Browse > Article
http://dx.doi.org/10.13066/kspm.2018.13.1.99

Concurrent Validity and Clinical Usefulness of Universal Plastic Goniometer for Hip Internal and External Rotation Range Measurement  

Kim, Yong-Wook (Dept. of Physical Therapy, College of Medical Sciences, Jeonju University)
Publication Information
Journal of the Korean Society of Physical Medicine / v.13, no.1, 2018 , pp. 99-105 More about this Journal
Abstract
PURPOSE: The aim of this study was to evaluate the concurrent validity and clinical usefulness of the universal plastic goniometer to measure the range of motion of the internal and external rotation of the hip joint using the three dimensional motion analysis which can analyze the joints and segment movements in the most objective and quantitative method. METHODS: Clinical and kinematic data were collected from thirty individuals using a universal plastic goniometer and a ten camera motion analysis system. Passive hip rotation range was obtained three trials for left and right hip joints using two measure methods simultaneously. RESULTS: There were significant differences between all matching measures of the two measures of internal and external rotation of the hip joint (p<.05). The relationship between the two tests for all measurements of the internal and external rotation of the hip was statistically significant with correlation coefficient form r=.87 to .96. (p<.01). CONCLUSION: Clinical measurement of the internal and external rotation of the hip using a universal plastic goniometer is effective to assess the hip condition. However, application of universal plastic goniometer requires careful attention in more accurate evaluation and research verification of the internal and external rotation of hip joint.
Keywords
3D motion analysis; Goniometry; Hip joint; Range of motion;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Akiyama K, Nakata K, Kitada M, et al. Changes in axial alignment of the ipsilateral hip and knee after total hip arthroplasty. Bone Joint J. 2016;98-B:349-58.   DOI
2 Bagwell JJ, Bauer L, Gradoz M, et al. The reliability of FABER test hip range of motion measurements. Int J Sports Phys Ther. 2016;11(7):1101-5.
3 Bierma-Zeinstra SM, Bohnen AM, Ramlal R, et al. Comparison between two devices for measuring hip joint motions. Clin Rehabil. 1998 Dec;12(6):497-505.   DOI
4 Cibulka MT, Strube MJ, Meier D, et al. Symmetrical and asymmetrical hip rotation and its relationship to hip rotator muscle strength. Clin Biomech (Bristol, Avon). 2010;25(1):56-62.   DOI
5 Clapper MP, Wolf SL. Comparison of the reliability of the Orthoranger and the standard goniometer for assessing active lower extremity range of motion. Phys Ther. 1988;68(2):214-8.   DOI
6 Collins TD, Ghoussayni SN, Ewins DJ, et al. A six degrees-of-freedom marker set for gait analysis: repeatability and comparison with a modified Helen Hayes set. Gait Posture. 2009;30(2):173-80.   DOI
7 Damsted C, Nielsen RO, Larsen LH. Reliability of video-based quantification of the knee- and hip angle at foot strike during running. Int J Sports Phys Ther. 2015; 10(2):147-54.
8 Dujardin F, Selva O, Mejjad O, et al. Intra and inter individual variations of pelvic mobility in normal adult walk. Rev Chir Orthop Reparatrice Appar Mot. 1995; 81:592-600.
9 Grossman G, Waninger KN, Voloshin A, Reliability and validity of goniometric turnout measurements compared with MRI and retro-reflective markers. J Dance Med Sci. 2008;12(4):142-52.
10 Holm I, Bolstad B, Lutken T, et al. Reliability of goniometric measurements and visual estimates of hip ROM in patients with osteoarthrosis. Physiother Res Int. 2000;5(4):241-8.   DOI
11 Kim Y, Richards J, Lidtke RH, et al. Characteristics of clinical measurements between biomechanical responders and non-responders to a shoe designed for knee osteoarthritis. Gait Posture. 2018;59:23-7.   DOI
12 Kouyoumdjian P, Coulomb R, Sanchez T, et al. Clinical evaluation of hip joint rotation range of motion in adults. Orthop Traumatol Surg Res. 2012;98:17-23.   DOI
13 Cibulka MT. Determination and significance of femoral neck anteversion. Phys Ther. 2004;84:550-8.
14 Rowley KM, Richards JG. Increasing plantarflexion angle during landing reduces vertical ground reaction forces, loading rates and the hip's contribution to support moment within participants. J Sports Sci. 2015; 33(18):1922-31.   DOI
15 Krause DA, Hollman JH, Krych AJ, et al. Reliability of hip internal rotation range of motion measurement using a digital inclinometer. Knee Surg Sports Traumatol Arthrosc. 2015;23(9):2562-7.   DOI
16 Norris BS, Olson SL. Concurrent validity and reliability of two-dimensional video analysis of hip and knee joint motion during mechanical lifting. Physiother Theory Pract. 2011;27(7):521-30.
17 Nyland J, Kuzemchek S, Parks M, et al. Femoral anteversion influences vastus medialis and gluteus medius EMG amplitude: composite hip abductor EMG amplitude ratios during isometric combined hip abductionexternal rotation. J Electromyogr Kinesiol. 2004; 14:255-61.   DOI
18 Nussbaumer S, Leunig M, Glatthorn JF, et al. Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients. BMC Musculoskelet Disord. 2010;31(11):194.
19 Roach S, San Juan JG, Suprak DN, et al. Concurrent validity of digital inclinometer and universal goniometer in assessing passive hip mobility in healthy subjects. Int J Sports Phys Ther. 2013;8(5):680-8.
20 Shoji T, Yasunaga Y, Yamasaki T, et al. Low femoral antetorsion and total hip arthroplasty: a risk factor. Int Orthop. 2015;39:7-12.   DOI
21 Watelain E, Dujardin F, Babier F, et al. Pelvic and lower limb compensatory actions of subjects in an early stage of hip osteoarthritis. Arch Phys Med Rehabil. 2001;82:1705-11.   DOI
22 Wolf O, Mattsson P, Milbrink J, et al. Effects of postoperative weight-bearing on body composition and bone mineral density after uncemented total hip arthroplasty. J Rehabil Med. 2013;45(5):498-503.   DOI