• Title/Summary/Keyword: Root Cause

검색결과 761건 처리시간 0.04초

구조체 균열 하자 저감을 위한 균열 저감형 콘크리트의 기초적 연구 (A Basic Studies of the Concrete Crack Reduction-type Structure for Crack Reduction Flaw)

  • 박희곤;이지환;박기홍
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.197-198
    • /
    • 2016
  • The root cause of the crack flaw occurred in construction. This crack is represented by a construction flaw occurs in the concrete structure. Therefore, we introduce the basic properties for the type of concrete to crack reduction measures to minimize the causes flaw this paper.

  • PDF

Microbial etiology of endodontic treatment failure

  • Kum, Kee-Yeon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.606-606
    • /
    • 2003
  • There have been many studies that have evaluated success and failure of endodontic treatment (Nair, Sjogren), but there is remarkably limited information concerning the specific microorganisms that are involved in the teeth with treatment failure. Microorganisms that survive root canal treatment to cause a persistent infection must possess specific characteristics to avoid the host defense. These can be broadly classified as; 1. Sequestration:A physical barrier between the microbe and the host. 2. Cellular evasion:Microorganisms avoid leukocyte dependent antibacterial mechanisms. 3. Humoral evasion:Extracellular bacteria avoid the hosts antibodies and complement.(omitted)

  • PDF

발전 계획에서 순환 물 펌프 고장 분석 (Failure Analysis of Circulating Water Pump Shaft in Power Plant)

  • Lee, Jaehong;Jung, Nam-gun
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.125-128
    • /
    • 2021
  • This paper presents the root cause failure analysis of the circulating water pump in the 560 MW thermal power plant. A fractured austenitic stainless-steel shaft operated for 24 years was examined. Fracture morphology was investigated by micro and macro-fractographic analysis. The metallurgical analyses including chemical analysis, metallography and hardness testing were performed. The analysis reveals that the pump shaft was fractured due to the reverse bending load with combination of rotating bending load. Corrective actions for plant operator was recommended based on the analysis.

토양 코아 분석을 통한 화산 골프장의 조성된 그린에 대한 평가 (The Evaluation on the exiting greens of Hwasan Country Club by undisturbed Soil Core Analysis)

  • 이상재;허근영;심경구
    • 한국조경학회지
    • /
    • 제26권2호
    • /
    • pp.54-61
    • /
    • 1998
  • The subsurface environment of the root zone area can set the stae for "do or die" of the turfgrass plant. The good condition of the greens is verified by their physical properties. Therefore, this study was carried to evaluate on the existing green of Hwasan C.C. by undisturbed soil Core Anaysis. We completed the ISTRC SYSTEM BenchMarking of the undisturbed core samples taken from Green #1, Green #5, Green #9-"Best" area, and Green #9-"Stressed" area for the Hwasan C.C.. It was also our understanding that the greens were in "good" to "very good" conditioni. THe exception might be Green #9-"Stress" area, which was the stressed area. The stressed area was confined to a ridge across Green #9. The organic content test results comfirmed the development of organic layering in depth 0-2.5cm. For the amount of compaction in the upper root zones and te development of the green's respective organic layers, the infiltration rates were high in Green #1, Green #5, and Green #9 "Stressed" area. The depicted aerificaton hole might be the probable cause of the relatively high infiltraton rate. Green #9-"Best" area had a tested infiltration rate of 18.75cm/hr. Either this area had not been aerified, or the undisturbed sample did not contain a aerification cavity. The water retention capacity of the undisturbed samples was good. When the greens were first constructed, the original root zone mix had been relatively low water retention properties. And the bulk density and the porosity of the undisturbed samples were good. In the result, all the greens were similar except for the infiltration. Thus, we supposed that Green #9-"Stressed" area might be ainly influenced by the amount of irrigation water and the configuration of the green's surface. There had been a reduction in the amount of irrigation water as the water retention capacity in the greens was promoted. Especially, it had gradually become more of a problem as the green had matured in Green #9-"Stressed" area. Because Green #9-"Stressed" area was a ridge area. The reduction in the amount of irrigation water might be the probable cause of the stress in Green #9-"Stressed" area. Our final observation related to the soil texture and the particle size distribution of the sand. Though and sand contant of all the tested greens were good, the gravel content of them exceeded ISTRC Guidelines. In particle size distribution of the sand, the very coarse and the coarse content of all the tested greens exceeded, but the rest was insufficient. The stability is a function of the material retained on the 0.25mm mesh screen. But, the content of all the tested greens was very insufficient. Though all the greens was serviceable, the coarse root zone sands, such as the sand in the tested greens, tended to be "unstable". Thus, we recommend using a topdressing/aerification sand which should be more in line with ISTRC/USGA Guidelines.;unstable". Thus, we recommend using a topdressing/aerification sand which should be more in line with ISTRC/USGA Guidelines.ines.

  • PDF

주파수 응답해석을 통한 풍력발전기용 기어박스의 동특성해석 (Vibration Analysis of wind turbine gearbox with frequency response analysis)

  • 박현용;박정훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.178.2-178.2
    • /
    • 2010
  • The wind turbine gearbox is important rotating part to transmit torque from turbine blade to generator. Generally, gear shaft which rotates causes vibration by influence of stiffness and mass with gear shaft. Root cause of this vibration source is well known to gear transmission error that is decided from gear tooth property. Transmission error excites a gear, and makes excitation force that is vibrated shaft. This vibration of shaft is transmitted to gearbox housing through gearbox bearing. If the resonance about which the natural frequency of the gearbox accords with shaft exciting frequency occurs, a wind turbine can lead to failure. The gearbox for wind turbine should be considered influence of vibration as well as the fatigue life and its performance by such reason. The cause to vibration should be closely examined to reduce influence of such vibration. In this paper, the cause of the vibration which occurs by a gearbox is closely examined and the method which can reduce the vibration which occurred is shown. It is compared with vibration test outcome of a 3MW gearbox for verification of the method shown by this paper.

  • PDF

Use of In-Situ Optical Emission Spectroscopy for Leak Fault Detection and Classification in Plasma Etching

  • Lee, Ho Jae;Seo, Dong-Sun;May, Gary S.;Hong, Sang Jeen
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권4호
    • /
    • pp.395-401
    • /
    • 2013
  • In-situ optical emission spectroscopy (OES) is employed for leak detection in plasma etching system. A misprocessing is reported for significantly reduced silicon etch rate with chlorine gas, and OES is used as a supplementary sensor to analyze the gas phase species that reside in the process chamber. Potential cause of misprocessing reaches to chamber O-ring wear out, MFC leaks, and/or leak at gas delivery line, and experiments are performed to funnel down the potential of the cause. While monitoring the plasma chemistry of the process chamber using OES, the emission trace for nitrogen species is observed at the chlorine gas supply. No trace of nitrogen species is found in other than chlorine gas supply, and we found that the amount of chlorine gas is slightly fluctuating. We successfully found the root cause of the reported misprocessing which may jeopardize the quality of thin film processing. Based on a quantitative analysis of the amount of nitrogen observed in the chamber, we conclude that the source of the leak is the fitting of the chlorine mass flow controller with the amount of around 2-5 sccm.

한국 기업의 대(對)베트남 FDI와 수출 간 인과성 검정 (Causality Tests of Korean Firm's FDI and Exports toward Vietnam)

  • 강지훈
    • 무역학회지
    • /
    • 제45권4호
    • /
    • pp.107-123
    • /
    • 2020
  • The purpose of this paper is to analyze the Granger Causality relations between Korean FDI and exports in Vietnam using time-series from 2005 to 2019. Using 15-industry semi-annual data of Korean FDI and exports toward Vietnam, the Granger Causality Tests were conducted. Var and VEC models were decided after unit-root and cointegration tests of variables. Findings and implications of the empirical tests are as follows. First, unexpectedly FDI did not Grange-cause exports only in one direction. In two industries, food & beverage and medical & chemical products, there were Granger causality relations in both directions. In eight industries including print, publishig, pulp & paper, exports did Grange-cause FDI. In the rest of five industries including automative & trailer industry, there were no Granger Causality relation in both directions. Second, we presume that the both direction-causality relations are desirable phenomenon for Korea. Because Korean FDI and exports are increasing at the same time. On the other hand, substitution relationship between Korea's exports and FDI occur in the industry that exports did Grange-cause FDI. Finally, more in-depth researches considering Vietnam's consumer demand and the oriented characteristics of FDI are needed. The results of this research will contribute to understand structural patterns of FDI and exports in Vietnam and to make investment and export decisions.

Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments

  • Ozyurek, Taha;Tek, Vildan;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.332-341
    • /
    • 2017
  • Objectives: To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. Materials and Methods: The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with ${\chi}^2$ tests using SPSS 21.0 software. Results: New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. Conclusions: This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.