• 제목/요약/키워드: Runner imbalance

검색결과 41건 처리시간 0.022초

다수 캐비티 사출금형에서 충전 균형을 위한 런너의 설계 (Runner Design for Filling Balance in Multi-cavity Injection Mold)

  • 강민아;류민영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 춘계학술대회 논문집
    • /
    • pp.329-332
    • /
    • 2008
  • Flow imbalance among the cavities was often observed in multi-cavity mold. The flow imbalance affects on the dimensions and physical properties of melded articles. First of all, the origin of flow imbalance is geometrical imbalance of delivery system. However, even the geometry of delivery system is balanced the cavity imbalance is being developed. This comes from the temperature distribution in the cross-section of runner, which is affected by the operational conditions. In this study, experimental study of flow imbalance has been conducted for various injection speeds. This study also suggests new runner design to eliminate flow imbalance in multi-cavity injection mold. Simulation and experimental results showed suggested new designed runner could eliminate or reduce flow imbalance in multi-cavity injection mold.

  • PDF

편측 분기형 러너 배열을 가진 다수 캐비티 사출금형에서의 충전 불균형도 (The Filling Imbalance in Multi-Cavity Injection Molds with Unary Branch Type Runner Lay-out)

  • 강철민;정영득
    • 소성∙가공
    • /
    • 제13권7호
    • /
    • pp.580-585
    • /
    • 2004
  • Almost all injection molds have multi-cavity runner system fur productivity and are designed with geometrically balanced runner system in order to minimize filling imbalance between cavity to cavity during processing. However, filling imbalances have been observed though geometrically balanced runner lay-out. Generally, these filling imbalances are due to thermal unbalance, viscosity, characteristic of polymers and so on. These kinds of filling imbalances have already been reported by Beaumont since 1997, but his research has mainly focused on filling imbalance at binary runner. In this study, we conducted an experimental study about the filling imbalances in unary branch runner as well as binary branch runner and inquired into the causes of filling imbalances. The results could be summarized as fellowing: Filling imbalances existed in multi-cavity mold with unary branch runner, it could be decreased by optimizing processing condition such as increasing injection rate, and it is almost proportion to each polymer's temperature sensibility.

다점 핀포인트 금형에서 균형충전이 가능한 사출금형 구조 (On the new mold structure with multi-point gate for filling-balance mold)

  • 권윤숙;정영득
    • Design & Manufacturing
    • /
    • 제2권5호
    • /
    • pp.25-29
    • /
    • 2008
  • Almost all injection molds have multi-cavity runner system for mass production, which are designed with geometrically balanced runner system in order to accomplish filling balance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalance have been observed. Filling imbalance could be decreased by modifying processing conditions such as injections rate, mold temperature, injection pressure, melt temperature that are related to shear, viscosity. In this study, a series of experiment was conducted to investigate filling imbalance variation when modifying runner layout and ploymer and to determine which processing condition influences as the primary cause of filling imbalance in geometrically balanced runner system. The filling imbalance was desreased up to result range of $3{\leq}DFI{\leq}8(%)$ by using a new runner system for balanced filling.

  • PDF

다수 캐비티 사출금형에서 충전 불균형 원인 분석 및 스크류 런너 디자인 (A study on coupling effect during lifting)

  • 강민아;김혜연;류민영
    • 한국금형공학회:학술대회논문집
    • /
    • 한국금형공학회 2008년도 하계 학술대회
    • /
    • pp.155-158
    • /
    • 2008
  • Flow imbalance among the cavities was often observed in multi-cavity mold. The flow imbalance affects on the dimensions and physical properties of molded articles. First of all, the origin of flow imbalance is geometrical imbalance of delivery system. However, even the geometry of delivery system is balanced the cavity imbalance is being developed. This comes from the temperature distribution in the cross-section of runner, which is affected by the operational conditions. In this study, experimental study of flow imbalance has been conducted for various injection speeds. This study also suggests new runner design to eliminate flow imbalance in multi-cavity injection mold. Simulation and experimental results showed suggested new designed runner could eliminate or reduce flow imbalance in multi-cavity injection mold.

  • PDF

다수 캐비티 사출금형에서 러너 코어핀이 충전불균형에 미치는 영향 (The Effects of Runner Core Pin on the Filling Imbalance Occurred in Multi Cavity Injection Mold)

  • 강철민;정영득;한규택
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.39-42
    • /
    • 2005
  • For mass production, usually injection mold has multi-cavity which is filled through geometrical balanced runner system. Despite geometrical balanced runner system, filling imbalances between cavity to cavity have always been observed. These filling imbalances are one of the most significant factors to affect quality of plastic parts when molding plastic parts in multi-cavity injection mold. Filling imbalances are results from non-symmetrical shear rate distribution within melt as it flows through the runner system. It has been possible to decrease filling imbalance by optimizing processing conditions, but it has not completely eliminated this phenomenon during injection molding processing. This paper presents a solution of these filling imbalances through using 'runner core pin'. The runner core pin which is developed in this study creates a symmetrical shear distribution within runner. As a result of using runner core pin, a remarkable improvement in reducing filling imbalance was confirmed.

  • PDF

러너 코어핀 형상이 PA6 성형품의 충전불균형도에 미치는 영향 (Effects of Core Pin Shape on the Filling Imbalances of PA6 Molding)

  • 정영득;강철민;제덕근
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.706-709
    • /
    • 2005
  • Despite geometrical balanced runner system, filling imbalances between cavity to cavity have always been observed in multi-cavity injection mold. These filling imbalances are results from non-symmetrical shear rate distribution within melt as it flows through the runner system. It has been possible to decrease filling imbalance by optimizing processing conditions, but it has not completely eliminated this phenomenon during the injection molding processing. This paper presents a solution of these filling imbalances by using runner core pin which creates a symmetrical shear distribution within runner and the effects on filling imbalance when modifying a shape of runner core pin. As a result of using runner core pin, a remarkable improvement in reducing filling imbalance was confirmed. In addition we investigated how filling imbalances were affected by shape of runner core pin.

  • PDF

균형충전을 위한 HR3P 금형 구조에서의 공정의 최적화 (Optimization of Processing on Filling Balance of the HR3P Mold Structure)

  • 권윤숙;정영득
    • 한국정밀공학회지
    • /
    • 제26권3호
    • /
    • pp.98-102
    • /
    • 2009
  • Almost all injection molds have multi-cavity runner system for mass production, which are designed with geometrically balanced runner system in order to accomplish filling balance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalance has been observed. Filling imbalance could be decreased by modifying processing conditions such as injections rate, mold temperature, injection pressure, melt temperature that are related to shear, viscosity. In this study, a series of experiment was conducted to investigate filling imbalance variation when modifying runner layout and polymer and to determine which processing condition influences as the primary cause of filling imbalance in geometrically balanced runner system. The filling imbalance was decreased up to result range of $3{\leq}DFI{\leq}8(%)$ by using a new runner system for balanced filling.

사출성형시 불균형 충전에 관한 다구찌 실험계획법을 이용한 성형공정의 최적화 (On the new mold structure with multi-point gate for filling-balance mold)

  • 권윤숙;한동엽;정영득
    • Design & Manufacturing
    • /
    • 제1권1호
    • /
    • pp.13-16
    • /
    • 2007
  • Almost all injection molds have multi-cavity runner system for mass production, which are designed with geometrically balanced runner system in order to accomplish filling balance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalance have been observed. Filling imbalance could be decreased by modifying processing conditions such as injections rate, mold temperature, injection pressure, melt temperature that are related to shear, viscosity. In this study, a series of experiment was conducted to investigate filling imbalance variation when modifying runner layout and polymer and to determine which processing condition influences as the primary cause of filling imbalance in geometrically balanced runner system.

  • PDF

사출금형의 러너시스템 형상에 따른 균형 충전도 (Degree of Filling Balance according to Runner Shapes in Injection Mold)

  • 한동엽;정영득
    • Design & Manufacturing
    • /
    • 제6권1호
    • /
    • pp.52-57
    • /
    • 2012
  • Aspect of filling imbalance that is originated from imbalanced share rate in runner is changed by material property, runner layout that are factors of changing viscosity and by injection pressure, injection speed, melt temperature and mold temperature that are injection conditions. In this paper, we made a study of runner system that is one of factor of filling imbalance and Sharp Conner Effect and Groove Corner Effect that are recently released. The study are showed that filling rate of between inside and outside cavity was influenced on shape of runner. Also, we suggested runner system for filling imbalance by adapting the two effects at multi cavity of unary branch type and theoretical investigated flow in the Shrap Conner runner type.

  • PDF

사출금형의 러너시스템 형상에 따른 충전불균형 유동해석 모델 (Flow Analysis of Filling Imbalance according to Runner Shapes in Injection Mold)

  • 장민규;고승우;김영민;노병수;정영득
    • Design & Manufacturing
    • /
    • 제2권5호
    • /
    • pp.16-20
    • /
    • 2008
  • Almost all injection molds have multi-cavity runner system for mass production, which are designed with geometrically balanced runner system in order to accomplish filling balance between cavity to cavity during processing; However, even though geometrically balanced runner is used, filling imbalances have been observed. In these day, the CAE has been used widely in injection molding. However, CAE with fusion mesh can't indicate such as jetting, flow mark and filling imbalance in multi cavity mold. In this study, we investigated the filling imbalance according to runner shapes by CAE analysis. As a result in CAE, in case of binary branch runner system, filling imbalance was indicated between cavity to cavity, but the flow pattern of each cavity uniformed in unary branch runner system.

  • PDF