• 제목/요약/키워드: Room Temperature

검색결과 8,217건 처리시간 0.036초

퍼지논리를 이용한 저온저장고의 온도제어시스템 개발 (Development of Temperature Control System for Cold Storage Room Using Fuzzy Logic)

  • 양길모;고학균;조성인
    • Journal of Biosystems Engineering
    • /
    • 제25권2호
    • /
    • pp.107-114
    • /
    • 2000
  • Low temperature storage method is to increase the value of agricultural products by reducing quality loss and regulate consignment time by controlling respiration rates of agricultural products. Respiration rate of agricultural products depends on several factors such as temperature, moisture, gas composition and a microbe inside the storage room. Temperature is the most important factor among these, which affects respiration rate and causes low or high temperature damage. Fuzzy logic was used to control the temperature of a storage room ,which uses information of uncertain facts and mathematical model for room temperature control . Room temperature was controlled better by using fuzzy logic control method rather than on-off control method. Refrigerant flow rates and temperature deviations were measured for on-off system using TEV(temperature expansion valve) and for fuzzy system using EEV(Electrical Expansion Valve) . Temperature of the Storage room was lowered faster by using fuzzy system than on -off system. Temperature deviation was -0.6~+0.9$^{\circ}C$ for on-off system and $\pm$0.2$^{\circ}C$ for fuzzy system developed. Temperature deviation and variation of temperature deviation were used as inout parameters for fuzzy system. The most suitable input and output value were found by experiment. Cooling rate of the storage room decreased while temperature deviation increased for the sampling time of 20 sec.

  • PDF

상온 강자성 (Ga,Mn)N 박막을 이용한 질화물계 스핀 발광소자의 스핀편극된 빛의 발광 (Emission of Spin-polarized Light in Nitride-based Spin LEDs with Room-temperature Ferromagnetic (Ga,Mn)N Layer)

  • 함문호;명재민
    • 한국전기전자재료학회논문지
    • /
    • 제18권11호
    • /
    • pp.1056-1060
    • /
    • 2005
  • We investigated the fabrication and characteristics of the nitride-based spin-polarized LEDs with room-temperature ferromagnetic (Ga,Mn)N layer as a spin injection source. The (Ga,Mn)N thin films having room-temperature ferromagnetic ordering were found to exhibit the negative MR and anomalous Hall resistance up to room temperature, revealing the existence of spin-polarized electrons in (Ga,Mn)N films at room temperature. The electrical characteristics in the spin LEDs did not degraded in spite of the insertion of the (Ga,Mn)N layer into the LED structure. In EL spectra of the spin LEDs, it is confirmed that the devices produce intense EL emission at 7 K as well as room temperature. These results are expected to open up new opportunities to realize room-temperature operating semiconductor spintronic devices.

변형률속도를 고려한 상온 나노임프린트 공정의 유한요소해석 (Finite Element Analysis of the Room Temperature Nanoimprint Lithography Process with Rate-Dependent Plasticity)

  • 송정한;김승호;;허훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.63-66
    • /
    • 2005
  • Nanoimprint lithography (NIL) process at room temperature has been newly proposed in recent years to overcome the shape accuracy and sticking problem induced in a conventional NIL process. Success of the room temperature NIL relies on the accurate understand of the mechanical behavior of the polymer. Since a conventional NIL process has to heat a polymer above the glass transition temperature to deform the physical shape of the polymer with a mold pattern, viscoelastic property of polymer have major effect on the NIL process. However, rate dependent behavior of polymer is important in the room temperature NIL process because a mold with engraved patterns is rapidly pressed onto a substrate coated with the polymer by the hydraulic equipment. In this paper, finite element analysis of the room temperature NIL process is performed with considering the strain rate dependent behavior of the polymer. The analyses with the variation of imprinting speed and imprinting pattern are carried out in order to investigate the effect of such process parameters on the room temperature NIL process. The analyses results show that the deformed shape and imprint force is quite different with the variation of punch speed because the dynamic behavior of the polymer is considered with the rate dependent plasticity model. The results provide a guideline for the determination of process conditions in the room temperature NIL process.

  • PDF

에테폰 처리가 자두과실의 성숙과 수확후 유통방법이 품질에 미치는 영향 (Effect of ethphon treatment on the maturation of Plum fruits(Prunus salisina) and changes of the quality as affected by storage conditions)

  • 임병선;이종석
    • 한국식품저장유통학회지
    • /
    • 제3권2호
    • /
    • pp.155-170
    • /
    • 1996
  • In order to determine the physiolosical characteristics of plum fruits(Oishi wase) during maturation and guilty according to temperature after harvest, (2-chloroethyl) phosphonic acid(ethphon) 390ppm was sprayed on plum tree 11days before commercial matuarity in Suwon area. And also this study was acted to investigate fruits quility(Formosa) influenced by temperature(room, low) and polyethylene films(0.03, 0.06, 0.1mm), 1. Effect of ethphon on the fruits maturation and fruits(Oishi wase) quility according to temperature ofter harvest. Ethephon stimulated fruits ripening but the firmness was reduced rapidly. Soluble solids and titratable acidity was not very different than each treatment. Carbon dioxide and ethylene production were advanced and the production peak were shown earlier by ethephon treatment as compared with control fruit. Anthocyanin development was enhansed rapidly by ethephon treatment but it exerted a bad influence on fruits color after harvest, The soluble sugars in fluits were mainly glucose, sucrose, and fructose. Those content were higher in treated fruit than control. The organic acid was mainly malic acid. The shelf life was less than about 5days at room temperature and about 10 days at low temperature. 2. Fruits(Formosa) quility as affected by polyethylene film bagging. The polyethylene films well maintained the firmness both room and low temperature. Low temperature was more effective in maintaining titratable acidity than room temperature, especially polyethylene films. On the Other hand, soluble solids content was not shown wide differance between room and low temperature. Polyethylene film showed a high resperation rate, the rate was higher at room temperature than low temperature and thicker films revealed higher rate. Otherwise, ethylene production was low in all treatment Polyethylene film inhibited the coloration of fruits, decreased anthocyanin content. Fruits coloration delayed by low temperature in control. The shelf life of plum fruits was about 6 days at room temperature and 13 days at low temperature in control Polyethylene film had no advantage on shelf life both at room and low temperature.

  • PDF

초고집적회로의 커패시터용 PZT박막의 입열 조건에 따른 유전특성 -1- 비정질 PZT를 사용한 PZT 박막의 누설전류 개선에 관한 연구 (Dielectric properties with heat-input condition of PZT thin films for ULSI's capacitor -1- A study on the improvement of leakage current of PZT thin films using a amorphous PZT layer)

  • 마재평;백수현;황유상
    • 전자공학회논문지A
    • /
    • 제32A권12호
    • /
    • pp.101-107
    • /
    • 1995
  • To improve the leakage current, we developed two step sputtering method where PZT thin film in first deposited at room temperature followed by 600.deg. C deposition. The method used an amorphous PZT layer deposited at room temperature to keep a stable interface during sputtering at high temperature. PZT thin films were deposited on Pt/Ti/SiO$_{2}$/Si substrate at room temperature and 600.deg. C sequentially. The effect of the layer deposited at room temperature was investigated with regard to I-V characteristics and P-E hysteresis loop. In the case of the sample with the layer deposited at room temperature, both leakage current and dielectric constant were decreased. The thicker the layer deposited at room temperature was, the lower dielectric constant was. However, leakage current was indepenent of the variation of the thickness ratio. The sample with 200$\AA$ of the layer deposited at room temperature showed the most promising results in both dielectric constant and leakage current.

  • PDF

Cortisol, $25OHD_3$ 추출 후 원심 분리시 온도가 검사결과에 미치는 영향 (Effect of the Centrifugation Temperature on Cortisol, $25OHD_3$ Values After Extraction)

  • 김외정;천준홍;유선희;조시만
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.143-146
    • /
    • 2009
  • Purpose: We use the centrifugation of refrigeration state in separation of blood serum, Anti-ds-DNA, Vitamin $B_{12}$/Folate and GAD-Ab assay. However, Cortisol urine and 25-Hydroxyvitamin $D_3$ ($25OHD_3$) are conducted centrifuge at room temperature. This is troublesome that change centrifugation temperature into room temperature due to using of most assays at cold temperature. Therefore when using centrifuge after extraction of Cortisol urine and $25OHD_3$, we conducted researches on effect of the centrifugation temperature in assay results. Materials and Methods: In Cortisol urine, add dichloromethane 1.0 mL in urine $500\;{\mu}L$, mix for 15 minutes, and then centrifuge for 8 minutes at 2600rpm. In $25OHD_3$ add acetonitrile 0.5 mL in serum $200\;{\mu}L$, and then centrifuge for 8 minutes at 2600rpm. Those experiments were conducted centrifuge at room temperature and $4^{\circ}C$. And experiments conducted immediately after centrifugation at $4^{\circ}C$ and standing for 20 minutes after centrifugation $4^{\circ}C$. Results: In Cortisol urine, room temperature result in 1.93, 2.18, 2.43, 9.45, 14.2 (${\mu}g/dL$). Experiments of performing immediately after centrifuge at $4^{\circ}C$ result in 1.8, 2.0, 2.3, 8.1, 13.7 (${\mu}g/dL$). Experiments of performing after 20 minutes result in 2.1, 2.1, 2.7, 9.95, 14.35 (${\mu}g/dL$). On the other hand, the $25OHD_3$ tests conducted at room temperature result in 7.13, 26.6, 35.8, 48.2, 74.8 (ng/dL). Experiments were conducted immediately by pipetting after $4^{\circ}C$ centrifugation result in 7.53, 30.9, 40.3, 61.5, 89.1 (ng/dL) as results are higher than experiments at room temperature. The experiments that conducted centrifuge at $4^{\circ}C$ and then left at room temperature for 20 minutes result in 7.40, 32.4, 41.3, 51.6, 85.6 (ng/dL). Conclusions: Experiments were conducted by using centrifuge at $4^{\circ}C$ are higher or lower than room temperature. The differences between results of standing for 20 minutes after centrifuge at $4^{\circ}C$ and those of centrifuge at room temperature are less than conducting immediately. It is concerned that experiments conducted immediately after centrifuge at $4^{\circ}C$ are incorrect, because tubes become dim due to temperature differences between $4^{\circ}C$ and room temperature. Therefore, it is desirable to centrifuge at room temperature as manual and we should pipet promptly without stopping.

  • PDF

Design of Semiconducting Gas Sensors for Room-Temperature Operation

  • Song, Young Geun;Kim, Gwang Su;Ju, Byeong-Kwon;Kang, Chong-Yun
    • 센서학회지
    • /
    • 제29권1호
    • /
    • pp.1-6
    • /
    • 2020
  • Gas sensors that operate at room temperature have been extensively studied because of sensor stability, lift time, and power consumption. To design effective room-temperature gas sensors, various nanostructures, such as nanoparticles, nanotubes, nanodomes, or nanofibers, are utilized because of their large-surface-to-volume ratio and unique surface properties. In addition, two-dimensional materials, including MoS2, SnS2, WS2, and MoSe, and ultraviolet-activated methods have been studied to develop ideal room-temperature gas sensors. Herein, a brief overview of state-of-the-art research on room-temperature gas sensors and their sensing properties, including nanostructured materials, two-dimensional materials, the ultraviolet-activated method, and ionic-activated gas sensors, is provided.

숙성온도가 된장의 품질에 미치는 영향 (Effect of Fermentation Temperature on Quality of Doenjang)

  • 김문석;김은미;장규섭
    • 농업과학연구
    • /
    • 제35권1호
    • /
    • pp.1-9
    • /
    • 2008
  • 메주를 만들 때 저온숙성의 경우 상온숙성보다 발효 특성과 관련이 있는 pH, 아미노산성 질소 등의 양이 낮았으며 동일한 아미노태 질소 함량에 도달하기까지 숙성기간이 약 2~3배정도 필요한 것으로 나타났고, 된장의 색상이 약 2배정도 밝은 것으로 나타났다. 그리고 숙성초기 낮은 온도로 인해 산성생균의 활동성이 낮아지고 이로 인한 유기산 생성량이 낮아져 상온숙성 된장에 비해 pH가 높고, acidity I이 낮으며, 저온숙성된장은 가수분해 효소에 의한 분해속도의 저하로 낮은 아미노산성 질소 함량을 보였다.

  • PDF

마늘(Allium sativum L.)의 생화학적 변화에 대한 저장 및 유통조건의 영향 (Effect of Storage and Marketing Condition on Biochemical Property Changes of Garlic (Allium sativum L.))

  • 최선태;장규섭
    • 한국식품저장유통학회지
    • /
    • 제5권2호
    • /
    • pp.111-117
    • /
    • 1998
  • Biochemical property changes of garlic during various storages and marketing after storage were investigated. Content of enzymatic pyruvic acid increased by room and low temperature storage but decreased by CA and MA storage. Fructan contents decreased rapidly by low temperature storage, but restrained decrement by CA and MA storage. Free sugar increased during storage, but did slowly by room temperature storage. Green pigment development was observed when garlics stored for 90days at low temperature were processed into crushed form. This discoloration was small for garlics stored in CA and MA, and never occurred for room temperature stored garlics. When marketed after storage, content of enzymatic pyruvic acid decreased in garlic stored in room and low temperature storage, but increased in garlics which decreased during CA and MA storage. Fructan contents deceased but free sugar contents continuously increased with marketing period. Green pigment development decreased in crushed garlic after 30days at room temperature marketing, but increased in low temperature marketing with marketing time progress.

  • PDF

Fe-Aluminide합금의 미세조직과 기계적 특성에 관한 연구 (A Study on the Microstructure and Mechanical properties of Fe Aluminide alloys)

  • 조종춘;이도인;이성재;최병학;김학민
    • 연구논문집
    • /
    • 통권22호
    • /
    • pp.115-125
    • /
    • 1992
  • Mechanical properties and microstructure were investigated on vacuum induction melted $Fe_3A1$base alloys of $DO_3$ structure. Specal emphasis were put on the effect of alloy chemistry, grain size and process(rolling, directional solidification) on mechanical properties of Fe-22.5-39at.%Al at elevated temperature between room temperature and $800^{\circ}C$. grain size of as-cast alloys is refined by rolling from 1mm to $80\mum$. Tensile strength of Fe-24.lat.%AI was about 404MPa at the critical ordering temperature, and the fracture strain of the alloy was 1-2% at room temperature. An inverse temperature dependence of the strength is noticed as-cast $Fe_3A1$. The presence of Cr and Zr do not affect the room temperature ductility and high temperature strength. Fracture strain of directionally solidified(DS) $Fe_3A1$ is about 1%at room temperature, but is about 60%at. $T_C$(550^{\circ}C)$. Tensile strength of DS alloy is lower than that of as-cast alloy at $530^{\circ}C$ and $430^{\circ}C$. Failure mode at room temperature varies from transgranular fracture to intergranular fracture with the addition of Al. the failure mode also varies from mixed(transgranular+ intergranular) mode between room temperature and $500^{\circ}C$ to intergranular mode above $550^{\circ}C$

  • PDF