• 제목/요약/키워드: S&P Noise

검색결과 398건 처리시간 0.035초

주간 및 야간 시간대에 따른 $L_{dn}$의 상관관계 - 도로교통소음을 중심으로 - (The Correlation of $L_{dn}$ in accordance with the daytime and the nighttime - Focusing on road traffic noise -)

  • 김득성;장서일;이연수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.34-40
    • /
    • 2006
  • The daytime(7 a.m to 10 p.m.) and the nighttime(10 p.m. to 7 a.m.) used to calculate existing $L_{dn}$ is different from the domestic daytime(6 a.m to 10 p.m.) and nighttime(10 p.m. to 6 a.m.) periods. The difference of a time periods makes too difficult for converting measured $L_{eq}$ during daytime($L_d$) and nighttime($L_n$) periods to $L_{dn}$. Thus, it is difficult to directly compare with $L_{dn}$ standard of a foreign country. The pupose of paper is to propose a proper experimental equations that make up for the problems. The data of this paper used road traffic noise data of Auto-Network System(ANS) that generates $L_{eq}$ TNI, $L_{NP}$ for 1 hour. A method of this paper is as follows.(1) The data of ANS converted 24 hour $L_{eq}$ which measured every 1 hour to existing $L_{dn}$ and to $L_{dn}$ of an experimental equations.(2) The existing Lan is compared to results of $L_{dn}$ from experimental equations. The paper proposes a three experimental equations. This paper select an approximate equation that was most similar, to existing $L_{dn}$ out of these equations. When $L_{eq}$ data of different daytime and nighttime periods are converted to $L_{dn}$, an experimental equation of this paper can be used and applied to $L_{dn}$'s calculation.

  • PDF

CMOS 표준셀의 자동설계 (An Automated Design of CMOS Standard Cells)

  • 김한흥;경종민
    • 대한전자공학회논문지
    • /
    • 제23권6호
    • /
    • pp.988-994
    • /
    • 1986
  • We present an automated CMOS standard cell design mehtodology which generates a mask description in the CIF (Caltech Intermediate Form)from a user-given logic description and design rule. The resultant layout reflects the user's choice among N-well, P-well and twin-well process and user's decision whether the guard band is to be included or not. Noise margin of each cell was improved by carefully adjusting the channel width of P-FET.

  • PDF

클러치 비틀림특성에 의한 자동차 수동변속기 치타음에 관한 연구 (A Study on Rattle Noise of Automotive Manual Transmission by way of Torsinal Characteristics of a Clutch Disc)

  • 홍동표;정태진;태신호
    • 한국자동차공학회논문집
    • /
    • 제3권3호
    • /
    • pp.79-89
    • /
    • 1995
  • Rattle noise occurs at manual transmission as idling and driving of a automotive. It can be solved by torsional characteristics of a clutch disc. A clutch disc consist of a region of pre-damper and main-damper. Rattle noise is affected by pre-damper and main-damper equipped for a torsional spring and friction washer. Pre-damper range covers noise radiating from manual transmission when engine is idling and main-damper range covers noise when engine is driving. The aim of this reserch is to clear transmission rattle noise by way of torsional characteristics of a clutch disc. The experiment is carried out as idling and driving of a automobile equipped for 1.5L MPI engine, dry single-disc type clutch and manual transmission. In this study, the results show for a vibration of manual transmission as idling and driving can be cleared by a clutch disc of Pre-damper type.

  • PDF

Wavelet Transform을 이용한 P파 검출에 관한 연구 (P-wave Detection Using Wavelet Transform)

  • 장원석;윤영로;윤형로
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.377-380
    • /
    • 1996
  • The purpose of this paper is to improve the P-wave detection capacity using wavelet transform. The first procedure is to remove baseline drift using the median filter. The second procedure is to cancel ECG's QRS-T complex with ECG's QRS-T complex templete to get P-wave candidate. Before we cancelled out the QRS-T complex, we estimated the best matching between templete and QRS-T complex to minimize the error. Then, Harr wavelet was used to eleminate the high frequency noise of ECG wave form cancelled the QRS-T complex. Finally, P-wave was discriminated and confirmed by threshold value. By using this method, We can got the around 95.1% P-wave detection.

  • PDF

장비 별 최적화된 영상 프로토콜을 이용한 환자에서의 3.0T 심장 자기공명영상의 임상경험: 1.5 T 자기공명영상과의 비교 (Clinical Experience with 3.0 T MR for Cardiac Imaging in Patients: Comparison to 1.5 T using Individually Optimized Imaging Protocols)

  • 고정민;정정임;이배영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권2호
    • /
    • pp.83-90
    • /
    • 2013
  • 목적: 본 연구의 목적은 환자에서 임상적으로 사용되는 영상 프로토콜을 이용하여 시행된 3.0 T 심장자기공명영상을 1.5 T 와 비교하여 그 유용성을 알아보고자 하는데 있다. 대상과 방법: 10개월간 30명의 환자에서 얻은 1.5 T 자기공명영상과 20명의 3.0 T 영상을 후향적으로 비교하였다. 각각의 영상에 대하여 신호 대 잡음비 (signal-to-noise ratio: SNR), 대조도 대 잡음비 (contrast-to-noise ratio: CNR), 영상 화질 (artifact의 정도에 따라서 5단계로 분류)을 평가하고 비교하였다. 결과: T1심장 형태 영상 및 심근 생존능 평가 영상에서는 3.0 T 자기공명영상에서 영상화질 (T1: $3.8{\pm}0.9$ vs. $3.9{\pm}0.7$, p=0.438; T2-SPAIR: $3.8{\pm}0.9$ vs. $3.9{\pm}0.5$, p=0.744; 지연기 조영 증강 영상: $4.5{\pm}0.8$ vs. $4.7{\pm}0.6$, p=0.254)의 유의한 저하 없이 SNR과 CNR의 향상을 보였다 (T1: SNR 29%, p < 0.001, CNR 37%, p < 0.001; T2-SPAIR: SNR 13%, p=0.068, CNR 18%, p=0.059; 지연기 조영 증강 영상: SNR 45%, p=0.017, CNR 37%, p=0.135). 심장Cine 영상에서 3.0 T 심장영상이 1.5 T 영상과 비교하여 영상화질($3.6{\pm}0.7$ vs. $4.2{\pm}0.6$, p < 0.001)이 다소 떨어졌으나 SNR과 CNR의 유의한 상승을 보였다 (SNR 143% 상승, CNR 108% 상승, p < 0.001). 심근관류영상에서는 SNR (11% 감소, p=0.172)과 CNR (7% 감소, p=0.638) 이 통계적으로 유의하지 않은 정도로 감소되었으나 영상화질($4.6{\pm}0.5$ vs. $4.0{\pm}0.8$, p=0.006)은 유의한 향상을 보였다. 결론: 실제 임상영역에서 사용되는 영상 프로토콜로 시행된 3.0 T 심장자기공명영상은 1.5T 영상과 비교하여 충분한 영상의 질을 제공하였다.

다차원적 행동 모델에 근거한 치매 노인의 정신행동 증상 예측요인 (Predictors of Behavioral and Psychological Symptoms of Dementia: Based on the Model of Multi-Dimensional Behavior)

  • 양정은;홍(손)귀령
    • 대한간호학회지
    • /
    • 제48권2호
    • /
    • pp.143-153
    • /
    • 2018
  • Purpose: The purpose of this study was to identify factors predicting behavioral and psychological symptoms of dementia (BPSD) in persons with dementia. Factors including the patient, caregiver, and environment based on the multi-dimensional behavioral model were tested. Methods: The subjects of the study were 139 pairs of persons with dementia and their caregivers selected from four geriatric long-term care facilities located in S city, G province, Korea. Data analysis included descriptive statistics, inverse normal transformations, Pearson correlation coefficients, Spearman's correlation coefficients and hierarchical multiple regression with the SPSS Statistics 22.0 for Windows program. Results: Mean score for BPSD was 40.16. Depression (${\beta}=.42$, p<.001), exposure to noise in the evening noise (${\beta}=-.20$, p=.014), and gender (${\beta}=.17$, p=.042) were factors predicting BPSD in long-term care facilities, which explained 25.2% of the variance in the model. Conclusion: To decrease BPSD in persons with dementia, integrated nursing interventions should consider factors of the patient, caregiver, and environment.

개별 블레이드 조종을 통한 로터 허브 진동 저감 해석 (Rotor Hub Vibration Reduction Analysis Applying Individual Blade Control)

  • 김태주;위성용;김민우;이동건
    • 한국항공우주학회지
    • /
    • 제49권8호
    • /
    • pp.649-660
    • /
    • 2021
  • S -76 모델을 기준으로 해석을 통해 개별 블레이드에 대한 고조화 가진에 따른 로터 허브 진동 수준을 분석하였다. 개별 블레이드에 대한 고조화 가진 방법은 회전부에 있는 피치링크 자체에서 추가적인 가진력을 발생하는 방법(Actuating by Individual Pitch-link)과 블레이드 능동 뒷전 플랩조절을 통해 가진력을 발생하는 방법(Active Trailing Edge Flap)으로 구분하였다. 100kts의 전진비행 조건에서 개별 블레이드에 대한 2P/3P/4P/5P 조화 가진을 15도의 위상각을 변경시켜가며 허브 하중 해석을 수행하였다. 그 결과를 통해 가진 조건에 따른 로터 시스템의 민감도를 확인하였으며 이 정보를 기반으로 로터 시스템의 특성을 나타내는 전달 행렬(T-matrix)을 구성하였다. 그리고 전달 행렬을 통해 비행조건에 대해 허브 진동 수준을 최소화하는 최적의 고조화 가진 조건을 도출하였다. 그리고 최소 허브 진동 조건에서 로터 시스템의 성능 및 피치링크 하중에 대한 영향성과 더불어 소음해석을 통한 소음 영향성도 확인하였다.

폐기종에 대한 저선량 CT의 유용성 평가: 고해상도 CT와 비교 (Usefulness Evaluation of Low-dose CT for Emphysema : Compared with High-resolution CT)

  • 이원정
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.329-336
    • /
    • 2016
  • 본 연구에서는 폐기종에 대해 고해상도 CT와 비교한 저선량 CT 의 유용성에 대해 평가하였다. 고해상도 CT와 저선량 CT 노출조건에서 선량과 영상 잡음을 3회 반복 측정하였다. 비슷한 노출조건에서 획득한 146명의 고해상도 CT와 저선량 CT 영상에 대해 2명의 흉부영상의학과전문의 합의 판독결과에서 폐기종 소견 만을 본 연구에 사용하였다. SPSS ver. 19.0 프로그램 사용하여 고해상도 CT와 저선량 CT 간에 폐기종에 대한 진단 차이는 McNemar's tests, 일치도는 unweighted kappa tests, 선량과 잡음 차이는 Mann-Whitney U-test 로 분석하였다. 선량은 고해상도 CT가 저선량 CT 보다 높았지만(1.95 mGy vs. 0.35 mGy, p=0.008), 잡음은 낮았다(40.1 HU vs. 99.6 HU, p=0.021). 폐기종 진단에 대해서는 두 영상 간에 높은 일치도를 보였다(k-value=0.88). 폐기종 점수는 두 영상 간에 통계적인 유의한 차이를 보이지 않았고, 높은 상관성을 보였다(r=0.599, p < 0.001). 선량과 잡음을 고려했을 때, 저선량 CT는 폐기종 진단에 표준 진단 방법 인 고해상도 CT를 대신하여 사용할 수 있을 것으로 사료된다.

표적 탐지/추적 성능 향상을 위한 불균일 미세 잡음 영상 화질개선 연구 (A study on enhancement of heterogeneous noisy image quality for the performance improvement of target detection and tracking)

  • 김용;유필훈;김다솔
    • 한국멀티미디어학회논문지
    • /
    • 제17권8호
    • /
    • pp.923-936
    • /
    • 2014
  • Images can be contaminated with different types of noise, for different reasons. The neighborhood averaging and smoothing by image averaging are the classical image processing techniques for noise removal. The classical spatial filtering refers to the aggregate of pixels composing an image and operating directly on these pixels. To reduce or remove effectively noise in image sequences, it usually needs to use noise reduction filter based on space or time domain such as method of spatial or temporal filter. However, the method of spatial filter can generally cause that signals of objects as the target are also blurred. In this paper, we propose temporal filter using the piece-wise quadratic function model and enhancement algorithm of image quality for the performance improvement of target detection and tracking by heterogeneous noise reduction. Image tracking simulation that utilizes real IIR(Imaging Infra-Red) images is employed to evaluate the performance of the proposed image processing algorithm.

Optimized Phase Noise of LC VCO Using an Asymmetrical Inductance Tank

  • Yoon Jae-Ho;Shrestha Bhanu;Koh Ah-Rah;Kennedy Gary P.;Kim Nam-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제6권1호
    • /
    • pp.30-35
    • /
    • 2006
  • This paper describes fully integrated low phase noise MMIC voltage controlled oscillators(VCOs). The Asymmetrical Inductance Tank VCO(AIT-VCO), which optimize the shortcoming of the previous tank's inductance optimization approach, has lower phase noise performance due to achieving higher equivalent parallel resistance and Q value of the tank. This VCO features an output power signal in the range of - 11.53 dBm and a tuning range of 261 MHz or 15.2 % of its operating frequency. This VCO exhibits a phase noise of - 117.3 dBc/Hz at a frequency offset of 100 kHz from carrier. A phase noise reduction of 15 dB was achieved relative to only one spiral inductor. The AIT-VCO achieved low very low figure of merit of -184.6 dBc/Hz. The die area, including buffers and bond pads, is $0.9{\times}0.9mm^2$.