• Title/Summary/Keyword: Room Unit

Search Result 703, Processing Time 0.032 seconds

MODULATION OF INTRACELLULAR pH BY $Na^+/H^+$ EXCHANGER AND $HCO_3^-$ TRANSPORTER IN SALIVARY ACINAR CELLS ($Na^+/H^+$ exchanger와 $HCO_3^-$ transporter에 의한 흰쥐 타액선 선세포내 pH 조절)

  • Park, Dong-Bum;Seo, Jeong-Taeg;Sohn, Heung-Kyu;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.352-367
    • /
    • 1998
  • Intracellular pH (pHi) plays an important role in the regulation of cellular processes by influencing the acitivity of various enzymes in cells. Therefore, almost every type of mammalian cell possesses an ability to regulate its pHi. One of the most prominent mechanisms in the regulation of pHi is $Na^+/H^+$ exchanger. This exchanger has been known to be activated when cells are stimulated by the binding of agonist to the muscarinic receptors. Therefore, the aims of this study were to compare the rates of $H^+$ extrusion through $Na^+/H^+$ exchanger before and during muscarinic stimulation and to investigate the possible existence of $HCO_3^-$ transporter which is responsible for the continuous supply of $HCO_3^-$ ion to saliva. Acinar cells were isolated from the rat mandibular salivary glands and loaded with pH-sensitive fluoroprobe, 2', 7'-bis(2-carboxyethyl)-5(6)-carboxyfluorescein(BCECF), for 30min at room temperature. Cells were attached onto the coverglass in the perfusion chamber and the changes in pHi were measured on the iverted microscope using spectrofluorometer. 1. By switching the perfusate from $HCO_3^-$-free to $HCO_3^-$-buffered solution, pHi decreased by $0.39{\pm}0.02$ pH units followed by a slow increase at an initial rate of $0.04{\pm}0.007$ pH units/min. The rate of pHi increase was reduced to $0.01{\pm}0.002$ pH units/min by the simultaneous addition of 1 mM amiloride and $100{\mu}M$ DIDS. 2. An addition and removal of $NH_4^+$ caused a decrease in pHi which was followed by an increase in pHi. The increase of pHi was almost completely blocked by 1mM amiloride in $HCO_3^-$-free perfusate which implied that the pHi increase was entired dependent on the activation of $Na^+/H^+$ exchanger in $HCO_3^-$-free condition. 3. An addition of $10{\mu}M$ carbachol increased the initial rate of pHi recovery from $0.16{\pm}0.01$ pH units/min to $0.28{\pm}0.03pH$ units/min. 4. The initial rate of pHi decrease induced by 1mM amiloride was also increased by the exposure of the acinar cells to $10{\mu}M$ carbachol ($0.06{\pm}0.008pH$ unit/min) compared with that obtained before carbachol stimulation ($0.03{\pm}0.004pH$ unit/min). 5. The intracellular buffering capacity ${\beta}1$ was $14.31{\pm}1.82$ at pHi 7.2-7.4 and ${\beta}1$ increased as pHi decreased. 6. The rate of $H^+$ extrusion through $Na^+/H^+$ exchanger was greatly enhanced by the stimulation of the cells with $10{\mu}M$ carbachol and there was an alkaline shift in the activity of the exchanger. 7. An intrusion mechanism of $HCO_3^-$ was identified in rat mandibular salivary acinar cells. Taken all together, I observed 3-fold increase in $Na^+/H^+$ exchanger by the stimulation of the acinar cells with $10{\mu}M$ carbachol at pH 7.25. In addition, I have found an additional mechanism for the regulation of pHi which transported $HCO_3^-$ into the cells.

  • PDF

THE COMPARATIVE STUDY FOR THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES CURED WITH VARIOUS LIGHT SOURCES (다양한 광원으로 중합한 치과용 접착제의 전단강도에 관한 비교 연구)

  • Choi, Nam-Ki;Cho, Seong-Hoon;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.1
    • /
    • pp.33-41
    • /
    • 2011
  • The objective of this study was to compare the shear bond strengths of five dentin adhesive systems cured with three different light curing sources. Seventy five noncarious permanent teeth were collected and stored in an 0.1% thymol solution at room temperature after extraction. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM) Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL), G-Bond (GB). And three light curing unit systems were used: Elipar Free light 2(LED), OptiLux 501 (Halogen), Flipo (PAC). For the shear bonding test, the labial and lingual surfaces of permanent teeth were used. To obtain a flat dentin surface, the labial and lingual surfaces of the teeth were sanded on SiO2 with number 600 grit and then divided into 15 groups of 10 surfaces each. All samples were theromocycled in water $5^{\circ}C$ and $55^{\circ}C$ for 1000 cycles. The results were as follows: 1. When cured with Freelight 2, the shear bond strength of SM was significantly higher than that of PL, GB (p<0.05), whereas no significant difference was found among those of any other bonding agents. 2. When cured with Optilux 501, the shear bond strength of SM was significantly higher than those of any other bonding agents (p<0.05), whereas no singnificant difference was found among those of andy other bonding agents. 3. When cured with Flipo, the shear bond strength of SM was significantly higher than those of SB, SE, GB (p<0.05), whereas no significant differences was found among those of any other bonding agents. 4. For comparison according to three different light cure unit system, except SB and GB, each three dentin bonding agents showed no significant difference. For SB, only Freelight 2 was significantly higher than the others, with no significant difference between Optilux 501 and Flip. For GB, Statistically significant difference was found only between Freelight and Flipo.

Mid-term results of IntracardiacLateral Tunnel Fontan Procedure in the Treatment of Patients with a Functional Single Ventricle (기능적 단심실 환자에 대한 심장내 외측통로 폰탄술식의 중기 수술성적)

  • 이정렬;김용진;노준량
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.472-480
    • /
    • 1998
  • We reviewed the surgical results of intracardiac lateral tunnel Fontan procedure for the repair of functional single ventricles. Between 1990 and 1996, 104 patients underwent total cavopulmonary anastomosis. Patients' age and body weight averaged 35.9(range 10 to 173) months and 12.8(range 6.5 to 37.8) kg. Preoperative diagnoses included 18 tricuspid atresias and 53 double inlet ventricles with univentricular atrioventricular connection and 33 other complex lesions. Previous palliative operations were performed in 50 of these patients, including 37 systemic to pulmonary artery shunts, 13 pulmonary artery bandings, 15 surgical atrial septectomies, 2 arterial switch procedures, 2 resections of subaortic conus, 2 repairs of total anomalous pulmonary venous connection and 1 Damus-Stansel-Kaye procedure. In 19 patients bidirectional cavopulmonary shunt operation was performed before the Fontan procedure and in 1 patient a Kawashima procedure was required. Preoperative hemodynamics revealed a mean pulmonary artery pressure of 14.6(range 5 to 28) mmHg, a mean pulmonary vascular resistance of 2.2(range 0.4 to 6.9) wood-unit, a mean pulmonary to systemic flow ratio of 0.9(range 0.3 to 3.0), a mean ventricular end-diastolic pressure of 9.0 (range 3.0 to 21.0) mmHg, and a mean arterial oxygen saturation of 76.0(range 45.6 to 88.0)%. The operative procedure consisted of a longitudinal right atriotomy 2cm lateral to the terminal crest up to the right atrial auricle, followed by the creation of a lateral tunnel connecting the orifices of either the superior caval vein or the right atrial auricle to the inferior caval vein, using a Gore-Tex vascular graft with or without a fenestration. Concomitant procedures at the time of Fontan procedure included 22 pulmonary artery angioplasties, 21 atrial septectomies, 4 atrioventricular valve replacements or repairs, 4 corrections of anomalous pulmonary venous connection, and 3 permanent pacemaker implantations. In 31, a fenestration was created, and in 1 an adjustable communication was made in the lateral tunnel pathway. One lateral tunnel conversion was performed in a patient with recurrent intractable tachyarrhythmia 4 years after the initial atriopulmonary connection. Post-extubation hemodynamic data revealed a mean pulmonary artery pressure of 12.7(range 8 to 21) mmHg, a mean ventricular end-diastolic pressure of 7.6(range 4 to 12) mmHg, and a mean room-air arterial oxygen saturation of 89.9(range 68 to 100) %. The follow-up duration was, on average, 27(range 1 to 85) months. Post-Fontan complications included 11 prolonged pleural effusions, 8 arrhythmias, 9 chylothoraces, 5 of damage to the central nervous system, 5 infectious complications, and 4 of acute renal failure. Seven early(6.7%) and 5 late(4.8%) deaths occured. These results proved that the lateral tunnel Fontan procedure provided excellent hemodynamic improvements with acceptable mortality and morbidity for hearts with various types of functional single ventricle.

  • PDF

Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors (악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료)

  • Kwon, Da Eun;Hwang, Ji Hye;Park, In Seo;Yang, Jun Cheol;Kim, Su Jin;You, Ah Young;Won, Young Jinn;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Helmet type bolus for 3D printer is being manufactured because of the disadvantages of Bolus materials when photon beam is used for the treatment of scalp malignancy. However, PLA, which is a used material, has a higher density than a tissue equivalent material and inconveniences occur when the patient wears PLA. In this study, we try to treat malignant scalp tumors by using M3 wax helmet with 3D printer. Methods and materials: For the modeling of the helmet type M3 wax, the head phantom was photographed by CT, which was acquired with a DICOM file. The part for helmet on the scalp was made with Helmet contour. The M3 Wax helmet was made by dissolving paraffin wax, mixing magnesium oxide and calcium carbonate, solidifying it in a PLA 3D helmet, and then eliminated PLA 3D Helmet of the surface. The treatment plan was based on Intensity-Modulated Radiation Therapy (IMRT) of 10 Portals, and the therapeutic dose was 200 cGy, using Analytical Anisotropic Algorithm (AAA) of Eclipse. Then, the dose was verified by using EBT3 film and Mosfet (Metal Oxide Semiconductor Field Effect Transistor: USA), and the IMRT plan was measured 3 times in 3 parts by reproducing the phantom of the head human model under the same condition with the CT simulation room. Results: The Hounsfield unit (HU) of the bolus measured by CT was $52{\pm}37.1$. The dose of TPS was 186.6 cGy, 193.2 cGy and 190.6 cGy at the M3 Wax bolus measurement points of A, B and C, and the dose measured three times at Mostet was $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$ and $195.33{\pm}1.69cGy$. And the error rates were -3.71 %, -4.59 %, and 2.48 %. The dose measured with EBT3 film was $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$ and $196{\pm}2.16cGy$. The error rates were -2.46 %, 0.23 % and 2.83 %. Conclusions: The thickness of the M3 wax bolus was 2 cm, which could help the treatment plan to be established by easily lowering the dose of the brain part. The maximum error rate of the scalp surface dose was measured within 5 % and generally within 3 %, even in the A, B, C measurements of dosimeters of EBT3 film and Mosfet in the treatment dose verification. The making period of M3 wax bolus is shorter, cheaper than that of 3D printer, can be reused and is very useful for the treatment of scalp malignancies as human tissue equivalent material. Therefore, we think that the use of casting type M3 wax bolus, which will complement the making period and cost of high capacity Bolus and Compensator in 3D printer, will increase later.

Implementation of Radiotherapy Educational Contents Using Virtual Reality (가상현실 기술을 활용한 방사선치료 교육 콘텐츠 제작 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.409-415
    • /
    • 2018
  • The development of smart devices has brought about significant changes in daily life and one of the most significant changes is the virtual reality zone. Virtual reality is a technology that creates the illusion that a 3D high-resolution image has already been created using a display device just like it does in itself. Unrealized subjects are forced to rely on audiovisual materials, resulting in a decline in the concentration of practices and the quality of classes. It used virtual reality to develop effective teaching materials for radiology students. In order to produce a video clip bridge using virtual reality, a radiology clinic was selected to conduct two exposures from July to September 2017. The video was produced taking into account the radiology and work flow chart and filming was carried out in two separate locations : in the computerized tomography unit and in the LINAC room. Prior to filming the scenario and the filming route were checked in advance to facilitate editing of the video. Modeling and mapping was performed in a PC environment using the Window XP operating system. Using two leading virtual reality camera Gopro Hero, CC pixels were produced using a 4K UHD, Adobe, followed by an 8 megapixel resolution of $3,840{\times}2,160/4,096{\times}2,160$. Total regeneration time was performed in about 5 minutes during the production of using virtual reality to prevent vomiting and dizziness. Currently developed virtual reality radiation and educational contents are being used to secure the market and extend the promotion process to be used by various institutions. The researchers will investigate the satisfaction level of radiation and educational contents using virtual reality and carry out supplementary tasks depending on the results.

Perceptions of Quality Nursing care of Patients and Families (질적 간호에 대한 환자와 가족의 지각)

  • Chi, Sung-Ai;Kwon, Sung-Bok;Park, Eun-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.4 no.1
    • /
    • pp.247-275
    • /
    • 1998
  • The purpose of this study was to offer the results of content analysis and qualitative study that explored the perceptions about quality nursing care of patients and families as consumers and to identify the implications of this study for quality nursing care management and research. The data was collected from 12 adult patients and 9 families who were admmitted at medical and surgical nursing unit of one university hospital in Seoul from October, 1996 to January, 1997. Research participants were asked to response "what do you think quality nursing care?" and similar questions during the interviews was performed. Data were analyzed using open coding and content analysis with frequencies and percents of attributes of quality nursing care. Attributes of quality nursing care and meaning of quality nursing care that patients and families perceived were explored. 1. The attributes of quality nursing care that patient and families perceived were categorized into 56 attributes. The highest response rate among the attributes was 'one's heart at ease' (76.2%), and the next high response rates were ranked in order 'consideration' , 'care about' (each 61.9% 'expert skill' (57.1%), 'deal with problem promptly' , 'information offer' (42.9%), 'intimate feeling' (38.1%), 'smile' 'service spirit' , 'do one's best' (each 33.3%), 'frequent visit' (23.8%), 'observe the time' (23.8%), 'direct nursing care' , 'speaking warmly' , give a hope' , 'address kindly' , 'a sense of duty' , 'good facilities' (each 19.0%), 'inquire after a patient health' , 'patient-centered nursing care' , 'showing an example' , 'professional knowledge' , 'careless moraly patient' , 'give encourage to patients' , 'good answer a question' (each 14.3%), 'do not imprudently' , 'do not disregard' , 'broad knowledge' , 'emergency treatment skill' , 'dependability' ,'consolation' giving a sense of security' , 'a self sacrificing spirit' , 'a sense of responsibility' 'hard - working', 'enough disposition of nursing staff (each 9.5%), 'improve patient's pride' and the rest attributes exhibited 4.7%, respectively. 2. The attributes that were identified in patients' data only were 8 categories, 'service sprit' (58.3 %) 'expert knowledge' , 'good answer a question' (each 25.0%), 'hard working' (16.7%), 'a warm character', 'professional attainments', 'do without reserve', 'satisfaction' (each 8.3%), 3. The attributes were identified to families' data only were 31 categories, 'speaking warmly' , 'direct nursing care', 'adress kindly', 'patientcentered nursing care', 'showing an example' (each 33.3%). 'do not imprudently' , 'do not disregard' , 'consolation', 'giving a sense of security', 'broad knowledge' , 'emergency treatment skill', 'dependability' ,'a self - sacrificing spirit', 'a sense of responsibility' (each 22.2%), 'improve patient's pride' , 'without discrimination' , 'show kindness' , 'individual nursing care', 'being with patient' , 'helping' , 'accuracy' , 'without any mistake' , 'love' , 'self - confidence', 'self possession', 'a self - denying spirit' , 'a sense of duty' , 'tighten discipline' , 'disposed room with similar patient to diagnosis', 'compensatory relationship between me dical team' , 'role of connection' (each 11.1 %). 4. The attributes of quality nursing care were integrated into 11 categories that they were 'patientcentered nursing care' (25.1%), 'expertise' (22.1%), 'caring'(18.1%), 'kindness'(11.1%L 'nurse attainments(10.1%), 'sincerity' (7.5%), 'good environment' (2.0%), 'effective organizational management', 'coordination', 'enough nursing staff' ( each 1.0%), 'satisfaction' (0.5%) were showed in the order of the highest rate. 5. The concept of quality nursing care were defined as 'give a satisfaction to patients by patientcentered care based on professional skill and caring with kindness and sincerity'. The description of the meaning of quality nursing care provided by this research participants, patients and families can provide important information for quality nursing care management, medical marketing, education and researches of this field. On the basis of the above findings the following recommendations are made: to suggest to utilize this results for patient care in practice setting, development of quality assessment tool in nursing care, repeat study by the same subjects and method, and to a comparative study by the same method to nurse.

  • PDF

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF

The effects of early surfactant treatment and minimal ventilation on prevention of bronchopulmonary dysplasia in respiratory distress syndrome (미숙아 호흡곤란증후군에서 폐표면활성제의 조기 투여와 연성 환기요법이 만성폐질환의 예방에 미치는 영향에 관하여)

  • Park, Jong Jin;Lee, Pil Sang;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.1
    • /
    • pp.44-49
    • /
    • 2009
  • Purpose : Early surfactant treatment and minimal ventilation, bronchopulmonary dysplasia needed prolonged oxygen supplement is a problem. This study aimed to report the effects of early surfactant treatment and minimal ventilation on the prevention of bronchopulmonary dysplasia in respiratory distress syndrome. Methods : We retrospectively studied 139 premature newborn infants (gestational age, 36 weeks; birth weight, 1,500 gm) admitted to the neonatal intensive care unit of Daegu Fatima Hospital between January 2001 and December 2006. We analyzed the occurrence of bronchopulmonary dysplasia with respect to ventilator care and surfactant treatment. Results : The incidence of bronchopulmonary dysplasia was significantly higher with prolonged ventilator care, moderate to severe respiratory distress syndrome, and low Apgar score (P<0.001). Despite early surfactant treatment and minimal ventilation, mild bronchopulmonary dysplasia occurs in a considerable number of patients with mild respiratory distress syndrome. The patient group with low Apgar scores required ventilator care for a prolonged period (P=0.020). Conclusion : Early surfactant treatment and minimal ventilation shortens the duration of ventilator care; however, the preventive effects on bronchopulmonary dysplasia are limited. Therefore, not only early surfactant treatment and minimal ventilation but also appropriate management in the delivery room is essential.

Predictability of Impending Events for Death within 48 Hours in Terminal Cancer Patients (말기암환자에서 임박사건 간 48시간 임종예측도 비교)

  • Hwang, In-Cheol;Choi, Chung-Hyun;Kim, Kyoung-Kon;Lee, Kyoung-Shik;Suh, Heuy-Sun;Shim, Jae-Yong
    • Journal of Hospice and Palliative Care
    • /
    • v.14 no.1
    • /
    • pp.28-33
    • /
    • 2011
  • Purpose: Recognition of impending death is crucial not only for efficient communication with the caregiver of the patient, but also determination of the time to refer to a separate room. Current studies simply list the events 'that have already occurred' around 48 hours before the death. This study is to analyze the predictability of each event by comparing the time length from 'change' to death. Methods: Subjects included 160 patients who passed away in a palliative care unit in Incheon. The analysis was limited to 80 patients who had medical records for the last week of their lives. We determined 9 symptoms and 8 signs, and established the standard of 'significant change' of each event before death. Results: The most common symptom was increased sleeping (53.8%) and the most common sign was decreased blood pressure (BP) (87.5%). The mean time to death within 48 hours was 46.8% in the case of resting dyspnea, 13.6% in the ease of low oxygen saturation, and 36.9% in the case of decreased BP. The symptom(s) which had the highest positive predictive value (PV) for death within 48 hours was shown to be resting dyspnea (83%), whereas the combination of resting dyspnea and confusion/delirium (65%) had the highest negative PV. As for the most common signs before death within 48 hours, the positive PVs were more than 95%, and the negative PV was the highest when decreased BP and low oxygen saturation were combined. The difference in survival patterns between symptoms and signs was significant. Conclusion: The most reliable symptoms to predict the impending death are resting dyspnea and confusion/delirium, and decline of oxygen saturation and BP are the reliable signs to predict the event.

Thrombolytic Therapy for Thrombosis of Prosthetic Mitral Valve - A Case Report - (인공 승모판막에 생긴 혈전의 혈전용해 치료 - 1례 보고 -)

  • Kang, Shin-Kwang;Kim, Si-Wook;Won, Tae-Hee;Ku, Kwan-Woo;Na, Myung-Hoon;Yu, Jae-Hyun;Lim, Seung-Pyung;Lee, Young;Jeong, Jin-Ok
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.826-830
    • /
    • 2002
  • Prosthetic valve thrombosis(PVT) may be a life-threatening complication requiring prompt intervention. This is a case report of thrombolytic therapy for thrombosis of prosthetic mitral valve. A 47 year-old male admitted to the emergency room for abrupt onset of dyspnea. He had undergone mitral valve replacement(On-Ⅹ valve, 29mm) for mitral stenosis 8 months ago. The patient's international normalized ratio(INR) on admission was 1.09. The mechanical clicks were muffled and rales were heard in both lung fields. A transesophageal echocardiography(TEE) revealed prosthetic valve thrombosis with increased transvalvular pressure gradient(34 mmHg). The patient's condition needed to intubation for mechanical ventilation due to hemodynamic compromise, however his wife and relatives refused the surgical intervention due to financial problems. The patient was transferred to the cardiac care unit and we decided to perform thrombolytic therapy. A bolus of 1,500,000 IU of urokinase was given, followed by a drip of 1,500,000 IU for 1 hour. The patient did not improved hemodynamically; therefore, we gave 100 mg of tissue plasminogen activator(t-PA) for over 2 hours. During that time mechanical clicks were audible and hemodynamics of the patient improved progressively. A TEE showed disappearance of thrombus and decreased pressure gradient(1.7 mmHg) after 6 hours of thrombolytic therapy. The patient was recovered without any neurologic sequale and was discharged with administration of warfarin.