• Title/Summary/Keyword: S-100 Standard

Search Result 1,003, Processing Time 0.028 seconds

Stabilization and solidification of tailings from a traditional gold mine using Portland cement

  • Rachman, Ranno Marlany;Bahri, Ayi Syaeful;Trihadiningrum, Yulinah
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.189-194
    • /
    • 2018
  • The traditional gold mining in Kulon Progo district, Special Region of Yogyakarta Province produced tailings containing mercury (Hg) from the gold amalgamation process. Mercury accumulated in tailings has 164.19 mg/kg - 383.21 mg/kg in total concentration. Stabilization/solidification (S/S) is one of the remediation technologies to reduce waste pollution. Portland cement is one of the additive materials in S/S that effective encapsulates heavy metal waste. The aim of this research is to know the optimum composition of tailings mixture with Portland cement in S/S process. This research used variation of tailings composition. Variation of Portland cement composition with tailing are 100:0, 90:10, 80:20, 70:30, 60:40, 50:50, 40:60, 30:70, 20:80 and 10:90. The result of this study found that the optimum composition of Portland cement: tailings was 10:90, with compression test of $257ton/m^2$ and TCLP test was 0.0069 mg/L. The compression test results were in accordance to US EPA Standard quality of $35ton/m^2$. TCLP test results meet the standard of Indonesian Government Regulation No. 101 Year 2014 of 0.05 mg/L.

News Focus - Today and Tomorrow of the Korea-made NPP, SMART (뉴스초점 - 한국 토종 원자로 'SMART"의 오늘과 내일)

  • Kim, Hak-Roh
    • Journal of the Korean Professional Engineers Association
    • /
    • v.44 no.6
    • /
    • pp.40-44
    • /
    • 2011
  • Nuclear energy in Korea began in 1958, when the Korea's atomic energy act was formulated and the relevant organizations were founded. Since then, notwithstanding the two catastrophe like TMI and Chernobyl accident, Korea made a wise decision to expand the peaceful uses of the nuclear energy as well as to localize the essential nuclear design technology of fuel and nuclear steam supply system. This decision resulted in the success of export of nuclear power plants as well as research reactor in 2010s. The Korea's nuclear policy, which well utilized 'international crisis in nuclear business' as 'opportunity of Korea to get. nuclear technology', is believed nice policy as a role model of nuclear new-comer countries. Based upon the success story of localization of nuclear technology, Korea had an eye for a niche market, which was a basis of development of SMART, Korea-made integral PWR. The operation of a SMART plant can sufficiently provide not only electricity but also fresh water for 100,000 residents. Last two years, Korea's nuclear industry team led by the Korea Atomic Energy Research Institute completed the standard design of SMART and applied to the Korea's regulatory body for standard design approval. Now the Korea's licensing authority is reviewing the design with the relevant documents, and the design team is doing its best to realize its hope to get the approval by the end of this year. From next year, the SMART business including construction and export will be explored by the KEPCO consortium.

  • PDF

MICRO HOLE FABRICATION BY MECHANICAL PUNCHING PROCESS

  • Joo B. Y.;Rhim S. H.;Oh S. I.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10b
    • /
    • pp.179-188
    • /
    • 2003
  • The objective of our study is to investigate the micro fabric ability by conventional metal forming processes. In the present investigation, micro hole punching was studied. We tried to control punching process at the micro level and scaled down the standard blanking condition for $25{\mu}m$ hole fabrication. To accommodate this, tungsten carbide tooling sets and micro punching press were carefully designed and assembled meeting accuracy requirements for $25{\mu}m$ hole punching. With our developments, 100, 50, and $25{\mu}m$ holes were successfully made on metal foils such as brass and stainless steel of 100, 50, and $25{\mu}m$ in thickness, respectively, and hole sizes and shapes were measured and analyzed to investigate fabrication accuracy. Shear behavior during micro punching was also discussed. Our study showed that the conventional punching process could produce high quality holes down to $25{\mu}m$.

  • PDF

Application of a solid-phase fluorescence immunoassay to determine neomycin residues in muscle tissue of olive flounder (Paralichthys olivaceus), rockfish (Sebastes schlegeli), and red sea bream (Pagrus major)

  • Jung, Won Chul;Chung, Hee Sik;Shon, Ho Yeong;Lee, Hu-Jang
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.2
    • /
    • pp.175-179
    • /
    • 2008
  • Parallux, a solid-phase fluorescence immunoassay (SPFIA) developed for detection antibiotics residue in milk, was applied for analysis of antibiotics in muscle tissue of olive flounder (Paralichthys olivaceus), rockfish (Sebastes schlegeli), and red sea bream (Pagrus major). Fishes were dipped in neomycin 140 mg/ton water, the recommended therapeutic dose, for 24 h. Muscle samples were obtained on 1st, 2nd, 3rd, 4th and 5th day after drug treatment. The concentration of neomycin in muscle was determined using an internal standard (100 ppb as neomycin). The absorbance ratio of sample to internal standard (S/C) was employed as an index to determine the muscle residues in fishes. To investigate the recovery rate, the standard solutions were added to muscle samples to give final concentrations in muscle of 0.2 and 0.5 mg/ml. The recovery rates of all spiked samples were > 85% of the spiked value. Neomycin was detected in muscles of fishes treated after the 1st day of withdrawal period. On the 2nd day after drug treatment, all muscle samples showed negative reaction (S/C ration ${\leq}$ 1.0). The present study showed that the SPFIA can be applied for predicting residues of neomycin in muscle tissues of farmed fishes.

Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus (전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교)

  • Kim, Byeong Soo;Park, Ju Young;Park, Byoung Suk;Song, Yong Min;Park, Byung Soo;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 2014
  • Purpose : If electron, chosen for superficial oncotherapy, was applied with bolus, it could work as an important factor to a therapy result by showing a drastic change in surface dose. Hence the calculation value and the actual measurement value of surface dose of Treatment Planning System (TPS) according to four variables influencing surface dose when using bolus on an electron therapy were compared and analyzed in this paper. Materials and Methods : Four variables which frequently occur during the actual therapies (A: bolus thickness - 3, 5, 10 mm, B: field size - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: energy - 6, 9, 12 MeV, D: gantry angle - $0^{\circ}$, $15^{\circ}$) were set to compare the actual measurement value with TPS(Pinnacle 9.2, philips, USA). A computed tomography (lightspeed ultra 16, General Electric, USA) was performed using 16 cm-thick solid water phantom without bolus and total 54 beams where A, B, C, and D were combined after creating 3, 5 and 10 mm bolus on TPS were planned for a therapy. At this moment SSD 100 cm, 300 MU was investigated and measured twice repeatedly by placing it on iso-center by using EBT3 film(International Specialty Products, NJ, USA) to compare and analyze the actual measurement value and TPS. Measured film was analyzed with each average value and standard deviation value using digital flat bed scanner (Expression 10000XL, EPSON, USA) and dose density analyzing system (Complete Version 6.1, RIT, USA). Results : For the values according to the thickness of bolus, the actual measured values for 3, 5 and 10 mm were 101.41%, 99.58% and 101.28% higher respectively than the calculation values of TPS and the standard deviations were 0.0219, 0.0115 and 0.0190 respectively. The actual values according to the field size were $6{\time}6$, $10{\time}10$ and $15{\time}15cm2$ which were 99.63%, 101.40% and 101.24% higher respectively than the calculation values and the standard deviations were 0.0138, 0.0176 and 0.0220. The values according to energy were 6, 9, and 12 MeV which were 99.72%, 100.60% and 101.96% higher respectively and the standard deviations were 0.0200, 0.0160 and 0.0164. The actual measurement value according to beam angle were measured 100.45% and 101.07% higher at $0^{\circ}$ and $15^{\circ}$ respectively and standard deviations were 0.0199 and 0.0190 so they were measured 0.62% higher at $15^{\circ}$ than $0^{\circ}$. Conclusion : As a result of analyzing the calculation value of TPS and measurement value according to the used variables in this paper, the values calculated with TPS on 5 mm bolus, $6{\time}6cm2$ field size and low-energy electron at $0^{\circ}$ gantry angle were closer to the measured values, however, it showed a modest difference within the error bound of maximum 2%. If it was beyond the bounds of variables selected in this paper using electron and bolus simultaneously, the actual measurement value could differ from TPS according to each variable, therefore QA for the accurate surface dose would have to be performed.

A 10b 100MS/s 27.2mW $0.8mm^2$ 0.18um CMOS Pipeline ADC with Various Circuit Sharing Schemes (다양한 회로 공유기법을 사용하는 10비트 100MS/s 27.2mW $0.8mm^2$ 0.18um CMOS Pipeline ADC)

  • Yoon, Kun-Yong;Lee, Se-Won;Choi, Min-Ho;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.4
    • /
    • pp.53-63
    • /
    • 2009
  • This work proposes a 10b 100MS/s 27.2mW $0.8mm^2$ 0.18um CMOS ADC for WLAN such as an IEEE 802.11n standard. The proposed ADC employs a three-stage pipeline architecture and minimizes power consumption and chip area by sharing as many circuits as possible. Two multiplying DACs share a single amplifier without MOS switches connected in series while the shared amplifier does not show a conventional memory effect. All three flash ADCs use only one resistor ladder while the second and third flash ADCs share all pre-amps to further reduce power consumption and chip area. The interpolation circuit employed in the flash ADCs halves the required number of pre-amps and an input-output isolated dynamic latch reduces the increased kickback noise caused by the pre-amp sharing. The prototype ADC implemented in a 0.18um n-well 1P6M CMOS process shows the DNL and INL within 0.83LSB and 1.52LSB at 10b, respectively. The ADC measures an SNDR of 52.1dB and an SFDR of 67.6dB at a sampling rate of 100MS/s. The ADC with an active die area of $0.8mm^2$ consumes 27.2mW at 1.8V and 100MS/s.

High Strain Rate Tensile Test of Composite Material for Automotive Front End Module Carrier (자동차 프론트엔드모률 캐리어용 경량 복합소재의 고속인장 시험)

  • Kang, Woo-Jong;Kim, Sung-Tae
    • Composites Research
    • /
    • v.24 no.3
    • /
    • pp.12-16
    • /
    • 2011
  • High strain rate tensile tests were performed to measure the strain rate sensitivity of fiber reinforced composite material. The composite material was developed for the light weight design of an automotive FEM(front end module) carrier. Standard specimens for quasi-static tests of fiber reinforced composites can be found in ASTM D3039. However, in case of high strain rate tests, it was hard to find standard specimen shapes. In this study, three kinds of tensile specimens designed based on ASTM D638 were investigated to determined the adequate gauge width of tensile specimen for fiber reinforced composite. A drop tower type of high speed tensile apparatus was developed for strain rates of about 15/s and 100/s. Gauge width of 6mm, 8mm and 10mm were investigated. Test results showed the specimen of 8mm width was adequate for the high strain rate tensile tests of fiber reinforced composite. It was found the strength of the composite material increased as the strain rate increased.

Evaluation of Flow Characteristics in Water Supply Pipes Shielding Electromagnetic Pulse of 100 dB with Concentric and Eccentric Reducers (Concentric Reducer와 Eccentric Reducer를 사용한 EMP 차폐 100dB급 급수관의 유동특성 평가)

  • Pang, Seung-Ki;Ahn, Hye-Rin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • In this paper, the flow characteristics of water in the water supply pipes of a WBC array were evaluated. We simulated the flow velocities and pressures for a standard pipe, an expansion pipe with a concentric reducer, and an expansion pipe with an eccentric reducer using computational fluid dynamics. In the case of the standard pipe, when the inlet flow velocities were 0.5 m/s and 2.0 m/s, the maximum flow velocities at the center of the WBC array were 0.54 m/s and 2.74 m/s, respectively, which were the greatest values among those of all the pipe models considered. In the case of the expansion pipe, the maximum flow velocities at the center of the WBC array were almost the same under the same conditions regardless of the type of reducer. The pressure losses in the pipe due to the concentric and eccentric reducers were found to be (165.09 ${\times}$ inlet $velocity^{1.6677}$) and (210.98 ${\times}$ inlet $velocity^{1.6478}$), respectively. The coefficient of determination at this time was greater than 0.99 and was the same for both the models. As a simulation result, it was found that in order to reduce the pressure loss when pipe with WBC array is connected with a conventional pipe, diameter of the pipe with WBC array at that section should be enlarged by one step, and then connected to the conventional pipe with a concentric reducer.

Effect of Synthetic Surfactants on the Activity of Mutagens (계면활성제가 돌연변이원성 물질의 활성에 미치는 영향)

  • Choi, Yoon-Ho;Chung, Yong
    • Environmental Analysis Health and Toxicology
    • /
    • v.7 no.3_4
    • /
    • pp.69-79
    • /
    • 1992
  • Recently, concerns of water pollution and health risks caused by synthetic detergents have emerged, as the use of various detergents has increased It has been suggested that some surfactants are cocarcinogens. The surfactants tested were linear alkylbenzene sulfonate, sodium lauryl sulfate, polyoxyethylene sorbitan monooleat (tween 80), and the mutagens were 1-nitropyrene, N -methyl- N'-nitro-N -nitrosoguanidine, benzo (a) pyrene, and aflatoxin B$_1$. This study was undertaken to investigate the effects of surfactants on the activity of mytagens using the Ames mutagenic assay with Salmonella typhimurium TA98, TA100. The results were summarized as follows: 1. The surfactants have no mutagenic activity of themselves. 2. Higher doses of surfactants than 100 $\mu\textrm{g}$/plate reduced the number of revertants. It is assumed that the reduction would inhibited cell growth. 3. When the comutagenic ratio is defined as the ratio between mutagenic activity itself and the activity with mutagen and surfactant (drinking water quality standard), LAS showed the comutagenic ratio 0.86-1.17 and SLS 0.74-1.10 as well. According to the comparisons, it could not be recognised for the comutagenicity of drinking water quality standard of surfactant. 4. As increasing the amount of mutagens, the designated amount of surfactant did not affected the mutagen's activity statistically. From the above result, syunthetic surfactants do not present mutagenicity and comutagenicity in the microbial assay.

  • PDF

Quality assessment and acceptability of whiteleg shrimp (Litopenaeus vannamei) using biochemical parameters

  • Kim, So-Hyun;Jung, Eun-Ju;Hong, Dong-Lee;Lee, Seung-Eun;Lee, Yang-Bong;Cho, Sueng-mok;Kim, Seon-Bong
    • Fisheries and Aquatic Sciences
    • /
    • v.23 no.9
    • /
    • pp.21.1-21.10
    • /
    • 2020
  • Background: This study aimed to provide a basic standard for assessing freshness and acceptability of whiteleg shrimp (Litopenaeus vannamei). Methods: It was divided into whole body and meat and stored at 25 ℃ to evaluate both quality and freshness changes that occur over time. The shelf life of shrimp was estimated as 17 and 20 h for whole body and meat, respectively. Results: In chemical analysis, K-value increased from 9.96 to 12.32% to a maximum of 75.14%, and TVB-N increased from 1.86 mg/100 g to 34.71 mg/100 g. For volatile sulfur compounds, methyl mercaptan and dimethyl disulfide increased from 0.00 mg/100 g to 1.10 mg/100 g and 1.26 mg/100 g, respectively, rapidly increasing with decreasing freshness. Conclusion: Changes in all biochemical indicators significantly correlated with the sensory evaluation results. This study contributes to the knowledge about whiteleg shrimp spoilage and freshness, providing a basis for developing methods to improve shrimp quality control and management.