• 제목/요약/키워드: Rice-Husk

검색결과 233건 처리시간 0.025초

우드세라믹을 첨가한 기능성 한지가 실내습도 조절에 미치는 영향 (Effect of Functional Hanji Using Wood Ceramics on Indoor Humidity Control)

  • 임현아;오승원;강진하
    • 펄프종이기술
    • /
    • 제38권2호
    • /
    • pp.35-42
    • /
    • 2006
  • This study was carried out to develop a new application field of traditional Hanji and obtain the basic data for producing functional Hanji using sawdust ceramics and rice-husk ceramics as an architectural material. The results measuring water vapor permeance and water vapor absorption for using window materials and wallpapers are as follows. Hanji wallpaper has good things in controlling indoor space comfortably. Particularly, ability of controlling humidity of Hanji wallpaper affects indoor space comfort and human health. In the case indoor humidity is higher than outdoor humidity, according to the addition of ceramics, Hanji wallpapers maintain the humidity by retaining water vapor molecules in the pores of ceramics. Thus the Hanji wallpapers with ceramics, in particular rice-husk ceramics, make it superior to non-ceramics Hanji wallpapers in maintaining the humidity indoors.

Chloride penetration resistance of concrete containing ground fly ash, bottom ash and rice husk ash

  • Inthata, Somchai;Cheerarot, Raungrut
    • Computers and Concrete
    • /
    • 제13권1호
    • /
    • pp.17-30
    • /
    • 2014
  • This research presents the effect of various ground pozzolanic materials in blended cement concrete on the strength and chloride penetration resistance. An experimental investigation dealing with concrete incorporating ground fly ash (GFA), ground bottom ash (GBA) and ground rice husk ash (GRHA). The concretes were mixed by replacing each pozzolan to Ordinary Portland cement at levels of 0%, 10%, 20% and 40% by weight of binder. Three different water to cement ratios (0.35, 0.48 and 0.62) were used and type F superplasticizer was added to keep the required slump. Compressive strength and chloride permeability were determined at the ages of 28, 60, and 90 days. Furthermore, using this experimental database, linear and nonlinear multiple regression techniques were developed to construct a mathematical model of chloride permeability in concretes. Experimental results indicated that the incorporation of GFA, GBA and GRHA as a partial cement replacement significantly improved compressive strength and chloride penetration resistance. The chloride penetration of blended concrete continuously decreases with an increase in pozzolan content up to 40% of cement replacement and yields the highest reduction in the chloride permeability. Compressive strength of concretes incorporating with these pozzolans was obviously higher than those of the control concretes at all ages. In addition, the nonlinear technique gives a higher degree of accuracy than the linear regression based on statistical parameters and provides fairly reasonable absolute fraction of variance ($R^2$) of 0.974 and 0.960 for the charge passed and chloride penetration depth, respectively.

Updraft 고정층 가스화 시스템에서의 왕겨 가스화 합성가스 정제특성 (Characteristics of Syngas Refinery via Rice Husk Gasification in the Updraft Fixed-bed Gasification System)

  • 윤영식;성호진;박수남;구재회
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.171.2-171.2
    • /
    • 2011
  • 지속가능한 발전과 저탄소 녹색성장의 개념이 대두되면서 우리나라를 비롯한 주요 선진국은 자국의 화석연료 의존도를 낮추고 대체에너지로 환경친화적이며, 청정에너지로 각광받는 신 재생에너지의 활용에 경제적, 정책적 지원을 아끼지 않고 있는 실정이다. 실제로 유럽에서는 바이오매스의 일종인 우드칩을 활용한 가정용 보일러가 보급되고 있으며, 동남아시아에서는 열대식물을 이용한 저온열분해를 활용하여 바이오디젤을 생산하고 있다. 우리나라의 경우 대부분의 바이오매스는 발생되는 임야에서 재이용되거나 경제성이 있을 경우에 운송되어 재활용되고 있으며, 임부목과 같은 일부 바이오매스는 수익성이 없어 발생현지에 방치되는 경우도 있다. 본 연구에서 주목한 왕겨의 경우 미곡종합처리장에서 대량으로 발생되지만 그 활용도에 있어서 축적된 바이오에너지에 비해 에너지회수율이 저조하다고 할 수 있다. 왕겨는 임야에서 발생되는 폐목재나 다른 바이오매스에 비해 함유되어 있는 수분이 적고(12%), 휘발분의 함량이 많으며(58%), 고정탄소(17%), 회분(13%)로 열분해/가스화에 적용가능하다. 본 실험에서 생산된 합성가스의 활용방법으로는 보일러를 이용한 스팀 및 전력생산, 가스엔진을 이용한 전력생산, 폐열회수 등이 있으며 생산된 합성가스를 활용하기 위해서는 오염물질의 정제특성에 대한 연구가 선행되어야 한다. 따라서 본 연구에서는 합성가스 내에 존재하는 분진, 타르, HCl, HCN, $NH_3$의 제거효율을 조사하였다.

  • PDF

왕겨재를 혼입한 콘크리트의 동결융해 저항성에 관한 실험적 연구 (An Experimental Study on the Resistance of Concrete Included Rice Husk Ash Against Rapid Freezing and Thawing)

  • 이준구;박광수;이응찬;김한중
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.294-300
    • /
    • 1999
  • After researching the physical properties of the concrete included Rice Husk Ash(RHA concrete) and workability of fresh concrete admixed RHA, we have tested durability of RHA-concrete against freeaing and thawing in the winter using rapid freezing and thawing test method(KS F 2456) . There aretwo hypotheses to explain the failure mechanism of a freezing and thawing action. First, the hydraulic pressure in the pores of freezing concrete make an internal stress of concrete structures outbreaking micro crack in the face of concrete, Second, Frost action causing damage to cement paste repeatedly come from soil frost action, freezing water in the capillaries. Initial Relative Dynamic Modulus of Elasticity (DME) was biggest in cae of unit binder weight 600kgf/㎥ and relative dynamic modulus of elasticity increased until 300cycles. In general , initial relative DME was proportional to unit binder weight . Relative DME was decreased in proportion to unit binder weight in the case of 300, 400, 500kgf/㎥ , but relative DME fo the others remained more than 90% until 300 cycles. It was not good effect of intermixed RHA to concrete in case of below unit binder weight 300kgf/㎥ and the resistance of freezing and thawing was not good either.

  • PDF

Experimental study on geopolymer concrete prepared using high-silica RHA incorporating alccofine

  • Parveen, Parveen;Singhal, Dhirendra;Jindal, Bharat Bhushan
    • Advances in concrete construction
    • /
    • 제5권4호
    • /
    • pp.345-358
    • /
    • 2017
  • This paper describes the experimental investigation carried out to develop geopolymer concrete using rice husk ash (RHA) along with alccofine. The study reports the fresh and hardened properties of the geopolymer concrete (GPC) activated using alkaline solution. GPC were prepared using different RHA content (350, 375 and $400kg/m^3$), the molarity of the NaOH (8, 12 and 16M). The specimens were cured at $27^{\circ}C$ and $90^{\circ}C$. GPC was activated using NaOH, $Na_2SiO_3$, and alccofine. Prepared GPC samples were tested for compressive and splitting tensile strengths after 3, 7 and 28 days. RHA was suitable to produce geopolymer concrete. Results indicate that behavior of GPC prepared with RHA is similar to fly ash based GPC. Workability and strength can be improved by incorporating the alccofine. Further, alccofine and heat curing improve the early age properties of the GPC. Heat curing is responsible for the initial polymerization of GPC which leads to high workability and improved mechanical properties of the GPC. High strength can be achieved by using the high concentration alkaline solution in terms of molarity and at elevated heat curing. Further, RHA based geopolymer concrete has tremendous potential as a substitute for ordinary concrete.

왕겨의 heat flux별 연소특성에 관한 연구 (Combustion characteristics of rice-husk according to the change of heat flux)

  • 박은영;박덕신;조영민;박병현;이철규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1190-1195
    • /
    • 2005
  • Biomass burning is a source of greenhouse gases, carbon dioxide, methane, and nitrous oxide. Under the ideal conditions of complete combustion, the burning of biomass produces carbon dioxide and water vapor. Since complete combustion is not achieved under any conditions of biomass burning, other carbon species, including carbon monoxide, methane, non-methane hydrocarbons and particulate carbon are produced. In this study, we analyze the combustion characteristics of rice-husk, such as heat release rate, smoke production rate, the percentage variation of CO and $CO_2$, oxygen consumption rate, and mass loss under different heat fluxes (20, 50 and 70kW). As a result, at 20kW incomplete combustion is occurred so that the percentage of CO is high in initial burning and total smoke release is higher than the others. At 50kW and 70kW, the combustion behaviors is very similar except the variation of CO percentage.

  • PDF

미세금속입자의 루멘충전 특성평가 (Evaluation of Lumen-loaded Fiber with Micro Metal Particles)

  • 성용주;정웅기;이지영
    • 펄프종이기술
    • /
    • 제44권4호
    • /
    • pp.99-107
    • /
    • 2012
  • In this study, the lumen loading technology for preparing magnetic papers were evaluated. The rice husk fiber, softwood kraft pulp, hardwood kraft pulp were applied and the morphological properties of pits on the those fibers were investigated with SEM. The softwood kraft pulp had the bigger size of pits, $3{\sim}5{\mu}m$ in diameter, which resulted in higher loading amount. The comparison of two methods for lumen loading such as the low concentration method with the disintegrator and the high concentration method with the Hobart mixer showed the Hobart mixer could resulted in the higher efficiency. The conditions of lumen loading process such loading time, addition amount of metal particles and addition of PEI were also evaluated. The magnetic hysteresis loop of handsheet samples made of lumen loaded fiber with $Fe_3O_4$ and $Fe_2O_3$ were examined. The differences in magnetic properties could be found according to the ferrite types.

Latent Heat of Water Vapor of Rough Rice, Brown Rice, White Rice and Rice Husk

  • Lee, Hyo-Jae;Kim, Dong-Chul;Kim, Oui-Woung;Han, Jae-Woong;Kim, Woong;Kim, Hoon
    • Journal of Biosystems Engineering
    • /
    • 제36권4호
    • /
    • pp.267-272
    • /
    • 2011
  • The latent heat of vaporization in rough rice, brown rice, white rice and rice hull was calculated by Clausius-Clapeyron equation, which does not require complex constraints as in Othmer method. Equilibrium relative humidity and ratio of the latent heat of vaporization with ln$P_{\upsilon}$ and ln$P_S$ were estimated with moisture contents ranging from 10% (d.b.) to 36% (d.b.) with 2% (d.b.) increment and temperatures ranging from $10^{\circ}C$ to $50^{\circ}C$ with $2.5^{\circ}C$ increment. An empirical equation for calculating the latent heat of vaporization in rice was developed as a function of moisture content and temperature. The equation agreed well with the calculated results. The ratio for latent heat of vaporization were the greatest for white rice while they were similar among rough rice, brown rice and rice hull.

Formaldehyde Deodorization Effect and Far-Infrared Emission Characteristics of Ceramics Prepared with Sawdust, Risk Husk, and Charcoal: Effect of Material Mixing Ratio

  • HWANG, Jung-Woo;OH, Seung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • 제50권2호
    • /
    • pp.104-112
    • /
    • 2022
  • Indoor air quality is a very important environmental factor in modern society. However, air pollutants generated from various interior construction materials significantly affect the human body, including formaldehyde (HCHO) and volatile organic compounds that threaten public health by deteriorating indoor air quality. Effective in removing these harmful substances are porous materials, such as woodceramics. In this study, charcoal, a porous material, was added to rice husk, an agricultural by-product, and sawdust generated during the sawing process to prepare boards and ceramics at different mixing ratios, and the HCHO deodorization performance and far-infrared emission characteristics were measured. As the mixing ratio of charcoal increased, the deodorization rate of the boards and ceramics tended to increase. Overall, the deodorization rate was measured to be 80% to 90%, indicating that the boards and ceramics prepared with charcoal are suitable to be used for the purpose of deodorization. The effect of the material mixing ratio on far-infrared emissivity and emission power was insignificant.

Combustion Characteristics of a Hot Water Boiler System Convertibly Fueled by Rice Husk and Heavy Oil - Heavy Oil Combustion Characteristics -

  • Kim, Myoung Ho;Kim, Dong Sun;Park, Seung Je
    • Journal of Biosystems Engineering
    • /
    • 제38권4호
    • /
    • pp.306-311
    • /
    • 2013
  • Purpose: With the ever-rising energy prices, thermal energy heavily consuming facilities of the agricultural sector such as commercialized greenhouses and large-scale Rice Processing Complexes (RPCs) need to cut down their energy cost if they must run profitable businesses continually. One possible way to reduce their energy cost is to utilize combustible agricultural by-products or low-price oil instead of light oil as the fuel for their boiler systems. This study aims to analyze the heavy oil combustion characteristics of a newly developed hot water boiler system that can use both rice husk and heavy oil as its fuel convertibly. Methods: Heavy oil combustion experiments were conducted in this study employing four fuel feed rates (7.6, 8.5, 9.5, 11.4 $l/h$) at a combustion furnace vacuum pressure of 500 Pa and with four combustion furnace vacuum pressures (375, 500, 625, 750 Pa) at fuel feed rates of 9.5 and 11.4 $l/h$. Temperatures at five locations inside the combustion furnace and 20 additional locations throughout the whole hot water boiler system were measured to ascertain the combustion characteristics of the heavy oil. From the temperature measurement data, the thermal efficiency of the system was calculated. Flue gas smoke density and concentrations of air-polluting components in the flue gas were also measured by a gas analyzer. Results: As the fuel feed rate or combustion furnace vacuum pressure increased, the average temperature in the combustion furnace decreased but the thermal efficiency of the system showed no distinctive change. On the other hand, the thermal efficiency of the system was inversely proportionally to the vacuum level in the furnace. For all experimental conditions, the thermal efficiency remained in the range of 80.1-89.6%. The CO concentration in the flue gas was negligibly low. The NO and $SO_2$ concentration as well as the smoke density met the legal requirements. Conclusions: Considering the combustion temperature characteristics, thermal efficiency, and flue gas composition, the optimal combustion condition of the system seemed to be either the fuel feed rate of 9.5 $l/h$ with a combustion furnace vacuum pressure of 375 Pa or a fuel feed rate of 11.4 $l/h$ with a furnace vacuum pressure between 500 Pa and 625 Pa.