• Title/Summary/Keyword: Rotation system

Search Result 2,052, Processing Time 0.029 seconds

Effects of Tensor Fasciae Latae-Iliotibial Band Self-Stretching on Lumbopelvic Movement Patterns During Active Prone Hip Lateral Rotation in Subjects With Lumbar Extension Rotation Syndrome

  • Lim, One-Bin;Yi, Chung-Hwi;Kwon, Oh-Yun;Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.19 no.4
    • /
    • pp.61-69
    • /
    • 2012
  • The purpose of this study was to identify the effects of tensor fasciae latae-iliotibial band (TFL-ITB) self-stretching exercise on the lumbopelvic movement patterns during active prone hip lateral rotation (HLR) in subjects with lumbar extension rotation syndrome accompanying TFL-ITB shortness. Eleven subjects (9 male and 2 female) were recruited for the two-week study. A three dimensional ultrasonic motion analysis system was used to measure the lumbopelvic movement patterns. The TFL-ITB length was measured using the modified Ober's test and was expressed as the hip horizontal adduction angle. The subjects were instructed how to perform TFL-ITB self-stretching exercise program at home. A paired t-test was performed to determine the significant difference in the angle of lumbopelvic rotation, movement onset time of lumbopelvic rotation, TFL-ITB length, and LBP intensity before and after the two-week period of performing the TFL-ITB self-stretching exercise. The results showed that after the intervention, the lumbopelvic rotation angle decreased significantly (p<.05), the movement onset time reduced significantly (p<.05), and LBP intensity decreased slightly but not significantly (p=.07). The hip horizontal adduction angle increased significantly (p<.05) after the intervention. These findings indicate that TFL-ITB stretching exercise increased TFL-ITB length, decreased lumbopelvic rotation angle, and delayed the movement onset time of lumbopelvic rotation after two-weeks. In conclusion, the TFL-ITB self-stretching exercise performed over a period of two weeks may be an effective approach for patients with lumbar extension rotation syndrome accompanying TFL-ITB shortness.

Rotation Control of Shoulder Joint During Shoulder Internal Rotation: A Comparative Study of Individuals With and Without Restricted Range of Motion

  • Min-jeong Chang;Jun-hee Kim;Ui-jae Hwang;Il-kyu Ahn;Oh-yun Kwon
    • Physical Therapy Korea
    • /
    • v.31 no.1
    • /
    • pp.72-78
    • /
    • 2024
  • Background: Limitations of shoulder range of motion (ROM), particularly shoulder internal rotation (SIR), are commonly associated with musculoskeletal disorders in both the general population and athletes. The limitation can result in connective tissue lesions such as superior labrum tears and symptoms such as rotator cuff tears and shoulder impingement syndrome. Maintaining the center of rotation of the glenohumeral joint during SIR can be challenging due to the compensatory scapulothoracic movement and anterior displacement of the humeral head. Therefore, observing the path of the instantaneous center of rotation (PICR) using the olecranon as a marker during SIR may provide valuable insights into understanding the dynamics of the shoulder joint. Objects: The aim of the study was to compare the displacement of the olecranon to measure the rotation control of the humeral head during SIR in individuals with and without restricted SIR ROM. Methods: Twenty-four participants with and without restricted SIR ROM participated in this study. The displacement of olecranon was measured during the shoulder internal rotation control test (SIRCT) using a Kinovea (ver. 0.8.15, Kinovea), the 2-dimensional marker tracking analysis system. An independent t-test was used to compare the horizontal and vertical displacement of the olecranon marker between individuals with and without restricted SIR ROM. The statistical significance was set at p < 0.05. Results: Vertical displacement of the olecranon was significantly greater in the restricted SIR group than in the control group (p < 0.05). However, no significant difference was observed in the horizontal displacement of the olecranon (p > 0.05). Conclusion: The findings of this study indicated that individuals with restricted SIR ROM had significantly greater vertical displacement of the olecranon. The results suggest that the limitation of SIR ROM may lead to difficulty in rotation control of the humeral head.

Biomechanical changes in lower quadrant after manipulation of low back pain patients with sacroiliac joint dysfunction (요통환자의 엉치엉덩관절 기능부전에 대한 도수교정 후에 하지의 생체역학적인 변화)

  • Oh, Seung-Gil;Yoo, Seung-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.1
    • /
    • pp.893-906
    • /
    • 2001
  • The purposes of this study were to compare pelvic tilt. range of motion(ROM) of hip rotation, and leg length difference before and after manipulation and to investigate correlation between changes of each variables after manipulation of sacroiliac pint in 31 low back pain patients(11 males, 20 females) with sacroiliac pint dysfunction. The sacroiliac pint of patients was manipulated on the side of anterior pelvic tilt, using the technique described by Stoddard(1962) and Greenmann (1996). I used this technique because it usually eliminated sacroiliac Pint dysfunction in one treatment session. SPSS for window computer system was used to analyze the data. Also t-test was performed for comparison of the variables before and after manipulation, and Pearson product-moment correlation analysis and regression analysis were performed for changes of each variables after manipulation. The result were as follows: 1. The pelvic tilt after manipulation was significantly decreased(mean=$2.79^{\circ}$) compared with the pelvic tilt before manipulation(p=.001). 2. The PROM of hip internal rotation ipsilateral to anterior pelvic tilt after manipulation significantly decreased (mean = $1.88^{\circ}$) compared with hip internal rotation before manipulation (p=.008). The PROM of hip internal rotation ipsilateral to posterior pelvic tilt after manipulation significantly increased(mean = $1.29^{\circ}$) compared with hip internal rotation before manipulation (p=.029). 3. The PROM of hip external rotation ipsilateral to anterior pelvic tilt after manipulation significantly increased(mean=$2.42^{\circ}$) compared with the hip external rotation before manipulation(p=$2.42^{\circ}$) compared with the hip external rotation ipsilateral to posterior pelvic tilt after manipulation significantly decreased(mean = $1.84^{\circ}$) compared with the hip external rotation before manipulation (p=.008). 4. Leg length difference after manipulation significantly decreased(mean=2.15 mm) compared with leg length difference before manipulation (p=.008). Regression analysis revealed that a fair correlation was found between change in leg length difference and change in anterior pelvic tilt after manipulation(p=.009). 5. Pearson product-moment correlation coefficient was used to assess differences of the variables after manipulation. A fair correlation was found between change in leg length difference and change in anterior pelvic tilt after manipulation(r=.462, p<.01). A fair correlation was found between change in anterior pelvic tilt and change in hip internal rotation ipsilateral to anterior pelvic tilt(r=.397, p<.05) and between change in anterior pelvic tilt and change in hip external rotation ipsilateral to anterior pelvic tilt(r=.516, p<.01). A fair correlation was found between change in posterior pelvic tilt and changes in hip internal rotation ipsilateral to posterior pelvic tilt (r=.441, p<.05) and between change in posterior pelvic tilt and change in hip external rotation ipsilateral to posterior pelvic tilt(r=.361, p<.05). A fair correlation was found between change in hip internal rotation ipsilateral to anterior pelvic tilt and change in hip external rotation ipsilateral to posterior pelvic tilt(r=.388, p<.05) and between change in hip internal rotation ipsilateral to posterior pelvic tilt and change in hip internal rotation ipsilateral to anterior pelvic tilt(r=.426. p<.05).

  • PDF

Comparison of transverse dental changes induced by the palatally applied Frog appliance and buccally applied Karad's integrated distalizing system

  • Uzuner, Fatma Deniz;Kaygisiz, Emine;Unver, Fatih;Tortop, Tuba
    • The korean journal of orthodontics
    • /
    • v.46 no.2
    • /
    • pp.96-103
    • /
    • 2016
  • Objective: To compare the transverse dental changes induced by the palatally applied Frog appliance and buccally applied Karad's integrated distalizing system (KIDS). Methods: We evaluated the pre- and post distalization orthodontic models of 39 patients, including 19 treated using the Frog appliance, which is palatally positioned (Frog group), and 20 treated using KIDS, which is buccally positioned (KIDS group). Changes in intermolar and interpremolar distances and the amount of maxillary premolar and molar rotation were evaluated on model photocopies. Wilcoxon and Mann-Whitney U tests were used for statistical evaluations. A p-value of < 0.05 was considered statistically significant. Results: Significant distopalatal rotation of premolars and distobuccal rotation of molars were observed in Frog group (p < 0.05), while significant distopalatal rotation of molars (p < 0.05), with no significant changes in premolars, was observed in KIDS group. The amount of second premolar and first molar rotation was significantly different between the two groups (p < 0.05 and p < 0.001, respectively). Furthermore, expansion in the region of the first molars and second premolars was significantly greater in KIDS group than in Frog group (p < 0.001 for both). Conclusions: Our results suggest that the type and amount of first molar rotation and expansion vary with the design of the distalization appliance used.

Rotation and Translation Invariant Feature Extraction Using Angular Projection in Frequency Domain (주파수 영역에서 각도 투영법을 이용한 회전 및 천이 불변 특징 추출)

  • Lee, Bum-Shik;Kim, Mun-Churl
    • Journal of the HCI Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.27-33
    • /
    • 2006
  • This paper presents a new approach to translation and rotation invariant feature extraction for image texture retrieval. For the rotation invariant feature extraction, we invent angular projection along angular frequency in Polar coordinate system. The translation and rotation invariant feature vector for representing texture images is constructed by the averaged magnitude and the standard deviations of the magnitude of the Fourier transform spectrum obtained by the proposed angular projection. In order to easily implement the angular projection, the Radon transform is employed to obtain the Fourier transform spectrum of images in the Polar coordinate system. Then, angular projection is applied to extract the feature vector. We present our experimental results to show the robustness against the image rotation and the discriminatory capability for different texture images using MPEG-7 data set. Our Experiment result shows that the proposed rotation and translation invariant feature vector is effective in retrieval performance for the texture images with homogeneity, isotropy and local directionality.

  • PDF

Concurrent Validity and Clinical Usefulness of Universal Plastic Goniometer for Hip Internal and External Rotation Range Measurement (고관절 내외회전 가동범위 검사에 대한 범용플라스틱 측각기의 동시타당도와 임상적 유용성)

  • Kim, Yong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.1
    • /
    • pp.99-105
    • /
    • 2018
  • PURPOSE: The aim of this study was to evaluate the concurrent validity and clinical usefulness of the universal plastic goniometer to measure the range of motion of the internal and external rotation of the hip joint using the three dimensional motion analysis which can analyze the joints and segment movements in the most objective and quantitative method. METHODS: Clinical and kinematic data were collected from thirty individuals using a universal plastic goniometer and a ten camera motion analysis system. Passive hip rotation range was obtained three trials for left and right hip joints using two measure methods simultaneously. RESULTS: There were significant differences between all matching measures of the two measures of internal and external rotation of the hip joint (p<.05). The relationship between the two tests for all measurements of the internal and external rotation of the hip was statistically significant with correlation coefficient form r=.87 to .96. (p<.01). CONCLUSION: Clinical measurement of the internal and external rotation of the hip using a universal plastic goniometer is effective to assess the hip condition. However, application of universal plastic goniometer requires careful attention in more accurate evaluation and research verification of the internal and external rotation of hip joint.

A Sensing System of the Halbach Array Permanent Magnet Spherical Motor Based on 3-D Hall Sensor

  • Li, Hongfeng;Liu, Wenjun;Li, Bin
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.352-361
    • /
    • 2018
  • This paper proposes a sensing system of the Halbach array permanent magnet spherical motor(PMSM). The rotor position can be obtained by solving three rotation angles, which revolves around 3 reference axes of the stator. With the development of 3-D hall sensor, the position identification problem of the Halbach array PMSM based on rotor magnetic field is studied in this paper. A nonlinear and serious coupling relationship between the rotation angles and the measured magnetic flux density is established on the basis of the rotation transformation theory and the magnetic field model. In order to get rid of the influence on position detection caused by the harmonics of rotor magnetic field and the stator coil magnetic field, a sensor location combination scheme is proposed. In order to solve the nonlinear equation fast and accurately, a new position solution algorithm which combines the merits of gradient projection and particle swarm optimization(PSO) is presented. Then the rotation angles are obtained and the rotor position is identified. The validity of the sensing system is verified through the simulation.

A development of automatic detecting equipment for rotation axis of golf ball (골프공 회전 무게중심 검출 시스템)

  • Lee, Jae-woong;Hyun, Woong-keun;Oh, Jun-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.540-545
    • /
    • 2016
  • Many golf balls have wrong rotation axis owing to bad production and scratch. A flying golf ball makes sliced or curved motion mainly to owing the wrong rotation axis of golf ball. Dimples of golf ball make a golf ball higher and more straight flying. When we hit a golf ball by driver or iron club, the dimpled ball flies straight and rotates as well. While the ball flying, the rotating axis of the ball convergence. And this makes the ball motion curved. If we hit a golf ball in direction of the rotation axis, the flying ball makes straight motion. In this paper, we develop a control system to detect convergence axis and time of flying golf ball based on vision system. To show validity of the developed system, We experimented several case for dimpled golf balls.

  • PDF

Tension Control Tunable Carbon Nanotube Resonator (장력제어를 통한 가변형 탄소나노튜브 공진기에 대한 연구)

  • Choi, Tae Ho;Lee, Jun Ha
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.2
    • /
    • pp.63-66
    • /
    • 2013
  • Carbon Nanotube have been proposed for use in various applications for electromechanical systems. Nano-electromechanical resonators which provide high frequency resolution and long energy storage time, play an important role in wide area fields of science and engineering. Using the control of tension in carbon nanotube, can be made the tunable resonator. In the study, we analysis the tunable frequency change of resonator by tension changes due to the rotation angles of the single-walled carbon nanotube resonator. The frequency characteristics of a resonator as a function of the rotation angle. The tension was found to decrease with increasing rotation angle, and therefore the resonance frequencies could be changed by controlling the single-walled carbon nanotube rotation angle. The resonance frequencies decreased with increasing angle, and when the rotation angle was greater than $60^{\circ}$, these changes were marked.

Development of Double Rotation C-Scanning System and Program for Under-Sodium Viewing of Sodium-Cooled Fast Reactor (소듐냉각고속로 소듐 내부 가시화를 위한 이중회전구동 C-스캔 시스템 및 프로그램 개발)

  • Joo, Young-Sang;Bae, Jin-Ho;Park, Chang-Gyu;Lee, Jae-Han;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.338-344
    • /
    • 2010
  • A double rotation C-scanning system and a software program Under-Sodium MultiVIEW have been developed for the under-sodium viewing of a reactor core and in-vessel structures of a sodium-cooled fast reactor KALIMER-600. Double rotation C-scanning system has been designed and manufactured by the reproduction of double rotation plug of a reactor head in KALIMER-600. Hardware system which consists of a double rotating scanner, ultrasonic waveguide sensors, a high power ultrasonic pulser-receiver, a scanner driving module and a multi channel A/D board have been constructed. The functions of scanner control, image mapping and signal processing of Under-Sodium MultiVIEW program have been implemented by using a LabVIEW graphical programming language. The performance of Under-Sodium MultiVIEW program was verified by a double rotation C-scanning test in water.