• Title/Summary/Keyword: Room resonance

Search Result 188, Processing Time 0.024 seconds

Measurement of excited species in discharges using Laser Absorption spectroscopy

  • Sakai, Yosuke
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.5-8
    • /
    • 2000
  • The population density of excited species in dc, rf and laser ablation plume plasmas has been measured using laser absorption spectroscopy. It was shown that, when the plasma was modulated by on and off with, the sensitivity and signal to noise (S/N) ratio became high. For example, the atomic O(3$^{5}$ S$^{o}$ $_2$) Population density, No* in $O_2$/He mixtures was obtained by the highest S/N ratio at a frequency of 2.7kHz. In a 20Torr room air, the lowest No* level to be detectable was shown to be an order of 10$^{7}$ cm$^{-3}$ . The population densities of resonance Ar(1S$_2$) and Xe(1S$_4$) levels were also measured in barrier discharges and laser ablation plasmas.

  • PDF

Fabrication and characteristics of polycrystalline SiC micro resonators (다결정 SiC 마이크로 공진기의 제작과 그 특성)

  • Chung, Gwiy-Sang;Lee, Tae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.425-428
    • /
    • 2008
  • This paper describes the resonant characteristics of polycrystalline SiC micro resonators. The $1{\mu}m$ thick polycrystalline 3C-SiC cantilevers with different lengths were fabricated using a surface micromachining technique. Polycrystalline 3C-SiC micro resonators were actuated by piezoelectric element and their fundamental resonance was measured by a laser vibrometer in vacuum at room temperature. For the $100{\sim}40{\mu}m$ long cantilevers, the fundamental frequency appeared at $147.2kHz{\sim}856.3kHz$. The $100{\mu}m$ and $80{\mu}m$ long cantilevers have second mode resonant frequency at 857.5.kHz and 1.14.MHz, respectively. Therefore, polycrystalline 3C-SiC resonators are suitable for RF MEMS devices and bio/chemical sensor applications.

Displaced Scapula Fracture (Ideberg Type IIb) Combined with a Large Rotator Cuff Tear in Anterior Shoulder Dislocation: A Case Report

  • Noh, Young-Min;Kim, Chul-Hong;Lee, Seung-Hyun;Im, Chul-Soon
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.162-166
    • /
    • 2017
  • Traumatic anterior shoulder dislocation combined with scapular fracture in elderly patients is relatively rare. In this case, a patient visited Emergency Room of Dong-A University Hospital for shoulder pain after falling off a ladder. Radiographs demonstrated anterior shoulder dislocation with displaced Ideberg type IIb scapula (glenoid fossa) fracture combined with a large rotator cuff tear on magnetic resonance imaging. We performed arthroscopic rotator cuff repair, but a large fragment in the inferior glenoid was left untreated. At the 1 year follow-up visit, the pain visual analogue scale of the patient was 2, the American Shoulder and Elbow Society score was 88 and the patient had gained nearly full range of motion without any apprehension.

A study on radiation degradation of LDPE by using ESR (ESR을 이용한 저밀도 폴리에틸렌의 방사선 열화에 관한 연구)

  • Kim, Ki-Yup;Kim, Jin-Ah;Lee, Chung;Kim, Pyeong-Jong;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.473-476
    • /
    • 2004
  • This study has investigated radiation degradation of low density polyethylene(LDPE). Samples were irradiated using a $Co^{60}\;\gamma-ray$ and ray up to 800 kGy at a dose rate of 5 kGy/hr in the presence of air atmosphere at room temperature. After irradiation, free radical measurement of LDPE has established by electron spin resonance(ESR). Then, each sample was stored for 2 weeks. ESR measurement showed that free radical concentration(FRC) was increased with radiation dose and changed from alkyl, allyl radical to peroxy radical with time.

  • PDF

Noise and Vibration Characteristics of Heavy-weight floor impact by Using Damping Materials (감쇠재 사용에 따른 중량충격음의 소음 및 진동특성)

  • Jeon, Jin-Yong;Jeong, Young;Song, Hee-Soo;Kim, Min-Bae;Lee, Young-Je
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.97-102
    • /
    • 2004
  • The Characteristics of noise and vibration by heavy-weight floor impact sound was studied. Resonance frequency increased a little in structures that use damping material in living room and bedroom, and acceleration waves length that respond became short, and displayed aspect that oscillation level decreases. Result that measure sound pressure level, structure that compare and applies damping materials with structure that apply the resilient materials from 63Hz lower part that impact energy is concentrated in energy spectrum of heavy-weight floor impact sound displayed result that sound pressure, level decreases remarkably. Therefore, according to use of damping materials, confirmed reduction effect of heavy-weight floor impact sound.

  • PDF

Isotropic NMR Shifts in Some Pyridine-Type Ligands Complexed with Paramagnetic Undecatungstocobalto(Ⅱ)silicate and Undecatungstonickelo(Ⅱ) silicate Anions. Identifications of Dumbbell-Shaped 4,$4^{\prime}$-Bipyridyl Complexes

  • Moonhee Ko;Gyung Ihm Rhyu;Hyunsoo So
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.4
    • /
    • pp.500-506
    • /
    • 1993
  • $^1H$ and $^{13}C$ NMR spectra for pyridine, ${\beta}$-and ${\gamma}$-picoline, pyrazine, and 4,4'-bipyridyl complexed with paramagnetic undecatungstocobalto(II)silicate and undecatungstonickelo(II)silicate anions are reported. For these complexes the ligand exchange is slow on the NMR time scale and the pure resonance lines have been observed at room temperature. The isotropic shifts in nickel complexes can be interpreted in terms of contact shifts by ${\sigma}$-electron delocalization. Both contact and pseudocontact shifts contribute to the isotropic shifts in cobalt complexes. The contact shifts, which are obtained by subtracting the pseudocontact shifts from the isotropic shifts, require both ${\sigma}$-and ${\pi}$-electron delocalization from the cobalt ion. Slow ligand exchange has also allowed us to identify the species formed when bidentate ligands react with the heteropolyanions. Pyrazine forms a 1 : 1 complex, while 4,4'-bipyridyl forms both 1 : 1 and dumbbell-shaped 1 : 2 complexes.

$^{63}Cu$ NQR Study of the Anisotropy in $YBa_{2}Cu_{3}O_{7}$ ($YBa_{2}Cu_{3}O_{7}$의 비등방성에 관한 $^{63}Cu$ 핵사중극공명 연구)

  • B. Chang;Cheol-Eui Lee
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.1
    • /
    • pp.48-51
    • /
    • 1994
  • We have studied the room temperature anisotropy in the high $T_{c}$ superconductor $YBa_{2}Cu_{3}O_{7}$ by means of the $^{63}Cu$ nuclear quadrupole resonance (NQR). For the magnetically oriented powder samples, NQR signals were obtained only when the RF magnetic field is applied perpendicular to the direction of the crystalline c-axis. Significant differences in the spin-lattice relaxation times ($T_{1}$) and the lineshapes were observed between the unoriented powder sample and the magnetically oriented sample.

  • PDF

Cardiac Arrest in Conjunction with Hypoglycemia in a Non-Diabetic Patient with Cerebral Infarction (당뇨병이 없는 뇌경색 환자에서 발생한 저혈당과 동반된 심정지)

  • Ko, Jeongmin;Lee, Ji-Yong
    • Journal of Neurocritical Care
    • /
    • v.11 no.2
    • /
    • pp.143-147
    • /
    • 2018
  • Background: Hypoglycemia is uncommon in people without diabetes. There have been only a few reports of cardiac arrest in conjunction with hypoglycemia in non-diabetic patients. Case Report: A 66-year-old man visited the emergency room with dizziness. He was a chronic alcoholic. Laboratory test showed no evidence of diabetes mellitus. Brain magnetic resonance imaging revealed a left cerebellar infarction. Abdomen computed tomography demonstrated liver cirrhosis with minimal ascites. During his hospital stay, he consumed only a small amount of food because of nausea and headache. On hospital day 4, he had a cardiac arrest after two seizure episodes. His blood glucose was 10 mg/dL. The combination of liver cirrhosis, renal failure and poor oral intake was presumed to be the causes of the severe hypoglycemia. Conclusion: We report a rare case of cardiac arrest occurring in conjunction with severe hypoglycemia in a non-diabetic patient with cerebral infarction.

Shape Oscillation and Detachment of Droplet on Vibrating Flat Surface (진동하는 평판 위의 액적의 형상 진동 및 제거 조건에 대한 연구)

  • Shin, Young-Sub;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.4
    • /
    • pp.337-346
    • /
    • 2014
  • This study aimed to understand the mode characteristics of a droplet subject to periodic forced vibration and the detachment of a droplet placed on a plate surface. An surface was coated with Teflon to clearly observe the behavior of a droplet. The contact angle between the droplet and surface and the hysteresis were found to be approximately $115^{\circ}C$ and within $25^{\circ}C$, respectively. The coating process was performed in a clean room that had an environment with a low level of contaminants and impurities such as air dust, detergents, and particles. To predict the resonance frequency of a droplet, theoretical and experimental approaches were applied. Two high-speed cameras were configured to acquire side and top views and thus capture different characteristics of a droplet: the mode shape, the detachment, the separated secondary droplet, and the waggling motion. A comparison of the theoretical and experimental results shows no more than 18 discrepancies when predicting the resonance frequency. These differences seem to be caused by contact line friction, nonlinear wall adhesion, and the uncertainty of the experiment. For lower energy inputs, the contact line of the droplet was pinned and the oscillation pattern was axisymmetric. However, the contact line of the droplet was de-pinned as the oscillation became more vigorous with increased energy input. The size of each lobe at the resonance frequency is somewhat larger than that at the neighboring frequency. A droplet in mode 2, one of the primary mode frequencies, exhibits vertical periodic movement as well as detachment and secondary ejection from the main droplet.

Noise Exposure of Radiographer Caused by Magnetic Resonance Imaging(MRI) (자기공명영상(MRI) 검사 시 방사선사의 소음노출)

  • Gil, Jong-Won
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.699-706
    • /
    • 2016
  • This study aimed to propose the necessity and system establishment of noise reduction facility via evaluating noise level exposed by the radiographer due to MRI scan. Noise measurements were carried out using at S general hospital in Daejeon using 1.5 Tesla MRI (7 exams) and 3.0 Tesla MRI (16 exams), while using SC-804 noise meter. The measurement distance was from the soundproof door of the MRI room to the radiographer which measured 100cm, and the measurement height, the height to the radiographer's ears when working, 100cm. The noise measured for each exam was an average of three measures per exam which observed the noise occurring in each sequence recorded every 20 seconds. As the results, the maximum of noise exposed by the radiographer is 73.3 dB(A), which is MRCP by the 3.0 Tesla device, and also the maximum of average noise is 66.9(3.1) dB(A), which is Myelogram by the 3.0 Tesla device. Average noise by each device is 61.9(4.1) dB(A) by the 3.0 Tesla device and 52.0(3.1) dB(A) by the 1.5 Tesla device, which comes to the result that the 3.0 Tesla MRI device is about 10 dB(A) degree higher(p <0.001). The noise level exposed by the radiographer does not affect auditory acuity, but the level is able to incur a non auditory effect. The reflect sound can be removed by installing curtains in the rear wall of MRI control room in order to reduce the noises, but, first of all, An institutional system is needed in order to prevent noise.