• 제목/요약/키워드: Room Unit

검색결과 702건 처리시간 0.028초

LNG 냉열을 이용하는 동력사이클 열역학 해석 (Thermodynamic Analysis of Power Generation Cycle Utilizing LNG Cold Energy)

  • 최권일;장홍일
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권1호
    • /
    • pp.48-55
    • /
    • 1999
  • thermodynamic cycle analysis has been performed for the power generation systems to utilize the cold energy of liquefied natural gas (LNG). The power cycle used the air or water at room temperature as a heat source and the LNG at cryogenic temperature as a heat sink. Among manypossible configurations of the cycle. the open Rankine cycle. and the closed Brayton cycle, and the closed Rankine cycle are selected for the basic analysis because of their practical importance. The power output per unit mass of LNG has been analytically calculated for various design parameters such as the pressure ratio. the mass flow rate. the adiabatic efficiency. the heat exchanger effectiveness. or the working fluid. The optimal conditions for the parameters are presented to maximize the power output and the design considerations are discussed. It is concluded that the open Rankine cycle is the most recormmendable both in thermodynamic efficency and in practice.

  • PDF

A New Address-While-Display Driving Method using the $\underline{S}hort\;\underline{R}amp\;\underline{R}eset$ Pulse (SRR) for High Contrast ratio and Wide Address Margin

  • Jung, Jae-Chul;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.631-634
    • /
    • 2005
  • We propose a new address-while-display (AWD) driving method to obtain a high contrast ratio and a wide driving margin which is composed of a short ramp reset period, a sustain period and an address period as the basic unit. The short ramp reset (SRR) pulse made it possible to assure the wide operating voltage margin and minimize the background luminance by redistributing the wall charges between address and scan electrode. As a result, a high dark room contrast ratio of 10000 to 1 could be obtained with a wide operating voltage margin of 40V for stable address.

  • PDF

횡류팬 흡입구의 위치가 성능 및 소음 특성에 미치는 영향 (The Influence of the Intake Regions of the Cross-flow fan on the Performance and Fan Noise)

  • 김진백;최원석;이재권
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.78-82
    • /
    • 2004
  • The cross-flow fan which is used for air-conditioner indoor units were studied experimentally. The recent trend shows that the room air-conditioners need to be good-looking. According to the visual design concepts the intake regions of the fan can vary, which leads to the loss of the performance and the increase of the noise of the fan. In order to optimize the performance of the fan and minimize the aerodynamic noise for the system, the performance characteristics and the noise of the cross-flow fan have been investigated at the various conditions of the intake region of the unit.

  • PDF

고속버스의 환기구 형태에 따른 환기량 분석 (Analysis on the Ventilation Rate of Express Bus according to the Geometry of Vent)

  • 신인환;유호천
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.174-178
    • /
    • 2011
  • This paper deals with the free cooling system of express bus using natural energy source in order to improve the room air quality and save cooling energy. In an express bus, there are may passengers in unit area, requiring the improvement of air quality and giving higher energy saving efficiency. Particularly, the express buses running fast make it easy to take in outdoor air at a flow rate controllable with a damper mechanism. This paper proposes the analysis on the air flow achieved by a damper controlled vertically and horizontally in order not to deteriorate the ride comfort of the passengers.

  • PDF

Determination of Low-temperature Electrochemical Properties of Selected Cation-exchange Membranes for Cathodic Protection Analysis

  • Ko, Moon-Young;Kwon, Byeong-Min;Hong, Byung-Pyo;Byun, Hong-Sik
    • Korean Membrane Journal
    • /
    • 제10권1호
    • /
    • pp.8-12
    • /
    • 2008
  • The electrochemical properties of Nafion type membranes as a function of temperature to examine the key factors affecting the cathodic protection process at low temperatures was investigated in this study. Variable temperature experiments for AC impedance, DC resistance were conducted. The resistances of 3 Nafion membranes (N 324, N 450, N MAC) were measured in 30% KOH (aq) for a range of temperatures between $-30^{\circ}C$ and room temperature. Membrane resistance increases exponentially with decreasing temperature. This behaviour is most significant at operational temperatures below $0^{\circ}C$. These membranes are stable under the low temperature and caustic conditions of the heat exchange system, but they place a much higher restriction on the cathodic protection of the stainless heat exchange stack. N 450 has the lowest AC impedence and DC resistance at temperatures below $0^{\circ}C$ and consequently is most suitable membrane of the three, for low temperature applications.

그래프 기법에 의한 서울시 아파트 평면분석에 관한 연구 (An Analysis of the Apartment House Plans in Seoul by Means of a New Graph-theoretic Method)

  • 서경욱
    • 한국주거학회논문집
    • /
    • 제18권2호
    • /
    • pp.121-128
    • /
    • 2007
  • The investigation of the apartment housing as a dwelling type has become the most important and popular research subject to understand the housing culture in Korea. In their methods of typological analysis, it is found that most studies represent each unit plan as a simplified architectural drawing. This type of typology, however, has difficulties in processing a large scale of data set because each representation of a plan contain too many informations. To deal with this problem, this study suggests a new graph-theoretical method by which apartment plans can be represented in a more simple and effective way. This new method is also tested against the sample plans from Gangnam-gu area in Seoul to reveal the design logic hidden in plan configuration. Through a series of analyses, it is verified that there exist a design strategy that guides the particular pattern of zoning and allocation of each room in the plan.

전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구 (An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger)

  • 장영근
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

매크로 모델에 의한 실내온열환경 검토 (An Analysis of Indoor Thermal Environment by Macro Model)

  • 정재훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.584-589
    • /
    • 2008
  • It is known that slab thermal storage which uses concrete slab as thermal material is effective in the load leveling and using the nighttime electric power. The temperature distribution is not constant in plenum in thermal storage time by beams, ducts such as several factor. It is considered that this fact will effect on efficiency of thermal storage and indoor thermal environment. The purpose of this paper is to examine the thermal environment inside plenum. A macro model was made for the analysis of indoor thermal environment as the first step. The flow rate distribution and temperature distribution of object room model was examined by use of basic equations such as airflow by the pressure difference between unit cells, heat flow by air and heat transfer.

  • PDF

Design of Window Applicable Blind-type Frequency Selective Surface

  • Lee, In-Gon;Hong, Ic-Pyo
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.682-685
    • /
    • 2014
  • In this paper, we presented the window applicable blind-type frequency selective surface to control the coverage area of wireless communication in secure building or conference room. The proposed frequency selective structure has the reconfigurable frequency range depends on its blind rotation angle. To verify the proposed structure, we fabricated the window blind-type frequency selective surface with four-legged loaded element and ring-type element as a unit cell and performed measurements of the transmission characteristics for different blind rotation angles to prove the feasibility. The measurement results show good agreements with the simulation results. One of the advantages is that the proposed structure does not need to have a bias circuit, so it is very easy to implement at low cost and also can be applied to any planar surface for wireless security applications.

Chemical Preparation of Barium-Strontium Titanate

  • 노태용;김승원;이철
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권12호
    • /
    • pp.1180-1184
    • /
    • 1995
  • The precursors of Ba1-xSrxTiO3(x=0.0-0.3) were prepared by the rapid addition of aqueous solution of titanyl oxalate to the mixed aqueous solution of barium and strontium at room temperature. The optimum pH was theoretically calculated from the equilibrium constants and solubility products. The chemical formula of the precursors obtained corresponded to Ba1-xSrxTiO(C2O4)2·4H2O(x=0.0-0.3) as determined by thermal gravimetric analysis. The precursors were converted to stoichiometric Ba1-xSrxTiO3(x=0.0-0.3) with a particle size of 0.01-0.04 μm. As increasing the amount of strontium substituted to barium sites, the structure of crystal changed from the tetragonal phase to the cubic and the unit cell volume was decreased.