• Title/Summary/Keyword: Rit

Search Result 45, Processing Time 0.025 seconds

Synthesis of Curcumin Glycosides with Enhanced Anticancer Properties Using One-Pot Multienzyme Glycosylation Technique

  • Gurung, Rit Bahadur;Gong, So Youn;Dhakal, Dipesh;Le, Tuoi Thi;Jung, Na Rae;Jung, Hye Jin;Oh, Tae Jin;Sohng, Jae Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.9
    • /
    • pp.1639-1648
    • /
    • 2017
  • Curcumin is a natural polyphenolic compound, widely acclaimed for its antioxidant, anti-inflammatory, antibacterial, and anticancerous properties. However, its use has been limited due to its low-aqueous solubility and poor bioavailability, rapid clearance, and low cellular uptake. In order to assess the effect of glycosylation on the pharmacological properties of curcumin, one-pot multienzyme (OPME) chemoenzymatic glycosylation reactions with UDP-${\alpha}-{\text\tiny{D}}$-glucose or UDP-${\alpha}-{\text\tiny{D}}$-2-deoxyglucose as donor substrate were employed. The result indicated significant conversion of curcumin to its glycosylated derivatives: curcumin 4'-O-${\beta}$-glucoside, curcumin 4',4"-di-O-${\beta}$-glucoside, curcumin 4'-O-${\beta}$-2-deoxyglucoside, and curcumin 4',4"-di-O-${\beta}$-2-deoxyglucoside. The products were characterized by ultra-fast performance liquid chromatography, high-resolution quadruple-time-of-flight electrospray ionization-mass spectrometry, and NMR analyses. All the products showed improved water solubility and comparable antibacterial activities. Additionally, the curcumin 4'-O-${\beta}$-glucoside and curcumin 4'-O-${\beta}$-2-deoxyglucoside showed enhanced anticancer activities compared with the parent aglycone and diglycoside derivatives. This result indicates that glycosylation can be an effective approach for enhancing the pharmaceutical properties of different natural products, such as curcumin.

Introduction and feasibility study of the HD-270 MLC (HD-270 MLC의 소개 및 유용성평가)

  • Kim Dae Young;Kim Won Taek;Lee Hwa Jung;Lee Kang Hyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • I. Purpose The multileaf collimator(MLC) has many advantages, but use of the MLC increased effective penumbra and isodose undulation in dose distribution compared with that of an alloy block. In this work, we introduced the HD-270 MLC, which can improve the above disadvantages of MLC, and reported its feasibility study. II. Method and Materials The HD-270 MLC is a technique which combines the use of the existing Siemens multileaf collimator(3D MLC) with patient translation perpendicular to the leaf plane. The technique produces a smoothed isodose distribution with the reduced isodose undulation and effective penumbra. To assess the efficacy of the HD-270 technique and determine the appropriate resolution, a polygonal shaped MLC field was made to produce field edge angles from 0 degree to 75 degree with a step of 15 degree. Each HD-270 group was generated according to the allowed resolution, i. e., 5, 3, and 2mm. The experiment was carried out on Primus, a Siemens linear accelerator configured with HD-270 MLC. The total 60 MU of 6 MV photon beam was delivered to X-Omat film(Kodak, USA) at a SAD of 100 cm and 1.5 cm depth in solid water phantom. Exposed films were scanned by Lumiscan75(LUMISYS) and analyzed using RIT113 software(Radiological Imaging Technology Inc., USA). To test the mechanical accuracy of table movement, the transverse, longitudinal, and vertical positions were controlled by a consol with ${\pm}5\;mm,\;{\pm}4\;mm,\;{\pm}3\;mm,\;and\;{\pm}2\;mm$ steps, and then measured using a dial gauge with an accuracy of 0.001 inch. During the experiments, the table loaded with about 50Kg human phantom to simulate the real treatment situation. III. Results The effective penumbra and isodose undulation became larger with increase the resolution and field edge angle. The accuracy of the table movement on each direction is good within the ${\pm}1\;mm$. IV. Conclusion Clinical use of the MLC can be increased by using of the HD-270 MLC which complements to the disadvantages of the MLC.

  • PDF

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus (전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교)

  • Kim, Byeong Soo;Park, Ju Young;Park, Byoung Suk;Song, Yong Min;Park, Byung Soo;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 2014
  • Purpose : If electron, chosen for superficial oncotherapy, was applied with bolus, it could work as an important factor to a therapy result by showing a drastic change in surface dose. Hence the calculation value and the actual measurement value of surface dose of Treatment Planning System (TPS) according to four variables influencing surface dose when using bolus on an electron therapy were compared and analyzed in this paper. Materials and Methods : Four variables which frequently occur during the actual therapies (A: bolus thickness - 3, 5, 10 mm, B: field size - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: energy - 6, 9, 12 MeV, D: gantry angle - $0^{\circ}$, $15^{\circ}$) were set to compare the actual measurement value with TPS(Pinnacle 9.2, philips, USA). A computed tomography (lightspeed ultra 16, General Electric, USA) was performed using 16 cm-thick solid water phantom without bolus and total 54 beams where A, B, C, and D were combined after creating 3, 5 and 10 mm bolus on TPS were planned for a therapy. At this moment SSD 100 cm, 300 MU was investigated and measured twice repeatedly by placing it on iso-center by using EBT3 film(International Specialty Products, NJ, USA) to compare and analyze the actual measurement value and TPS. Measured film was analyzed with each average value and standard deviation value using digital flat bed scanner (Expression 10000XL, EPSON, USA) and dose density analyzing system (Complete Version 6.1, RIT, USA). Results : For the values according to the thickness of bolus, the actual measured values for 3, 5 and 10 mm were 101.41%, 99.58% and 101.28% higher respectively than the calculation values of TPS and the standard deviations were 0.0219, 0.0115 and 0.0190 respectively. The actual values according to the field size were $6{\time}6$, $10{\time}10$ and $15{\time}15cm2$ which were 99.63%, 101.40% and 101.24% higher respectively than the calculation values and the standard deviations were 0.0138, 0.0176 and 0.0220. The values according to energy were 6, 9, and 12 MeV which were 99.72%, 100.60% and 101.96% higher respectively and the standard deviations were 0.0200, 0.0160 and 0.0164. The actual measurement value according to beam angle were measured 100.45% and 101.07% higher at $0^{\circ}$ and $15^{\circ}$ respectively and standard deviations were 0.0199 and 0.0190 so they were measured 0.62% higher at $15^{\circ}$ than $0^{\circ}$. Conclusion : As a result of analyzing the calculation value of TPS and measurement value according to the used variables in this paper, the values calculated with TPS on 5 mm bolus, $6{\time}6cm2$ field size and low-energy electron at $0^{\circ}$ gantry angle were closer to the measured values, however, it showed a modest difference within the error bound of maximum 2%. If it was beyond the bounds of variables selected in this paper using electron and bolus simultaneously, the actual measurement value could differ from TPS according to each variable, therefore QA for the accurate surface dose would have to be performed.

Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy (Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가)

  • Lee, Hun Hee;Kim, Chan Kyu;Song, Kwan Soo;Bang, Mun Kyun;Kang, Dong Yun;Sin, Dong Ho;Lee, Du Heon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose : In this study, we evaluated the usefulness of colloid gel(slime) as a compensator for irregular patient surfaces in radiation therapy. Materials and Methods : For this study, colloid gel suitable for treatment was made and four experiments were conducted to evaluate the applicability of radiation therapy. Trilogy(Varian) and CT(SOMATOM, Siemens) were used as treatment equipment and CT equipment. First, the homogeneity according to the composition of colloid gel was measured using EBT3 Film(RIT). Second, the Hounsfield Unit(HU) value of colloid gel was measured and confirmed by CRIS phantom, Eclipse RTP(Eclipse 13.1, Varian) and CT. Third, to measure the deformation and degeneration of colloid gel during the treatment period, it was measured 3 times daily for 2 weeks using an ion chamber(PTW-30013, PTW). The fourth experiment was compared the treatment plan and measured dose distributions using bolus, rice, colloid gel and additional, dose profiles in an environment similar to actual treatment using our own acrylic phantom. Result : First experiment, density of the colloid gel cases 1, 2 and 3 was $1.02g/cm^3$, $0.99g/cm^3$ and $0.96g/cm^3$. When the homogeneity was measured at 6 MV and 9 MeV, case 1 was more homogeneous than the other cases, as 1.55 and 1.98. In the second experiment, the HU values of case 1, 2, 3 were 15 and when the treatment plan was compared with the measured doses, the difference was within 1 % at all 9, 12 MeV and a difference of -1.53 % and -1.56 % within the whole 2 % at 6 MV. In the third experiment, the dose change of colloid gel was measured to be about 1 % for 2 weeks. In the fourth experiment, the dose difference between the treatment plan and EBT3 film was similar for both colloid gel and bolus, rice at 6 MV. But colloid gel showed less dose difference than bolus and rice at 9 MeV. Also, dose profile of colloid gel showed a more uniform dose distribution than the bolus and rice. Conclusion : In this study, the density of colloid gel prepared for radiation therapy was $1.02g/cm^3$ similar to the density of water, and alteration or deformation was not observed during the radiotherapy process. Although we pay attention to the density when manufacturing colloid gel, it is sufficient in that it can deliver the dose uniformly through the compensation of the patient's body surface more than the bolus and rice, and can be manufactured at low cost. Further studies and studies for clinical applications are expected to be applicable to radiation therapy.

  • PDF

Effects of Ginseng Feeding on the Recovery of Posthemorrhagic Anemia and Erythrokinetics in Rabbits (인삼이 사혈성빈혈 회복 및 Erythrokinetics에 미치는 영향)

  • Park, Yong-Duck;Lee, In-Sook;Kim, Myung-Sun
    • The Korean Journal of Physiology
    • /
    • v.15 no.1
    • /
    • pp.9-18
    • /
    • 1981
  • For centuries, ginseng has been used for the therapeutic purpose in oriental herb medicine. Several studies have been conducted in the past to evaluate the effect of ginseng on erythropoiesis. However the results were controversial. We therefore attempted in the present studies to evaluate the effect of ginseng on the erythropoietic activity. In one series of experiments, the recovery pattern of peripheral blood(red cell count, hemoglobin content, hematocrit and reticulocyte count) was studied in posthemorrhagic anemic rabbits. After animals were maintained with normal(control group) or 1 gm% ginseng (experimental group) diet for 2 weeks, hemorrhagic anemia was induced by withdrawing blood equivalent to 25% of the total blood volume and then changes in peripheral blood were followed for following 30 days. In other series of experiments, we studied effect of ginseng on erythrokinetics using $^{59}Fe$. $^{59}Fe(10{\sim}40\;{\mu}Ci/animal)$ was injected intravenously after animals were fed with normal (control group) or 1 gm% ginseng(experimental group) diet for 2 weeks. And radioactivities in the blood compartments were measured at appropriate intervals for 15 days. Front these various erythrokinetic parameters were estimated. Results are summarized as follows: 1) Reticulocyte count was higher in the experimental group than in the control group after 2 weeks of administration of experimental diet. During the posthemorrhagic period, the reticulocyte count increased in both the control and experimental groups, but the increase appeared much earlier in the experimental group. 2) The posthemorrhagic recoveries of hematocrit, hemoglobin content and red cell count appeared to be faster in the experimental group as compaired with the control group. 3) The half life$(T_{1/2})$ of $^{59}Fe$ in the plasma was significantly(P<0.05) shorter in the experimental group(82.6 min, N=8) than in the control group(121 min, N=6). Plasma iron turnover (PIT) of the experimental group (1.78 mg/dl/24 hr.) was approximately 4 times greater than that of the control group(0.45 mg/dl/24 hr.). 4) The maximum red cell utilization(RC-U) was 82.1% in the experimental group ana 74.5% in the control group. Red cell iron turnover(RIT) of the experimental group(1.62 mg/dl/24 hr.) was slightly higher than that of the control group(0.35 mg/dl/24 hr). 5) Erythron turnover was significantly(p<0.05) greater in the experimental group(1.27 mg/dl/24 hr.) than in the control group(0.24 mg/dl/24 hr.). Marrow transit time of the experimental group(2.05 days) tended to he faster than that of the control group(2.84 days). These results suggest that the gingseng improves the recovery of posthemorrhagic anemia and stimulates the erythropoiesis in rabbits.

  • PDF

Analysis of changes in dose distribution due to respiration during IMRT

  • Shin, Jung-Suk;Shin, Eun-Hyuk;Han, Young-Yih;Ju, Sang-Gyu;Kim, Jin-Sung;Ahn, Sung-Hwan;Kim, Tae-Gyu;Jeong, Bae-Kwon;Park, Hee-Chul;Ahn, Young-Chan;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.29 no.3
    • /
    • pp.206-213
    • /
    • 2011
  • Purpose: Intensity modulated radiation therapy (IMRT) is a high precision therapy technique that can achieve a conformal dose distribution on a given target. However, organ motion induced by respiration can result in significant dosimetric error. Therefore, this study explores the dosimetric error that result from various patterns of respiration. Materials and Methods: Experiments were designed to deliver a treatment plan made for a real patient to an in-house developed motion phantom. The motion pattern; the amplitude and period as well as inhale-exhale period, could be controlled by in-house developed software. Dose distribution was measured using EDR2 film and analysis was performed by RIT113 software. Three respiratory patterns were generated for the purpose of this study; first the 'even inhale-exhale pattern', second the slightly long exhale pattern (0.35 seconds longer than inhale period) named 'general signal pattern', and third a 'long exhale pattern' (0.7 seconds longer than inhale period). One dimensional dose profile comparisons and gamma index analysis on 2 dimensions were performed. Results: In one-dimensional dose profile comparisons, 5% in the target and 30% dose difference at the boundary were observed in the long exhale pattern. The center of high dose region in the profile was shifted 1 mm to inhale (caudal) direction for the 'even inhale-exhale pattern', 2 mm and 5 mm shifts to exhale (cranial) direction were observed for 'slightly long exhale pattern' and 'long exhale pattern', respectively. The areas of gamma index >1 were 11.88 %, 15.11%, and 24.33% for 'even inhale-exhale pattern', 'general pattern', and 'long exhale pattern', respectively. The long exhale pattern showed largest errors. Conclusion: To reduce the dosimetric error due to respiratory motions, controlling patient's breathing to be closer to even inhaleexhale period is helpful with minimizing the motion amplitude.

A comparative study of the Dunhuang Costume on the Folk Song's words in Dnag's period of the China. (중국.고대 돈황가중의 복식 연구)

  • 김은주
    • Journal of the Korean Society of Costume
    • /
    • v.22
    • /
    • pp.159-176
    • /
    • 1994
  • This study's purpose is to find the ancient costume of the folk song's words on Dunhuang manuscripts in the background wass-carvings sculptures and several art works. Dunhuang had played the part of major route between ancient China and Europe. It is located on kam-suksong the west of China. 1. In the aspect of costume arrangement hair Styling is represented by Naegagyo, Wangyesa, Kyongburak, Bonkwyun, Pogurak, Chonsonja, Namgaja, Tongson-ga, Ojesa, Chanboja in Dunhuang manuscripts. tugue is sim-ilar to Sabyokkwanja in Naegagyo as of that time these kinds of Kwan-ja was very popular. It was told that emperor's wife concubine and maid of honor would wear kwnaja favorably. And the kinds of Tugeu is PuyongKwyunkye, Aangunkye, Chunkye from Kyuwanjon except Sangunkye, Ounkye in Dunhuangsa. 2. Jangdaegy is guoted from Kyuw-anjon -A series of the chinese history book-tells us about women's make-up . The narmes of make-up are Hongjang Unjan--g, Yiljang chwejang, Tam-ajang Murgjang, Sanagjang, Light-make up are referred in Naegagyo is included as packjang Besides we can find other make-up skills Huphwaro and Rujang from the Kaewonch onbon-wisa which was Yangkwibi's episodes. We can find the a corpus of song's words about cosmetic custom in Kor-ea. Which is 'Haecho' folk song in the souther-en costal regions 'Jinggum' folk song in Kim-hae regions and so on.... It's words is similar to Dunhuangsa in China. 3. Bichun inherited to China with India Bud-dism art in the middle of Dunhuang wall-pain-tings is one of the important Buddist saint. Sometimes it is painted with Giakchun Its arms of fly-dnacing in heaven with colored belt on body has almost the form of play on the musical instrument, We can see seasily the form in the painting of Buddist ser-mon. It was progressed and changed with the background of chinese traditional culture. When Dang's period came the color was chan-ged lighting dark blue has rhythmical and viv-id power of life. 4. Among the corpus of song's words which express the singers' system and rites of their tradition or habits. Dunhuang manuscripts des-cribes on behalf of the folk song's words in tra-ditional costume. This is following: (1) Naegagyo o sabyokwanja o Chyrasam o Rashang (2) Wangyesa o Sokryugun o Costume for fisher man (3) Bungajang of the chanboja o Ajang (4) Pongkwyun o Chongui (5) Tongsongs o Junofore (6) Namgaja o thin-Rasam (7) Yuchungnang o Hongsam o Sokryugun : The color of red costume (8) Kyongburak o Hongrasam o Sokryugun : Costume for charming woman Therefore traditional costume could be extracted according to the Dunhuang folk song's words out of culture such as learning rit-es three-obedience four-virtues and in-struction. As the same time it reflects ancient China's characteristics directly. I would endeavor to development for the history of the costume furher creative design and participat-ed in research activity with concerns forward continuously.

  • PDF

Regenerative Injection Therapy on Tendon Healing: Dextrose Prolotherapy versus Platelet-Rich Plasma

  • Jungmin Lim;Won-Jae Lee;Min-Soo Seo;Seong Mok Jeong;Sae-Kwang Ku;Youngsam Kwon;Sungho Yun
    • Journal of Veterinary Clinics
    • /
    • v.40 no.2
    • /
    • pp.93-103
    • /
    • 2023
  • The tendon is a dense connective tissue that connects muscle to bone and plays an essential role in joint motion. The injured tendon heals slowly owing to its low cellularity and vascularity. This study aimed to evaluate and compare the effects of regenerative injection therapy (RIT), 20 % dextrose prolotherapy (DP), and platelet-rich plasma (PRP) injections that can promote tendon healing. Twenty-one New Zealand white rabbits were divided into the control, DP, and PRP treatment groups. The superficial digital flexor tendon (SDFT) of the right hindlimb of each rabbit was used. A round defect of 2 mm was induced. Approximately 0.2 mL of 20% dextrose and autologous PRP were injected into the proximal and distal ends of the SDFT mass. Radiographic and ultrasonographic examination and cross-sectional area (CSA) calculations were performed pre-operatively and at 2, 4, and 8 weeks. The SDFT of both limbs was transected for biomechanical and histomorphometric evaluations. The SDFT of the left limb was transected for intact control. Semi-quantitative analysis was performed to evaluate the histomorphometric properties. Additional analysis was performed using H&E, Masson's trichrome, and immunohistochemical staining. The biomechanical evaluation showed that the treatment groups had higher tensile strength compared to the defect control group, while the PRP group had higher tensile strength than the DP group. On histological examination, the treatment groups appeared to be relatively closer to the remodeling phase of the healing process than the defect control group; the characteristics of the PRP group were closer to the remodeling phase than those of the DP group. The ultrasonographic examination showed different tendencies. Increased values in the CSA were observed during the early period in the treatment groups. This study suggests that PRP and DP can promote the healing of tendon injury, and these effects were superior with PRP than that with DP.

Feasibility study of the usefulness of SRS thermoplastic mask for head & neck cancer in tomotherapy (두경부 종양의 토모치료 시 정위적방사선수술 마스크의 유용성 평가에 대한 연구)

  • Jeon, Seong Jin;Kim, Chul Jong;Kwon, Dong Yeol;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.355-362
    • /
    • 2014
  • Purpose : When head&neck cancer radiation therapy, thermoplastic mask is applied for patients with fixed. The purpose of this study is to evaluate usefulness of thermoplastic mask for SRS in tomotherapy by conparison with the conventional mask. Materials and Methods : Typical mask(conventional mask, C-mask) and mask for SRS are used to fix body phantom(rando phantom) on the same iso centerline, then simulation is performed. Tomotherapy plan for orbit and salivary glands is made by treatment planning system(TPS). A thick portion and a thin portion located near the treatment target relative to the mask S-mask are defined as region of interest for surface dose dosimetry. Surface dose variation depending on the type of mask was analyzed by measuring the TPS and EBT film. Results : Surface dose variation due to the type of mask from the TPS is showed in orbit and salivary glands 0.65~2.53 Gy, 0.85~1.84 Gy, respectively. In case of EBT film, -0.2~3.46 Gy, 1.04~3.02 Gy. When applied to the S-mask, in TPS and Gafchromic EBT3 film, substrantially 4.26%, 5.82% showed maximum changing trend, respectively. Conclusion : To apply S-mask for tomotherapy, surface dose is changed, but the amount is insignificant and be useful when treatment target is close critical organs because decrease inter and intra fractional variation.