• 제목/요약/키워드: Rod electrode

검색결과 114건 처리시간 0.034초

동결 토양에서 지중방전을 고려한 소규모 전극의 과도접지임피던스 특성 (Transient Ground Impedance of Small-sized Ground Electrode considering Underground Discharge in Frozen Soil)

  • 이태형;조성철;엄주홍;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.324-327
    • /
    • 2009
  • This paper presents the transient impedance in a discharge region when high voltage lightning impulse is applied to small-sized ground electrodes in frozen soil. For a realistic analysis of ionization characteristics near the ground electrode in the soil, ground rod installed outdoors and high voltage impulse voltage generator were used. From the analysis of response voltage and current flowing ground electrode to earth, it was verified that the ionization near the ground electrode contributes to reduction of ground impedance and limits the ground potential rise effectively under high impulse voltage.

  • PDF

제조공기를 이용한 Rod전극의 절연파괴특성 (Breakdown Characteristics of Rod-Electrodes using Imitation Air)

  • 송재우;장세우;안인석;장준오
    • 조명전기설비학회논문지
    • /
    • 제27권8호
    • /
    • pp.16-20
    • /
    • 2013
  • In this paper the experiments of breakdown characteristics by pressure and gap change of imitation air were described. The results are fundamental data for electric insulation design of distribution power facilities which will be studied and developed in the future. And we could make an environment friendly gas insulation material with mataining dielectric strength by Imitation Air which generates a lower lever of the global warming effect.

쉴딩차폐와 봉상접지에 관한 연구 (Study for shielded enclosure and rod grounding electrode)

  • 김주찬;김성삼;최종규;이충식;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.414-417
    • /
    • 2006
  • Especially, the case which the facilities have been shielded in the building. In this case there must be suitable grounding system, and this case must be considered sufficiently to the one part of the design at the design. in addition there must be an electric leakage defense system and The case to be a criterion signal ground system. Rod type grounding electrodes is applied much and we studied the relation that rod type grounding method and shielding room as newly grounding object. in this paper, shield room is the object(target) to be established newly additionally, we try to describe about the flow of a grounding technology concept change and a ground facilities.

  • PDF

접지극 형상에 따른 가로등 주변의 전위분포 (Potential Distribution near Street Linght according to the Grounding Electrode)

  • 이복희;백영환;정동철;안창환;심판섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1453-1454
    • /
    • 2007
  • A street light is an electrical equipment to improve the traffic safety and the security for people in night. However, many accidents due to electric shock have happened in recent, people were interested in the safety of electrical facilities. And people want to know the danger by touch and step voltages. When the electric power lines fall down on the ground, the fault current flows to ground rod and the potential near the ground rod is increased to induce the high touch and step voltages. In this paper, we installed different ground rods with a street light and investigated the electrical potential according to ground methods and the types of ground rod. Finally, we examined the electrical facilities with the experimental result and present the improved technical data for the safety from electric shock

  • PDF

접지저항 측정에 있어서 전류전극의 최소 이격거리 (Minimized Distance of the Current Electrode in the Measurement of Ground Resistance)

  • 이상무;강영흥;양준규
    • 조명전기설비학회논문지
    • /
    • 제20권10호
    • /
    • pp.68-73
    • /
    • 2006
  • 접지저항을 측정하는데 있어서 전류전극의 이격거리는 일반적으로 접지전극으로부터 전류전극에 이르기까지의 직선 구간상에서의 전압강하의 변화 곡선에 소위 평탄 구간이 존재하도록 이격하는 것으로 알려져 있다. 그러나 이러한 전류전극 이격 기준의 문제점은 그와 같은 조건을 만족하기에는 현실적으로 곤란한 측정 현장이 있다는 것이다. 이러한 문제의 보완을 위하여 본 논문은 실험적 측정 데이터를 활용, 분석하여 전류전극 이격거리의 최소 규격을 제시하였다. 분석 결과에 의하면 봉상접지에 대하여는 봉 길이의 2배 이상을, 메쉬접지에 대하여는 한 변 길이의 2배 이상 이격하여야 함을 알 수 있다.

휴대용 고농도 과산화수소 측정 전극의 개발 (Development of Portable-Type Electrode for the Determination of Highly Concentrated Hydrogen Peroxide)

  • 이진서;최강;김상진;차근식;남학현;노경래;김진두
    • 분석과학
    • /
    • 제12권2호
    • /
    • pp.125-129
    • /
    • 1999
  • 고농도의 과산화수소(10-75%)를 생산현장에서 손쉽게 측정할 수 있는 전극 센서 시스템을 연구하였다. Teflon 전극체는 휴대에 간편하도록 길이 10 cm, 지금 1.5 cm의 봉 형태로 제작하였고, 작업 극으로는 직경 3 mm의 glassy carbon을, 보조전극으로는 내경 5 mm, 외경 9 mm의 흑연을 전극물질로 사용하였다. 과산화수소 산화전위는 0.8 V의 전위를 걸어주었다. 공장에서 생산된 고농도의 과산화수소를 일정 이온강도의 전해질 용액으로 희석해 10% 이하의 농도가 되도록 하면 과산화수소에 첨가된 안정제의 방해작용과 과산화수소의 산화작용으로 인한 전극표면의 변성을 최소화할 수 있었고, 손쉽게 정량적인 측정을 할 수 있었다. 또한 과산화수소 투과막(teflon membrane${\leq}100{\mu}m$)을 입힌 전극을 이용하면 고농도의 과산화수소를 희석하지 않고 재현성 있게 정량할 수 있었다. 반면 투과막을 이용하는 방법을 내부전해질을 자주 교환해야 하는 단점이 있었다.

  • PDF

수중에 잠긴 접지전극주변에서 이온화에 의한 전위저감 및 에너지 방출의 평가 (Evaluation of the potential reduction and energy dispersion caused by ionization phenomena at the submerged ground rod)

  • 안상덕;최종혁;박건훈;양순만;이복희;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.337-340
    • /
    • 2008
  • When high surge voltage invaded into the ground rod contacted with ground water, the ionization phenomena are happened in the water. Although some researchers have surveyed the ionization phenomena in soil, they have just analyzed the variation of the ground resistance. The most important role of the ground rod is to elect human beings from potential rise and to dissipate energy to the earth safely. In this wort we presented the method evaluating the potential reduction and energy dispersion. Also we analyzed theses factors as a function of charging voltages at the water resistivity of $50\;{\Omega}{\cdot}m$ using the Matlab Program. As a result the ground rod potential was reduced to 38 kV by ionization just below breakdown voltage. The energy more than half of the total injected energy was dispersed through the grounding electrode caused due to ionization.

  • PDF

침상 접지봉의 임펄스접지임피던스에 미치는 지중방전의 영향 (Effects of Soil Discharges on the Impulsive Ground Impedance of Ground Rod with Needles)

  • 유양우;조성철;이복희
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.98-105
    • /
    • 2014
  • Soil discharges near the ground rod play an important role to reduce the ground potential rise and the ground impedance and to help the fault current to spread into the earth. This paper presents the effects of soil discharges on the transient and conventional ground impedances when the lightning impulse voltage was applied to a ground rod with radial needles. The current-voltage (I-V)curves and transient ground impedance curves were calculated based on the measured current and potential traces. Soil discharge behaviors related to I-V curves and transient ground impedance curves were analyzed as a function of the magnitude of lightning impulse voltages. As a result, the soil discharges occurred near the ground electrode contribute to the reduction of conventional ground impedance and limits the ground potential rise effectively under lightning impulse voltages.

Lightning Impulse Breakdown Characteristic of Dry-Air/Silicone Rubber Hybrid Insulation in Rod-Plane Electrode

  • Kwon, Jung-Hun;Seo, Cheong-Won;Kim, Yu-Min;Lim, Kee-Joe
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1181-1187
    • /
    • 2015
  • Sulfur hexafluoride (SF6) gas is used widely in electric power equipment such as Gas Insulated Switchgear (GIS), Gas Insulation transmission Line (GIL), and Gas Circuit Breaker (GCB). But applications of SF6 should be restricted because SF6 gas is one of the greenhouse effect gases. To reduce use of SF6 gas, a study on eco-friendly alternative insulation medium is needed. In this paper, we investigated lightning impulse (LI) breakdown of dry-air which is attracting attention as an ecofriendly alternative gas and the LI breakdown of hybrid insulation combined with dry-air and solid insulation (Room-Temperature Vulcanizing Silicone Rubber-RTV SIR) and dry-air in inhomogeneous fields according to gap distance and pressure. The experiment results showed that the LI breakdown strength of hybrid insulation system was higher than that of dry-air insulation system. It was verified that the development of technology related to eco-friendly power apparatus compact such GIS, GCB and GIL can be used as basic research data.

Distribution of Potential Rise as a Function of Shape of Grounding Electrodes

  • Gil, Hyoung-Jun;Choi, Chung-Seog;Kim, Hyang-Kon
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.73-79
    • /
    • 2007
  • In order to analyze the potential rise of grounding systems installed in buildings, a hemispherical grounding simulation system was studied. Potential rise was measured and analyzed regarding the shape and distance of the grounding electrodes by using this system. The system was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured in real time by the horizontal moving probe of be potentiometer. The test grounding electrodes were fabricated through reducing the grounding electrode installed in real buildings such as the ground rod, grounding grid and so on. The potential rise was displayed in a two-dimensional profile and was analyzed regarding the shapes of the ground electrodes. The potential rise of the grounding grid combined with a ground rod was the lowest of every grounding electrode tested. The proposed results can be applicable to evaluating ground potential rise in grounding systems, and the analytical data can be used to stabilize the electrical installations and prevent electrical disasters.