References
- Hogle WP. The state of the art in radiation therapy. Semin Oncol Nurs 2006;22:212-20. https://doi.org/10.1016/j.soncn.2006.07.004
- Galvin JM, Chen XG, Smith RM. Combining multileaf fi elds to modulate fluence distributions. Int J Radiat Oncol Biol Phys 1993;27:697-705. https://doi.org/10.1016/0360-3016(93)90399-G
- Mott JH, Hounsell AR, Budgell GJ, Wilkinson JM, Williams PC. Customised compensation using intensity modulated beams delivered by dynamic multileaf collimation. Radiother Oncol 1999;53:59-65. https://doi.org/10.1016/S0167-8140(99)00125-5
- Chang SX, Cullip TJ, Deschesne KM. Intensity modulation delivery techniques: "step & shoot" MLC auto-sequence versus the use of a modulator. Med Phys 2000;27:948-59. https://doi.org/10.1118/1.598989
- Keall PJ, Mageras GS, Balter JM, et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 2006;33:3874-900. https://doi.org/10.1118/1.2349696
- Li XA, Keall PJ, Orton CG. Point/counterpoint: respiratory gating for radiation therapy is not ready for prime time. Med Phys 2007;34:867-70. https://doi.org/10.1118/1.2514027
- Zygmanski P, Kung JH, Jiang SB, Choi N, Chen G. Is IMRT of lung possible without respiratory gating? Clinical evaluation of a true dose received by a moving target volume. Int J Radiat Oncol Biol Phys 2001;51(3 suppl 1):27. https://doi.org/10.1016/S0360-3016(01)01871-5
- Kung JH, Zygmanski P, Kooy H, Chen G. Dose error in IMRT treatment of lung cancer without respiratory gating. Int J Radiat Oncol Biol Phys 2000;48(3 suppl 1):344
- Li X, Zhang P, Helminen H, Gewanter R, Kutcher GJ. Comparison of different respiratory motion compensation methods for lung cancer IMRT treatment. Int J Radiat Oncol Biol Phys 2005;63 Suppl 1:S564. https://doi.org/10.1016/j.ijrobp.2005.07.949
- Duan J, Shen S, Fiveash JB, Popple RA, Brezovich IA. Dosimetric and radiobiological impact of dose fractionation on respiratory motion induced IMRT delivery errors: a volumetric dose measurement study. Med Phys 2006;33:1380-7. https://doi.org/10.1118/1.2192908
- Lujan AE, Larsen EW, Balter JM, Ten Haken RK. A method for incorporating organ motion due to breathing into 3D dose calculations. Med Phys 1999;26:715-20. https://doi.org/10.1118/1.598577
- Shin E, Park HC, Han Y, Ju SG, Shin JS, Ahn YC. Effi cacy of a respiratory training system on the regularity of breathing. J Korean Soc Ther Radiol Oncol 2008;26:181-8. https://doi.org/10.3857/jkstro.2008.26.3.181
- Cuijpers JP, Underberg RW, Lagerwaard FJ, Senan S, Sletman BJ. Penumbra broadening due to respiratory motion: an analysis of 4D clinical datasets. Radiat Oncol 2004;73(Suppl 1):S128.
- Bortfeld T, Jokivarsi K, Goitein M, Kung J, Jiang SB. Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. Phys Med Biol 2002;47:2203-20. https://doi.org/10.1088/0031-9155/47/13/302
Cited by
- Dosimetric evaluation of a moving tumor target in intensity-modulated radiation therapy (IMRT) for lung cancer patients vol.63, pp.1, 2013, https://doi.org/10.3938/jkps.63.67
- Evaluation of radiation dose to organs during kilovoltage cone‐beam computed tomography using Monte Carlo simulation vol.15, pp.2, 2011, https://doi.org/10.1120/jacmp.v15i2.4556
- Optimization of beam orientation and virtual organ delineation for lung IMRT vol.64, pp.7, 2014, https://doi.org/10.3938/jkps.64.1047
- Combination effects of tissue heterogeneity and geometric targeting error in stereotactic body radiotherapy for lung cancer using CyberKnife vol.16, pp.5, 2011, https://doi.org/10.1120/jacmp.v16i5.5397
- Feasibility study of the neutron dose for real-time image-guided proton therapy: A Monte Carlo study vol.67, pp.1, 2015, https://doi.org/10.3938/jkps.67.142
- Secondary Neutron Dose Measurement for Proton Line Scanning Therapy vol.27, pp.3, 2011, https://doi.org/10.14316/pmp.2016.27.3.162
- Monte Carlo simulation of secondary neutron dose for scanning proton therapy using FLUKA vol.12, pp.10, 2011, https://doi.org/10.1371/journal.pone.0186544
- Dosimetric analysis on the effect of tumor motion in IMRT for liver cancer: comparison of TomoTherapy and VMAT using the Delta4 Hexa-Motion system vol.79, pp.5, 2011, https://doi.org/10.1007/s40042-021-00150-x