• 제목/요약/키워드: Rod instrumentation

검색결과 35건 처리시간 0.025초

Short Segment Anterior Correction of Adolescent Idiopathic Scoliosis

  • Han, In-Ho;Chin, Dong-Kyu;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권1호
    • /
    • pp.52-56
    • /
    • 2008
  • Objective : The purpose of this study was to introduce our surgical experiences of scoliosis and to evaluate the effectiveness of anterior correction and fusion in adolescent idiopathic scoliosis (AIS). Methods : Between August 2004 and August 2007, four patients with AIS were treated with anterior segmental fusion and fixation at our hospital. Mean follow-up period was 9 (6-12) months. The average age was 14.0 (13-15) years. According to Lenke classification, three patients showed Lenke 1 curve and one patient with Lenke 5 curve. Single rod instrumentation was performed in one patient, dual rod instrumentation in one patient and combined rod instrumentation in two patients. Coronal Cobb measurements were performed on all curves in thoracic, thoracolumbar and, lumbar spine and the angle of hump was measured by a scoliometer pre- and postoperatively. Results : The average operative time was 394 minutes (255-525) with an average intraoperative blood loss of 1,225 ml (1,000-1,700). The mean period of hospital stay was 19.3 days and there was no complication related to the surgery. The mean Cobb angle was reduced from $43.3^{\circ}$ to $14.8^{\circ}$ (65.8% correction) postoperatively and the rib hump corrected less than $5^{\circ}$. All patients and their parents were satisfied with the deformity correction. Conclusion : Anterior spinal correction and fusion of AIS with Lenke 1 and 5 curve showed excellent deformity correction without any complications. In particular, we recommend anterior dual rod instrumentation because of mechanical stability, better control of kyphosis, and a higher fusion rate.

유한요소 모델을 이용한 척추 측만증 교정 시 교정 기구에 따른 효과 분석 (Analysis of Scoliosis Correction Effects according to Instrumentation Devices using a Finite Element Model)

  • 김영은;손창규;이광희;최형연;이춘기
    • 한국정밀공학회지
    • /
    • 제21권8호
    • /
    • pp.157-163
    • /
    • 2004
  • Scoliosis is a complex musculoskeletal dieses requiring 3-D treatment with surgical instrumentation. To investigate the effects of correction surgery, a finite element model of personalized model of the scoliotic spine that will allow the design of clinical test providing optimal estimation of the post-operation results was developed. Three dimensional skeletal parts, such as vertebrae, clavicle and scapular were modeled as rigid bodies with keeping their morphologies. Kinematical joints and spring elements were adapted to represent the inter-vertebral disc and ligaments respectively. With this model, two types of surgery procedure, distraction procedure with Harrington device and rod derotation procedure with pedicle screw and rod system had been carried out. The obtained simulation results were comparatively corresponding to the post operational outcomes and successfully demonstrated qualitative analysis of surgical effectiveness. From this analysis, it has been found that the preparing of appropriate rod curvature and its insertion was more important than just performing the excessive derotation for scoliosis correction.

Simulation of magnetostrictive Terfenol-D rod dynamics using a coupled FE-BEM

  • 장순석
    • 센서학회지
    • /
    • 제8권4호
    • /
    • pp.298-307
    • /
    • 1999
  • This paper describes the application of the coupled FE-BEM (finite element-boundary element method) for the numerical harmonic analysis of the linear dynamic behaviour of a magnetostrictive Terfenol-D rod in water. The magnetostrictive rod is three-dimensionally simulated to transduce applied electric current in a helical coil around the rod to mechanical displacement. The theoretical derivation of the magnetostrictive matrix equation is described in detail. The steady-state resonance response of the displacement is shown. In addition, the directivity pattern and the radiation impedance are also shown.

  • PDF

핵연료 계장을 위한 천공조건에 대한 실험적 연구 (An Experimental Study on Drilling Conditions for the Instrumentation of Nuclear Fuel)

  • 홍진태;김가혜;정황영;안성호;정창용
    • 한국정밀공학회지
    • /
    • 제30권1호
    • /
    • pp.113-119
    • /
    • 2013
  • To develop a new nuclear fuel, it needs to make a test fuel rod and carry out burn-up test in the test loop of a research reactor to check the irradiation characteristics of the nuclear fuel. At that time, several sensors such as thermocouples, LVDTs and SPNDs are needed to be attached in and out of the fuel rod and connect them with instrumentation cables. Then, the instrumentation cables deliver the signals measured by the sensors to the measuring device located outside of the reactor pool. In particular, to install a thermocouple in a fuel rod, it needs to drill off holes on the alumina blocks and sintered $UO_2$ pellets. However, because the hardness of a sintered $UO_2$ pellet is 700 Hv (or HRC 61) and that of an alumina block is 1480 Hv, a special drilling machine which adapts a diamond coated drill bit had developed. In this study, several case experiments have been carried out to find an optimal drilling condition of the drilling machine. And, using the optimal drilling condition, minimum numbers of the holes that a drill bit can drill off are verified.

표준관입시험시 롯드에 전달되는 해머의 낙하에너지 평가 1 (The Hammer Energy Delivered to the Drilling Rod in the SPT 1)

  • 조성민;정종홍;김동수;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.469-476
    • /
    • 2001
  • The Ν-value in the standard penetration test(SPT) is affected by the magnitude of the rod penetration energy transmitted from the falling hammer as well as the geotechnical characteristics of the ground. Understanding of the striking energy efficiency in the SPT equipment is getting important for that reason. The energy efficiencies of the doughnut hammer with the hydraulic lift system and the automatic trip hammer system were investigated through field tests using the instrumented rod and wave-signal acquisition systems including the pile driving analyzer(PDA) . The rod energy ratio, ΕR$\_$r/ was defined as the ratio of the energy delivered to the drilling rod to the potential free-fall energy of the hammer. It appears that the type of the hammer and lift/drop system had a strong influence on the energy transfer mechanism and ΕR$\_$r/ also varies according to the energy instrumentation system and the analysis methods.

  • PDF

표준관입시험시 롯드에 전달되는 해머의 낙하에너지 평가 2 (The Hammer Energy Delivered to the Drilling Rod in the SPT 2)

  • 조성민;정종흥;이우진;김동수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.71-78
    • /
    • 2002
  • The N-value from the standard penetration test(SPT) is affected by the magnitude of the rod penetration energy transmitted from the falling hammer as well as the geotechnical characteristics of the ground. Understanding of the striking energy efficiency in the SPT equipment is getting important for that reason. The energy efficiencies of the various type of equipment were investigated through field tests using the instrumented rod and wave-signal acquisition systems including the pile driving analyzer(PDA). The rod energy ratio, ERr was defined as the ratio of the energy delivered to the drilling rod to the potential free-fall energy of the hammer. It appears that the type of the hammer and lift/drop system had a strong influence on the energy transfer mechanism and ERr also varies according to the energy instrumentation system and the analysis methods.

  • PDF

선재압연에서의 소재선단 미수냉부 발생원인 규명 (Investigation of the Causes of Uncooled Region Induced at Top End in Wire Rolling Process)

  • 손봉호;유재상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2516-2518
    • /
    • 2000
  • In order to reduce the trimming loss for water cooling zone next to finishing block mill in wire rolling, the operational data related to the crop length control of uncooled region was acquired and analyzed. The time deviation of water cooling spray nozzles and the immoderate preset length of uncooled wire rod result in the excessive trimming loss. Therefore, the preset length of uncooled wire rod at each cooling zone are established. The test results of #3 wire rolling mill turned out to be good enough to be expected to increase the ratio of products about 0.15% and establish operational standards of cooling zone.

  • PDF

The Mechanical Effect of Rod Contouring on Rod-Screw System Strength in Spine Fixation

  • Acar, Nihat;Karakasli, Ahmet;Karaarslan, Ahmet A.;Ozcanhan, Mehmet Hilal;Ertem, Fatih;Erduran, Mehmet
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권5호
    • /
    • pp.425-429
    • /
    • 2016
  • Objective : Rod-screw fixation systems are widely used for spinal instrumentation. Although many biomechanical studies on rod-screw systems have been carried out, but the effects of rod contouring on the construct strength is still not very well defined in the literature. This work examines the mechanical impact of straight, $20^{\circ}$ kyphotic, and $20^{\circ}$ lordotic rod contouring on rod-screw fixation systems, by forming a corpectomy model. Methods : The corpectomy groups were prepared using ultra-high molecular weight polyethylene samples. Non-destructive loads were applied during flexion/extension and torsion testing. Spine-loading conditions were simulated by load subjections of 100 N with a velocity of $5mm\;min^{-1}$, to ensure 8.4-Nm moment. For torsional loading, the corpectomy models were subjected to rotational displacement of $0.5^{\circ}\;s^{-1}$ to an end point of $5.0^{\circ}$, in a torsion testing machine. Results : Under both flexion and extension loading conditions the stiffness values for the lordotic rod-screw system were the highest. Under torsional loading conditions, the lordotic rod-screw system exhibited the highest torsional rigidity. Conclusion : We concluded that the lordotic rod-screw system was the most rigid among the systems tested and the risk of rod and screw failure is much higher in the kyphotic rod-screw systems. Further biomechanical studies should be attempted to compare between different rod kyphotic angles to minimize the kyphotic rod failure rate and to offer a more stable and rigid rod-screw construct models for surgical application in the kyphotic vertebrae.

Supervisory control of reheating furnace

  • Kim, Young-Il;Min, Kwang-Gi;Nam, In-Sik;Chang, Kun-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.538-541
    • /
    • 1995
  • In steel works, reheating furnace is an essential part of a rod mill plant and it treats various types of billets continuously. Although getting an optimal setting for a single billet is simple, control setting for whole groups of billets is a difficult task. In this work, we studied a detail mathematical model and optimal control setting of reheating furnace. As the mathematical model of each billet is a partial differential equation, on-line control is almost impossible for the whole billets charged into the furnace. Therefore, we tried to provide a guideline for optimal setting value of the roof(index) temperature for the target billets which account for about 20% of the charged billets.

  • PDF

RC 기술의 자동화 장치 개발에 관한 연구(I) -장치 설계 및 제작- (A Study on the Automation Equipment Development of RC Technology(I) -Equipment Design and Manufacture-)

  • 김기준;김상진;송자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.311-313
    • /
    • 1994
  • RC(Rod Consolidation) technology in spent nuclear fuel management is an essential method and requires remote operation due to radiation exposure. Its technology may provide an effective means to double the storage capacity of spent fuel storage space. So development of this technology will provide a valuable contribution to establishing economical as well as technological basis for future spent fuel management.

  • PDF