• Title/Summary/Keyword: Rotation time

Search Result 1,301, Processing Time 0.027 seconds

Representative Feature Extraction of Objects using VQ and Its Application to Content-based Image Retrieval (VQ를 이용한 영상의 객체 특징 추출과 이를 이용한 내용 기반 영상 검색)

  • Jang, Dong-Sik;Jung, Seh-Hwan;Yoo, Hun-Woo;Sohn, Yong--Jun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.7 no.6
    • /
    • pp.724-732
    • /
    • 2001
  • In this paper, a new method of feature extraction of major objects to represent an image using Vector Quantization(VQ) is proposed. The principal features of the image, which are used in a content-based image retrieval system, are color, texture, shape and spatial positions of objects. The representative color and texture features are extracted from the given image using VQ(Vector Quantization) clustering algorithm with a general feature extraction method of color and texture. Since these are used for content-based image retrieval and searched by objects, it is possible to search and retrieve some desirable images regardless of the position, rotation and size of objects. The experimental results show that the representative feature extraction time is much reduced by using VQ, and the highest retrieval rate is given as the weighted values of color and texture are set to 0.5 and 0.5, respectively, and the proposed method provides up to 90% precision and recall rate for 'person'query images.

  • PDF

Fast Implementations of Projector-Backprojector Pairs for Iterative Tomographic Reconstruction (반복법을 사용한 단층영상 재구성을 위한 투사기 및 역투사기의 고속 구현)

  • 김수미;이수진;김용호
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.473-480
    • /
    • 2003
  • Iterative reconstruction methods have played a prominent role in emission computed tomography due to their remarkable advantages over the conventional filtered backprojection method. However, since iterative reconstructions typically are comprised of repeatedly projecting and backprojecting the data, the computational load required for reconstructing an image depends highly on the performance of the projector-backprojector pair used in the algorithm. In this work we compare quantitative performance of representative methods for implementing projector-backprojector pairs. To reduce the overall cost for the projection-backprojection operations for each method, we investigate how previously computed results can be reused so that the number of redundant calculations can be minimized. Our experimental results demonstrate that the ray tracing method not only outperforms other methods in computation time, but also provides improved reconstructions with good accuracy.

Is a Suction Drain Necessary in Arthroscopic Rotator Cuff Repair?

  • Park, Jin-Young;Sim, Ju Hyun;Lee, Jae Hyung;Oh, Kyung Soo;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.137-142
    • /
    • 2016
  • Background: The purpose of this study was to evaluate the efficacy of suction drain use following arthroscopic rotator cuff repair by comparing early pain score and range of motion (ROM) between groups with and without suction drains. Methods: The study included 153 patients with rotator cuff tears who underwent arthroscopic repairs at our clinic from April 2014 to March 2015. Following surgery, a suction drain was used in 85 patients (group D) and not used in 68 patients (group ND). There was no statistical difference between the groups in terms of age, gender, or total operation time. The clinical outcome with regard to pain (assessed by pain scores and analgesic requests) and passive ROM was assessed preoperatively and postoperatively. Results: Immediate postoperative analgesic requirement was significantly higher in group D (p=0.001), although there was no difference in pain outcomes between the groups during the 3-month follow-up period. A statistically significant difference in passive ROM was observed at the postoperative 2- and 6-week follow-ups (p=0.036, 0.035, and 0.034 in forward elevation (FE), external rotation at the side (ER) and 90 ER at weeks 2, respectively; 0.045 and 0.009 in FE and ER at weeks 6, respectively); however no significant difference was observed at the end of 3 months. During the study period, no complication was reported in either group. Conclusions: Use of suction drains after arthroscopic rotator cuff repair provided little benefit in terms of ROM or pain in the early postoperative period (up to 3 months).

Analysis of Camera Rotation Using Three Symmetric Motion Vectors in Video Sequence (동영상에서의 세 대칭적 움직임벡터를 이용한 카메라 회전각 분석)

  • 문성헌;박영민;윤영우
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.2
    • /
    • pp.7-14
    • /
    • 2002
  • This paper proposes a camera motion estimation technique using special relations of motion vectors of geometrically symmetrical triple points of two consecutive views of single camera. The proposed technique uses camera-induced motion vectors and their relations other than feature points and epioplar constraints. As contrast to the time consuming iterations or numerical methods in the calculation of E-matrix or F-matrix induced by epipolar constraints, the proposed technique calculates camera motion parameters such as panning, tilting, rolling, and zooming at once by applying the proposed linear equation sets to the motion vectors. And by devised background discriminants, it effectively reflects only the background region into the calculation of motion parameters, thus making the calculation more accurate and fast enough to accommodate MPEG-4 requirements. Experimental results on various types of sequences show the validity and the broad applicability of the proposed technique.

  • PDF

Sequence Images Registration by using KLT Feature Detection and Tracking (KLT특징점 검출 및 추적에 의한 비디오영상등록)

  • Ochirbat, Sukhee;Park, Sang-Eon;Shin, Sung-Woong;Yoo, Hwan-Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.2
    • /
    • pp.49-56
    • /
    • 2008
  • Image registration is one of the critical techniques of image mosaic which has many applications such as generating panoramas, video monitoring, image rendering and reconstruction, etc. The fundamental tasks of image registration are point features extraction and tracking which take much computation time. KLT(Kanade-Lucas-Tomasi) feature tracker has proposed for extracting and tracking features through image sequences. The aim of this study is to demonstrate the usage of effective and robust KLT feature detector and tracker for an image registration using the sequence image frames captured by UAV video camera. In result, by using iterative implementation of the KLT tracker, the features extracted from the first frame of image sequences could be successfully tracked through all frames. The process of feature tracking in the various frames with rotation, translation and small scaling could be improved by a careful choice of the process condition and KLT pyramid implementation.

  • PDF

Vibration characteristics of endodontic motors with different motion: reciprocation and conventional rotation (왕복운동 및 회전운동 근관성형용 전동모터 간의 진동 양상 비교)

  • Jeon, Yeong-Ju;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee;Chang, Hoon-Sang
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.734-743
    • /
    • 2014
  • Objectives: By introduced reciprocation motion file in dentistry, dentists benefit simple canal shaping procedure and time-saving. But, reciprocation motion generates uncomfortable vibration to doctors and patients. Because there was no study about this consideration, this study compared vibration pattern and power generated from reciprocation motion motor and conventional rotary motor. Materials & Methods: One conventional rotary motor; X-Smart (Dentsply Maillefer, Ballaigues, Switzerland); and two reciprocating motors; WaveOne Motor (Dentsply Maillefer, Ballaigues, Switzerland) and X-SMART PLUS (Dentsply Maillefer, Ballaigues, Switzerland); were used in this study. Triaxial $ICP^{(R)}$ Accelerometer (Model 356A12, PCB piezotronics, New York, USA) was attached on motor's handpiece head, and was measured tri-axial vibratory acceleration with NI Sound and Vibration Assistant 2009 software (National Instruments, Texas, USA). Mean vibratory acceleration and maximum vibratory acceleration was measured on fixed position and handed position. The results of vibratory acceleration were statistically analyzed using ANOVA and multiple comparisons are made using Turkey's test at p<0.05 level. Results: Reciprocating motors showed higher mean vibratory acceleration and maximum vibratory acceleration than conventional rotary motor (p<0.05). Between reciprocating motors, X-SMART PLUS had lower mean vibratory acceleration and maximum vibratory acceleration than WaveOne Motor (p<0.05). Conclusion: Reciprocating motors generate more vibration than conventional rotary motor. Further study about effect of vibration to dentist and patient is needed. And it seems to be necessary to make a standard about vibration level in endodontic motors.

Effect of soil in controlling the seismic response of three-dimensional PBPD high-rise concrete structures

  • Mortezaie, Hamid;Rezaie, Freydoon
    • Structural Engineering and Mechanics
    • /
    • v.66 no.2
    • /
    • pp.217-227
    • /
    • 2018
  • In the last decades, valuable results have been reported regarding conventional passive, active, semi-active, and hybrid structural control systems on two-dimensional and a few three-dimensional shear buildings. In this research, using a three-dimensional finite element model of high-rise concrete structures, designed by performance based plastic design method, it was attempted to construct a relatively close to reality model of concrete structures equipped with Tuned Mass Damper (TMD) by considering the effect of soil-structure interaction (SSI), torsion effect, hysteresis behavior and cracking effect of concrete. In contrast to previous studies which have focused mainly on linearly designed structures, in this study, using performance-based plastic design (PBPD) design approach, nonlinear behavior of the structures was considered from the beginning of the design stage. Inelastic time history analysis on a detailed model of twenty-story concrete structure was performed under a far-field ground motion record set. The seismic responses of the structure by considering SSI effect are studied by eight main objective functions that are related to the performance of the structure, containing: lateral displacement, acceleration, inter-story drift, plastic energy dissipation, shear force, number of plastic hinges, local plastic energy and rotation of plastic hinges. The tuning problem of TMD based on tuned mass spectra is set by considering five of the eight previously described functions. Results reveal that the structural damage distribution range is retracted and inter-story drift distribution in height of the structure is more uniform. It is strongly suggested to consider the effect of SSI in structural design and analysis.

Treatment and retention of relapsed anterior open-bite with low tongue posture and tongue-tie: A 10-year follow-up

  • Seo, Yu-Jin;Kim, Su-Jung;Munkhshur, Janchivdorj;Chung, Kyu-Rhim;Ngan, Peter;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.44 no.4
    • /
    • pp.203-216
    • /
    • 2014
  • The purpose of the current report is to present 6-year long-term stability and 10-year follow-up data for an adult patient who was treated with a tongue elevator for relapsed anterior open-bite. The 19-year-old male patient presented with the chief complaint of difficulty in chewing his food. Collectively, clinical and radiographic examinations revealed an anterior open-bite, low tongue posture, and tongue-tie. The patient opted for orthodontic treatment alone, without any surgical procedure. A lingual frenectomy was recommended to avoid the risk of relapse, but the patient declined because he was not experiencing tongue discomfort. Initial treatment of the anterior open-bite with molar intrusion and tongue exercises was successful, but relapse occurred during the retention period. A tongue elevator was used for retreatment, because the approach was minimally invasive and suited the patient's requirements regarding discomfort, cost, and time. The appliance changed the tongue posture and generated an altered tongue force, which ultimately resulted in intrusive dentoalveolar effects, and a subsequent counterclockwise rotation of the mandible. The results showed long-term stability and were maintained for six years through continual use of the tongue elevator. The results of this case indicated that a tongue elevator could be used not only as an alternative treatment for open-bite, but also as an active retainer.

HK Curvature Descriptor-Based Surface Registration Method Between 3D Measurement Data and CT Data for Patient-to-CT Coordinate Matching of Image-Guided Surgery (영상 유도 수술의 환자 및 CT 데이터 좌표계 정렬을 위한 HK 곡률 기술자 기반 표면 정합 방법)

  • Kwon, Ki-Hoon;Lee, Seung-Hyun;Kim, Min Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.597-602
    • /
    • 2016
  • In image guided surgery, a patient registration process is a critical process for the successful operation, which is required to use pre-operative images such as CT and MRI during operation. Though several patient registration methods have been studied, we concentrate on one method that utilizes 3D surface measurement data in this paper. First, a hand-held 3D surface measurement device measures the surface of the patient, and secondly this data is matched with CT or MRI data using optimization algorithms. However, generally used ICP algorithm is very slow without a proper initial location and also suffers from local minimum problem. Usually, this problem is solved by manually providing the proper initial location before performing ICP. But, it has a disadvantage that an experience user has to perform the method and also takes a long time. In this paper, we propose a method that can accurately find the proper initial location automatically. The proposed method finds the proper initial location for ICP by converting 3D data to 2D curvature images and performing image matching. Curvature features are robust to the rotation, translation, and even some deformation. Also, the proposed method is faster than traditional methods because it performs 2D image matching instead of 3D point cloud matching.

The Influence of Scapular-Pelvic Patterns of Proprioceptive Neuromuscular Facilitation on Hemiplegic Gait -A Case Report- (PNF 어깨뼈-골반 패턴이 편마비 환자의 보행에 미치는 영향 -증례보고-)

  • Choi, Jae-Won;Hwang, Sin-Pil
    • PNF and Movement
    • /
    • v.16 no.1
    • /
    • pp.27-32
    • /
    • 2018
  • Purpose: This study examined changes in gait speed and stride length after an intervention involving simultaneous scapular and pelvic patterns of proprioceptive neuromuscular facilitation in a hemiplegic patient. Methods: A 58-year-old woman with left hemiplegia who had complained of slowness of gait speed and weakness of leg strength took part in an intervention involving scapular postdepression patterns on the affected side and pelvic postdepression patterns on the nonaffected side. The intervention was performed with the patient lying on her left side, in a half kneeling position, and in a standing posture. Rhythmic initiation was used for teaching the movements to the patient and improvement of kinesthesia, and a combination of isotonic was employed for increasing strength and irradiation of the scapula and pelvic movement. The intervention took place for 30 min. It was implemented twice a day, 5 days a week, for 3 weeks. After three repetitions, the average time taken to complete the 10-m walk test (10 MWT), in addition to stride length, was measured to determine gait speed. Results: After the 3-week program, the patient's performance in the 10 MWT improved from 21.7sec to 17.1sec, and her stride length improved from 31.4cm to 38.7cm. Conclusion: The results showed that trunk movement exercise, especially coordinative movements of the scapula and pelvis can improve gait speed and stride length by increasing trunk stability and mobility. A combination of pelvic and scapular patterns can facilitate trunk rotation, thereby improving gait speed and stride length.