References
- Alkalay RN, Sharpe D, Bader DL : A biomechanical analysis of an instrumented spinal fixator under torsional loads. J Biomech 38 : 865-876, 2005 https://doi.org/10.1016/j.jbiomech.2004.04.029
- Baaj AA, Reyes PM, Yaqoobi AS, Uribe JS, Vale FL, Theodore N, et al. : Biomechanical advantage of the index-level pedicle screw in unstable thoracolumbar junction fractures. J Neurosurg Spine 14 : 192-197, 2011 https://doi.org/10.3171/2010.10.SPINE10222
- Belmont PJ Jr, Polly DW Jr, Cunningham BW, Klemme WR : The effects of hook pattern and kyphotic angulation on mechanical strength and apical rod strain in a long-segment posterior construct using a synthetic model. Spine (Phila Pa 1976) 26 : 627-635, 2001 https://doi.org/10.1097/00007632-200103150-00013
- Chen PQ, Lin SJ, Wu SS, So H : Mechanical performance of the new posterior spinal implant : effect of materials, connecting plate, and pedicle screw design. Spine (Phila Pa 1976) 28 : 881-886, 2003
- Chen WJ, Lai PL, Tai CL, Chen LH, Niu CC : The effect of sagittal alignment on adjacent joint mobility after lumbar instrumentation--a biomechanical study of lumbar vertebrae in a porcine model. Clin Biomech (Bristol, Avon) 19 : 763-768, 2004 https://doi.org/10.1016/j.clinbiomech.2004.05.010
- Gilad R, Gandhi CD, Arginteanu MS, Moore FM, Steinberger A, Camins M : Uncorrected sagittal plane imbalance predisposes to symptomatic instrumentation failure. Spine J 8 : 911-917, 2008 https://doi.org/10.1016/j.spinee.2007.10.035
- Karakasli A, Sekik E, Karaarslan A, Kizmazoglu C, Havitcioglu H : Are pedicular screws and lateral hook screws more resistant against pullout than conventional spinal hooks and screws in terminal vertebral segment fixation? Eklem Hastalik Cerrahisi 27 : 22-28, 2016 https://doi.org/10.5606/ehc.2016.05
- Kim H, Lim DH, Oh HJ, Lee KY, Lee SJ : Effects of nonlinearity in the materials used for the semi-rigid pedicle screw systems on biomechanical behaviors of the lumbar spine after surgery. Biomed Mater 6 : 055005, 2011 https://doi.org/10.1088/1748-6041/6/5/055005
- Kotani Y, Cunningham BW, Parker LM, Kanayama M, McAfee PC : Static and fatigue biomechanical properties of anterior thoracolumbar instrumentation systems. A synthetic testing model. Spine (Phila Pa 1976) 24 : 1406-1413, 1999 https://doi.org/10.1097/00007632-199907150-00004
- Lehman RA Jr, Polly DW Jr, Kuklo TR, Cunningham B, Kirk KL, Belmont PJ Jr : Straight-forward versus anatomic trajectory technique of thoracic pedicle screw fixation : a biomechanical analysis. Spine (Phila Pa 1976) 28 : 2058-2065, 2003 https://doi.org/10.1097/01.BRS.0000087743.57439.4F
- Liu T, Zheng WJ, Li CQ, Liu GD, Zhou Y : Design and biomechanical study of a modified pedicle screw. Chin J Traumatol 13 : 222-228, 2010
- Mikles MR, Asghar FA, Frankenburg EP, Scott DS, Graziano GP : Biomechanical study of lumbar pedicle screws in a corpectomy model assessing significance of screw height. J Spinal Disord Tech 17 : 272-276, 2004 https://doi.org/10.1097/01.bsd.0000095400.27687.89
- Okamoto T, Neo M, Fujibayashi S, Ito H, Takemoto M, Nakamura T : Mechanical implant failure in posterior cervical spine fusion. Eur Spine J 21 : 328-334, 2012 https://doi.org/10.1007/s00586-011-2043-8
- Ponnappan RK, Serhan H, Zarda B, Patel R, Albert T, Vaccaro AR : Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation. Spine J 9 : 263-267, 2009 https://doi.org/10.1016/j.spinee.2008.08.002
- Schroerlucke SR, Akbarnia BA, Pawelek JB, Salari P, Mundis GM Jr, Yazici M, et al. : How does thoracic kyphosis affect patient outcomes in growing rod surgery? Spine (Phila Pa 1976) 37 : 1303-1309, 2012 https://doi.org/10.1097/BRS.0b013e318246d8a0
- Smith JS, Shaffrey CI, Ames CP, Demakakos J, Fu KM, Keshavarzi S, et al. : Assessment of symptomatic rod fracture after posterior instrumented fusion for adult spinal deformity. Neurosurgery 71 : 862-867, 2012 https://doi.org/10.1227/NEU.0b013e3182672aab
- Stanford RE, Loefler AH, Stanford PM, Walsh WR : Multiaxial pedicle screw designs : static and dynamic mechanical testing. Spine (Phila Pa 1976) 29 : 367-375, 2004 https://doi.org/10.1097/01.BRS.0000092369.50397.85
- Sun E, Alkalay R, Vader D, Snyder BD : Preventing distal pullout of posterior spine instrumentation in thoracic hyperkyphosis : a biomechanical analysis. J Spinal Disord Tech 22 : 270-277, 2009 https://doi.org/10.1097/BSD.0b013e31816a6887
- Villa T, La Barbera L, Galbusera F : Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems. Spine J 14 : 695-704, 2014 https://doi.org/10.1016/j.spinee.2013.08.032
- Wahba GM, Bhatia N, Bui CN, Lee KH, Lee TQ : Biomechanical evaluation of short-segment posterior instrumentation with and without crosslinks in a human cadaveric unstable thoracolumbar burst fracture model. Spine (Phila Pa 1976) 35 : 278-285, 2010 https://doi.org/10.1097/BRS.0b013e3181bda4e6
- Wang XY, Dai LY, Xu HZ, Chi YL : Biomechanical effect of the extent of vertebral body fracture on the thoracolumbar spine with pedicle screw fixation : an in vitro study. J Clin Neurosci 15 : 286-290, 2008 https://doi.org/10.1016/j.jocn.2006.12.007
- Xu HZ, Wang XY, Chi YL, Zhu QA, Lin Y, Huang QS, et al. : Biomechanical evaluation of a dynamic pedicle screw fixation device. Clin Biomech (Bristol, Avon) 21 : 330-336, 2006 https://doi.org/10.1016/j.clinbiomech.2005.12.004
Cited by
- Straight-Forward versus Bicortical Fixation Penetrating Endplate in Lumbosacral Fixation-A Biomechanical Study vol.61, pp.2, 2016, https://doi.org/10.3340/jkns.2017.0404.004
- Utilization of Spinal Navigation to Facilitate Hassle-Free Rod Placement during Minimally-Invasive Long-Construct Posterior Instrumentation vol.13, pp.3, 2019, https://doi.org/10.31616/asj.2018.0233
- Measurement of strain in the rod for lumbar pedicle screw fixation: An experimental and finite element study vol.6, pp.6, 2016, https://doi.org/10.1088/2057-1976/abc607
- Avoiding Radical Removal of Posterior Elements in Posterior Vertebral Column Resections: A Modified Schwab Grade 6 Osteotomy for Severe Post-Tuberculous Kyphotic Deformity vol.150, pp.None, 2021, https://doi.org/10.1016/j.wneu.2021.03.114