충족하고 있는 것으로 나타났으나 해외 제품의 경우 같은 품목임에도 지수가 최적기준에 준하는 수치를 보여 현저하게 낮은 지수를 보였다. 일회용 유리병 중 소용량 드링크류 유리병은 권고기준을 충족하지 못하여 감량할 필요성이 있는 품목군으로 판단된다. 반면 일회용 유리병 중 180 ml 주스류에 해당되는 품목은 평균적으로 권고기준에 가까운 지수를 보였다. 분석 결과, 해외 제품에 비해 국내 제품의 유리병 경량화 지수가 커 상대적으로 무거운 유리병을 사용하고 있는 것으로 나타나 경량화를 위한 노력이 필요하다고 판단된다. 일본의 경우 일본 유리병 재활용 촉진 협의회를 중심으로 유리병 경량화 지수를 이용하여 유리병의 친환경성을 평가하고 있다. 국내에서 업계의 자발적인 감량화 노력을 유도하는 협의회 구성이 필요하며 경량병 사용시 불이익 발생하지 않는 기술력을 확보해야 한다.

  • PDF