• Title/Summary/Keyword: Room resonance

Search Result 187, Processing Time 0.024 seconds

ESR Signal in Different Cuts of Irradiated Chicken, Pork and Beef

  • Nam, Hye-Seon;Yang, Jae-Seung;Ly, Sun-Yung
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.254-260
    • /
    • 2000
  • Electron spin resonance (ESR) spectroscopy was used to detect irradiated meat containing bones (chicken, pork and beef), to investigate the effect of irradiation dose on the ESR signal intensity and to identify the stability of radicals under 9 weeks of storage. Chicken, pork and beef were irradiated with doses 0, 1, 3, 5 and 7 kGy at room temperature using a Co-60 irradiator. Bones were pieced and dried, which were placed in a quartz tube within an Electron paramagnetic resonance (EPR) spectrometer resonator cavity. The irradiated bone presented an asymmetric absorption in shape, different from that of a non-irradiated one. The signal intensity of smaller animals are lower than larger species. Variation was observed between samples of the same species depending on the calcification status of the bone. Moreover different irradiation doses produced different signal areas that make possible to estimate the absorbed dose of treated meat. The ESR signal stability after irradiation was stable in even after a 9 week storage at room temperature.

  • PDF

Analysis of Natural Frequency of Simple Steel Outfitting Structure in Engine Room (기관실 단순 철의장품 모델 고유 진동수 해석)

  • Jung, C.S.;Kim, D.S.;Cho, S.A.;Chang, S.I.
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2006.09a
    • /
    • pp.106-111
    • /
    • 2006
  • The steel outfitting structures installed in engine room are vibrated by an excitation of the engine and the propeller. Vibration problems such as cracks and fitting breakages are mainly induced at the near range of the resonance. The excitation frequency estimation is possible by engines and propeller specifications, but the natural frequency of a steel outfitting structure is not easily estimated due to the complication and variety of the designed shape. This paper represents natural frequency data of simple steel outfitting structures. As a vibration analysis tool, MSC/NASTRAN was used to calculate natural frequencies. Natural frequencies were compared in case of the shape and boundary condition changes of simple models, and anti-vibration models of the steel outfitting structures were presented on the basis of results.

  • PDF

Study on the Electromagnetic Shielding of Accessory Device without Electromagnetic Shielding Technology in the Magnetic Resonance Room (자기공명검사실 내 전자기파 차단이 이루어지지 않은 부속장치의 차폐에 관한 연구)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.2
    • /
    • pp.431-436
    • /
    • 2021
  • In this study, a new shielding method was applied to an accessory device that produces electromagnetic waves in the magnetic resonance room to prevent the generation of artifact caused by electromagnetic waves. The research method applied a new shielding made of metal plating fiber to patient surveillance CCTVs without shielding technology, and obtained and evaluated noise map when the power was not cut off and when the new shielding technology was applied without shutting down the CCTV. As a result of the study, it was found that there was at least one group with significant differences. Type I and type III belonged to group 1 while type II belonged to group 2 in the Post-hoc analysis, which meant blocking power of the CCTV and the applying new shielding technology were in the same group. In conclusion, if electromagnetic waves are generated due to additional accessories in the scanning room, the shielding material proposed in this study should be applied which enables the electric state become similar to type I, not generating noise, thereby preventing the artifacts caused by electromagnetic waves.

Ferromagnetic Resonance Observation of Martensitic Phase Transformation in Ni-Mn-Ga Ferromagnetic Shape Memory Films

  • Dubowik, J.;Kudryavtsev, Y.V.;Lee, Y.P
    • Journal of Magnetics
    • /
    • v.9 no.2
    • /
    • pp.37-39
    • /
    • 2004
  • Polycrystalline Ni-Mn-Ga films have been deposited onto mica substrates held at 720 K by flash-evaporation method. At room temperature the films have a tetragonal structure with a = b = 0.598 and c = 0.576 nm typical for bulk $Ni_2MnGa$ below a martensitic transformation. Temperature measurements of ferromagnetic resonance reveal a martensitic phase transformation at 310 K. The transformation brings about a substantial decrease in the effective magnetization and a drastic increase in the ferromagnetic resonance linewidth due to a strong increase in the magnetic anisotropy in the martensitic phase.

A New Method for Antimicrobial Susceptibility Testing of Vitro-cultured Bacteria by Means of Resonance Light Scattering Technique

  • Shi, Yu-Jun;Chen, Jun;Xu, Ming
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.118-123
    • /
    • 2008
  • A new method for antimicrobial susceptibility testing of vitro-cultured bacteria on an ordinary fluorescence spectrometer was developed. The viable bacteria reduced 3-(4,5 dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) to produce insoluble particles that displayed intense resonance scattering light. The assay showed a linear relationship between the number of viable bacteria and the intensity of resonance scattering light. Dead bacteria were unable to reduce MTT. Methicillin-resistant Staphylococcus aureus exposed to flavonoids from Marchantia convoluta showed a flavonoids concentration-dependent inhibition of the ability to reduce MTT. In the assay, less than 12 h was required to attain susceptibility results and fewer bacteria were utilized than in traditional methods. The RLS technique could, in combination with the MTT assay, be a rapid and sensitive measuring method to determine the in vitro activity of new antimicrobials.

Reduction of Flow-Induced Vibration in the Heat Exchanger (열교환기에서의 유동유발 진동 저감)

  • 장한기;김승한;이재현;양정렬
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1200-1209
    • /
    • 1999
  • This paper reports a peculiar example of flow-induced vibration in a very large plant and the whole procedure of reducing the vibration. During the operation of flue gas desurfurization unit of the thermal power plant, serious vibration was dtected at all around the plant. The worst vibration was recorded on the heat exchanger surface, which weighed 180 tones, as 17.8 m/$s^2$ in vibration amplitude at 34 Hz. To identify the vibration, frequency analysis on the response vibration as well as on the expected excitation forces and the system resonance was executed. This investigation revealed that the cause of the vibration was vortex shedding from the circular pipes in the heat exchanger. Vortices from the pipes excited acoustic resonance in the heat exchanger room, which, in turn, made the structure vibrate. Through inserting the baffles between the pipes, which had an effect of cutting the acoustic wave at resonance frequency, the vibration was eliminated dramatically.

  • PDF

Film Bulk Acoustic Resonator(FBAR) using Bragg Reflector for IMT-2000 Bandpass Filter (Bragg 반사층을 이용한 IMT-2000 대역통과필터용 체적 탄성파 공진기)

  • 김상희;김종헌;박희대;이시형;이전국
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.377-382
    • /
    • 2000
  • Film bulk acoustic resonator (FBAR) using AIN reactively sputtered at room temperature was fabricated. The FBAR is composed of a piezoelectric aluminium nitride thin film, top electrode of Al and bottom electrode of Au connected by a short (200${\mu}{\textrm}{m}$) transmission line on both sides and reflector layers of SiO$_2$- W Pair. The active areas of Al and Au were patterned using 150${\mu}{\textrm}{m}$ diameter shadow mask. The series resonance frequency (fs) and the parallel resonance frequency (fp) were measured at 1.976 GHz and 2.005 GHz, respectively. The minimum insertion loss and return loss were 6.1 dB and 37.19 dB, and the quality factor (Q) was 4261.

  • PDF

Late Onset Postpartum Seizure and Magnetic Resonance Image Findings

  • Hwang, Sung-Nam;Park, Jae-Sung;Park, Seung-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.6
    • /
    • pp.453-455
    • /
    • 2005
  • Two young women were brought to the Emergency room with generalized tonic and clonic seizures. Seizure developed seven and ten days after delivery respectively without the clinical signs of pre-eclampsia throughout the pregnancies. Magnetic resonance(MR) image of the brain showed characteristically symmetrical abnormal signals in the parietal and occipital regions. After several days of medical treatment, they were discharged without neurologic sequelae and follow-up MR images taken three months after discharge showed complete disappearance of the previous abnormal signals.

Comparison Analysis of Donor Liver Volumes Estimated with 3D Magnetic Resonance and 3D Computed Tomography Image Data

  • Kim, Myeong-Seong;Park, Kyeong-Seok;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.261-265
    • /
    • 2014
  • Three-dimensional computed tomography is an effective tool to estimate the liver volume of living donors for the live liver transplantation. When additional operation is required, magnetic resonance imaging is conducted to determine the safety of the donor. This study compared the accuracy of magnetic resonance imaging and computed tomography in estimating 3D liver volume of 23 male and 7 female donors who underwent both magnetic resonance imaging and computed tomography tests before the transplantation. The analysis was conducted to see whether the liver's estimated total volumes and the left lobe volumes obtained from 3D-magnetic resonance imaging and 3D-computed tomography were identical. Volumes of the right lobe estimated with 3D-magnetic resonance imaging and 3D-computed tomography were compared with the actual volume of the right lobe harvested in the operating room because the volume of the right lobe is an important determinant in the safety of the donor. The total volume of the liver estimated from 3D-magnetic resonance imaging and 3D-computed tomography differed (1238.1904 units and 1402.364 units respectively). The left lobe volume of the liver estimated with 3D-magnetic resonance imaging and 3D-computed tomography also differed (450.530 units and 554.490 units, respectively). The right lobe volume of the liver estimated with 3D-magnetic resonance imaging and 3D-computed tomography were 787.660 units and 847.545 units, respectively, while the actual average right lobe volume of the harvested liver was 678.636 units. 3D-computed tomography has been widely used to estimate the right lobe volume of the donors' liver. However, 3D-magnetic resonance imaging was also very effective in estimating the volume of the liver. Thus, 3D-magnetic resonance imaging is also expected to become an important tool in determining the safety of the donors before transplantation.

Effect of the Annealing Conditions on the Ferromagnetic Resonance of YIG Thin Film Prepared on GGG Substrate (Gd3Ga5O12 기판위에 성장된 Y3Fe5O12 박막의 열처리 조건에 따른 강자성 공명 특성 연구)

  • Lee, Yelim;Phuoc, Cao Van;Park, Seung-Young;Jeong, Jong-Ryul
    • Korean Journal of Materials Research
    • /
    • v.25 no.12
    • /
    • pp.703-707
    • /
    • 2015
  • In this study, we investigated the effect of annealing conditions on the ferromagnetic resonance(FMR) of yttrium iron garnet ($Y_3Fe_5O_{12}$, YIG) thin film prepared on gadolinium gallium garnet ($Gd_3Ga_5O_{12}$, GGG) substrate. The YIG thin films were grown by rf magnetron sputtering at room temperature and were annealed at various temperatures from 700 to $1000^{\circ}C$. FMR characteristics of the YIG thin films were investigated with a coplanar waveguide FMR measurement system in a frequency range from 5 to 20 GHz. X-ray diffraction(XRD) and X-ray photoelectron spectroscopy(XPS) were used to characterize the phase formation, crystal structure and composition of the YIG thin films. Field dependent magnetization curves at room temperature were obtained by using a vibrating sample magnetometer(VSM). The FMR measurements revealed that the resonance magnetic field was highly dependent on the annealing condition: the lowest FMR linewidth can be observed for the $800^{\circ}C$ annealed sample, which agrees with the VSM results. We also found that the Fe and O composition changes during the annealing process play important roles in the observed magnetic properties.