• Title/Summary/Keyword: Room Unit

Search Result 701, Processing Time 0.031 seconds

The Analysis of Space in the Multi-housing unit of the Winners in the German architectural competition since 1990 (최근 20년간 독일 공동주택설계경기 당선작의 단위세대 공간 구조 분석)

  • Cho, Ja-Yeon;Choi, Chan-Hwan
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.2
    • /
    • pp.163-173
    • /
    • 2012
  • In this study, the spatial analysis of the multi-housing unit plans was investigated since 1990 for the winners at the architectural competition which was held nationwide in Germany. The investigation was carried out from January in 1990 to December in 2010. 201Unit plans were analyzed. Space syntax model is used as analyzing tool of the Unit plans. The results of the study indicate followings: 1) The interior spaces in 3LDK types and 4LDK types, ordered by high value of integration are; (1) corridor, (2) entrance hall, (3) living room, (4) dining room. 2) The value of integration for the kitchen is higher in L/DK type than in LD/K type, and that for the living room is higher in LD/K type than in L/DK type. The mean value of integration for L/DK type is higher than that for LD/K type. This means that traffic line efficiency of L/DK type is higher than that of LD/K type. 3) The value of integration for corridor and entrance hall is gradually lower in recent years. That is, the type of Unit plans are changing from corridor types to hall types.

  • PDF

The correlation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner (가정용 에어컨 실외기의 기동 소음 분석)

  • Son, Young-boo;Lee, Seung-mock;Ha, Jong-hun;Lee, Byeoung-chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.577-582
    • /
    • 2012
  • Recently, noise reduction of air-conditioner is one of the important design factors for high quality product. Especially, customer complaints arise due to noise problem of the outdoor unit. After the operation of air-conditioner start, noise level of outdoor unit is increased gradually and sometimes abnormal noise occurs until it reaches steady state condition. The aim of this paper is to investigate the relation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner. In order to find out the noise characteristics of outdoor unit, noise and vibration measurements are carried out. Also, the thermodynamic properties of compressor and heat exchanger are measured by using temperature and pressure sensors and experimental results are discussed. Finally, we find out the relation between noise and cycle properties at starting of room air-conditioner and the improvement method to reduce noise level is proposed.

  • PDF

A Study on the Area Composition Analysis of the National Designated Isolation Unit Wards(NDIUs) - Focused on the NDIU wards issued in 2016 (국가지정입원격리병상의 시설별 면적구성에 관한 연구 - 2016년 국가지정입원격리병상 확충사업대상을 중심으로)

  • Yoon, Hyung Jin;Kwon, Soon Jung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.2
    • /
    • pp.73-82
    • /
    • 2017
  • Purpose: Since the facility guidelines for National Designated Isolation Unit wards(NDIUs) had been edited since 2016, all hospital who want to expand or install NDIU should adapt the new guidelines. Instead of providing area requirement, by the way, only essential or optional facility requirements are suggested except patient bedroom in the guidelines. So, as analyze area and area composition of the NDIUs, it could be expected that this study has a role as an area planing reference for not only NDIU but also another airborne infection isolation room. Methods: For the area analysis, 18 sample hospitals are selected among 2016 year applicants. All rooms in NDIUs are grouped as zones whether those are negative air pressurized or not and programed room or not. At the end, area of the zones are summarized and analysed a relationship between area increase and bed number by both correlation analysis and regression analysis. In addition, department usable and gross area per bed, N/G ratio, G/N ratio, and average area ratio of each zone is calculated. Results: First of all, rooms in none negative air pressurized zone of the NDIUs haven't shown a regular installation so that only those in negative air pressurized zone are targeted for the area analysis. Second of all, patient room unit(0.92) and support area(0.79), by correlation analysis, are correlated with total net area. Patient room unit(0.94) and total net area(0.79) are also shown a correlation with bed number. Department usable area($R^2=0.63$, y=36.278x + 102) and patient room unit area($R^2=0.89$, y= 27.993x - 0.8924) has a relationship with bed number by regression analysis. Average N/G is shown as 0.85 and G/N 1.36. Average area ratio of circulation, doffing area, patient room unit, and support area are 25.4%, 9.1%, 50.9%, and 14.6% in order. Implications: This study is a basic research for exploring the NDIUs guidelines to find resonable evidence to develop it for its practical use. Still, it is possibly expected that the guideline is to be developed by post occupancy evaluation in the area of where minimum requirement or facility grade needs to be defined, and by further studies with various perspectives.

A Study on the Planning of the Four-bed room Unit in Public Hospitals (공공병원 4인병실 유니트의 건축계획에 관한 연구)

  • Chai, Choul Gyun;Choi, Kwangseok;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.19 no.3
    • /
    • pp.41-52
    • /
    • 2013
  • Purpose: This paper tries to set up the design guidelines for the 4 bedroom in Public Hospital wards as the standard multi-bed room in order to upgrade the bedroom environment, increase inpatients' and nurses' satisfaction level, and decrease cross infection possibility. Methods: Literature survey containing legal standards related to hospital bedrooms in Korea, Japan and Germany have been conducted. Questionnaires have been distributed to inpatients and nurses in 39 Public Hospital, and face to face talk with ward nurses in 9 Public Hospitals have been conducted. Thereafter 10 architectural drawings, 28 questionnaires from nurses and 544 questionnaires from inpatients have been analysed. Results: This article suggests some design guidelines and example drawings of standard 4 bedroom unit in Public Hospital. Implications: The result of this research would be useful as a reference when the architect tries to design a Four-bed room unit in Hospitals.

Changes in Apartment Unit Plan Caused by the Revision of Regulations for Area Calculating Criteria and Balcony Use - Focused on Changes of Size of Rooms in 60 m2 and 85 m2 Sized Unit - (전용면적 산정기준 변화와 발코니 용도변환 허용이 아파트 단위주거 평면설계에 미친 영향 - 전용면적 60 m2와 85 m2 평면의 실별 규모 변화를 중심으로 -)

  • Park, In-Seok;Park, No-Hak;Chun, Hyun-Sook
    • Journal of the Korean housing association
    • /
    • v.25 no.2
    • /
    • pp.27-36
    • /
    • 2014
  • The revision of regulations for apartment unit design, which are concerning the area calculating criteria (revised in 1998) and use of balcony (revised in 2005), considerably have increased livable space of apartment unit. This paper aims to verify its effect to apartment unit plan in the aspect of number of rooms and size of each room. For this purpose, 60 and 85 $m^2$ sized apartment unit plans in Seoul Gangnam district have been analysed by construction period, and a conclusion is drawn out as following; (1) The revison of regulations in 1998 and 2005 increased livable space of 60 and 85 $m^2$ sized apartment about 16.4~20.6 $m^2$ area. (2) Bedrooms, living room, dining room and kitchen have no change in size in nominal sense, actually, they increase their size after the fact by converting balcony to livable space. (3) Bathroom, dress room and entrance space have been considerably increased in size, which is possible for available area added in place of wall footprint according to 1998 revision.

A Study on the Spatial Characteristics of the Multi-housing Units in Seoul and Kyung-gi Area - Focused on the Unit Size of over $165m^2$- (최근 분양된 수도권 공동주택 단위세대의 공간계획 특성에 관한 연구 - 전용면적 $165m^2$ 이상의 대형규모를 중심으로 -)

  • Kim, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.6
    • /
    • pp.116-124
    • /
    • 2007
  • The purpose of this study is to find out the spatial characteristics of the multi-housing units in Seoul and Kyung-gi area since 2006. Literature review and content analysis were used for this study and 82units of the big size over $165m^2$ were analyzed to review such design characteristics as spatial composition, layout and linkage. Through this study, the following conclusions have been reached; 1) Most unit plans had 4LDK and 3bath types including family room as a public space. This results shows that family-room and bathroom has recently become more important than number of rooms in multi-housing units planning. 2) Diversity of plan figures such as mass-mixing, mass-separation and polygons(L, V-type)was showed in most unit plan, breaking from the standardized forms of box types. 3) Intermediated spaces such as foyers and halls in entrance zone were planned and sub-entrance into kitchen were planned for the various types of circulation and work-efficiency. Cases had private space separated from public space, the dispersion of rooms with the increase of connection by corridors, L-DK meaning the living room isolated from the dining and kitchen, partially located living room for a view in area distribution. The spatial planning of master-zone mostly consists of the types of two-rooms and an entry into a foyer(library, dress-powder room, bathroom and master bedroom). This study has a significant meaning on grasping current trend in Korean multi-housing and to provide information for future direction on housing-unit design.

A Study on Statistical Characteristics of Space Dimension of 60 m2, 85 m2 Size Apartment Plan Types in Seoul (전용면적 60 m2, 85 m2 아파트 평면 유형에서 실 치수의 통계적 특성에 관한 연구)

  • Kim, Min-Kyoung;Yoon, Chae-Shin
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.53-65
    • /
    • 2010
  • Apartment buildings represent the most typical patterns of housing in Korea. The present plans are very different from the previous ones when they appeared for the first time. Although apartment unit plans has changed drastically, they can be classified into several categories. Apartment unit plans reflects the demands of living activities and space dimensions of unit plans have the characteristics of diachronic continuity and carry the values of living culture. Thus this study aims to provide the statistical dimensional data of each room that can be actually used for the design of unit plans by sub-grouping typical unit plans. The statistical data of this study showed that apartment unit plans are shifting from 2bay/3room type to 3bay/3room type in 1990s. It is very peculiar that the typical unit plan of $60\;m^2$ area becomes to resemble that of $85\;m^2$ area. The space arrangement of typical unit plans of both $60\;m^2$ and $85\;m^2$ area is almost identical while only their space dimensions differ slightly. As the mean/mode/median values of space dimensions in a typical unit plan are converging into a range of narrow margin, space dimensions of typical unit plan are contended to be strictly regular. The statistical numeric data of various space dimensions provided in this paper can be applied practically to the design of apartment unit plans for low income class people who are disprivileged in the society.

Dementia Units' Architectural Features in the Metropolitan Area (수도권 치매요양시설의 건축적 특성)

  • Cho Young-Hang;Lyou Joung-Woo
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.15-24
    • /
    • 2006
  • The purpose of this study is to unveil the characteristics of residential space organizations in dementia units. Observation, interview, and drawing analysis of the sample units were used to collect the data for new dementia unit plans. The findings revealed the lack of minimum requirement of residential spaces per person in some sample units, the necessity of consideration of group units, and the change of units based plans to each floor based plans. However, insufficient recreation rooms and the lack of caregivers' resting spaces in the sample units were uncovered. Thus, various recreation rooms such as a reading room, flower room, pottery room, bakery room, or game room should be provided in the sample units. The conclusion is that asylum oriented residential types should be changed to each floor based units having privacy and high satisfaction of residential life. The study of floor oriented residential units focusing on minimum spaces of the floor, space numbers, number of elderly persons on each floor should be studied in the near future.

The Impact of Safety Climate and Fatigue on Safety Performance of Operating Room Nurses (수술실 간호사의 안전분위기와 피로 수준이 안전이행에 미치는 영향)

  • Choi, U-Eun;Kim, Hyun-Young
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.22 no.5
    • /
    • pp.471-479
    • /
    • 2016
  • Purpose: This study was conducted to evaluate the level of safety climate, fatigue, and safety performance and to identify the impact of safety climate and fatigue on the safety performance of operating room nurses. Methods: The study design was a descriptive survey. Participants were 174 operating room nurses from two general hospitals and two university hospitals in S and D cities. Three structurally designed questionnaires were used to evaluate their safety climate, fatigue, and safety performance. Collected data were analyzed using descriptive analysis, t-tests, ANOVAs, Pearson correlation coefficient, and stepwise multiple regression. Results: Safety performance of operating room nurses had a mean of 3.26 on a 5-point scale. 'Current department career'(${\beta}=.17$, p=.006) and 'safety climate (work-unit contribution) (${\beta}=.63$, p<.001) accounted for 39% of the variance in operating room nurses' safety performance. Conclusion: Findings indicate that work-unit contribution towards safety climate is an important factor in increasing operating room nurses' safety performance. Therefore, it is essential to find motivational properties consistent with the characteristics of the operating room environment.

A study on DCGL determination and the classification of contaminated areas for preliminary decommission planning of KEPCO-NF nuclear fuel fabrication facility

  • Cho, Seo-Yeon;Kim, Yong-Soo;Park, Da-Won;Park, Chan-Jun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1951-1956
    • /
    • 2019
  • As a part of the preliminary decommissioning plan of KEPCO-NF fuel fabrication facility, DCGLs of three target radionuclides, 234U, 235U, and 238U, were derived using RESRAD-BUILD code and contaminated areas of the facility were classified based on contamination levels from the derived DCGLs. From code simulations, one-room modeling results showed that the grinding room in building #2 was the most restrictive (DCGLgross = 10493.01 Bq/㎡). The DCGLgross results in contaminated areas from one-room modeling were slightly more conservative than three-room modeling. Prior to the code simulation, field survey and measurements conducted by each survey unit. For a conservative approach, the most restrictive DCGLgross in each survey unit was taken as a reference to classify the contaminated areas of the facility. Accordingly, seven rooms and 37 rooms in the nuclear-fuel buildings were classified as Class 1 and Class 2, respectively. As expected, fuel material handling and processing rooms such as the grinding room, sintering room, compressing room, and powder collecting room were included in the Class 1 area.