• Title/Summary/Keyword: Ring Finger

Search Result 140, Processing Time 0.035 seconds

A Tunable Digital Tourniquet Using Nelaton Catheter (고무 도뇨관을 이용한 간단한 수지 지혈대)

  • Kim, Sang Wha;Yim, Young Min;Jung, Sung No;Kwon, Ho
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.759-761
    • /
    • 2008
  • Purpose: Surgery on digit requires a clear, bloodless field and it can be achieved by using a tourniquet. Several type of tourniquet have been used including Penrose drains and sterile glove with hemostat. We present a simple digital tourniquet using nelaton catheter, which is easily available, inexpensive, easy-to-apply, and effective for digital surgery. Methods: We made a small incision on the opposite side of an opening at the tip of nelaton catheter. Then the other tip of nelaton catheter is passed through the incision to form a ring. Nelaton catheter is placed aournd the base of the injured finger, making a tight circle to desired pressure. Results: A simple tourniquet using nelaton catheter effectively achieves a bloodless field and allows fine control of the pressure for digital surgery. Conclusion: We present a sismple digital tourniquet using nelaton catheter, which is easily available, inexpensive, tunable, and available for more than one finger.

Cloning and Expression Analysis of a Novel Mouse Zinc Finger Protein Gene Znf313 Abundantly Expressed in Testis

  • Li, Na;Sun, Huaqin;Wu, Qiaqing;Tao, Dachang;Zhang, Sizhong;Ma, Yongxin
    • BMB Reports
    • /
    • v.40 no.2
    • /
    • pp.270-276
    • /
    • 2007
  • We have cloned a novel mouse zinc finger protein gene Znf313 by rapid amplification of cDNA ends (RACE) according to the homologue of human ZNF313 gene. The cDNA is 2,163 base pairs (bp) in length and encodes a 229 amino acids (aa) protein with a $C_3HC_4$ ring finger domain and three $C_2H_2$ domains. 89% and 93% nucleotide (nt) and aa sequence identity is observed with its human homologue. Revealed by Northern blot and RT-PCR, full mRNA consists of 2.16 kb and widely expresses in tissues as a single transcript, most abundantly in heart, liver, kidney and testis. The expression of Znf313 in testis is detected in all development stages. Western blot analysis also reveals that Znf313 is expressed in the tissues. Immunohistochemical staining and subcellular localization demonstrate that Znf313 is expressed both in the cytoplasm and nucleus whereas predominantly localized in the nucleus. Present data suggests that Znf313 gene might play a fundamental role in gene transcription and regulation in organism and relates to spermatogenesis.

Comparison of Maximum Fingertip Force Distribution in Cylindrical Grasping Between Healthy Adults and Patients With Spinal Cord Injury (원통형 물체 쥐기 시 건강한 성인과 척수마비 환자의 최대 손가락 끝 힘 분포 비교)

  • Hwang, Jisun;Ree, Jae Sun;Hwang, Seonhong
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.28-36
    • /
    • 2022
  • Background: It is known that hand strength and fingertip force are used as an indicator of muscle strength and are also highly related to the various chronic symptoms and even lifespan. To use the individual fingertip force (IFF) as a quantitative index for clinical evaluation, the IFF should be measured and analyzed with various variables from various subjects, such as the normal range of fingertip force and the difference in its distribution by disease. Objects: We tried to measure and analyze the mean maximum IFF distribution during grasping a cylindrical object in healthy adults and patients with spinal cord injury (SCI). Methods: Five Force-sensitive resistor (FSR) sensors were attached to the fingertips of 24 healthy people and 13 patients with SCI. They were asked to grip the object three times for five seconds with their maximum effort. Results: The mean maximum IFF of the healthy adult group's thumb, index, and middle finger was similar statistically and showed relatively larger than IFF of the ring and small finger. It is a 3-point pinch grip pattern. All fingertip forces of patients with SCI decreased by more than 50% to the healthy group, and their IFF of the middle finger was relatively the largest among the five fingertip forces. The cervical level injured SCI patients showed significantly decreased IFFs compared to thoracic level injured SCI patients. Conclusion: We expect that this study results would be helpful for rehabilitation diagnosis and therapy goal decision with robust further study.

Low-cost Prosthetic Hand Model using Machine Learning and 3D Printing (머신러닝과 3D 프린팅을 이용한 저비용 인공의수 모형)

  • Donguk Shin;Hojun Yeom;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.19-23
    • /
    • 2024
  • Patients with amputations of both hands need prosthetic hands that serve both cosmetic and functional purposes, and research on prosthetic hands using electromyography of remaining muscles is active, but there is still the problem of high cost. In this study, an artificial prosthetic hand was manufactured and its performance was evaluated using low-cost parts and software such as a surface electromyography sensor, machine learning software Edge Impulse, Arduino Nano 33 BLE, and 3D printing. Using signals acquired with surface electromyography sensors and subjected to digital signal processing through Edge Impulse, the flexing movement signals of each finger were transmitted to the fingers of the prosthetic hand model through training to determine the type of finger movement using machine learning. When the digital signal processing conditions were set to a notch filter of 60 Hz, a bandpass filter of 10-300 Hz, and a sampling frequency of 1,000 Hz, the accuracy of machine learning was the highest at 82.1%. The possibility of being confused between each finger flexion movement was highest for the ring finger, with a 44.7% chance of being confused with the movement of the index finger. More research is needed to successfully develop a low-cost prosthetic hand.

The Transmit Method for Fingerprint sensing using Differential Pulse in Mutual Capacitance Touch Screen Panel for improving security of computer information (컴퓨터의 보안향상을 위한 상호정전용량 터치스크린패널의 차동펄스를 이용한 지문인식을 위한 송신법)

  • Kim, Seong Mun;Choi, Eun Ho;Ko, Nak Young;Bien, Franklin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.55-60
    • /
    • 2017
  • This paper is proposed on the transmit Method Finger-Printer Scanning of Mutual Capacitance Touch Screen Panel Using Differential Pulse for improving the security of computer information. This system is composed of differential pulse generator and Ring-Counter, also Supply voltage is 5V. this system generates the Pulse wave which is composed of In-Phase and Out of Phase at 1MHz while period of 2m/s. it is designed and be able to operate four channels. overall power consumption is approximately 78.08nW. This prototype is implemented in 0.25um CMOS Process and Chip area is $870um{\times}880um$.

Schizosaccharomyces pombe rsml Genetically Interacts with spmex67, Which Is Involved in mRNA Export

  • Yoon, Jin-Ho
    • Journal of Microbiology
    • /
    • v.42 no.1
    • /
    • pp.32-36
    • /
    • 2004
  • We have previously isolated three synthetic lethal mutants from Schizosaccharomyces pombe in order to identify mutations in the genes that are functionally linked to spmex67 with respect to mRNA export. A novel rsm1 gene was isolated by complementation of the growth defect in one of the synthetic lethal mutants, SLMex1. The rsml gene contains no introns and encodes a 296 amino-add-long protein with the RING finger domain, a C3HC4 in the N-terminal half. The Δrsm1 null mutant is viable, but it showed a slight poly(A)$\^$+/ RNA accumulation in the nucleus. Also, the combination of Δrsm1 and Δspmex67 mutations confers synthetic lethality that is accompanied by the severe poly(A)$\^$+/ RNA export defect. These results suggest that rsm1 is involved in mRNA export from the nucleus.

Fabrication of Schottky diodes for RFID tag integration using Standard $0.18{\mu}m$ CMOS process (RFID tag 집적화를 위한 $0.18{\mu}m$ 표준 CMOS 공정을 이용한 쇼트키 다이오드의 제작)

  • Shim, Dong-Sik;Min, Young-hun
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.591-592
    • /
    • 2006
  • Schottky diodes for Radio-frequency identification (RFID) tag integration on chip were designed and fabricated using Samsung electronics System LSI standard $0.18{\mu}m$ CMOS process. Schottky diodes were designed as interdigitated fingers array by CMOS layout design rule. 64 types of Schottky diode were designed and fabricated with the variation of finger width, length and numbers with a $0.6{\mu}m$ guard ring enclosing n-well. Titanium was used as Schottky contact metal to lower the Schottky barrier height. Barrier height of the fabricated Schottky diode was 0.57eV. DC current - voltage measurements showed that the fabricated Schottky diode had a good rectifying properties with a breakdown voltage of -9.15 V and a threshold voltage of 0.25 V.

  • PDF

The Onset and Duration of Action of 0.2% Lidocaine in a One-per-Mil Tumescent Solution for Hand Surgery

  • Prasetyono, Theddeus O.H.;Lestari, Puri A.
    • Archives of Plastic Surgery
    • /
    • v.43 no.3
    • /
    • pp.272-277
    • /
    • 2016
  • Background One-per-mil tumescent solution, which contains 0.2% lidocaine with 1:1,000,000 epinephrine, has been reported to be clinically effective for hand surgery under local anesthesia. However, it was lacking in its basic pharmacokinetics profile in regard to the onset of action (OOA) and duration of action (DOA). Methods A randomized, double-blind study was conducted on 12 volunteers who met the inclusion criteria from October to November 2014. All volunteers had their right and left ring finger pulps injected with either one-per-mil solution or 2% lidocaine. Semmes-Weinstein and two-point discrimination tests were used to test sensation. Visual analogue scale was recorded at the time when the finger lost its sensation and when it regained normal sensation to measure the OOA and DOA. The data were then analyzed with a paired t-test and a Wilcoxon signed-rank test. Results The OOA and DOA of 2% plain lidocaine were 1 minute and 99.67 minutes, respectively. Meanwhile, 0.2% lidocaine in a one-per-mil tumescent solution showed an OOA of 5 minutes and a DOA of 186.83 minutes. The OOA of 0.2% lidocaine in a one-per-mil tumescent solution is statistically shorter than 2% plain lidocaine (P=0.04); while its DOA is statistically longer than 2% plain lidocaine (P<0.001). Conclusions The 0.2% lidocaine in a one-per-mil tumescent solution is statistically and clinically superior to 2% plain lidocaine in achieving longer duration of local anesthesia.

Second to Fourth Digit Ratio and Sexually Dimorphic Body Composition (손가락 길이 비율과 남녀 체형과의 상관성)

  • Park, Jung-Hyun;Song, Mi-Young;Kim, Ho-Jun;Lee, Myeong-Jong
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.10 no.1
    • /
    • pp.41-48
    • /
    • 2010
  • Background The length of the second digit (the index finger) relative to the length of the fourth digit (the ring finger) is sexually dimorphic as males have a lower second to fourth digit ratio (2D:4D). There is evidence that sex differences in 2D:4D arise from in utero concentrations of sex steroids, with a low 2D:4D (male typical ratio) being positively related to prenatal testosterone, while a high 2D:4D (female typical ratio) is positively associated with prenatal oestrogen Objective To investigate possible associations between 2D:4D ratio and sexually dimorphic body composition Methods 2D:4D ratio, body mass index (BMI), waist circumference, waist-hip ratio (WHR), weight, and body fat percentage was measured from 46 men and 20 women Results Digit ratio was found to be significantly lower in men than in women. No significant correlation between 2D:4D ratio and body compositions was found for both men and women while digit ratio in obese men was significantly higher than normal weight men. Conclusion This finding dose not support the significant correlation between digit ratio and sexually dimorphic body composition. However digit ratio in obese men was significantly higher than normal weight men.

Development of the Caliper System for a Geometry PIG Based on Magnetic Field Analysis

  • Kim, Dong-Kyu;Cho, Sung-Ho;Park, Seoung-Soo;Yoo, Hui-Ryong;Park, Yong-Woo;Kho, Young-Tai;Park, Gwan-Soo;Park, Sang-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.1835-1843
    • /
    • 2003
  • This paper introduces the development of the caliper system for a geometry PIG (Pipeline Inspection Gauge). The objective of the caliper system is to detect and measure dents, wrinkles, and ovalities affect the pipe structural integrity. The developed caliper system consists of a finger arm, an anisotropic permanent magnet, a back yoke, pins, pinholes and a linear hall effect sensor. The angle displacement of the finger arm is measured by the change of the magnetic field in sensing module. Therefore the sensitivity of the caliper system mainly depends on the magnitude of the magnetic field inside the sensing module. In this research, the ring shaped anisotropic permanent magnet and linear hall effect sensors were used to produce and measure the magnetic field. The structure of the permanent magnet, the back yoke and pinhole positions were optimized that the magnitude of the magnetic field range between a high of 0.1020 Tesla and a low of zero by using three dimensional nonlinear finite element methods. A simulator was fabricated to prove the effectiveness of the developed caliper system and the computational scheme using the finite element method. The experimental results show that the developed caliper system is quite efficient for the geometry PIG with good performance.