• Title/Summary/Keyword: Ryu-Hee

Search Result 3,604, Processing Time 0.046 seconds

The Change of Physico-Chemical Properties of Paddy Soil in Reclaimed Tidal Land (간척지 논토양의 물리화학성 변동에 관한 연구)

  • Yang, Chang-Hyu;Yoo, Chul-Hyun;Jung, Ji-Ho;Kim, Byeong-Su;Park, Woo-Kyun;Ryu, Jin-Hee;Kim, Taek-kyum;Kim, Jae-Duk;Kim, Seong-Jo;Baek, Seung-Hwa
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.2
    • /
    • pp.94-102
    • /
    • 2008
  • The physico-chemical properties of ten reclaimed saline soils in five soil series of west-south Korea were analyzed according to the years past after reclamation. The soil samples were collected at the same sites two times in 2000 and 2004. The physico-chemical properties in 2000 had been changed in 2004 as follows. Soil salinity was the highest in Podu and desalinization period was the shortest in Munpo and Yeompo. Seasonal ground water level were above 100 cm in all regions that were 30 years old reclaimed tidal land, which was the same results of normal paddy field. In the case of soil physical changes, bulk density increased in fine textured soil (Poseung and Podu) but decreased in coarse textured soil (Gwanghwal, Munpo, and Yeompo). Porosity decreased in fine textured soil(Poseung and Podu) but increased in coarse textured soil. These reason were as follows. Fine textured soil were increased in solid phase but decreased in liquid and gaseous phase. Coarse textured soil, Gwanghwal and Munpo except for Yempo, were increased in gaseous phase but decreased in solid and liquid phase. Yempo that have low water table level were increased in liquid phase but decreased in solid and gaseous phase. Soil hardness increased in 4 soil series except for Munpo. In the case of chemical property changes, although there were more or less difference, it showed decreasing tendencies. Soil pH, the content of organic matter, available phosphate, and available silicate of five soil series were decreased during the four years. The content of exchangeable cation also decreased except for magnesium.

Effects of Atmospheric factors on Local Adaption Rearing Test Results of Superior Breeding Combination of Silkworms (기상요소가 누에 우량교배조 지역적응시험의 작황에 미치는 영향)

  • Sohn, Bong-Hee;Kang, Pil-Don;Ryu, Kang-Sun;Jung, I-Yeon;Kim, Yong-Soon;Kim, Kee-Young;Kim, Mi-Ja
    • Journal of Sericultural and Entomological Science
    • /
    • v.49 no.2
    • /
    • pp.51-55
    • /
    • 2007
  • Investigation of atmospheric data and rearing results was conducted to analyze the effects of atmospheric factors such as temperature and precipitation on silkworm in 8 rearing places in which local adaptation test was being conducted with different mulberry growth condition, soil and atmosphere during spring and autumn rearing season of 2006. The atmospheric characteristics of spring rearing time are as follows. The average temperatures of young silkworm, old silkworm, mounting were $17.7^{\circ}C$, $19.8^{\circ}C$, $21.5^{\circ}C$ respectively, and $1^{\circ}C$ higher than normal year. The precipitation of young silkworm, old silkworm, mounting were 15.1 mm, 6.9 mm, 7.0 mm, respectively, and 22.9 mm lower than normal year in old silkworm and mounting. The daylight hours in larval stage was 1.7 hour shorter than normal year, but no difference in mounting. Thus precipitation was lower and temperature was higher than normal year in 2006. The rearing results of 2006 were 1 kg lower than normal year in cocoon yields per 10,000 3 rd molted larvae, single cocoon weight and cocoon shell percentage were a little higher. The atmospheric characteristics of spring rearing season are as follows. The average temperatures of young silkworm, old silkworm, mounting were $25.1^{\circ}C$, $20.5^{\circ}C$ and $19.9^{\circ}C$ respectively, temperature in young silkworm was $1^{\circ}C$ higher than normal year, and temperature in old silkworm was $1.3^{\circ}C$ lower than normal year. The precipitation of young silkworm, old silkworm, mounting were 110.2 mm, 4.6 mm, 3.7 mm, respectively and there were little differences compared to normal year. The atmospheric condition of 2006 which was similar to normal year did not affect the autumn rearing results of 2006. Namely, the single cocoon weight and cocoon shell weight were not different from normal year, and the same was cocoon shell percentage.

Growth Temperature Effects of In0.4Al0.6As Buffer Layer on the Luminescence Properties of InGaAs/InAlAs Quantum Well Structures (InGaAs/InAlAs 양자우물구조의 발광특성에 대한 In0.4Al0.6As 버퍼층 성장온도의 영향)

  • Kim, Hee-Yeon;Ryu, Mee-Yi;Lim, J.Y.;Shin, S.H.;Kim, S.Y.;Song, J.D.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.449-455
    • /
    • 2011
  • The luminescence properties of $In_{0.5}Ga_{0.5}As/In_{0.5}Al_{0.5}As$ multiple quantum wells (MQWs) grown on $In_{0.4}Al_{0.6}As$ buffer layer have been investigated by using photoluminescence (PL) and time-resolved PL measurements. A 1-${\mu}m$-thick $In_{0.4}Al_{0.6}As$ buffer layers were deposited at various temperatures from $320^{\circ}C$ to $580^{\circ}C$ on a 500-nm-thick GaAs layer, and then 1-${\mu}m$-thick $In_{0.5}Al_{0.5}As$ layers were deposited at $480^{\circ}C$, followed by the deposition of the InGaAs/InAlAs MQWs. In order to study the effects of $In_{0.4}Al_{0.6}As$ layer on the optical properties of the MQWs, four different temperature sequences are used for the growth of $In_{0.4}Al_{0.6}As$ buffer layer. The MQWs consist of three $In_{0.5}Al_{0.5}As$ wells with different well thicknesses (2.5-nm, 4.0-nm, and 6.0-nm-thick) and 10-nm-thick $In_{0.5}Al_{0.5}As$ barriers. The PL peaks from 4-nm QW and 6-nm QW were observed. However, for the MQWs on the $In_{0.4}Al_{0.6}As$ layer grown by using the largest growth temperature variation (320-$580^{\circ}C$), the PL spectrum only showed a PL peak from 6-nm QW. The carrier decay times in the 4-nm QW and 6-nm QW were measured from the emission wavelength dependence of PL decay. These results indicated that the growth temperatures of $In_{0.4}Al_{0.6}As$ layer affect the optical properties of the MQWs.

Accuracy of the Registered Cause of Death in a County and its Related Factors (일개 군 사망신고자료에 기재된 사인의 정확성과 관련요인)

  • Shin, Hee-Young;Shin, Jun-Ho;Nam, Hae-Sung;Ryu, So-Yeon;Im, Jeong-Soo;Rhee, Jung-Ae;Chung, Eun-Kyung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.2
    • /
    • pp.153-159
    • /
    • 2002
  • Objectives : To evaluate the accuracy of the registered cause of death in a county and its related factors. Methods : The data used in this study was based on 504 cases, in a county of Chonnam province, registered between January and December 1998. Study subjects consisted of 388 of the 504 cases, and their causes of death were established by an interview survey of the next of kin or neighbor and medical record surveys. We compared the registered cause of death with the confirmed cause of death, determined by surveys and medical records, and evaluated the factors associated with the accuracy of the registered cause of death. Results : 62.6% of the deaths were concordant with 19 Chapters classification of cause of death. external causes of mortality, endocrine, nutritional and metabolic diseases, neoplasms and diseases of the circulatory system showed the good agreement between the registered cause of death and the confirmed cause of death. The factors relating to the accuracy of the registered cause of death were the doctors' diagnosis for the cause of death (adjusted Odds Ratio: 2.67, 95% Confidence Interval: 1.21-5.89) and the grade of the public officials in charge of the death registry (adjusted Odds Ratio: 0.30, 95% CI=0.12-0.78). Conclusions : The accuracy of the registered cause of death was not high. It could be improved by using the doctors' diagnosis for death and improving the job specification for public officials who deal with death registration.

$^{99m}Tc$-HMPAO-labelled Leucocyte Scintigraphy in the Diagnosis of Infection after Total Knee Replacement Arthroplasty (인공슬관절 전치환술 환자에서 $^{99m}Tc$-HMPAO-백혈구 스캔을 이용한 인공관절 감염의 진단)

  • Park, Dong-Rib;Kim, Jae-Seung;Ryu, Jin-Sook;Moon, Dae-Hyuk;Bin, Seong-Il;Cho, Woo-Shin;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.413-421
    • /
    • 1999
  • Purpose: This study was performed to evaluate the usefulness of $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy Materials and Methods: The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age. 65 years) who had total knee replacement arthroplasty. After injection of $^{99m}Tc$-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection. Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Results: Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positives, one false positive and three true negatives in Group B, and six true negatives and two false positives in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively Conclusion: $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity.

  • PDF

The Evaluation of Domestic Immunoradiometric Assay Kit for Alpha-fetoprotein (Alpha-fetoprotein 측정용 국산 방사면역측정법 시약의 평가)

  • Won, Kyoung-Sook;Ryu, Jin-Sook;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.353-359
    • /
    • 2000
  • Purpose: Although ${\alpha}$-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for ${\alpha}$-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for ${\alpha}$-fetoprotein (Riakey AFP IRMA $CT^R$, Sin-Jin Medics, Seoul, Korea). Materials and Methods: We evaluated intra- and inter-assay precision, recovery rate, parallelism, and sensitivity of serum ${\alpha}$-fetoprotein measurement using Riakey AFP IRMA $CT^R$ kit. The values of ${\alpha}$-fetoprotein measured by Riakey AFP IRMA $CT^R$ kit were compared with those measured by two foreign commercial kits (${\alpha}$-fetoproteina of Radim and ${\alpha}$-feto.riabead of Abbott). Results: Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within $100{\pm}10%$. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of ${\alpha}$-fetoprotein by Riakey AFP IRMA $CT^R$ and that by two foreign commercial kits(r=0.98). Conclusion: The first Korean domestic immunoradiometric kit for ${\alpha}$-fetoprotein, Riakey AFP IRMA $CT^R$, performed well for clinical use.

  • PDF

Improved Cerebral Blood Flow and Cerebrovascular Reserve after Carotid Endarterectomy in Patients with Carotid Stenosis and Contralateral Carotid Occlusion: Acetazolamide Stress Brain SPECT Study (반대측 내경동맥 폐쇄를 동반한 경동맥 협착에서 경동맥 내막절제술 후 뇌혈류 및 뇌혈관 예비능의 증가: 아세타졸아마이드 부하 뇌혈류 SPECT 연구)

  • Kim, Jae-Seung;Moon, Dae-Hyuk;Kim, Geun-Eun;Kim, Jong-S.;Kweon, Sun-Uck;Cho, Yong-Pil;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.352-361
    • /
    • 1999
  • Purpose: Carotid endarterectomy nay benefit patients with bilateral carotid stenosis by improving cerebro-vascular hemodynamics of ipsilateral as well as contralateral cerebral hemispheres. We investigated cerebro-vascular hemodynamics after carotid endarterectomy in patients with contralateral carotid occlusion by acetazolamide stress brain SPECT. Materials and Methods: Subjects were 14 symptomatic patients (all men, mean age 66 yrs) with carotid stenosis (>50%) with contralateral carotid occlusion. Acetazolamide stress Tc-99m ECD brain SPECTs were performed within 2 weeks before and after carotid endarterectomy using one day protocol. Cerebral blood flow (CBF) and cerebrovascular reserve (CVR) were assessed visually. In 12 patients, correlation between the patency of proximal anterior cerebral or anterior communicating arteries (A1/A-comm) and the improvement of CBF or CVR after endarterectomy was assessed. Results: Preoperative SPECT showed reduced CBF in 2 ipsilateral and 10 contralateral hemispheres. CVR was reduced in 4 ipsilateral and 9 contralateral hemispheres. Of 12 hemispheres with reduced CBF, 2 hemispheres (16.7%) showed improvement of CBF after endarterectomy. However, reduced CVR was improved in all 4 ipsilateral and 7 of 9 (78%) of contralateral hemispheres after endarterectomy. Three of4 with stenotic Al/A-comm and 4 of 8 with patent A1/A-comm had reduced contralateral CVR. Reduced contralateral CVR improved in all 3 patients with stenotic A1/A-comm and 3 of 4 with patent A1/A-comm. Conclusion: Acetazolamide stress brain SPECT demonstrated improvement of compromised cerebrovascular reserve in not only ipsilateral but also contralateral hemispheres of patients with contralateral carotid occlusion after carotid endarterectomy, and may, therefore, be useful for evaluating cerebral blood flow and cerebrovascular reserve after carotid endarterectomy.

  • PDF

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

A Report on the Shigella Cultures Isolated in Korea (1972) (1972년(年) 한국(韓國)에서 분리(分離)된 이질균(痢疾菌)에 관(關)한 보고(報告))

  • Ryu, Young-Hat;Kim, Soon-Hee
    • The Journal of the Korean Society for Microbiology
    • /
    • v.8 no.1
    • /
    • pp.7-11
    • /
    • 1973
  • The authors identified eighty-eight Shigella cultures among about four thousands specimens collected from all over the country in 1972. Of eighty-eight cultures, seventy-seven cultures belonged to Shigella flexneri and eleven cultures to Shigella sonnei. None of cultures belonging to either subgroup A or C was detected in 1972. Of seventy-seven cultures of Shigella flexneri one was $B_{1b}$, fifty-six were $B_{2a}$, nine were $B_{3a}$, six were $B_{4a}$, three were By and one was each of $B_{3b}$ and $B_{3c}$. Of eleven cultures of Shigella sonnei seven cultures appeared to be phase I and the others phase II. Although there was quite a difference found in the incidence of isolating Shigella organisms between different areas as shown in Table 1, it would not be possible to understand that there might not have been the cases or carriers of Shigella in the areas where the organisms were not isolated in 1972. Concerning the biochemical properties it was not possible to compare the results obtained from the decarboxylase and dihydrolase tests with them obtained in previous years except that of lysine decarboxylase tests since they were not reported individually by the different serotypes in the previous reports. These results obtained in 1972 would be the data for the future comparison. In regards to the antibiotics-sensitivity of Shigella cultures the most of them showed sensitive results to nitrofurantoin, ampicillin, cephalosporin, gentamycin and geopen, and the majority of them appeared to be resistant to cloxacillin, tetracycline and streptomycin by means of the In Vitro tests.

  • PDF

Effects of Salt and Soysauce Condiment on Lipid Oxidation in Broiled Mackerel (Scomber japonicus) (소금과 간장 양념이 고등어 구이의 지질산화 안정성에 미치는 영향)

  • Ryu, Seung-Hee;Lee, Young-Soon;Moon, Gap-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.1030-1035
    • /
    • 2002
  • Despite health benefits derived from fish oil, polyunsaturated fatty acids (PUFAs) contained in fish oil are susceptible to lipid oxidation. To determine the optimum condition for maintaining good quality cooked fish during storage, mackerels were broiled with salt or soysauce condiments, and the lipid oxidation during 12 days of storage at refrigerated condition was measured. Peroxide value of broiled mackerel group with salt significantly increased after immediate cooking and maintained higher value throughout the storage period compare to the soysauce-added group, but showed similar value to the control group. Conjugated diene content in the soysauce-group was lower than the control and salt-added groups. Malondialdehyde content of broiled mackerel increased twofold and showed similar values in soysauce-added and the control groups during storage, whereas increased in the salt-added group significantly. Fatty acid compositions of the three mackerel groups changed after cooking, whereas that of the control group was almost stable during storage. In comparison with raw mackerel, the ratio of PUFA and saturated fatty acids decreased significantly, and the content of n-3 family fatty acid decreased from 25.53 to 20.63% in salted broiled mackerel. Soysauce group showed no reduction of PUFA with increasing storage time and showed the highest ratio of n-3/n-6 among the three groups at 10 days storage. Results reveal soysauce condiment protects against lipid peroxidation of broiled mackerel. Maillard reaction products (MRPs) found in soysauce might be responsible for the inhibitory effect and is a good condiment for extending storage life of cooked fish containing high amount of PUFA.