• Title/Summary/Keyword: Rotating System

Search Result 1,765, Processing Time 0.028 seconds

Optimal Design of Stiffness of Torsion Spring Hinge Considering the Deployment Performance of Large Scale SAR Antenna (전개성능을 고려한 대형 전개형 SAR 안테나의 회전스프링 힌지의 강성 최적설계)

  • Kim, Dong-Yeon;Lim, Jae Hyuk;Jang, Tae-Seong;Cha, Won Ho;Lee, So-Jeong;Oh, Hyun-Ung;Kim, Kyung-Won
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.3
    • /
    • pp.78-86
    • /
    • 2019
  • This paper describes the stiffness optimization of the torsion spring hinge of the large SAR antenna considering the deployment performance. A large SAR antenna is folded in a launch environment and then unfolded when performing a mission in orbit. Under these conditions, it is very important to find the proper stiffness of the torsion spring hinge so that the antenna panels can be deployed with minimal impact in a given time. If the torsion spring stiffness is high, a large impact load at the time of full deployment damages the structure. If it is weak, it cannot guarantee full deployment due to the deployment resistance. A multi-body dynamics analysis model was developed to solve this problem using RecurDyn and the development performance were predicted in terms of: development time, latching force, and torque margin through deployment analysis. In order to find the optimum torsion spring stiffness, the deployment performance was approximated by the response surface method (RSM) and the optimal design was performed to derive the appropriate stiffness value of the rotating springs.

Rotordynamic Performance Measurements and Predictions of a FCEV Air Compressor Supported on Gas Foil Bearings (가스 포일 베어링으로 지지되는 연료전지 전기자동차용 공기압축기의 회전체동역학적 성능 측정 및 예측)

  • Hwang, Sung Ho;Moon, Chang Gook;Kim, Tae Ho;Lee, Jongsung;Cho, Kyung Seok;Ha, Kyoung-Ku;Lee, Chang Ha
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.44-51
    • /
    • 2019
  • The paper presents the rotordynamic performance measurements and model predictions of a fuel cell electric vehicle (FCEV) air compressor supported on gas foil bearings (GFBs). The rotor has an impeller on one end and a thrust runner on the other end. The front (impeller side) and rear (thrust side) gas foil journal bearings (GFJBs) are located between the impeller and thrust runner to support the radial loads, and a pair of gas foil thrust bearings are located on both sides of the thrust runner to support the axial loads. The test GFJBs have a partial arc shim foil installed between the top foil and bump strip layers to enhance hydrodynamic pressure generation. During the rotordynamic performance tests, two sets of orthogonally installed eddy-current displacement sensors measure the rotor radial motions at the rotor impeller and thrust ends. A series of speed-up and coast-down tests to 100k rpm demonstrates the dominant synchronous (1X) rotor responses to imbalance masses without noticeable subsynchronous motions, which indicates a rotordynamically stable rotor-GFB system. Finite element analysis of the rotor determines the rotor free-free (bending) natural modes and frequencies well beyond the maximum rotating frequency. The predicted damped natural frequencies and damping ratios of the rotor-GFB system reveal rotordynamic stability over the speeds of interest. The imbalance response predictions show that the predicted critical speeds and rotor amplitudes strongly agree with the test measurements, thus validating the developed rotordynamic model.

A Study on Machine Learning of the Drivetrain Simulation Model for Development of Wind Turbine Digital Twin (풍력발전기 디지털트윈 개발을 위한 드라이브트레인 시뮬레이션 모델의 기계학습 연구)

  • Yonadan Choi;Tag Gon Kim
    • Journal of the Korea Society for Simulation
    • /
    • v.32 no.3
    • /
    • pp.33-41
    • /
    • 2023
  • As carbon-free has been getting interest, renewable energy sources have been increasing. However, renewable energy is intermittent and variable so it is difficult to predict the produced electrical energy from a renewable energy source. In this study, digital-twin concept is applied to solve difficulties in predicting electrical energy from a renewable energy source. Considering that rotation of wind turbine has high correlation with produced electrical energy, a model which simulates rotation in the drivetrain of a wind turbine is developed. The base of a drivetrain simulation model is set with well-known state equation in mechanical engineering, which simulates the rotating system. Simulation based machine learning is conducted to get unknown parameters which are not provided by manufacturer. The simulation is repeated and parameters in simulation model are corrected after each simulation by optimization algorithm. The trained simulation model is validated with 27 real wind turbine operation data set. The simulation model shows 4.41% error in average compared to real wind turbine operation data set. Finally, it is assessed that the drivetrain simulation model represents the real wind turbine drivetrain system well. It is expected that wind-energy-prediction accuracy would be improved as wind turbine digital twin including the developed drivetrain simulation model is applied.

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

A Study on Mobile Antenna System Design with Tri-band Operation for Broadband Satellite Communications and DBS Reception (광대역 위성 통신/방송용 삼중 대역 이동형 안테나 시스템 설계에 관한 연구)

  • Eom Soon-Young;Jung Young-Bae;Son Seong-Ho;Yun Jae-Seung;Jeon Soon-Ick
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.5 s.108
    • /
    • pp.461-475
    • /
    • 2006
  • In this paper, it is described about the tri-band mobile antenna system design to provide broadband multimedia and direct broadcasting services using goo-stationary Koreasat 3, simultaneously operated in Ka/K/Ku band. The radiating part of the antenna system with a fan beam characteristic in the elevation plane is composed of the quasi-offset dual shaped reflector and the tri-band feeder. The tri-band feeder is also composed of the Ka/K dual band feeder with the protruding dielectric rod, the circular polarizer, the ortho-mode transducer and the circular-polarized Ku band feed array. Especially, the Ka/K dual band circular polarizer was realized firstly using the comb-type structure. For fast satellite-tracking on the movement, the Ku band feed array has the structure of the $2{\times}2$ active phased array which can make electrical beams. And, the circular-polarized characteristic in the feed array was improved by $90^{\circ}$ rotating arrangement of four radiating elements polarized circularly by a $90^{\circ}$ hybrid coupler, respectively. Four beam forming channels to make electrical beams at Ku band are divided into the main beam channel and the tracking beam channel in the output, and noise temperature characteristics of each channel were analyzed on the basis of the contributions of internal sub_units. From the fabricated antenna system, the output power at $P_{1dBc}$ of Ka_Tx channel was measured more than 34.1 dBm and the measured noise figures of K/Ku_Rx channels were less than 2.4 dB and 1.5 dB, respectively, over the operating band. The radiation patterns with co- and cross-polarization in the tri-band were measured using a near-field measurement in the anechoic chamber. Especially, Ku radiation patterns were measured after correcting each initial phase of active channels with partial radiation patterns obtained from the independent excitation of each channel. The antenna gains measured in Ka/K/Ku band of the antenna system were more than 39.6 dBi, 37.5 dBi, 29.6 dBi, respectively. And, the antenna system showed good system performances such as Ka_Tx EIRP more than 43.7 dBW and K/Ku_Rx G/T more than 13.2 dB/K and 7.12 dB/K, respectively.

Culture of the Olive Flounder (Paralichthys olivaceus) in a Semi-closed Recirculating Seawater System (반폐쇄식 순환여과 사육시스템에서의 넙치 (Paralichthys olivaceus) 양식)

  • CHANG Young Jin;KIM Seung Hyern;YANG Han Soeb
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.4
    • /
    • pp.457-468
    • /
    • 1995
  • In order to develop a more practical culture system from the present running seawater tank system, two experiments of environmental factors, growth, survival rate and rearing density of olive flounder (Paralichthys olivaceus) were carried out for two consecutive years. Two groups of fish in initially averaging 7.5cm of total length, and 3.4g of body weight (EXP. I) and 5.0cm and 1.8g (EXP. II) were reared in the semi-closed recirculating seawater system equipped with the rotating biological contactors with the commercial culture scale. The dissolved inorganic nitrogen concentrations is EXP. I ranged 0,247-0.512 ppm of $NH_4-N$ (0.010-0.043 ppm of$NO_2-N$, and 0.108-0.342 ppm of $NO_3-N$, and those in EXP. II were 0.091-0.715 ppm, 0.002-0.045 ppm, and 0.007-0.277 ppm, respectively. Daily feeding rates of the fish were $0.67-2.41\%$ in EXP. I and $0.69-2.22\%$ in EXP_ II, and teed efficiency were $34.8-59.8\%\;and\;40.5-88.4\%$ in EXP. I and II, respectively. The average total ten說h and body weight were 40.0-42.8cm and 695.0-852.69g after 340 days culture in EXP. I, and 36.7-39.7cm and 552.4-706.4 g after 365 days culture in EXP. II, respectively. Survival rates of the fish at the end of EXP. I and II were $92.0\%\;and\;96.0\%,$ respectively. The ratio to body surface area of non-ocular side in all fish to bottom area of rearing tank, so-called covering rate, was used as an indicator of rearing density. The highest cowering rate and weight density of fish per $m^2$ of rearing tank at the end of experimental period were 2.2 and 34.1kg in EXP. I, and 2.6 and 36.3kg in EXP. II, respectively. For the commercial culture of olive flounder, the semi-closed recirculating seawater system was found to be more effective than the running seawater tank system in aspect to the fish productivity and protection of marine environment.

  • PDF

Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator (Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Kim, Jin-Su;Lee, Byeong-Il;Kim, Soo-Mee;Choung, In-Soon;Kim, Yu-Kyeong;Lee, Won-Woo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.445-455
    • /
    • 2005
  • Purpose: We developed an animal SPECT system using clinical Philips ARGUS scintillation camera and pinhole collimator with specially manufactured small apertures. In this study, we evaluated the physical characteristics of this system and biological feasibility for animal experiments. Materials and Methods: Rotating station for small animals using a step motor and operating software were developed. Pinhole inserts with small apertures (diameter of 0.5, 1.0, and 2.0 mm) were manufactured and physical parameters including planar spatial resolution and sensitivity and reconstructed resolution were measured for some apertures. In order to measure the size of the usable field of view according to the distance from the focal point, manufactured multiple line sources separated with the same distance were scanned and numbers of lines within the field of view were counted. Using a Tc-99m line source with 0.5 mm diameter and 12 mm length placed in the exact center of field of view, planar spatial resolution according to the distance was measured. Calibration factor to obtain FWHM values in 'mm' unit was calculated from the planar image of two separated line sources. Te-99m point source with i mm diameter was used for the measurement of system sensitivity. In addition, SPECT data of micro phantom with cold and hot line inserts and rat brain after intravenous injection of [I-123]FP-CIT were acquired and reconstructed using filtered back protection reconstruction algorithm for pinhole collimator. Results: Size of usable field of view was proportional to the distance from the focal point and their relationship could be fitted into a linear equation (y=1.4x+0.5, x: distance). System sensitivity and planar spatial resolution at 3 cm measured using 1.0 mm aperture was 71 cps/MBq and 1.24 mm, respectively. In the SPECT image of rat brain with [I-123]FP-CIT acquired using 1.0 mm aperture, the distribution of dopamine transporter in the striatum was well identified in each hemisphere. Conclusion: We verified that this new animal SPECT system with the Phlilps ARGUS scanner and small apertures had sufficient performance for small animal imaging.

A Study on Hoslital Nurses' Preferred Duty Shift and Duty Hours (병원 간호사의 선호근무시간대에 관한 연구)

  • Lee, Gyeong-Sik;Jeong, Geum-Hui
    • The Korean Nurse
    • /
    • v.36 no.1
    • /
    • pp.77-96
    • /
    • 1997
  • The duty shifts of hospital nurses not only affect nurses' physical and mental health but also present various personnel management problems which often result in high turnover rates. In this context a study was carried out from October to November 1995 for a period of two months to find out the status of hospital nurses' duty shift patterns, and preferred duty hours and fixed duty shifts. The study population was 867 RNs working in five general hospitals located in Seoul and its vicinity. The questionnaire developed by the writer was used for data collection. The response rate was 85.9 percent or 745 returns. The SAS program was used for data analysis with the computation of frequencies, percentages and Chi square test. The findings of the study are as follows: 1. General characteristics of the study population: 56 percent of respondents was (25 years group and 76.5 percent were "single": the predominant proportion of respondents was junior nursing college graduates(92.2%) and have less than 5 years nursing experience in hospitals(65.5%). For their future working plan in nursing profession, nearly 50% responded as uncertain The reasons given for their career plan was predominantly 'personal growth and development' rather than financial reasons. 2. The interval for rotations of duty stations was found to be mostly irregular(56.4%) while others reported as weekly(16.1%), monthly(12.9%), and fixed terms(4.6%). 3. The main problems related to duty shifts particularly the evening and night duty nurses reported were "not enough time for the family, " "afraid of security problems after the work when returning home late at night." and "lack of leisure time". "problems in physical and physiological adjustment." "problems in family life." "lack of time for interactions with fellow nurses" etc. 4. The forty percent of respondents reported to have '1-2 times' of duty shift rotations while all others reported that '0 time'. '2-3 times'. 'more than 3 times' etc. which suggest the irregularity in duty shift rotations. 5. The majority(62.8%) of study population found to favor the rotating system of duty stations. The reasons for favoring the rotation system were: the opportunity for "learning new things and personal development." "better human relations are possible. "better understanding in various duty stations." "changes in monotonous routine job" etc. The proportion of those disfavor the rotating 'system was 34.7 percent. giving the reasons of"it impedes development of specialization." "poor job performances." "stress factors" etc. Furthermore. respondents made the following comments in relation to the rotation of duty stations: the nurses should be given the opportunity to participate in the. decision making process: personal interest and aptitudes should be considered: regular intervals for the rotations or it should be planned in advance. etc. 6. For the future career plan. the older. married group with longer nursing experiences appeared to think the nursing as their lifetime career more likely than the younger. single group with shorter nursing experiences ($x^2=61.19.{\;}p=.000;{\;}x^2=41.55.{\;}p=.000$). The reason given for their future career plan regardless of length of future service, was predominantly "personal growth and development" rather than financial reasons. For further analysis, the group those with the shorter career plan appeared to claim "financial reasons" for their future career more readily than the group who consider the nursing job as their lifetime career$(x^2$= 11.73, p=.003) did. This finding suggests the need for careful .considerations in personnel management of nursing administration particularly when dealing with the nurses' career development. The majority of respondents preferred the fixed day shift. However, further analysis of those preferred evening shift by age and civil status, "< 25 years group"(15.1%) and "single group"(13.2) were more likely to favor the fixed evening shift than > 25 years(6.4%) and married(4.8%)groups. This differences were statistically significant ($x^2=14.54, {\;}p=.000;{\;}x^2=8.75, {\;}p=.003$). 7. A great majority of respondents(86.9% or n=647) found to prefer the day shifts. When the four different types of duty shifts(Types A. B. C, D) were presented, 55.0 percent of total respondents preferred the A type or the existing one followed by D type(22.7%). B type(12.4%) and C type(8.2%). 8. When the condition of monetary incentives for the evening(20% of salary) and night shifts(40% of. salary) of the existing duty type was presented. again the day shift appeared to be the most preferred one although the rate was slightly lower(66.4% against 86.9%). In the case of evening shift, with the same incentive, the preference rates for evening and night shifts increased from 11.0 to 22.4 percent and from 0.5 to 3.0 percent respectively. When the age variable was controlled. < 25 yrs group showed higher rates(31.6%. 4.8%) than those of > 25 yrs group(15.5%. 1.3%) respectively preferring the evening and night shifts(p=.000). The civil status also seemed to operate on the preferences of the duty shifts as the single group showed lower rate(69.0%) for day duty against 83. 6% of the married group. and higher rates for evening and night duties(27.2%. 15.1%) respectively against those of the married group(3.8%. 1.8%) while a higher proportion of the married group(83. 6%) preferred the day duties than the single group(69.0%). These differences were found to be statistically all significant(p=.001). 9. The findings on preferences of three different types of fixed duty hours namely, B, C. and D(with additional monetary incentives) are as follows in order of preference: B type(12hrs a day, 3days a wk): day shift(64.1%), evening shift(26.1%). night shift(6.5%) C type(12hrs a day. 4days a wk) : evening shift(49.2%). day shift(32.8%), night shift(11.5%) D type(10hrs a day. 4days a wk): showed the similar trend as B type. The findings of higher preferences on the evening and night duties when the incentives are given. as shown above, suggest the need for the introductions of different patterns of duty hours and incentive measures in order to overcome the difficulties in rostering the nursing duties. However, the interpretation of the above data, particularly the C type, needs cautions as the total number of respondents is very small(n=61). It requires further in-depth study. In conclusion. it seemed to suggest that the patterns of nurses duty hours and shifts in the most hospitals in the country have neither been tried for different duty types nor been flexible. The stereotype rostering system of three shifts and insensitiveness for personal life aspect of nurses seemed to be prevailing. This study seems to support that irregular and frequent rotations of duty shifts may be contributing factors for most nurses' maladjustment problems in physical and mental health. personal and family life which eventually may result in high turnover rates. In order to overcome the increasing problems in personnel management of hospital nurses particularly in rostering of evening and night duty shifts, which may related to eventual high turnover rates, the findings of this study strongly suggest the need for an introduction of new rostering systems including fixed duties and appropriate incentive measures for evenings and nights which the most nurses want to avoid, In considering the nursing care of inpatients is the round-the clock business. the practice of the nursing duty shift system is inevitable. In this context, based on the findings of this study. the following are recommended: 1. The further in-depth studies on duty shifts and hours need to be undertaken for the development of appropriate and effective rostering systems for hospital nurses. 2. An introduction of appropriate incentive measures for evening and night duty shifts along with organizational considerations such as the trials for preferred duty time bands, duty hours, and fixed duty shifts should be considered if good quality of care for the patients be maintained for the round the clock. This may require an initiation of systematic research and development activities in the field of hospital nursing administration as a part of permanent system in the hospital. 3. Planned and regular intervals, orientation and training, and professional and personal growth should be considered for the rotation of different duty stations or units. 4. In considering the higher degree of preferences in the duty type of "10hours a day, 4days a week" shown in this study, it would be worthwhile to undertake the R&D type studies in large hospital settings.

  • PDF

Stability of the growth process at pulling large alkali halide single crystals

  • V.I. Goriletsky;S.K. Bondarenko;M.M. Smirnov;V.I. Sumin;K.V. Shakhova;V.S. Suzdal;V.A. Kuznetzov
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.1
    • /
    • pp.5-14
    • /
    • 2003
  • Principles of a novel pulse growing method are described. The method realized in the crystal growing on a seed from melts under raw melt feeding provided a more reliable control of the crystallization process when producing large alkali halide crystals. The slow natural convection of the melt in the crucible at a constant melt level is intensified by rotating the crucible, while the crystal rotation favors a more symmetrical distribution of thermal stresses over the crystal cross-section. Optimum rotation parameters for the crucible and crystal have been determined. The spatial position oi the solid/liquid phase interface relatively to the melt surface, heaters and the crucible elements are considered. Basing on that consideration, a novel criterion is stated, that is, the immersion extent of the crystallization front (CF) convex toward the melt. When the crystal grows at a <> CF immersion, the raised CF may tear off from the melt partially or completely due to its weight. This results in avoid formation in the crystal. Experimental data on the radial crystal growth speed are discussed. This speed defines the formation of a gas phase layer at the crystal surface. The layer thickness il a function of time a temperature at specific values of pressure in the furnace and the free melt surface dimensions in the gap between the crystal and crucible wall. Analytical expressions have been derived for the impurity component mass transfer at the steady-state growth stage describing two independent processes, the impurity mass transfer along the <> path and its transit along the <> one. The heater (and thus the melt) temperature variation is inherent in any control system. It has been shown that when random temperature changes occur causing its lowering at a rate exceeding $0.5^{\circ}C/min$, a kind of the CF decoration by foreign impurities or by gas bubbles takes place. Short-term temperature changes at one heater or both result in local (i.e., at the front) redistribution of the preset axial growth speed.

Improvement of Katsuobushi smoking machine for the reduction of benzo(a)pyrene (가쓰오부시 훈연기 개선 및 벤조피렌 저감화)

  • Hong, Ju Hee;Hwang, Sang Min;Lee, Seung Ju
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.162-167
    • /
    • 2017
  • A Katsuobushi smoking machine was developed and evaluated to determine its benzo(a)pyrene reducing effect. The machine was equipped with two heaters for smoking and chamber heating. The smoke-generating system was equipped with a cadmium sulfide (CdS) smoke sensor, an on/off controller, and a rotating feeder with a smoke inlet. Raw bonito was steamed and then smoked under three smoke levels. After smoking at $45^{\circ}C$ for 108 h, the benzo(a)pyrene concentrations were 5.87, 7.83, and $11.41{\mu}g/kg$ at the low, middle, and high smoke levels, respectively. The benzo(a)pyrene concentrations after low-level smoking at 45, 65, and $85^{\circ}C$ for 108 h were 5.87, 4.82, and $3.27{\mu}g/kg$, respectively. Accordingly, the optimal conditions for benzo(a)pyrene reduction were a lower smoke level and higher smoking temperature. These optimal smoking conditions can be implemented with the newly developed machine, but is not possible using a conventional Katsuobushi smoking machine.