• 제목/요약/키워드: Room to room

검색결과 13,652건 처리시간 0.038초

슬래브의 동특성과 중량충격음의 상관관계에 관한 연구 (Research about correlation of slab vibration mode and heavy-weight floor impact sound)

  • 정진연;이상우;임정빈;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.839-843
    • /
    • 2008
  • Receiving room's floor impact sound level is been influenced to various factor of slab thickness, room size, structure etc. This study examined the noise of upper part slab and room mode in receiving room to be importance factor that influence in receiving room level among this factors. According to this study, vibration mode in slab and room mode are concentrated on frequency that is high level relatively. This causes bad effect in floor impact sound level. Therefore, method to reduce floor impact sound level is to change vibration mode using slab upper part's resilient material or reduce room mode in receiving room.

  • PDF

인공 광원을 이용한 실내 조명 효과에 대한 기초 실험 연구 (Basic Experimental Study on Room Lighting Effects using Artificial Light Source)

  • 김정배
    • 융복합기술연구소 논문집
    • /
    • 제1권1호
    • /
    • pp.29-33
    • /
    • 2011
  • This study is performed to investigate the effect of the artificial light for room lightening. To do that, the experiments were done using the black room with 1m3 and performed to show the effect of the length between the room and light source and light intensities as LUX. The LUX of 18 sites in the room was measured using LUX meter. The length between the room and the light source was chosen as 500mm, 1000mm, and 1500mm and the light intensities was 3 levels. The results were shown the distinct difference between the part directly projected through the light path and non-directly projected. So, the light delivery path have to be modified for next step research. The results were very sensitive for the part directly projected through the light path. This study showed the basic results for room lightening using light source to simulate the solar lightening and was worth in a strict sense as fundamental study.

  • PDF

간이잔향실을 이용한 철도차량 바닥재의 음향투과손실 측정 (Sound transmission loss measurement of railway vehicle floor using semi-reverberation room)

  • 신범식;천광욱;최연선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1420-1425
    • /
    • 2008
  • This study is to examine the sound transmission loss of a railway vehicle floor. To this end, a semi-reverberation room was constructed. The semi-reverberation room was made of a railway vehicle floor between the sound radiating chamber and the sound receiving chamber. To block the sound, the wall was made of acryl, urethane foam, wood, and glass fiber. The test followed the KS F 2808 standard, and a typical reverberation room was used to verify the performance of the semi-reverberation room. As a result, comparison of the measurements showed that the test results of the semi-reverberation room had the same tendency as those of the reverberation room. Consequently it was possible to measure the sound transmission loss of railway vehicle structures using the semi-reverberation room.

  • PDF

미술관 전시벽 구성과 시각적 공간구조의 상관성에 관한 연구 - 개실형 미술관을 중심으로 - (A Study on the Relationship between the Museum Display Wall Composition and the Visual Spatial Configuration - Focusing on the room to room art museum -)

  • 이종숙;임채진
    • 한국실내디자인학회논문집
    • /
    • 제16권5호
    • /
    • pp.63-70
    • /
    • 2007
  • A relationship between the museum display wall composition and the visual spatial configuration is investigated in this study. From the previous research, existing types are classified in order to define the exhibition space of room to room. Based on the classification, an open room to room of art museum is defined as a room to room of museum, and the plane of museums is investigated. With the museums under this study, the wall of a room to room exhibition space as well as the visual spatial configuration are analyzed depending on the location of an opening, centering on the composition of unit space. In addition, two types of spatial composition are compared depending on the location of the opening. One type of spatial composition is lied on a straight line with visual continuity, and the visual line is found to be simple. Whereas, the other type has an invisible configuration between spaces due to a criss-crossed opening, so the space is perceived to be closed and disconnected. When comparing these two types, the advantage and disadvantage of each space are compared. As a result, a similar type and size of unit space are derived. In addition, the ratio of the opening compared to the total wall was found to be uniform, and a distribution of the opening and walls were found.

국어사전과 건축용어사전을 통해서 본 일실주거의 용어 변화 및 의미 분석 (Terminology and Meanings of One-room Dwelling in Korean Dictionaries and Dictionaries of Architecture Terms)

  • 이미숙;서귀숙
    • 한국주거학회논문집
    • /
    • 제25권2호
    • /
    • pp.55-62
    • /
    • 2014
  • The terms of the one-room dwelling began to attract attention according to increasing of 1-2 person households in the 1990s. The purpose of this study is to analyze the meaning of the terms about one-room dwelling written in the Korean dictionaries and the dictionaries of architecture terms. For this purpose, the first study was divided into three periods. The second study investigated publishing of the Korean dictionaries and the dictionaries of architecture terms and analyzed meaning of the one-room dwelling written in the Korean dictionaries and the dictionaries of architecture terms. The result are summarized as follows. 1) 'Bang' and 'Sil', the smallest residence unit, have sense of the living space. 2) The terms written in dictionaries were five terms. It is Dankanbang, Dankan house, Ilsil house, One-room house, Ilsil dwelling. 3) Dankanbang and Dankan house meant a detached house and only a single room. 4) Ilsil house, One-room and Ilsil dwelling meant a multi-unit dwelling. Dwelling type combined unit space in a single room. 5) One-room and Ilsil dwelling focused on convenience and multipurpose. The result of this study is expected to provide useful information for small sized housing study.

초청정 클린룸 난류유동장내에서의 오염입자 비정상 전파거동에 관한 연구 (Study on the Unsteady Contaminated Particle Transportation in the Flow Field for the Super Clean Room)

  • 오명도;임학규;배귀남
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.430-439
    • /
    • 1990
  • Steady state turbulent airflow and unsteady characteristics of generation, transportation, and recovery behavior of contaminate particles in the simplified 2 dimensional Vertical Laminar Flow (VLF) type clean room was numerically simulated using the low Reynolds number k-over bar.epsilon- turbulent model. Characteristics of airflow in VLF type clean room are greatly affected by the recirculation zone around working surface. The recirculation zone must be considered at the time of clean room design because the recirculation zone whose area increases with increment of inlet velocity exerts bad influence upon the performance of clean room in terms of particle contamination. The location of maximum particle concentration changes from the location of particle source to the recirculation zone, while averaged particle concentration is reduced exponentially with time. Recovery time of clean room with spontaneous particle generation source is inversely proportional to inlet velocity. We introduce nondimensionalized recovery time through the dimensional analysis, which can indicates the general performance of clean room with design structure change. It was identified that .tau. is independent of inlet velocity and background concentration. Therefore .tau. can be the simple factor to compare the different structure of clean room in terms of dynamic response to contamination and becomes larger with better structure of clean room.

다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발 (Development of shipboard large-sized low-noise room unit with multiple outlets)

  • 김상렬;김현실;이성현;박근효
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.600-605
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlet. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

  • PDF

다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발 (Development of Shipboard Large-sized Low-noise Room Unit with Multiple Outlets)

  • 김상렬;김현실;이성현;박근효
    • 한국소음진동공학회논문집
    • /
    • 제22권5호
    • /
    • pp.468-473
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlets. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

대학강의실 전면현휘 감소를 위한 주간채광유입 시뮬레이션에 관한 연구 (A Study on Simulation of Daylight for Reducing Glare of the Lecture Room's Front Side in University)

  • 정지석
    • 한국주거학회논문집
    • /
    • 제24권3호
    • /
    • pp.1-8
    • /
    • 2013
  • The University students learn their major or a general education in lecture rooms. In these days, lecturer use frequently various multimedia in lecture room. Appropriate control lighting environment in lecture room should be essential and related in efficient studying. Daylighting on front-side of lecture room will cause glare and students are hard to read contents on white-board at their seat. Therefore, in order to preventing glare we simulated daylighting of lecture room with using computer software in this study. Results from simulation and analysis as follows: The first, if students' left-side is east-oriented in lecture room, best daylighting condition about glare in lecture room. The second, architectural designers can use simulation data of daylighting or simulate data in designing university buildings with lecture rooms. Finally, if reducing size of windows (narrow and deep daylight: more closing vertically, from up to down daylighting: more closing horizontally) we will be able to reduce energy from lecture room.

분만실 간호사의 근무 경험에 관한 현상학적 연구 (Work Experiences of Delivery Room Nurses: A Phenomenological Study)

  • 이윤정
    • 여성건강간호학회지
    • /
    • 제23권2호
    • /
    • pp.78-88
    • /
    • 2017
  • Purpose: This study aimed to understand meaning and essentials in work experiences of delivery room nurses. Methods: A phenomenological perspective was used for this qualitative research. Ten delivery room nurse with more than 3 years of work experience participated in this study. Data were collected through individual in-depth interviews with the nurses, between December 2012 and April 2013. Data were analyzed using Colaizzi's method. Results: Nine theme clusters and four categories emerged from the data as follows: 1) factors influencing career decision-making, 2) gap between reality and expectations, 3) difficulties with working in the delivery room, and 4) motivation to work in the delivery room. Conclusion: Based on the results of this study, strategies to improve working environment of the delivery room nurses are necessary. Also, better policy are required to firmly establish the role of the delivery room nurses' role as recognized professionals.