• Title/Summary/Keyword: Root Mean Square image(RMS)

Search Result 40, Processing Time 0.031 seconds

Estimation of Polarization Ratio for Sea Surface Wind Retrieval from SIR-C SAR Data

  • Kim, Tae-Sung;Park, Kyung-Ae
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.6
    • /
    • pp.729-741
    • /
    • 2011
  • Wind speeds have long been estimated from C-band VV-polarized SAR data by using the CMOD algorithms such as CMOD4, CMOD5, and CMOD_IFR2. Some SAR data with HH-polarization without any observations in VV-polarization mode should be converted to VV-polarized value in order to use the previous algorithms based on VV-polarized observation. To satisfy the necessity of polarization ratio (PR) for the conversion, we retrieved the conversion parameter from full-polarized SIR-C SAR image off the east coast of Korea. The polarization ratio for SIR-C SAR data was estimated to 0.47. To assess the accuracy of the polarization ratio coefficient, pseudo VV-polarized normalized radar cross section (NRCS) values were calculated and compared with the original VV-polarized ones. As a result, the estimated psudo values showed a good agreement with the original VV-polarized data with an root mean square error by 0.99 dB. We applied the psudo NRCS to the estimation of wind speeds based on the CMOD wind models. Comparison of the retrieved wind field with the ECMWF and NCEP/NCAR reanalysis wind data showed relatively small rms errors of 1.88 and 1.91 m/s, respectively. SIR-C HH-polarized SAR wind retrievals met the requirement of the scatterometer winds in overall. However, the polarization ratio coefficient revealed dependence on NRCS value, wind speed, and incident angle.

A Study on the Injection Characteristics of a Piezo Injector for Controlling Accurate Multiple Injection (커먼레일 타입 피에조 인젝터의 정밀 다단분사 제어를 위한 분사특성 연구)

  • Park, Heebum;Kim, Hyungik;Park, Sangki;Lee, Kihyung
    • Journal of ILASS-Korea
    • /
    • v.18 no.4
    • /
    • pp.176-181
    • /
    • 2013
  • In this study, injection quantity, rate and spray image of multiple injections which are important design parameters for a piezo type injector have been investigated. Interval of injections and a number of injections in multiple injection strategy has been controlled to verify interaction of each injection. Spray characteristics of multiple injections have been researched through optical process with a high speed camera in a high pressure chamber. In addition, a method of RMS(Root Mean Square) process has been used for comprehending the distribution of injection easily. As a result, in case of piezo type injector, characteristics of injection quantity according to charging voltage and the difference of injection quantity between single and triple injection were confirmed. Also, injection rate for increasing injection duration was confirmed. And spray characteristics of multiple injections were improved; multiple injections were possible in a shorter time interval between each injection. With this study, a possibilities of more accurate multiple injection control would be expected.

Spray Behavior Characteristics of Injector Used for HC-DeNOx Catalyst System in the Transparent Exhaust Manifold (모사 배기관 내 HC-DeNOx 촉매용 인젝터의 분무 거동 특성)

  • Lee, Dong-Hoon;Oh, Jung-Mo;Jeong, Hae-Young;Lee, Ki-Hyung;Yeo, Kwon-Gu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.4
    • /
    • pp.54-60
    • /
    • 2007
  • A new method that optimizes a control of hydrocarbon (HC) addition to diesel exhaust gas for HC type DeNOx catalyst system has been developed. These catalysts are called as the HC-DeNOx catalyst in this paper. The system using HC-DeNOx catalyst requires a resonable quantity of hydrocarbons addition in the inlet gas of the catalyst, because the HC concentration in a diesel engine is so low that the HC is not sufficient for NOx conversion. Generally ambient temperature in the exhaust manifold is $250{\sim}350^{\circ}C$, so spray behavior in this case is different from that of any other condions. This research shows spray behavior of injected hydrocarbons in the transparent exhaust manifold.

The Spray Characteristics and Spray Behavior Characteristic in Exhaust Gas Flow of Urea Solution Injector (Urea 수용액 분사용 인젝터의 분무 특성과 배기관내 분무 거동 특성)

  • Oh, Jung-Mo;Han, Young-Deok;Kim, Ki-Bum;Lee, Ki-Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.999-1004
    • /
    • 2010
  • Recently, many technologies have been developed in order to satisfy stringent emission regulations. However, in the case of diesel engines, the stringent emission regulations with respect to NOx and PM have not yet been satisfied. A dramatic reduction in the NOx and PM emissions could be achieved by using after-treatment systems such as lean NOx trap (LNT) and urea-SCR systems. However, the high temperature in the exhaust pipe affects the spray behavior of the secondary injector, which is used for supplying the Urea-SCR. Because of this high temperature, it is difficult to achieve uniform distribution of the reducing agent in the manifold. In this paper, the characteristics of a urea-SCR injector used for injecting in the exhaust pipe are presented. The purpose of this study was to investigate the spray characteristics of the injector, such as the spray angle, injection quantity, and SMD. In addition, laser diagnostics and high-speed-camera images were used to analyze the injector spray characteristics and to present a distribution of reduction in the transparent manifold.

The Influence of the Front Surface Power and the Refraction Index on RMS Spot Diameter (전면 굴절력과 굴절률이 착락원의 크기에 미치는 영향)

  • Park, Seong-Jong;Shin, Cheol-Guen;Ju, Seok-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.57-63
    • /
    • 2003
  • To investigate the RMS SD(Root Mean Square Spot Diameter) in a back focal plane as the front surface power, the center thickness, and the refraction index vary, we use programs which are Cove V and LOSA 2.0, and consider a spectacle lens with back vertex power of -4.00D and diameter of 70 mm. We also consider the front surface power varied from 0.00 to 10.00D, the center thickness varied from 1.1 to 2.0 mm, and the indices which are $n_d$ = 1.498, 1.523, 1.586, and 1.660, respectively. As the front surface power increases the RMS SD in the back focal plane increase rapidly. When the refraction index increases, the RMS SD in the back focal plane decrease and the variation of RMS SD in the back focal plane decreases as the front surface power increases. When the center thickness of spectacle lens increases, the RMS SD in the back focal plane is constant and the edge thickness of that increases. We know from these results that the image in the back focal plane of a spherical spectacle lens improves as the front surface power increases and the refraction index decreases.

  • PDF

Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method (Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법)

  • Han, Yong-Hee;Kim, Tae-Hyung;Chun, Song-I;Kim, Dong-Hyeuk;Lee, Kwang-Sig;Eun, Choong-Ki;Jun, Jae-Ryang;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • Purpose : This study proposes the keyhole method in order to improve the time resolution of the proton resonance frequency(PRF) MR temperature monitoring technique. The values of Root Mean Square (RMS) error of measured temperature value and Signal-to-Noise Ratio(SNR) obtained from the keyhole and full phase encoded temperature images were compared. Materials and Methods : The PRF method combined with GRE sequence was used to get MR temperature images using a clinical 1.5T MR scanner. It was conducted on the tissue-mimic 2% agarose gel phantom and swine's hock tissue. A MR compatible coaxial slot antenna driven by microwave power generator at 2.45GHz was used to heat the object in the magnetic bore for 5 minutes followed by a sequential acquisition of MR raw data during 10 minutes of cooling period. The acquired raw data were transferred to PC after then the keyhole images were reconstructed by taking the central part of K-space data with 128, 64, 32 and 16 phase encoding lines while the remaining peripheral parts were taken from the 1st reference raw data. The RMS errors were compared with the 256 full encoded self-reference temperature image while the SNR values were compared with the zero filling images. Results : As phase encoding number at the center part on the keyhole temperature images decreased to 128, 64, 32 and 16, the RMS errors of the measured temperature increased to 0.538, 0.712, 0.768 and 0.845$^{\circ}C$, meanwhile SNR values were maintained as the phase encoding number of keyhole part is reduced. Conclusion : This study shows that the keyhole technique is successfully applied to temperature monitoring procedure to increases the temporal resolution by standardizing the matrix size, thus maintained the SNR values. In future, it is expected to implement the MR real time thermal imaging using keyhole method which is able to reduce the scan time with minimal thermal variations.

  • PDF

Evaluation of the usefulness of IGRT(Image Guided Radiation Therapy) for markerless patients using SGPS(Surface-Guided Patient Setup) (표면유도환자셋업(Surface-Guided Patient Setup, SGPS)을 활용한 Markerless환자의 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)시 유용성 평가)

  • Lee, Kyeong-jae;Lee, Eung-man;Lee, Jeong-su;Kim, Da-yeon;Ko, Hyeon-jun;Choi, Shin-cheol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.109-116
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the usefulness of Surface-Guided Patient Setup by comparing the patient positioning accuracy when image-guided radiation therapy was used for Markerless patients(unmarked on the skin) using Surface-Guided Patient Setup and Marker patients(marked on the skin) using Laser-Based Patient Setup. Materials And Methods: The position error during IGRT was compared between a Markerless patient initially set up with SGPS using an optical surface scanning system using three cameras and a Marker patient initially set up with LBPS that aligns the laser with the marker drawn on the patient's skin. Both SGPS and LBPS were performed on 20 prostate cancer patients and 10 Stereotactic Radiation Surgery patients, respectively, and SGPS was performed on an additional 60 breast cancer patients. All were performed IGRT using CBCT or OBI. Position error of 6 degrees of freedom was obtained using Auto-Matching System, and comparison and analysis were performed using Offline-Review in the treatment planning system. Result: The difference between the root mean square (RMS) of SGPS and LBPS in prostate cancer patients was Vrt -0.02cm, Log -0.02cm, Lat 0.01cm, Pit -0.01°, Rol -0.01°, Rtn -0.01°, SRS patients was Vrt 0.02cm, Log -0.05cm, Lat 0.00cm, Pit -0.30°, Rol -0.15°, Rtn -0.33°. there was no significant difference between the two regions. According to the IGRT standard of breast cancer patients, RMS was Vrt 0.26, Log 0.21, Lat 0.15, Pit 0.81, Rol 0.49, Rtn 0.59. Conclusion:. As a result of this study, the position error value of SGPS compared to LBPS did not show a significant difference between prostate cancer patients and SRS patients. In the case of additionally performed SGPS breast cancer patients, the position error value was not large based on IGRT. Therefore, it is considered that it will be useful to replace LBPS with SGPS, which has the great advantage of not requiring patient skin marking..

Evaluating the Effects of Dose Rate on Dynamic Intensity-Modulated Radiation Therapy Quality Assurance

  • Kim, Kwon Hee;Back, Tae Seong;Chung, Eun Ji;Suh, Tae Suk;Sung, Wonmo
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.116-121
    • /
    • 2021
  • Purpose: To investigate the effects of dose rate on intensity-modulated radiation therapy (IMRT) quality assurance (QA). Methods: We performed gamma tests using portal dose image prediction and log files of a multileaf collimator. Thirty treatment plans were randomly selected for the IMRT QA plan, and three verification plans for each treatment plan were generated with different dose rates (200, 400, and 600 monitor units [MU]/min). These verification plans were delivered to an electronic portal imager attached to a Varian medical linear accelerator, which recorded and compared with the planned dose. Root-mean-square (RMS) error values of the log files were also compared. Results: With an increase in dose rate, the 2%/2-mm gamma passing rate decreased from 90.9% to 85.5%, indicating that a higher dose rate was associated with lower radiation delivery accuracy. Accordingly, the average RMS error value increased from 0.0170 to 0.0381 cm as dose rate increased. In contrast, the radiation delivery time reduced from 3.83 to 1.49 minutes as the dose rate increased from 200 to 600 MU/min. Conclusions: Our results indicated that radiation delivery accuracy was lower at higher dose rates; however, the accuracy was still clinically acceptable at dose rates of up to 600 MU/min.

Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image (디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.275-283
    • /
    • 2013
  • The patient radiation dose is different depending on selection of Ion chamber when taking Chest PA which using AEC. In this paper, we studied acquiring the best diagnostic images according to selection of Ion chamber on AEC mode as well as minimizing patient radiation dose. Experimental methods were selection of Ion chamber and change of sensitivity under the same conditions as Chest PA projection. At AEC mode, two upper ion chambers sensors and one lower ion chamber sensor were divided into 7 cases according to selection of on/off. after measuring five times respectively, we obtained average value and calculated exposure dose. Image assessment was done with measured Modulation Transfer Function, Peak Signal to Noise Ratio, Root Mean Square, Signal to Noise Ratio, Contrast to Noise Ratio, Mean to Standard deviation Ratio respectively. In exposure assessment results, selection of two upper chambers was the lowest. In resolution assessment results, image of two upper chambers had the second high spatial frequency at sensitivity at 625(High) was 1.343 lp/mm. RMS value of image selecting two upper chambers was low secondly. SNR, CNR, MSR were the high value secondly. As the sensitivity was increased, radiation dose was decreased but better image could be obtained on image quality. In order to obtain the best medical images while minimizing the dose, usage of two upper ion chambers is considered to be clinically useful at sensitivity 625(High).

A Study on the Characteristic and Droplet Uniformity of Spray Injection to Exhaust Gas Flow from Urea Solution Injector (Urea 수용액의 배기가스 유동장내 분무 특성과 분무 균일도에 관한 연구)

  • Oh, Jung-Mo;Cha, Won-Sim;Kim, Ki-Bum;Lee, Jin-Ha;Lee, Ki-Hyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.3
    • /
    • pp.83-89
    • /
    • 2011
  • Diesel engines can produce higher fuel efficiency and lower $CO_2$ emission, they are subject to ever more stringent emission regulation. However, there are two major emission concerns fo diesel engines like such as particulate matter (PM) and nitrogen oxides (NOx). Moreover, it is not easy to satisfy the regulations on the emission of NOx and PM, which are getting more strengthened. One of the solutions is to apply the new combustion concept using multistage injection such as HCCI and PCCI. The other solution is to apply after-treatment systems. For example, lean NOx trap catalyst, Urea-SCR and others have various advantages and disadvantages Especially, Urea-SCR system have advantages such as a high conversion efficiency and a wide operation conditions. Hence the key factor to implementation of Urea-SCR technology, good mixing of urea(Ammonia) and gas, reducing Ammonia slip. Urea mixer components are required to facilitate evaporation and mixing because the liquid state of urea poses significant barriers for evaporation, and the distance to mixer is the most critical that affect mixer performance. In this study, to find out the distance from injector to mixer and simulation factor, a laser diagnostics and high speed camera are used to analyze urea injector spray characteristics and to present a distribution of urea solution in transparent manifold In addition, Droplet Uniformity Index is calculated from the acquired images by using image processing method to clarify the distribution of spray.