• 제목/요약/키워드: Robust current control

검색결과 303건 처리시간 0.03초

유도전동기의 고성능제어를 위한 속도센서리스 벡터제어 (Speed Sensorless Vector Control for High Performance of Induction Motor)

  • Dong Hwa Chung
    • 전자공학회논문지B
    • /
    • 제30B권11호
    • /
    • pp.37-46
    • /
    • 1993
  • Recently, the elimination of speed sensors has been one of the important requirement in vector control systems, because the speed sensor spoil the ruggedness and simplicity of induction motor. This paper proposes sensorless vector control for high performance of induction motor. The proposed vector control scheme is based on a rotor flux and speed which are calculated from the stator voltage and currents with improved flux estimator. The characteristics of vector control employing stator voltage and current generally deteriorate as the speed gets lower acause the calculated rotor flux depends on the stator resistance and it is difficult to calculate rotor flux at low speed of standstill. This new control system is robust with respect to variations of the stator resistance and it makes possible to calculated rotor flux at low speed of standstill. These feature are verified by the simulation results.

  • PDF

자동차 환경내 안정적인 VoIP 시스템을 위한 네트워크 지터 추정 알고리즘 (Network Jitter Estimation Algorithm for Robust VoIP System in Vehicle Environment)

  • 서광덕;이진호;김형국
    • 한국ITS학회 논문지
    • /
    • 제10권4호
    • /
    • pp.93-99
    • /
    • 2011
  • 본 논문에서는 자동차 환경내 안정된 VoIP 통신시스템을 위한 새로운 네트워크 지터 추정 알고리즘을 제안한다. 제안된 알고리즘은 패킷간의 도착시간과 생성시간 차이를 계산하여 패킷이 겪은 현재 네트워크 환경을 추정하고, 추정된 네트워크 환경을 통해 네트워크 지터 추정에 사용될 네트워크 지터 분산 가중치를 조정한 후에, 조정된 지터 분산 가중치와 네트워크 지터의 평균과 분산을 계산하여 다음에 도착할 패킷의 네트워크 지터를 추정한다. 본 논문에서는 WiFi를 이용한 VoIP에서 수신단에 도착한 패킷에 대해 Delay와 Loss를 측정함으로써 제안된 방식의 우수성을 입증하였다.

UPS 인버터의 성능 개선을 위한 강인한 2중 디지털 제어기의 설계 (Design of Robust Double Digital Controller to Improve Performance for UPS Inverter)

  • 박지호;노태균;김춘삼;안인모;우정인
    • 전력전자학회논문지
    • /
    • 제8권2호
    • /
    • pp.116-127
    • /
    • 2003
  • 본 논문에서는 UPS 인버터의 성능 개선을 위하여 출력측 LC 필터의 커패시터 전압과 전류의 2중 제어루프를 구성하고, 2중 제어루프에 디지털 제어시스템을 채택하였다 또한, 디지털 제어기의 연산지연시간을 보상하기 위하여 이러한 연산지연시간을 인버터 플랜트의 고유한 파라미터로 가정하고, 플랜트 모델에 포함시켜 모델링 하였다. UPS 인버터 출련전압의 과도상태 응답특실을 개선하고, 파라미터 변동에 강인한 특성을 얻기 위하여 2중 제어루프에서 내부 전류 제어루프는 내부 모델 제어기를 제안하였다. UPS 인버터 출력전압의 0의 정상상태 오차를 얻기 위하여 외부 전압 제어루프는 비례 제어기와 공진 제어기를 병렬로 연결한 비례-공진 진압제어기를 제안하였다.

FNN 제어기를 이용한 유도전동기 드라이브의최대토크 제어 (Maximum Torque Control of Induction Motor Drive using FNN Controller)

  • 정동화;김종관;박기태;차영두
    • 조명전기설비학회논문지
    • /
    • 제19권8호
    • /
    • pp.33-39
    • /
    • 2005
  • 본 논문에서는 퍼지와 신경회로망을 혼합한 FNN(Fuzzy Neural Network) 제어기를 이용한 유도전동기의 최대 토크 제어를 제시한다. 먼저 유도전동기 드라이브의 고성능 제어를 위하여 FNN 제어기를 설계한다. 다음은 유도전동기의 최대토크 제어를 위하여 주어진 부하토크에서 고정자 전류를 최소화하여 단위 전류당 발생토크를 높인다. 본 논문에서 제시한 FNN을 이용한 최대토크 제어의 특성을 분석하고 그 결과를 제시한다.

영구자석 동기모터를 위한 CTRNN모델 기반 적응형 PI 제어기 설계 (Adaptive PI Controller Design Based on CTRNN for Permanent Magnet Synchronous Motors)

  • 김일환
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.635-641
    • /
    • 2016
  • In many industrial applications that use the electric motors robust controllers are needed. The method using a neural network in order to design a robust controller when a disturbance occurs is studied. Backpropagation algorithm, which is used in a conventional neural network controller is used in many areas, but when the number of neurons in the input layer, hidden layer and output layer of the neural network increases the processing speed of the learning process is slow. In this paper an adaptive PI(Proportional and Integral) controller based on CTRNN(Continuous Time Recurrent Neural Network) for permanent magnet synchronous motors is presented. By varying the load and the speed the validity of the proposed method is verified through simulation and experiments.

Adaptive Reversal Tree Protocol with Optimal Path for Dynamic Sensor Networks

  • 황광일
    • 한국통신학회논문지
    • /
    • 제32권10A호
    • /
    • pp.1004-1014
    • /
    • 2007
  • In sensor networks, it is crucial to reliably and energy-efficiently deliver sensed information from each source to a sink node. Specifically, in mobile sink (user) applications, due to the sink mobility, a stationary dissemination path may no longer be effective. The path will have to be continuously reconfigured according to the current location of the sink. Moreover, the dynamic optimal path from each source to the sink is required in order to reduce end-to-end delay and additional energy wastage. In this paper, an Adaptive Reversal Optimal path Tree (AROT) protocol is proposed. Information delivery from each source to a mobile sink can be easily achieved along the AROT without additional control overhead, because the AROT proactively performs adaptive sink mobility management. In addition, the dynamic path is optimal in terms of hop counts and the AROT can maintain a robust tree structure by quickly recovering the partitioned tree with minimum packet transmission. Finally, the simulation results demonstrate that the AROT is a considerably energy-efficient and robust protocol.

전압제어형 능동전력필터를 위한 강인한 이산가변구조제어기 설계 (The Robust Discrete Variable Structure Controller for the Voltage Controlled Active Power Filter)

  • 김병진;전희종;정헌상
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권11호
    • /
    • pp.563-567
    • /
    • 2001
  • ln this paper, the designed DVSC(Discrete Variable Structure Controller) is applied to the robust control of voltage controlled APF(Active Power Filter). The voltage controlled APF has good characteristics of reducing harmonic current and harmonic voltage simultaneously. However, voltage controlled APF with large capacitor has slow dynamic response. For improving the dynamics and robustness against to disturbances, DVSC is adopted. According to the results of experiment and simulation, it is proved that the proposed system has the performance of improving dynamic response and robustness.

  • PDF

복소 벡터 동기좌표계 비례 적분 전류 제어기의 안티와인드업 이득 설정 (Anti-windup for Complex Vector Synchronous Frame PI Current Controller)

  • 유현재;정유석;설승기
    • 전력전자학회논문지
    • /
    • 제11권5호
    • /
    • pp.404-408
    • /
    • 2006
  • 본 논문에서는 복소 벡터 동기 좌표계 비례 적분(PI) 전류 제어기의 안티 와인드업(anti-windup)이득 설정에 대해 논의한다. 복소 벡터 동기 좌표계 비례 적분 전류 제어기는 시스템 제정수 변동에 기존의 비례 적분 전류 제어기 보다 더 강인한 특성을 보인다. 복소 벡터 전류 제어기 역시 적분기를 포함하고 있으며, 엑츄에이터(actuator)의 물리적인 한계로 전압이 포화되는 경우에는 안티 와인드업이 필요하게 되고, 적절치 못한 안티 와인드업 이득 설정은 제어 시스템의 동특성을 저하시킬 수 있다. 따라서 복소 벡터 동기 좌표계 비례 적분 전류 제어기에 적합한 안티 와인드업 이득을 제안하였고, 제안된 알고리즘의 유효성은 실험을 통하여 검증하였다.

Analysis and Design of Sliding Mode Control for a Single-Phase AC-DC Converter

  • Sawaengsinkasikit, Winyu;Tipsuwanporn, Vittaya;Tarasantisuk, Chanlit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2291-2294
    • /
    • 2003
  • In this paper, analysis and control design of ac-dc converter, normally nonlinear time-varying system, using sliding mode controller to achieve fast output voltage response, disturbance rejection and robust system in the presence of load variation are demonstrated. The objective of this method is to develop methodology for output voltage to be constant and input current sinusoidal that results in nearly unity power factor, respectively. In addition the converter can be also bidirectional power flow. Simulation results using Matlab/Simulink show the effectiveness of sliding mode control system compared with linear feedback controller to guarantee enhanced PF>0.98, THD<5%, and ripple output voltage is less than 1% at the maximum output power.

  • PDF

PMSM 토크제어를 위한 보간오차 보상방법 (Interpolation Error Compensation Method for PMSM Torque Control)

  • 이정효
    • 전기학회논문지
    • /
    • 제67권3호
    • /
    • pp.391-397
    • /
    • 2018
  • This paper proposes a interpolation error compensation method for PMSM torque control. In PMSM torque control, two dimensions look-up table(2D-LUT) is used for current reference generation due to its stable and robust torque control performance. However, the stored data in 2D-LUT is discreet, it is impossible to store all over the operation range. To reduce the reference generation error in this region, the 2D-Interpolation method is conventionally used, however, this method still remains the error affected by the number of stored data. Besides, in the case stored by fixed unit, this error is increased in field weakening region because of the small number of stored data. In this paper, analyzing the cause of this interpolation error, and compensating the method to reduce this error. Proposed method is verified by the simulation and experiment.