• Title/Summary/Keyword: Rotation correction

Search Result 180, Processing Time 0.02 seconds

A Study of the Stability on Standing posture of Single leg in Yoga practicing (요가 수련을 통한 한발서기 자세의 안정화 연구)

  • Yoo, Sil;Hong, Su-yeon;Yoo, Sun-sik
    • 한국체육학회지인문사회과학편
    • /
    • v.55 no.6
    • /
    • pp.749-757
    • /
    • 2016
  • The purpose of this study was to investigate the effect of stability on one leg standing posture in yoga practice. Thirteen women college student who have never done yoga participated in this study. In order to collect data before and after yoga practicing for two years, we were used 3D motion capture system and electromyography. The results were as follows. First, ranges of motions for Y axis of left knee joint and X axis of right ankle joint were significantly different in dancer posture(p<.05), and then X axis of right ankle and Y axis of left ankle joint were significantly different in tree posture of pre and post training. Second, the planar alignment angle of trunk-pelvis was not significant difference in dancer and tree posture. Third, CoM-distances of Y, Z directions were significant difference in the tree posture(p<.05). Fourth, Muscle activities of both rectus abdominis, erector spinae and left quadriceps were significant difference in tree posture(p<.05). These findings suggested that yoga training played important roles in stable postures as results of decreasing rotation ankle joint and movement of CoM and enforcing core muscles. This study provides evidence for effectiveness of the stability on standing posture and can get a great effect on posture correction by means of yoga training. Hereafter, study on alignment angle, which is a measurement of postural stabilization will be needed by future yoga training.

A Fluid Analysis Study on Centrifugal Pump Performance Improvement by Impeller Modification (원심펌프 회전차 Modification시 성능개선에 관한 유동해석 연구)

  • Lee, A-Yeong;Jang, Hyun-Jun;Lee, Jin-Woo;Cho, Won-Jeong
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • Centrifugal pump is a facility that transfers energy to fluid through centrifugal force, which is usually generated by rotating the impeller at high speed, and is a major process facility used in many LNG production bases such as vaporization seawater pump, industrial water and fire extinguishing pump using seawater. to be. Currently, pumps in LNG plant sites are subject to operating conditions that vary depending on the amount of supply desired by the customer for a long period of time. Pumps in particular occupy a large part of the consumption strategy at the plant site, and if the optimum operation condition is not available, it can incur enormous energy loss in long term plant operation. In order to solve this problem, it is necessary to identify the performance deterioration factor through the flow analysis and the result analysis according to the fluctuations of the pump's operating conditions and to determine the optimal operation efficiency. In order to evaluate operation efficiency through experimental techniques, considerable time and cost are incurred, such as on-site operating conditions and manufacturing of experimental equipment. If the performance of the pump is not suitable for the site, and the performance of the pump needs to be reduced, a method of changing the rotation speed or using a special liquid containing high viscosity or solids is used. Especially, in order to prevent disruptions in the operation of LNG production bases, a technology is required to satisfy the required performance conditions by processing the existing impeller of the pump within a short time. Therefore, in this study, the rotation difference of the pump was applied to the ANSYS CFX program by applying the modified 3D modeling shape. In addition, the results obtained from the flow analysis and the curve fitting toolbox of the MATLAB program were analyzed numerically to verify the outer diameter correction theory.

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

Quantification of Myocardial Blood flow using Dynamic N-13 Ammonia PET and factor Analysis (N-13 암모니아 PET 동적영상과 인자분석을 이용한 심근 혈류량 정량화)

  • Choi, Yong;Kim, Joon-Young;Im, Ki-Chun;Kim, Jong-Ho;Woo, Sang-Keun;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.316-326
    • /
    • 1999
  • Purpose: We evaluated the feasibility of extracting pure left ventricular blood pool and myocardial time-activity curves (TACs) and of generating factor images from human dynamic N-13 ammonia PET using factor analysis. The myocardial blood flow (MBF) estimates obtained with factor analysis were compared with those obtained with the user drawn region-of-interest (ROI) method. Materials and Methods: Stress and rest N-13 ammonia cardiac PET imaging was acquired for 23 min in 5 patients with coronary artery disease using GE Advance tomograph. Factor analysis generated physiological TACs and factor images using the normalized TACs from each dixel. Four steps were involved in this algorithm: (a) data preprocessing; (b) principal component analysis; (c) oblique rotation with positivity constraints; (d) factor image computation. Area under curves and MBF estimated using the two compartment N-13 ammonia model were used to validate the accuracy of the factor analysis generated physiological TACs. The MBF estimated by factor analysis was compared to the values estimated by using the ROI method. Results: MBF values obtained by factor analysis were linearly correlated with MBF obtained by the ROI method (slope = 0.84, r = 0.91), Left ventricular blood pool TACs obtained by the two methods agreed well (Area under curve ratio: 1.02 ($0{\sim}1min$), 0.98 ($0{\sim}2min$), 0.86 ($1{\sim}2min$)). Conclusion: The results of this study demonstrates that MBF can be measured accurately and noninvasively with dynamic N-13 ammonia PET imaging and factor analysis. This method is simple and accurate, and can measure MBF without blood sampling, ROI definition or spillover correction.

  • PDF

A STUDY ON THE EFFECT OF CHINCAP IN JUVENILE SKELETAL GLASS III MALOCCLUSION (유년기 III급 부정교합자에서 이모장치의 치료 효과에 관한 연구)

  • Nahm, Dong-Seok;Suhr, Chung-Hoon;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.517-531
    • /
    • 1998
  • The purpose of this study was to investigate the changes in the craniofacial skeleton subsequent to chincap therapy in the juvenile skeletal Class III malocclusion with more appropriate control samples. The experimental group consisted of 29 Korean children(14 males, 15 females) who had skeletal Class III malocclusion with prognathic mandible and were undergone chincap thorny from the beginning of treatment. The control group was composed of 21 Korean children(10 males, 11 females) who had no orthodontic treatment, but with similar skeletal discrepancies to experimental group. Lateral cephalometric radiographs at the age of 7, and 2 years later were analyized and compared with student's t-test(p<0.05). The results of this study were as follows; 1. The control group without chincap therapy had not shown any improvement of the skeletal discrepancies, but had grown to be much severe. This means that the untreated Class III patient with prognathic mandible would not be corrected by growth. For the experimental group with chincap therapy, the anterior-posterior skeletal discrepancies and mandibular prognathism were both improved. 2. Neither significant restraint nor acceleration of growth was found in the cranial base and maxilla by chincap treatment. 3. The inhibition of mandibular growth could not be accepted, but the changes of the direction of growth and morphological changes were found. 4. Vertical growth tendency was increased with chincap therapy. 5. When Putting together the results of the analyses , it seems to be the rotation and displacement of the mandible that the major treatment effects of chincap we. The changes of the direction of growth and the morphological changes also seems to contibute to the treatment effect partly. In summary, the chincap doesn't restrain the mandibular growth. But, it is considered as a useful treatment modality for correction of skeletal discrepancies and reduction of mandibular prognathism in growing Class III patients with madibular prognathism.

  • PDF

Skeletal relapse and dental change during intermaxillary fixation after mandibular setback (외과적 하악 후퇴술 후 악간고정기간 중의 골격성 재발과 치열의 변화)

  • Chang, Chong-On
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.457-466
    • /
    • 1999
  • It has been reported that skeletal relapse and dental change after mandibular setback do occur not only after intermaxillary fixation(IMF) removal but also during IMF The side effects of skeletal relapse during IMF have clinical importance because they can cause many Postoperative orthodontic Problems. Generally, the Prevention of solid union between segments, compensatory tooth movement, anterior openbite, etc. have been cited as the side effects of jaw displacement. The purpose of this study was to evaluate the skeletal relapse and dental change during IMF. The material consisted of 28 patients who were treated by BSSRO(bilateral sagittal split ramus osteotomy), wire osteosynthesis, IMF for correction of mandibular prognathism. Through cephalometric analysis, the amount and direction of surgical movement, skeletal relapse and dental change during IMF were measured. The correlation between surgical movement and skeletal relapse, between skeletal relapse and dental changes were evaluated. The following conclusions were obtained; 1. Distal segment was repositioned backward and upward, proximal segment showed clockwise rotation during surgery. 2. During ]m, anterior portion of distal segment was displaced backward and posterior portion was displaced upward. Proximal segment was displaced upward with forward movement of p-Go(gonion of proximal segment). Backward surgical movement of p-GO was significantly correlated with forward displacement of p-Go. 3. Overjet and overbite were not changed during IMF. The compensatory tooth movements during IMF were characterized by retroclination of upper incisors md retroclination, extrusion of lower incisors. These compensatory tooth movements had statistically significant correlation with upward displacement of d-Go (gonion of distal segment).

  • PDF

Motion Reduction Activities in Patients undergoing Myocardial Perfusion SPECT with the Discovery NM 530c(D530c) (Discovery NM 530c(D530c)에서 촬영한 심근관류 SPECT 환자의 움직임 감소활동을 위한 연구)

  • Lee, Dong Hun;Choi, Woo Jun;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.80-85
    • /
    • 2017
  • Purpose The D530c have cadmium zinc telluride(CZT) detectors that are arranged focus on the heart. This structural characteristic allows for quicker imaging without rotation, but this is sensitive to patient movement and can affect the test results. The aim of this study is to optimize the image quality by reducing patient movement during the examination. Materials and Methods We analyzed the patients' movements, and performed various activities such as provided patient education about correct breathing techniques and avoiding patient movements, and created breathing correction tools to minimize patient movement during exam. The 70 patients who underwent myocardial perfusion SPECT with D530c in November 2016 were categorized as the group before the corrective steps. Another 70 patients who underwent the procedure with D530c from February 14, 2017 to February 21, 2017 were categorized as the improvement group. Images acquired during stress and at rest were compared and analyzed by measuring the durations of heart movements over certain distances (4 mm, 8 mm, 12 mm, or more) noted on the x-, y-, and zaxes. Results After the activities, the durations of heart movements decreased in the images acquired both under stress and at rest. In particular, there were no large motions greater than 12 mm recorded in the stress images after the improvement. There was a significant difference (p<0.005) in the 4-mm and 8-mm fluctuations on the X-axis and the 8-mm fluctuations on the Z axis in the stress images, but there was no significant difference (p>0.005) in the other stress and rest intervals. Conclusion The decrease in the time of motion occurrence due to the 4 mm fluctuation distance that can occur through breathing can be understood as a result of the breathing being corrected through training and motion prevention tools. It is expected that the image quality will be improved by reducing the occurrence time according to the variation distance of 8 mm or 12 mm, which is expected as the actual movement of the patient other than the breathing.

  • PDF

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.