• Title/Summary/Keyword: Rotor Winding

Search Result 254, Processing Time 0.029 seconds

Radial Force Control of a Novel Hybrid Pole BLSRM

  • Wang, Hui-Jun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.845-853
    • /
    • 2009
  • This paper presents a novel hybrid pole BLSRM (Bearingless Switched Reluctance Motor) and its radial force control scheme. The proposed hybrid pole BLSRM has separated radial force poles and rotating torque poles. According to the FEM analysis, the proposed BLSRM has an excellent linear characteristic of radial force and controllability that is independent from the torque current. The radial force can be produced by the radial force winding which is wound at the separated radial force poles. The rotating torque is produced by the excitation current of the torque windings which are wound at the torque pole. The proposed radial force control scheme is independent of the phase torque winding current. A simple PID controller and look-up table are used to maintain a constant rotor air-gap. The proposed BLSRM and its radial force control scheme are verified by FEM analysis and experimental tests.

Drive Controller System in PM Motor with Independently Excited Winding for an Electric Bicycle (전기자전거용 독립여자권선 영구자석 전동기의 구동제어기 설계)

  • Choi, Jin-Wook;Son, Young-Dae;Kang, Gyu-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.175-177
    • /
    • 2007
  • This paper presents for the torque characteristics and improving the efficiency of driving system of electric bicycle which applied IEWPM(Independently Excited Winding Permanent Magnet) motor. IEWPM motor can expand the number of phase from 3 phases to multiphase like SRM motor because stator windings are unconnected directly. BLDC motor raise rotor'-s electromagnetic torque per unit volume by using Spoke type permanent magnet. By using two photo sensor per phase and applying excited width, advance angle and bipolar control, we confirmed higher torque at a low speed, higher out-put at a high speed, and efficiency improvement at a wide speed control area.

  • PDF

A Study on the Fault Current of Distribution System according to Connection of Wind Turbine Generation Grid-Connected Transformer (풍력발전 계통연계 변압기의 결선에 따른 배전계통의 고장전류에 관한 연구)

  • An, Hae-Joon;Ro, Kyoung-Soo;Kim, Hyun-Goo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.369-371
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

A comparison of transient electromagnetic analysis and experiment result of Limeted angle torque motor (Limeted angle torgue motor의 전자기 과도해석 및 실험 결과의 비교)

  • Kim, Yong-Hoon;Kwon, Soon-O;Lee, Suwoong;Jang, Seung-Gyo;Kim, Young-Bok
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.898-899
    • /
    • 2015
  • This paper present a transient experiment to verify the performance of limited angle torque motor(LATM) designed using electromagnetic transient analysis. LATM requires access to the transitional state to the torque performance evaluation. Because LATM moves the rotor using a magnetic torque generated by the interaction of the permanent magnet and the armature winding. A separate control is not applied, it is switched on at the same time under the conditions that the current applied to the armature winding. It was compared to the transient analysis of the experimental data of LATM for the verification of approach method in the transitional state.

  • PDF

Design Methodology for Minimal Stator Copper Loss in A Single-phase Induction Motor (단상 유도전동기의 고정자 동손 최소화를 위한 설계 방법)

  • Baek, Soo-Whang;Kim, Byung-Taek;Kwon, Byung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1536-1545
    • /
    • 2008
  • In this paper, we research a new method for efficiency improvement of a single-phase Induction motor by minimization of the stator loss. To make this, we perform winding design which is based on balanced and quasi-balanced operation condition. It gives efficiency improvement greatly but poor starting torque simultaneously. To obtain the best efficiency improvement maintaining the maximum and starting torque, the optimal winding specification and rotor dimension is determined with variation of secondary resistance, running capacitor and turn ratio. Finally, this paper gives the comparison between the simulation results and experimental results.

On-Line Diagnosis Method for Generator Rotor Windings (발전기 운전중 회전자 진단에 관한 연구)

  • Lee, Young-Jun;Kong, Tae-Sik;Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1846-1849
    • /
    • 2002
  • A shorted-turn test was performed at the Sininchon combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line diagnosis system. The flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change of the flux. This pattern of flux variation is a signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF

Test results of a 5 kW fully superconducting homopolar motor

  • Lee, J.K.;Park, S.H.;Kim, Y.;Lee, S.;Joo, H.G.;Kim, W.S.;Choi, K.;Hahn, S.Y.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.1
    • /
    • pp.35-39
    • /
    • 2013
  • The superconducting Homopolar motor is manufactured and tested. Homopolar motor system is simple and solid as the field coil of the motor is fixed near the stator coil without rotating system. In this paper, a 5 kW fully superconducting homopolar motor which has high temperature superconducting armature and field coils is manufactured and tested in liquid nitrogen. The critical current test results of the used 2G superconducting wire, pancake coil for rotor winding and race-track coils for armature winding are reported. Also, the test result of rotating and operating performance is presented. The operating frequency is to be 5 Hz for low-speed rotating. The developed fully superconducting Homopolar motor is the world's first.

Shorted-Turn Detction Techniques for Generator Rotor (발전기 운전중 회전자 계자권선의 단락 진단기법에 관한 연구)

  • Lee, Young-Jun;Kim, Hee-Dong;Park, Jong-Jeong;Ju, Young-Ho;Joe, Ji-Won;Lee, Byung-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1721-1724
    • /
    • 1998
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas. turbine generator #4. The test was conducted using a permanent flux probe and digital oscilloscope. The flux probe installed in the generator air gap, senses the field winding slot leakage flux and produces a voltage proportional to the rate of change of the flux. This pattern of flux variation is a signature unique to each field winding. We have also applied a waveform analysis technique that can identify the pole location, slot number, and number of shorted-Turns with each slot.

  • PDF

Development of Micro-Stepping Drive Circuit for 5-Phase Step Motor having Pentagon Type Winding (펜타곤 결선방식의 5상 하이브리드 스텝모터의 미세스텝 구동회로 개발)

  • Im, Sang-Duck;Choi, Jung-Keyng;Park, Seung-Yub;An, Ho-Gyun;Kim, Sei-Il
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.568-570
    • /
    • 1997
  • In this paper, we develope the micro-stepping driver circuit for 5-phase step motor having pentagon type winding and improve the position control performance of the rotor, $0.45^{\circ}$, $0.028125^{\circ}$, $0.0140625^{\circ}$ per step.

  • PDF

Assessment of Insulation Condition for Generator Rotor Windings (발전기 회전자 권선의 건전성 평가)

  • Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.59-60
    • /
    • 2006
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line shorted-turn diagnosis system. The permanent flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF