• Title/Summary/Keyword: Room air-conditioner

Search Result 109, Processing Time 0.026 seconds

The Influence of the Intake Regions of the Cross-flow fan on the Performance and Fan Noise (횡류팬 흡입구의 위치가 성능 및 소음 특성에 미치는 영향)

  • Kim, Jin Baek;Choi, Weon Seok;Lee, Jai Kwon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.78-82
    • /
    • 2004
  • The cross-flow fan which is used for air-conditioner indoor units were studied experimentally. The recent trend shows that the room air-conditioners need to be good-looking. According to the visual design concepts the intake regions of the fan can vary, which leads to the loss of the performance and the increase of the noise of the fan. In order to optimize the performance of the fan and minimize the aerodynamic noise for the system, the performance characteristics and the noise of the cross-flow fan have been investigated at the various conditions of the intake region of the unit.

  • PDF

Design Optimization of an Accumulator for Noise Reduction of Rotary Compressor (공조용 로터리 압축기 소음저감을 위한 어큐뮬레이터 최적설계)

  • Lee, Ui-Yoon;Kim, Bong-Joon;Lee, Jeong-Bae;Sung, Chun-Mo;Lee, Un-Seop;Lee, Jong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.759-766
    • /
    • 2011
  • Recently, noise reduction in room air conditioners has been one of the important issues as well as cooling efficiency. The rotary compressor is the dominant noise source in an air conditioner. A number of studies have been conducted on reducing compressor noise through improving muffler and resonator design. However the noise from the accumulator, a noise delivering path between compressor and air conditioner, is not fully taken into consideration. The accumulator contains a large inner cavity, and usually generates additional resonance noise during operation. This paper aims to conduct an optimal design for reducing accumulator noise by maximizing the transmission loss within the target frequency range that represents high-order nonlinearity. Design of experiments and radial basis function neural network are used in the context of approximate meta-models, and genetic algorithm is used as an optimization tool.

The Friction Characteristics of the Journal Bearing in the Refrigerant Compressor

  • Cho, Ihn Sung;Baek, Il Hyun;Oh, Seok Hyung;Jung, Jae Youn
    • KSTLE International Journal
    • /
    • v.1 no.2
    • /
    • pp.113-117
    • /
    • 2000
  • The rotary-vane compressor has become one of the most successful types of compressors because of its mechanical reliability, compactness, and adaptability to moderately high-speed operation in virtually an unlimited range of sizes. However recently, the depletion of the ozone layer due to the current refrigerant(R22) has been getting worse, and it is one of the world's pressing issues. In this paper, we will discuss the use of R410a in the compressor of a room air-conditioner as an alternative refrigerant and air-conditioning system to R22, since R410a has greater refrigerant characteristics than R22. Miniaturization of the rotary compressor for the new refrigerant and air-conditioning system is also possible, which reduces the prime cost of production, hence R410a is naturally a better refrigerant. But to apply the new HFC refrigerant system in refrigeration and air-conditioning systems, a significant redesign of the current refrigerant system is also required, because as the refrigeration changes, lubrication characteristics vary. Close attention must be paid to friction force and energy loss due to friction and wear at many sliding areas.

  • PDF

Analysis of Comfortable Environment in the Classroom with Humidification and Ventilation in Winter (겨울철 가습 및 환기에 따른 교실내 쾌적환경 분석)

  • Sheng, Nai-Li;Cheong, Seong-Ir;Lee, Jae-Keun;Park, Jong-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1213-1219
    • /
    • 2008
  • This experimental study was to analyze thermal comfort and indoor air quality(IAQ) with ventilation and humidification in the classroom when system air conditioner was operated. The thermal comfort was estimated by the PMV index and the concentration of $CO_2$ and total suspended particle(TSP) were measured and compared with ventilation and humidification. As a result, the class room temperature distribution was $2{\sim}5^{\circ}C$ low during operating ventilation system and humidification. At 60% RH, PMV values of measuring points were ranged from +0.5 to -0.5 indicating optimal the range of thermal comfort. The average concentration of $CO_2$ gas and TSP were reduced 645 ppm, 0.17 mg/$m^3$ respectively, during operating the ventilation system. From the results, to maintain comfortable environment in the heated classroom, the ventilation and humidification were needed in winter season.

  • PDF

A STUDY ON THE REMOVAL OF DENTINAL SMEAR LAYER BY DENTIN CONDITIONER (상아질처리제(象牙質處理劑)에 의(依)한 상아질(象牙質) 표면(表面) 도말층(塗抹層)의 제거(除去)에 관(關)한 연구(硏究))

  • Ahn, Hyun-Mi;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.65-76
    • /
    • 1989
  • The purpose of this study was to observe the effect on the removal of dentinal smear layer and morphological changes of reduced dentin surfaces by various dentin surface conditioners. Thirty-two healthy human premolars extracted due to periodontal or orthodontic reasons were used. The teeth were cross-sectioned to expose dentin at the middle portion of the crown with diamond rotary saw. The specimens were then divided into 8 groups. The sectioned dentin surfaces in group 1 to 4 were grinded with No. 400 grit silicone abrasive paper and those in group 5 to 8 were cut with #700 carbide bur under air-water spray. The grinded or cut dentin surfaces were conditioned with 3% $H_2O$, Dentin Conditioner(GC Inter. Corp., Japan), and Scotchprep(3M Dent Prod., U.S.A) according to manufacturer's directions. All the specimens were dried in room temperature for 48 hours, and gold-coated with Eiko ion coater(Eik-engineering Co.), and observed in Hitachi S-450 Scanning electron microscope at 15-25 KV. The following results were obtained; 1. The dentin surfaces grinded with the silicon abrasive paper were rougher in texture and heavier in amount of smear layer than those cut with the carbide bur. 2. Scrubbing of 3% $H_2O_2$ was not effective in removing dentinal smear layer. 3. 20-second conditioning of Dentin Conditioner (GC Inter. Corp) resulted in the removal of a significant amount of the smear layer without removing the tubular plugs and dissolving the peritubular dentin. 4. Scotchprep removed the smear layer very effectively. But at the same time it dissolved the peritubular dentin. 5. Irrespective of the uses of the silicon carbide abrasive paper or the carbide bur the morphological changes of dentin surfaces treated with the same conditioning agents were similar.

  • PDF

Development of Optimal Control System for Lighting and HVAC(Heating, Ventilation, Air Conditioning) Using Energy Saving (에너지 절감용 조명 및 공조기기 최적제어 시스템 개발)

  • Jang, Woo-Sung;Song, Yeoung-Seok;Cho, Byung-Lok;Cho, Seok-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1029-1036
    • /
    • 2018
  • This paper is a study on the development of optimal control system for lighting and air conditioning equipment to save the energy in campus environment. In the case of controling system developed through this research, lighting and air conditioner are controlled by both information on the number of people entering and leaving the room through the motion sensor and image processing, and the information on temperature and humidity. In addition, energy saving is enabled by the results that are controlled through data integration monitoring and command execution functions according to the control signals.

The vibration and noise characteristic analysis of the BLDC Axial-gap type motor by using Finite Element Method (FEM 을 이용한 BLDC Axial-gap type 전동기의 진동과 소음 특성 분석)

  • Lee, Taeck-Jin;Park, Jun-Hong;Lee, Sang-Ho;Hong, Jung-Pyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.943-946
    • /
    • 2007
  • The vibration and noise characteristic of the Axial-gap motor for an air conditioner were analyzed. Experimental Modal Analysis was performed to understand the vibration characteristic of the motor. The noise of motor was measured in a dead room. Finite Element Method was performed to find the vibration characteristic of the motor by using ABAQUS program.

  • PDF

Study of Muffler for Rotary Compressor by Taguchi Method Viewpoint (회전형 압축기용 머플러의 연구 (1) : 다꾸찌 기법 관점에서)

  • 박성근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.542-547
    • /
    • 1998
  • As the concern for a global energy conservation and environmental protection are increasing, it has been more important thing to correspond with CFC depletion. Alternate refrigerants have merit such as lower global warming effect, but also have demerits such as lower efficiency, miscibility, increasing noise and poor reliability problems. Then we have to develop more efficient, silent and robust compressors to satisfying world-wide demand. In this paper, parametric study on rotary compressor muffler for a room air-conditioner was carried out to investigate the effect of important design variables on noise by using Taguchi robust design method with signal-to-noise(S/N) ratio. Taguchi method seems to be helpful for finding optimum value of design variables for noise level. We also applied neural network to find optimal value of design variables.

  • PDF

Development of Visualization Technique for Analysis of Internal Flow for Cross-flow Fan (횡류팬 내부 유동 분석을 위한 가시화 기법 개발)

  • Lee, A-Mi;Han, Kyu-Il;Joo, Jae-Man;Na, Seon-Uk;Kim, Dong-Won;Ko, Han-Seo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.515-516
    • /
    • 2006
  • Internal and inlet flows of a cross-flow fan have been visualized using a particle image velocimetry(PIV) to analyze a relationship with a performance of a room air conditioner(RAC). A test model which has a geometric similarity with the real RAC has been manufactured for the experiment and the flow characteristics have been analyzed with various flow rates and inlet grill angles for the cross-flow fan. The experimental results using the PIV technique have been compared with the existing numerical results. Also, a location and movement of an eccentric vortex which can affect the performance and noise of the RAC has been investigated by the PIV with various flow rates and inlet grill angles.

  • PDF

Computational Flow Analysis of a Cross-Flow Fan by LES (LES에 의한 관류홴의 전산유동해석)

  • Kim, J.K.;Oh, S.H.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.20-28
    • /
    • 2010
  • The computational flow analysis using LES technique was carried out to investigate the flow characteristics of a RAC chassis consisting of a rear-guider, a stabilizer and a cross-flow fan. The commercial SC/Tetra software was used in this analysis. In view of the results so far achieved, the distribution trends of static pressure and velocity vector of central region except the edges of a CFFan are similar regardless of the number of revolution, and an eccentric vortex exists around the bottom blade of a CFFan. Also, a reverse flow is found in the region between stabilizer and CFFan. Moreover, near the edges of a CFFan, an eccentric vortex is separated to two vortexes. Also these vortexes increase the velocity near a rear-guider, and guide the flow near a rear-guider into stabilizer inlet. Therefore, the reverse flow region is formed in the bottom of a CFFan.