• 제목/요약/키워드: S-Duct

검색결과 598건 처리시간 0.041초

덕트형 소음기 설계 프로그램 개발 (Development of Design Program for Duct Silencer)

  • 김인수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.379-383
    • /
    • 2000
  • This paper describes the design program of duct silencer. Duct silencer is used ventilating system. Variables in the program for predicting transmission loss are width of splitter, airway width, perforate plate, absorption material and frequency. Generally used expression for predicting transmission loss has something that don't think about frequency characteristic. Therefore we propose the new expression that considered frequency characteristic. In the 1/1 octave band center frequency, the expected weighting number(K) is fitted with absorption ratio and airway width. The fitted 2nd degree polynomial expression is based on the test data performed in YOUIL Industrial Corperation. This program's accuracy is about 90 percent.

  • PDF

Effect of Well Curvature on Curved Duct Flows

  • 홍승규;허기훈;이광섭
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1997년도 추계 학술대회논문집
    • /
    • pp.131-135
    • /
    • 1997
  • Effect of wall curvature on flow characteristics is studied for mildly and strongly curved duct flows. The ducts are S-shaped, and the flow is partially blocked at the rear of the downstream. The presence of blockage in combination with curvature generates secondary flows on the concave surface; the magnitude of the secondary flow being dependent on the degree of wall curvature. Objectives are to compare the flow structures for mild and strong cases and to illuminate the changes in flow structure as the flow turns. Sensitivity on numerical solutions due to different inflow boundary conditions is also examined.

  • PDF

사각덕트 내 이단 오리피스를 지나는 유동의 압력강하에 대한 수치해석 (A Numerical analysis on the pressure drop of the flow field past a two-staged orifice in a rectangular duct)

  • 송우열;김유곤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2747-2752
    • /
    • 2007
  • A numerical study has been performed on the flow past a two-staged orifice in a rectangular duct. The flow field including the recirculation region behind the orifice was investigated and the pressure drop was calculated. Water was used as a working fluid and the flow was treated as the turbulent flow, of which the Raynolds number was 6000. The main parameters for the pressure drop and the recirculation region were the orifice's inclined angle against the duct, the interval between two orifices, the shape of the orifice's hole having the same area, and the change of the hole position at the same interval. The variation of the flow field was investigated with each parameter. Consequently, it was found that the most dominant parameter influencing the drop of the pressure was the change of the hole position at the same interval between orifices. Especially when the interval between orifices was narrow and the relative position the holes was changed, its effect to the flow field was shown most drastically as a result of this study. The SIMPLER algorithm with FLUENT code was employed to analyze the flow field.

  • PDF

정상중력 및 무중력에서의 저변형율 대향류화염의 전산 (Computation of a Low Strain Rate Counterflow Flame in Normal and Zero Gravity)

  • Woe-Chul Park
    • 한국안전학회지
    • /
    • 제17권3호
    • /
    • pp.107-111
    • /
    • 2002
  • 닥트의 두께와 속도 경계조건이 정상중력 및 무중력 상태에서 화염구조에 미치는 영향을 조사하기 위해 81%의 질소와 19%의 메탄이 혼합된 가연성가스와 공기의 저변형율 (20 s-1) 대향류 화염을 수치법으로 모사하였다. 정상중력에서는 닥트의 두께와 속도 경계조건에 따라 화염의 위치가 이동함으로써 그 영향이 컸으나, 무중력에서는 그 영향을 무시할 수 있을 정도로 작은 것으로 나타났다. 화염구조의 차이는 부력으로 인한 것이고, 따라서 정상중력에서의 측정에서는 닥트 두께와 속도 경계조건의 영향을 고려해야 함을 알 수 있었다.

악하선에 발생한 거대 타석증의 치험례 (A GIANT SIALOLITH IN A WHARTON'S DUCT: A CASE REPORT)

  • 김민철;민성윤;김지용;안제영;김형곤;박광호
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권1호
    • /
    • pp.93-96
    • /
    • 2005
  • Sialolithiasis is the most common disease caused by calculi in a salivary gland and its duct. The pain and swelling of salivary gland is a chief complaint of patients presenting. Most salivary gland calculi occur in the submandibular gland, but can also occur in the parotid gland and the sublingual gland. One giant sialolith is rarely reported, while the several cases of one or multiple sialolith in the submandibular gland have reported in the literatures. In this case, we have removed the sialolith in which perforated mouth floor along Wharton's duct and report it.

PIV 기법을 이용한 모형철도터널 직관덕트에서 유동 분포 계측 및 수치해석 결과와의 비교분석 (MEASUREMENT OF FLOW DISTRIBUTION IN A STRAIGHT DUCT OF RAILWAY TUNNEL MOCK-UP USING PIV AND COMPARISON WITH NUMERICAL SIMULATION)

  • 장용준;정우성;박일순
    • 한국전산유체공학회지
    • /
    • 제15권3호
    • /
    • pp.39-45
    • /
    • 2010
  • The turbulent flows in a tunnel mock-up($10L{\times}0.5W{\times}0.25H$ m3 : scale reduction 1/20) with rectangular cross section were investigated. The instantaneous velocity fields of Re = 49,029, 89,571 were measured by the 2-D PIV system which is consisted of double pulsed Nd:Yag laser and the tracer particles in the straight-duct mock-up where the flows were fully developed. The mean velocity profiles were taken from the ensemble averages of 1,000 instantaneous velocity fields. Simultaneously, numerical simulations(RANS) were performed to compare with experimental data using STREAM code. Non-linear eddy viscosity model (NLEVM : Abe-Jang-Leschziner Eddy Viscosity Model) was employed to resolve the turbulent flows in the duct. The calculated mean velocity profiles were well compared with PIV results. In the log-law profiles, the experimental data were in good agreement with numerical simulations all the way to the wake region except the viscous sub-layer (near wall region).

Modified Puestow Procedure for Chronic Pancreatitis in a Child Due to Annular Pancreas and Duodenal Duplication: A Case Report

  • Alatas, Fatima Safira;Masumoto, Kouji;Matsuura, Toshiharu;Pudjiadi, Antonius Hocky;Taguchi, Tomoaki
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제23권3호
    • /
    • pp.304-309
    • /
    • 2020
  • An 18-year-old woman with annular pancreas and duodenal duplication presented with recurrent acute pancreatitis and underwent a resection of duodenal duplication. However, the patient experienced recurrent abdominal pain after resection. Abdominal computed tomography and magnetic resonance imaging showed a dilatation of the peripheral pancreatic duct and stenosis and malformation of both the Wirsung's and Santorini's duct due to multiple stones. The modified puestow procedure was performed. The main pancreatic ducts in the body and tail were opened, and the intrapancreatic common bile duct was preserved. A Roux-en-Y pancreatico-jejunostomy was performed for reconstructing the pancreaticobiliary system after removing the ductal protein plug. The patient experienced no abdominal pain, no significant elevation of the serum amylase and lipase levels, and no stone formation during the 2 years of follow-up. This procedure is considered to be beneficial for pediatric patients with chronic pancreatitis due to annular pancreas and duodenal duplication.

기존 사무소 건물 및 설비전문가 조사를 통한 설비시스템의 변화와 전망에 대한 연구 (A Study on the Transition & Expectation through Survey for Existing Building and Engineer's Opinion)

  • 이관호;김남규;박진철;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제25권2호
    • /
    • pp.63-69
    • /
    • 2005
  • This study is the survey of a transition procedure of building services systems(heat source, HVAC, water supply) through the survey of existing office buildings, building design documents. The preference & major consideration of system selection is the engineer's opinions. The results of this survey can be used in selection of building services system design. In this survey, "Hot & cold water generator system" and "single duct CAV+FCU system", "Elevated water tank system" are selected. The most important consideration in system selection is the energy saving in heat source system, and comfort in HVAC system, and water pressure in water supply system. They prefer "steam boiler+absorption chiller system" for heat source system, "steam boiler+ice thermal storage system", "hot & cold water generator system", "district heating+absorption chiller system" : "single duct CAV+FCU system" and "single duct VAV+convector system" for HVAC system: and "booster pump system" for water supply system.

DEVELOPMENT OF NIGHT COOLING SYSTEM FOR GREENHOUSE USING COOL AIR AND WATER FROM AN ABANDONED COAL MINE

  • Whoa S. Kang;Wie S. Kang;Lee, Gwi H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.1136-1145
    • /
    • 1996
  • This study was to develop the most effective cooling system which is needed to cool greenhouse during summer night to get early blooming of strawberries. Various cooling systems were designed and constructed to utilize the cool air and water from tan abandoned coal mine. Cooling systems built for this study were an evaporative cooling system with pad, cooling system using a small or large radiator , and duct cooling system using cool are drawn from coal mine. These systems were individual tested to investigate their effects on cooling greenhouse during summer night. Also, a combined cooling system was tested with operating an evaporative cooling system, small radiator, and duct cooling system simultaneously. The results in this study showed that individual cooling systems such as evaporative cooling system, small radiator, and cooling duct had about the same effect on cooling greenhouse. The combined system had little better cooling effect than that of individual cooling syst m except the large radiator . The most effective system for cooling of greenhouse was obtained with using a large a large radiator as the heat exchanger. With operating a large radiator, temperature inside the greenhouse was dropped to about 15-16$^{\circ}C$ while outside temperature was 23-24$^{\circ}C$ during summer night.

  • PDF