• Title/Summary/Keyword: Rotation motion

Search Result 1,109, Processing Time 0.031 seconds

Biomechanical Effects of Posterior Dynamic Stabilization System on Lumbar Kinematics: A Finite Element Analysis (Posterior Dynamic Stabilization System의 요추거동에 대한 생체역학적 분석)

  • Ahn, Y.H.;Chen, Wen-Ming;Jung, D.Y.;Park, K.W.;Lee, S.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.139-145
    • /
    • 2008
  • Many recent studies suggest that the posterior dynamic stabilization(PDS) can be a more physiologically-relevant alternative to the rigid fixation for the patients suffering from low back pain. However, its biomechanical effects or clinically proven efficacies still remain unknown. In this study, we evaluated kinematic behaviors of the lower lumbar spine with the PDS system and then compared to those of the rigid fixation system using finite element (FE) analysis. A validated FE model of intact lumbar spine(L2-L5) was developed. The implanted model was then constructed after modification from the intact to simulate two kinds of pedicle screw systems (PDS and the rigid fixation). Hybrid protocol was used to flex, extend, laterally bend and axially rotate the FE model. Results showed that the PDS systems are more flexible than rigid fixation systems, yet not flexible enough to preserve motion. PDS system allowed $16.2{\sim}42.2%$ more intersegmental rotation than the rigid fixation at the implanted level. One the other hand, at the adjacent level it allowed more range of motion ($2.0%{\sim}8.3%$) than the rigid fixation. The center of rotation of the PDS model remained closer to that of the intact spine. These results suggest that the PDS system could be able to prevent excessive motion at the adjacent levels and restore the spinal kinematics.

Kinematic Analysis of Dynamic Stability Toward the Pelvis-spine Distortion during Running (달리기 시 체간의 골반-척추구조변형이 동적안정성에 미치는 연구)

  • Park, Gu-Tae;Yoo, Kyoung-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.4
    • /
    • pp.369-376
    • /
    • 2013
  • The purposes of this study were to assess dynamic stability toward pelvis-spine column distortion during running and to compare the typical three-dimensional angular kinematics of the trunk motion; cervical, thoracic, lumbar segment spine and the pelvis from the multi-segmental spine model between exercise group and non-exercise group. Subjects were recruited as exercise healthy women on regular basis (group A, n=10) and non-exercise idiopathic scoliosis women (group B, n=10). Data was collected by using a vicon motion capture system (MX-T40, UK). The pelvis, spine segments column and lower limbs analysiaed through the 3D kinematic angular ROM pattern. There were significant differences in the time-space variables, the rotation motion of knee joint in lower limbs and the pelvis variables; obliquity in side bending, inter/outer rotation in twisting during running leg movement. There were significant differences in the spinal column that is lower-lumbar, upper-lumbar, upper-thoracic, mid-upper thoracic, mid-lower thoracic, lower thoracic and cervical spine at inclination, lateral bending and twist rotation between group A and group B (<.05, <.01 and <.001). As a results, group B had more restrictive motion than group A in the spinal column and leg movement behaved like a 'shock absorber". And the number of asymmetry index (AI) showed that group B was much lager unbalance than group A. In conclusion, non-exercise group was known to much more influence the dynamic stability of equilibrium for bilateral balance. These finding suggested that dynamic stability aimed at increasing balance of the trunk ROM must involve methods and strategies intended to reduce left/right asymmetry and the exercise injury.

Particle Morphology Change and Different Experimental Condition Analysis during Composites Fabrication Process by Conventional Ball Mill with Discrete Element Method(DEM) Simulation (전동볼밀을 이용한 금속기반 복합재 제조공정에서 분쇄매체차이에 대한 입자형상변화와 DEM 시뮬레이션 해석)

  • Ichinkhorloo, Batchuluun;Bor, Amgalan;Uyanga, Batjargal;Lee, Jehyun;Choi, Heekyu
    • Korean Journal of Materials Research
    • /
    • v.26 no.11
    • /
    • pp.611-622
    • /
    • 2016
  • Particle morphology change and different experimental condition analysis during composite fabrication process by traditional ball milling with discrete element method (DEM) simulation were investigated. A simulation of the three dimensional motion of balls in a traditional ball mill for research on the grinding mechanism was carried out by DEM simulation. We studied the motion of the balls, the ball behavior energy and velocity; the forces acting on the balls were calculated using traditional ball milling as simulated by DEM. The effect of the operational variables such as the rotational speed, ball material and size on the flow velocity, collision force and total impact energy were analyzed. The results showed that increased rotation speed with interaction impact energy between balls and balls, balls and pots and walls and balls. The rotation speed increases with an increase of the impact energy. Experiments were conducted to quantify the grinding performance under the same conditions. Furthermore, the results showed that ball motion affects the particle morphology, which changed from irregular type to plate type with increasing rotation speed. The evolution was also found to depend on the impact energy increase of the grinding media. These findings are useful to understand and optimize the particle motion and grinding behavior of traditional ball mills.

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

  • Hwang, Ui-jae;Ha, Sung-min;Jeon, In-chul;Jung, Sung-hoon;Choi, Kyu-hwan;Kim, Su-jung;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.22 no.4
    • /
    • pp.62-70
    • /
    • 2015
  • The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester's hand over the subject's clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B's measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

The Effect of Myofacial Release and Transcutaneous Electrical Nerve Stimulation on the Range of Motion and Pain in Patient with Chronic Cervical Neck Pain (만성경부통증 환자에 대환 근막이완술과 경피신경 전기자극 치료가 치료기간에 따라 관절가동범위와 통증에 미치는 영향)

  • Seo, Hyun-Kyu;Gong, Won-Tae;Lee, Sang-Yong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.11 no.2
    • /
    • pp.1-12
    • /
    • 2005
  • The purpose of this study is compare the effects of two therapeutic processes-i) conservative Myofacial Release Technique along and ii) Transcutaneous Electrical Nerve stimuliation alone - on the increase in the range of motion(ROM) and on the decrease in patient's pain with chronic Neck pain. The subjects of the study were student with choronic neck pain in Daegu health university. Half of them (10) took conservative Myofacial Release Technique along and the others (10) took Transcutaneous Electrical Nerve stimuliation alone. I used 3D Motion analysis. The range of motion (ROM) in six areas-flexion, extension, left lateral flexion, right lateral flexion, left rotation, right rotation-to check the effectiveness of the two combinations of methods, measured pain with visual analogue scale (VAS) to see the effect on pain reduce. Assement was conducted to the groups before the treatment began and affer the four weeks treatment ended. This study shows that both groups demonstrated significant improvement in ROM increase and pain reduction. Flexion ROM increases were significant in MFR and TENS after treatment 2 weeks and 4 weeks. Extension ROM increases were significant in MFR and TENS after treatment 2 weeks. Right rotation ROM was no significant differences were found in MFR and TENS after treatment all weeks. Right lateral flexion ROM increases were significant in MFR and TENS after treatment 3 weeks. Left lateral flexion ROM increases were significant in MFR and TENS after treatment 1 weeks. But the others no significant differences were in MFR group and TENS group during 4 weeks.

  • PDF

A Kinetics Analysis of Tucked Backward Salto on the Balance Beam (평균대 제자리 무릎 구부려 뒤공중돌기 기술의 운동역학적 분석)

  • Kim, Kew-Wan;Ryu, Young;Jeon, Kyoung-Kyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.4
    • /
    • pp.395-404
    • /
    • 2012
  • This study was to perform the kinetic analysis of tucked backward salto on the balance beam. Eight women's gymnastics players(age: $15.88{\pm}2.45yrs$, career: $6.38{\pm}0.52yrs$, height: $152.38{\pm}7.35cm$, weight: $44.25{\pm}7.54kg$) of the I-region participated in this study. The kinematic variables were analyzed response time of motion, angle, velocity, acceleration and the kinetic variables were analyzed ground reaction force(GRF) of motion. For measure and analysis of kinematic and kinetic variables of this study, used to synchronized to 6 Eagle camera and 1 force plate, used to the Cortex(Ver. 1.0) for analyzed of variables. The results were as follows; To the kinematic variables of tucked backward salto on the balance beam, a time appeared longer landing than air rotation, changes of angle regulated segment of body smaller moment of inertia when air rotation, larger moment of inertia when releasing and landing. A velocity appeared fast motion when releasing and air rotation of body, but appeared more decelerations from landing and acceleration showed to be tended to velocity. A GRF appears jump more than twice the weight at the moment that showed the power of motion to all subject.

Effects of Thoracic Mobility Exercise on Cervicothoracic Function, Posture and Pain in Individuals With Mechanical Neck Pain (등뼈 가동성 운동이 기계적 목통증 환자의 목등뼈부 기능 수준과 자세, 통증 수준에 미치는 영향)

  • Lee, Hwa-jeong;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.42-56
    • /
    • 2019
  • Background: Individuals with mechanical neck pain show biomechanical and neurophysiological changes, including cervical spine muscle weakness. As a result of deep muscle weakness, it causes stability disability and reduced upper thoracic spine mobility, which finally leads to functional movement restriction such as limited range of motion and dysfunction. Recent studies have shown that thoracic spine manipulation and mobilization could reduce symptoms of mechanical neck pain in patients. Objects: The purpose of this study was to investigate the effects of thoracic mobility exercise on cervicothoracic function, posture feature, and pain intensity in individuals with mechanical neck pain. Methods: The study subjects were 26 persons who were randomly assigned to the experimental (with thoracic mobility exercise) and control groups (without thoracic mobility exercise), with 13 subjects in each group. The cervicothoracic function (neck functional disability level and cervicothoracic range of motion), posture feature, and pain rating (using a quadrupled visual analogue scale [QVAS]) were measured before, after 3 weeks, and after 6 weeks. Results: Statistically significant group-by-time interactions were found with repeated analyses of variance for the Korean neck disability index (KNDI), all cervical range of motion (CROM), all thoracic range of motion (TROM), cranial rotation angle, sagittal shoulder posture (SSP), and QVAS (p<.05). All groups showed significant improvements from all times in all the evaluated methods. The KNDI, CROM, TROM of left rotation, and SSP in the experimental group showed significant improvements after 3 weeks, and the TROM of the right rotation and QVAS in the experimental group showed significant improvements after 6 weeks when compared with the control group. Conclusion: Thoracic mobility exercise during 6 weeks might be effective intervention to improve the functional level, posture feature, and QVAS pain rating for managing individuals with mechanical neck pain.

Glenohumeral versus subacromial steroid injections for impingement syndrome with mild stiffness: a randomized controlled trial

  • Yong-Tae Kim;Tae-Yeong Kim;Jun-Beom Lee;Jung-Taek Hwang
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.390-396
    • /
    • 2023
  • Background: The subacromial (SA) space is a commonly used injection site for treatment of impingement syndrome. For shoulder stiffness, glenohumeral (GH) injections are commonly performed. However, in cases of impingement syndrome with mild shoulder stiffness, the optimal site of steroid injection has yet to be identified. Methods: This prospective, randomized study compared the short-term outcomes of ultrasound-guided GH and SA steroid injections in patients who were diagnosed with impingement syndrome and mild stiffness. Each group comprised 24 patients who received either a GH or SA injection of 40 mg of triamcinolone. Range of motion and clinical scores were assessed before and 3, 7, and 13 weeks after the injection. Results: GH and SA injections significantly improved the range of motion and clinical scores after 13 weeks of follow-up. Notably, targeting the GH joint resulted in an earlier gain of forward elevation, external rotation, and internal rotation in 3 weeks (P<0.001, P=0.012, and P=0.002, respectively) and of internal rotation and a Constant-Murley score in 7 weeks (P<0.001 and P=0.046). Subsequent measurements were similar between the groups and showed a steady improvement in all ranges of motion and clinical scores. Conclusions: GH injections may be more favorable than SA injections for treatment of impingement syndrome with mild stiffness, especially in improving the range of motion in the early period. However, the procedures showed similar outcomes after 3 months. Level of evidence: I.

Motion Estimation Using Feature Matching and Strongly Coupled Recurrent Module Fusion (특징정합과 순환적 모듈융합에 의한 움직임 추정)

  • 심동규;박래홍
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.12
    • /
    • pp.59-71
    • /
    • 1994
  • This paper proposes a motion estimation method in video sequences based on the feature based matching and anistropic propagation. It measures translation and rotation parameters using a relaxation scheme at feature points and object orinted anistropic propagation in continuous and discontinuous regions. Also an iterative improvement motion extimation based on the strongly coupled module fusion and adaptive smoothing is proposed. Computer simulation results show the effectiveness of the proposed algorithm.

  • PDF

Generating 3-D Models of Human Motions by Motion Capture

  • Yamaguchi, I.;Tou, K.;Tan, J.K.;Ishikawa, S.;Naito, T.;Yokota, M.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1629-1632
    • /
    • 2003
  • A technique is presented for generating a compound human motion from its primitive motions obtained by a motion capture system. Some human fundamental motions are modeled in a 3-D way and registered as primitive motions. Because the factorization method is used for the motion capture, calibration of video cameras and connection of the motion in the direction of time is both unnecessary. Employing these motions, various compound human motions are generated by connecting the motions after having applied rotation and parallel transformation to them. Linear interpolation is done at the discontinuous boundary between primitive motions and smooth connection is achieved. Experimental results show satisfactory performance of the proposed technique. The technique may contribute to producing various complicated human motions without much effort using a strict motion capture system.

  • PDF