Factors affecting the infiltration rate and removal of suspended solids in gravel-filled stormwater management structures

  • Guerra, Heidi B.;Yuan, Qingke;Kim, Youngchul
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Apparent changes in the natural hydrologic cycle causing more frequent floods in urban areas and surface water quality impairment have led stormwater management solutions towards the use of green and sustainable practices that aims to replicate pre-urbanization hydrology. Among the widely documented applications are infiltration techniques that temporarily store rainfall runoff while promoting evapotranspiration, groundwater recharge through infiltration, and diffuse pollutant reduction. In this study, a laboratory-scale infiltration device was built to be able to observe and determine the factors affecting flow variations and corresponding solids removal through a series of experiments employing semi-synthetic stormwater runoff. Results reveal that runoff and solids reduction is greatly influenced by the infiltration capability of the underlying soil which is also affected by rainfall intensity and the available depth for water storage. For gravel-filled structures, a depth of at least 1 m and subsoil infiltration rates of not more than 200 mm/h are suggested for optimum volume reduction and pollutant removal. Moreover, it was found that the length of the structure is more critical than the depth for applications in low infiltration soils. These findings provide a contribution to existing guidelines and current understanding in design and applicability of infiltration systems.

Optimal Location of Best Management Practices for Storm Water Runoff Reduction (우수유출저감 시설의 최적위치 결정)

  • Jang, Su Hyung;Lee, Jiho;Yoo, Chulsang;Han, Suhee;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.2
    • /
    • pp.180-184
    • /
    • 2008
  • A distributed hydrologic model of an urban drainage area on Bugok drainage area in Oncheon stream was developed and combined with a optimization method to determine the optimal location and number of best management practices (BMPs) for storm water runoff reduction. This model is based on the SCS-CN method and integrated with a distributed hydrologic network model of the drainage area using system of 4,211 hydrologic response units (HRUs). Optimal location is found by locating HRU combination that leads to a maximum reduction in peak flow at the drainage outlet in this model. The results of this study indicate the optimal locations and numbers of BMPs, however, for more exact application of this model, project cost and SCS-CN reduction rate of structural facilities such infiltration trench and pervious pavement will have to be considered.

Analysis of Drought Risk in the Upper River Basins based on Trend Analysis Results (갈수기 경향성 분석을 활용한 상류 유역의 가뭄위험 변동성 분석)

  • Jung, Il Won;Kim, Dong Yeong;Park, Jiyeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • This study analyzed the variability of drought risk based on trend analysis of dry-seasonal dam inflow located in upper river basins. To this, we used areal averaged precipitation and dam inflow of three upper river dams such as Soyang dam, Chungju dam, and Andong dam. We employed Mann-Kendall trend analysis and change point detection method to identify the significant trends and changing point in time series. Our results showed that significant decreasing trends (95% confidence interval) in dry-seasonal runoff rates (= dam inflow/precipitation) in three-dam basins. We investigated potential causes of decreasing runoff rates trends using changes in potential evapotranspiration (PET) and precipitation indices. However, there were no clear relation among changes in runoff rates, PET, and precipitation indices. Runoff rate reduction in the three dams may increase the risk of dam operational management and long-term water resource planning. Therefore, it will be necessary to perform a multilateral analysis to better understand decreasing runoff rates.

Development of the Sub-soil Storage System for Utilization Urban Instream Flow of Rainfall Runoff (우수유출수의 도시하천 유지유량 활용을 위한 지하저류시스템 개발)

  • Choi, Gye-Woon;Choi, Jong-Young;Kim, Suk-Dong
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.2
    • /
    • pp.163-172
    • /
    • 2004
  • In this paper, the sub-soil storage system for utilizing urban instream flow of rainfall runoff was developed and examined through experiments. The artificial rainfall facility and sub-soil storage were installed in the experimental area. The effect of the water qualify improvement and the storage effect were analyzed through the several experiments. Through the experiments of rainfall intensity variation, which are the rainfall intensity of 20mm/hr, 30mm/hr, 40mm/hr, 50mm/hr was indicated SS concentration can be reduction until 68%. Also, the ration of the storage volume is varied from 42.8%∼79.9% based on the rainfall intensity. The reduction rate of the BOD, CO $D_{Mn}$, SS, T-N, T-P was 30%, 42%, 68%, 39%, 26%. As the result, water quality of runoff and efficient of runoff reduction by the system are much improved. The rainfall runoff with the installation of sub-soil storage could be used for instream flow.

Analysis of Runoff Reduction with LID Adoption using the SWMM (SWMM을 이용한 춘천 거두 1지구의 LID 개념 적용으로 인한 유출 감소 특성 분석)

  • Park, Junho;Yoo, Yonggu;Park, Youngkon;Yoon, Heetaek;KIm, Jonggun;Park, Younshik;Jeon, Ji-Hong;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.806-816
    • /
    • 2008
  • In recent years, increases in impervious areas with rapid urbanization and land use changes are causing numerous hydrologic and environmental problems. In this study Low Impact Development (LID) was applied to investigate changes in runoff and peak runoff with LID plans. SWMM 5.0 was used to simulate LID Integrated Management Practices (IMPs) at study area. The SWMM estimated total runoff volume with conventional land use planning is (82.3%, 46.44 mm), (99%, 73.16 mm) greater than total runoff before urbanization, while total runoff with LID is (11.1%, 46.44 mm), (49%, 73.16 mm) greater than those before urbanization. With the LID adoption in land use planning, pervious area increases by 49.8% compared with that from the conventional urban land use planning, resulting in (32.7%, 46.44 mm), (23.6%, 73.16 mm) decrease in total runoff, and (32.6%, 46.44 mm), (18.5%, 73.16 mm) decreases in peak rate runoff. The results obtained from this study indicate that peak rate runoff, time to peak, and total runoff can be reduced with the LID in urban land use planning because the LID secures pervious areas with various LID IMPs. The SWMM simulated result using design storm data and the US EPA suggested CN values for various LID IMPs implies that how environment-friendly urban land use planning with the LID adoption is important for sustainable development at urbanizing watershed.

A Study on the Proper Size of Rainwater Stored Tank in Submerged Districts Using SWMM Program (SWMM을 활용한 침수예상지역 우수저류조의 적정크기결정에 관한 연구)

  • Jang, Seung-Jae
    • Journal of the Korean housing association
    • /
    • v.20 no.3
    • /
    • pp.69-76
    • /
    • 2009
  • The Storm Water Management Model(SWMM) by EPA is a dynamic rainwater-runoff simulation model used for single event or long-term simulation of runoff quantity and quality from primarily urban areas. The SWMM simulation program is operated by the site area, the weather date, conduit plan etc. on reference region. The purpose of this study was to analyze flood area, the duration of flooded and surcharged on the reference region. Without rainwater stored tank, the area of flooded and surcharged on reference area is similar to the area of reference region. But, With rainwater stored tank, the area of flooded and surcharged on reference area is much reduced compared to without rainwater stored tank. According to SWMM simulation results, the rainwater stored tank is located closer to site is more effective for reduction of duration of flooded and surcharged and flow rate.

Analysis of Stormwater Runoff Characteristics for Spatial Distribution of LID Element Techniques using SWMM (SWMM 모형을 이용한 LID 요소기술의 공간적 분포에 따른 우수유출특성 분석)

  • Yeon, Jong Sang;Jang, Young Su;Lee, Jae Hyuk;Shin, Hyun Suk;Kim, Eung Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3983-3989
    • /
    • 2014
  • As the storm water runoff characteristics in urban areas have changed owing to urbanization, centralized facilities to reduce the urban flood runoff had been implemented. On the other hand, because they have their limitations, LID (Low Impact Development) of the distributed facilities for storm water runoff reduction is being actively planned and applied. The purpose of this study was to analyze the runoff characteristics for the spatial distribution of typical LID element techniques. This study set a study basin consisting of the five subbasins with the same basin and drainage systems, and analyzed the flood runoff characteristics from the two scenarios, one is for the locations and the other is for the number of green roofs (GR) and permeable pavement (PP), respectively, selected as typical LID element techniques. The SWMM implementation results showed that GR reduces 11.07% of the total and 3.42% of the peak amounts of storm water runoff, and PP leads to 18.09% of the total and 17.94% of the peak discharge reduction for a subbasin. Such a reduction rate is constant regardless of the LID locations, and increases linearly with the number of LID applications. The different runoff reduction rates between the GR and PP applications appear to be due to the effects of the different hydraulic conductivities in the control parameters for each LID.

A Study on the Peak Runoff Reduction Effect of Seolleung·Jeongneung Zone by Applying LID(Low Impact Development) System based on the Landscape Architectural Technology (조경기술기반 LID 시스템 적용을 통한 선릉·정릉 권역의 첨두유출량 분석)

  • Kim, Tae-Han;Choi, Jong-Hee
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.35 no.4
    • /
    • pp.126-133
    • /
    • 2017
  • This study analyzed hydrological changes of stormwater runoff of Seolleung Jeongneung zone according to the application of LID system based on landscape Architectural technology. The results are as follows. First, when flooding occurred in Gwanghwamun in July 27, 2011, the maximum instantaneous rainfall amount was 183 mm/hr recorded at 10:00 on 27th for 10 minutes, and it was confirmed that rainfall intensity more than three times as high as the maximum rainfall of 57.5 mm/hr. Second, it is possible to control peak flow rate in the case of 1,500mm of soil thickness, so that it is possible to improve the vulnerability of flood damage in Seolleung and Jeongneung zone when applying the LID system. Third, in the berm height scenario, peak flow rate control was not controled in all depth level models, but the first stormwater runoff was delayed by 4 hours and 10 minutes compared to the soil thickness scenario. It was interpreted as a relatively important indicator the soil thickness for the initial stromwater runoff reduction and the berm height for the peak runoff. Through this, the systematic adaptation of landscape-friendly ecological factors within the cultural property protection zone could theoretically confirm the effects of flood disaster prevention.

Evaluation for Non-Point Sources Reduction Effect by Vegetated Ridge and Silt Fence (식생밭두렁과 실트펜스를 이용한 밭 비점오염 저감효과 평가)

  • Kim, Dong-Hyeon;Kim, Sang-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.129-137
    • /
    • 2015
  • The objective of this study was to test the non-point source pollution (NPS) control by the vegetated ridge and silt fence through field monitoring. The experiment plots were established with three sizes which are 5 m width by 22 m length with 8 %, 3 % slope and 15m width by 15 m length with 6 % slope. Flumes with the floating type stage gages were installed at the outlet of each plot to monitor the runoff. For a rainfall monitoring, tipping bucket rain gage was installed within the experiment site. Water quality samples were monitored during the heavy rainfall occurred. The amount of rainfall from 4 monitored events ranged from 27.6 mm to 130 mm. The runoff reduction rate could vary depending on slope, soil, crop growth condition, rainfall amount, rainfall intensity, antecedent moisture condition, and many other factors. The runoff from vegetated ridge and silt fence treatment plots was 24.05 % and -8.28 % lower than that from control plot, respectively. The monitoring results showed that the average pollution loads reduced by vegetated ridge compared to control were BOD 36.62~53.60 %, SS 40.41~73.71 %, COD 39.34~56.41 %, DOC 49.08~53.67 %, TN 26.74~67.23 %, and TP 52.72~91.80 %; by silt fence compared to control were SS 41.73 %, COD 1.93 %, and TN 2.38 %. The paired t-test result indicated that the vegetated ridge and silt fence were statistically significant effect in SS load reduction, with a 5 % significant level. Monitored results indicated that vegetated ridge and silt fence were both effective to reduce the pollutant from the field surface runoff.

An Experimental Study on Improvement of the Effect for Runoff Reducing Facilities Using Infiltration (침투형 우수유출 저감시설의 저감효과 개선에 관한 실험 연구 : 누가침투량 분석에 의한 침투-저류시스템 제안)

  • Im, Janghyuk;Song, Jaiwoo;Park, Youngjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.4
    • /
    • pp.5-13
    • /
    • 2009
  • The runoff-reducing facilities using infiltration was considered for the sustainable and sound water management. However, for practical utilization, many problems are attended and therefore effort on improvements are required. In this study, methods of improvement for infiltration facilities proposed by Infiltration-Storage System (ISS) and the effect of runoff reduction were analyzed by hydraulic experimental study. In order to analyze the infiltration characteristics of proposed runoff reduction facilities in this study, it was applied to various rainfall condition and surface material considering development and urbanization influences. As a results of hydraulic model experiment, Infiltration-Storage System (ISS) made addition to effect of reduction by lower layer of accumulative infiltration quantities. And then as rainfall-intensity was increased, accumulative infiltration rates were increased in this study. Thus, Infiltration-Storage system (ISS) was more efficient than existing runoff reduction facilities because of increasing infiltration rate. Such a result was guaranteed application of ISS as runoff-reducing facilities. Therefore, ISS is expected to be capable for practical application if subsequent research for improvements are followed. Additionally, results of this study are expected to provide fundamental research data on infiltration facilities.

  • PDF