• Title/Summary/Keyword: Rockwell Hardness

Search Result 66, Processing Time 0.024 seconds

Rockwell Hardness Modeling Using Volumetric Variable (체적변수를 이용한 로크웰 경도 모델링)

  • Chin, Do-Hun;Oh, Sang-Rok;Yoon, Moon-Chul
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.394-401
    • /
    • 2013
  • A new Rockwell hardness (HRC) model using a volumetric parameter by a least square and fractal interpolation method is suggested. The results are also investigated in comparison to real measured hardness data. For this purpose, the measurement of an indented volume is performed using a confocal laser scanning microscope (CLSM), and the captured height encoded image (HEI) is used as an original surface for the calculation of the indented volume. After configuring the surface, the constructed volume is calculated and used as an independent variable for HRC hardness modeling. The hardness model is established using an experimental modeling technique involving a least square algorithm and fractal interpolating model, and this suggested model can be used to reliably predict the Rockwell hardness. These techniques can also be applied to the modeling of the Brinnell and Vickers hardnesses using a volumetric variable.

Indented Surface Configuration and its Volume Calculation (압입 표면형상의 구현과 체적계산법)

  • Yang, Jae-Yong;Yoon, Moon-Chul
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.708-713
    • /
    • 2012
  • The indented geometry for rockwell hardness indenter has been configured by using Confocal Laser Scanning Microscopy (CLSM). For this purpose, the CLSM can be well suited to construct the three-dimensional indented volume from the indented surface by rockwell hardness tester. Furthermore, the height data of HEI(height encoded image) by CLSM must be acquired at first and converted to indented surface later. And the indented surface patterns enable us to predict the indenter shape and volume. This volume can be used to study the rockwell hardness model as a volume parameter. As a result, the technique performed in this study by combining the CLSM with compensation technique is an excellent one to obtain the geometries of indented surfaces over a wide range of surface resolution in a micro scale. And it can be used for micro volume calculation.

Analysis on the Results of the Rockwell Hardness Round Robin Test (로크웰 경도도 순회 비교측정 결과에 대한 분석)

  • Bahng, G.W.;Tak, N.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.5
    • /
    • pp.275-281
    • /
    • 2001
  • To improve the reliability of hardness test results, Rockwell hardness round robin test was carried out for 10 laboratories. The test condition was the same with the ISO(International Standards Organization) standards. Korea Research Institute of Standards and Science(KRISS) supplied the hardness standard blocks and an indenter to laboratories for the measurement. The participating laboratories measured hardness of the specified areas on the blocks for 6 times with their own indenter as well as common indenter, respectively, and reported the results to KRISS. The result showed that quite large amount of the differences came from the indenter and it is necessary to change indenter with better quality for improved reliability in hardness measurement.

  • PDF

A Study on the Evaluation of Uncertainty of Rockwell Hardness C Scale According to the Korean Industrial Standards(KS) (한국산업표준(KS)에 따른 로크웰 경도 시험기의 불확도 산정에 관한 연구)

  • Bahng, G.W.;Tak, Nae-Hyung
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.3
    • /
    • pp.163-169
    • /
    • 2000
  • Recently, uncertainty of hardeness became a major concem for the people working on the laboratory evaluation and accreditation. It is required to indicate uncertainty of hardness tester on the report after calibration. In addition to this, uncertainty of certified hardness reference block is also required to indicate on the certification sheet. Method on the evaluation of uncertainty in hardness measurement is agreed only recently for Rockwell hardness C scale. In this paper, a preliminary calculation of uncertainty based on type B evaluation has been made for hardness testers which satisfies the requirements of Korean Standards. It was found that the tolerance limit of mean value specified in KS should be increased to be compatible with the calculated uncertainty.

  • PDF

Analysis on the Results of the World Wide Rockwell Hardness Round Robin Test with Conical Indenters (로크웰 경도 국제비교교정 결과 분석)

  • Bahng, G.W.;Tak, N.H.;Polzin, T.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.6
    • /
    • pp.336-344
    • /
    • 2001
  • For the establishment of the world wide unified scales of the Rockwell hardness test with conical indenters, round robin test was carried from 1998 to 2000. The pilot laboratory was MPA-NRW and 12 laboratories from 11 countries participated In this RRT. Rockwell hardness of 74 specially prepared blocks was measured for the scales of C, A, D, 45N, 30N, and 15N and the results were compared. It was found that the geometric form of indenter affects on the results very significantly and standardization in the measurement and evaluation of indenter should be established in short time for the reliable hardness measurement. KRISS showed good results in general for all of the ranges except 15N scale which showed relatively large difference compare to the mean value. It was concluded that poor control in loading velocity of the dash pot was the major reason.

  • PDF

Effect Boron and Silicon on Various Properties of Dental Cobalt-Chromium Alloys (치과용 Co-Cr 합금의 제성질에 미치는 Boron과 Silicon의 영향)

  • Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.14 no.1
    • /
    • pp.119-132
    • /
    • 1992
  • This paper aims to investigate the effect of B and Si upon the mechanical properties, microstructure and corrosion resistance of Co-Cr base alloy. Ten groups of alloy ingot ingot with various contents of B and Si were remelted by high frequency electrical induction furnace and cast into tensile specimen of ADA Specification No. 14 Tensile and hardness test were carried out by Amsler and Rockwell hardness tester(R-30N), respectively. The microstructures of specimen were observed by SEM. The results obtained are summarized as follows : 1. As B content is increased, tensile strength, yield strength and Rockwell hardness number(R-30N) are also increased significantly, while the elongation is decreased significantly. 2. As Si contect os increased, no significant chang in tensile strength is noticed, yield strength is slightly decreased, but Rockwell hardness number(R-30N) is moderately in creased, Elongation marks maxium value with 1% Si content while with more than 1% Si it is decreased. 3. As B content is increased corrosion resistance is decreased and is at best with 1.5% B content. Corrosion resistance is increased with the increase of Si content and the alloys with Si over 3.0% showed corrosion resistance. 4. As B content increased, precipitates are increased in number at grain boundaries. The grain size tends to become coarse with the increase of Si content. 5. Co rich-Cr alloy is present through matrix whereas at the grain boundaries Cr base precipitates are primarily formed.

  • PDF

Effect of Isothermal Aging on the Magnetic Properties of 1Cr-0.5Mo Steel

  • Kim, Min-Gi;Ryu, K.S.;Lee, Y.H.;Park, J.S.;Kim, C.G.
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.225-228
    • /
    • 2011
  • Magnetic properties and Rockwell hardness of 1Cr-0.5Mo steel have been investigated as a function of isothermal aging time. Our results showed that coercivity, hysteresis loss and Rockwell hardness in the aged samples decreased as aging time increased. This phenomenon was analyzed using optical microscopy and scanning electron microscopy. A significant diffusion of Cr and Mo atoms formed $M_2C$ and $M_7C$ carbides, lowering the matrix strength. $M_2C$ and $M_7C$ carbides partially segregated inside grains, diffused into grain boundaries, and finally resulted in a soft ferrite matrix and a hard grain boundary. The magnetic and mechanical softening of the matrix is likely to govern the properties of the sample more than the hardening of the grain boundary by carbide precipitations.

Experimental Studies on the Improving Surface Hardness of Dental Stone (치과용(齒科用) 경석고(硬石膏) 의 표면경도(表面硬度) 강화(强化)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.23-27
    • /
    • 1969
  • The purpose of this studies is to determine the surface hardness of dental stone and to investigate the methods which increase the surface hardness of dental stone using the dissolved solution of various synthetic resin, the obtained results of hardness value calculated Rockwell Hardness Number by means of Rockwell Hardness Tester. 1) In this experiment, 10% polystyrene dissolved in 100cc amylacetate is excellent solution which provides the surface hardness of dental stone after setting of specimen, and there is no effective way that stone specimen is immersed into polystyrene in amylacetate, polystyrene in benzene and polystyrene in butylacetate above 1 hour. 2) When the stone specimen is immersed into acrylic resin in benzene and melamin resin in amylacetate at least 1 hour to 3 hours, the hardening effect of stone surface is valuable. 3) The stone specimen immersing into urea resin in butylacetate, the surface hardness of the stone specimen decreased within 1 hour, but increased after 3 houre. 4) For the separating medium, the easyfoil is superior to the olive oil in the aspect of improving the hardening effect of the immersed specimen.

  • PDF

Effect of Time-Related Parameters on Rockwell Hardness Measurement (시험시간 관련인자가 로크웰 경도측정에 미치는 영향)

  • Bahng Gun Woong;Tak Nae-Myung
    • Polymer(Korea)
    • /
    • v.29 no.6
    • /
    • pp.536-542
    • /
    • 2005
  • The effect of lime-related parameters such as loading velocity, load application time, gauge reading time on Rockwell hardness measurement was investigated for PE, PP PVC, and PMMA. It was found that keeping the specific requirements in the same condition is very important to obtain reliable and repeatable darn in polymer hardness measurement. The optimum condition for hardness measurement was 4 sec for load application time,15 sec for test load application net time, and 15 sec for gauge reading time after unloading. Using thess conditions, round robin test was carried out for 6 laboratories and it was shown that the testing machine should be one in which time-related variables are controllable. Indirect verification of hardness tester using brass reference block was not enough to guarantee the test results for polymer.

Study on the Hardness Measurement of Earthenware : Focusing on the Cup of the Baekje (토기의 경도측정법 연구: 백제시대 배(杯)류를 중심으로)

  • Moon, Eun-Jung;Kang, Hee-Jun;Kim, Su-Kyoung;Lee, Han-Hyoung;Hong, Jong-Ouk;Hwang, Jin-Ju
    • Journal of Conservation Science
    • /
    • v.25 no.4
    • /
    • pp.431-438
    • /
    • 2009
  • We have investigated the suitable measuring method and condition on the hardness testing for the earthenwares excavated from Poongnap mud castle in Hanseong Baekje period. The earthenwares which used on hardness testing have been classified according to Mohs hardness and external form and color. The Ultrasonic and Equotip testing method have used to the hardness testing on the surface of the earthenwares and the Rockwell and Micro-vickers testing methods have used to the hardness testing on the cross section of the earthenwares. As the results, the two methods applied to the surface of the earthenwares were very hard on the precise measurement and the measuring values were incompatible with the tendency classified according to Mohs hardness and external form and color. On the testing for the cross section of earthenware, the Rockwell-superficial hardness testing method was more suitable for the soft texture earthenware and highest reproducibility of the measuring value obtained at the test load and indentor are 15kgf and 1/16 “iron ball, respectively. The Micro-Vickers hardness testing method was suitable for the hard texture earthenware and highest reproducibility and accuracy of the measuring value obtained at the test load is 100gf. This results show strong possibility of progress on the classifying and comparing study for hardness of the earthenware and therefore active studies are expected on the field.

  • PDF