• Title/Summary/Keyword: Rib angle

Search Result 115, Processing Time 0.025 seconds

Rib Effect of Deformation on Bond Strength (부착강도에 대한 이형철근의 마디형상 영향)

  • Park, Young-Su;Yang, Seung-Yul;Kim, Byoung-Kook;Hong, Gi-Suop;Choi, Oan-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.209-212
    • /
    • 2006
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. The effects of defomation properties on bond of reinforcing bars to concrete are studied. Beam-end tests are used to investigate the effects of machining of bars in addition to rib angle and relative rib area. The test results show that bond strength of machined bars were higher than the conventional bars produced in factory. Higher rib height bars with rib angle $30^{\circ}{\sim}60^{\circ}$ showed higher bond strength than lower rib height bars with low angle.

  • PDF

Effects of Duct Aspect Ratios on Heat/Mass Transfer With Discrete V-Shaped Ribs (쐐기형 단락요철이 설치된 덕트의 종횡비가 열/물질 전달에 미치는 영향)

  • Lee, Dong-Hyun;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1453-1460
    • /
    • 2003
  • The present study investigates the effects of rib arrangements and aspect ratios of a rectangular duct simulating the cooling passage of a gas turbine blade. Two different V-shaped rib configurations are tested with the aspect ratios (W/H) of 3 to 6.82. One is the continuous V-shaped rib configuration with $60^{\circ}$ attack angle, and the other is the discrete V-shaped rib configuration with $45^{\circ}$ attack angle. The square ribs with the pitch to height ratio of 10.0 are installed on the test section in a parallel arrangement for both rib configurations. Reynolds numbers based on the hydraulic diameter are changed from 10,000 to 30,000. A naphthalene sublimation method is used to measure local heat/mass transfer coefficients. For the continuous V-shaped rib configuration, two pairs of counter-rotating vortices are generated in a duct, and high transfer region is formed at the center of the ribbed walls of the duct. However, for the discrete V-shaped rib configuration with $45^{\circ}$ attack angle, complex secondary flow patterns are generated in the duct due to its geometric feature, and more uniform heat/mass transfer distributions are obtained for all tested cases

  • PDF

Roles of Bearing Angle in Bond Action of Reinforcing Bars to Concrete

  • Choi OanChul
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.719-724
    • /
    • 2004
  • The ribs of deformed bars can split the cover concrete by wedging action or shear off the concrete in front of the ribs. As slip of deformed bars increases, the rib face angle is flattened by the crushed concrete wedge, which reduces the rib face angle to a smaller bearing angle. The roles of bearing angle are explored to simulate this observation. Analytical expressions to determine bond strength for splitting and pullout failure are derived, where the bearing angle is a key variable. As the bearing angle is reduced, splitting strength decreases and shearing strength increases. When splitting strength becomes larger than shearing strength, the concrete key is supposed to be sheared off and the bearing angle is reduced with decreasing the splitting strength. As bars slip, bearing angle decreases continually so that splitting bond strength is maintained to be less than shearing bond strength. The bearing angle is found to play a key role in controlling the bond failure and determination of bond strength of ribbed reinforcing steel in concrete structures.

Cyclic behavior of steel beam-to-column connections with novel strengthened angle components

  • Kang, Lan;Zhang, Cheng
    • Steel and Composite Structures
    • /
    • v.42 no.6
    • /
    • pp.791-804
    • /
    • 2022
  • As a type of semi-rigid connection, the top and seat angle connections are popular in current structures owing to their good cyclic performance and simple erection. However, their stiffness and load bearing capacity are relatively insufficient. This study proposes two strengthening methods to further increase the stiffness and strength of bolted-angle joints while maintaining satisfactory energy dissipation capacity (EDC) and ductility. Cyclic loading tests were conducted on six joint specimens with different strengthened angle components. Based on the test results, the influence of the following important factors on the cyclic behavior of steel joint specimens was investigated: the position of the rib stiffeners (edge rib stiffeners and middle rib stiffener), steel strength grade of rib stiffeners (Q345 and Q690), and additional stiffeners or not. In addition, the finite element models of these specimens were built and validated through a comparison of experimental and numerical results. The stiffness and bearing capacity of the bolted-angle joints could be improved significantly by utilizing the novel strengthened joints proposed in this study. Moreover, this can be achieved with almost no increase in the amount of steel required, and the EDC of this joint could also satisfy the requirements of seismic codes from various countries.

Augmented heat transfer in a rectangular duct with angled ribs (사각 덕트내 요철의 각도 변화에 따른 열전달 특성)

  • U, Seong-Je;Kim, Wan-Sik;Jo, Hyeong-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.530-541
    • /
    • 1998
  • Heat transfer augmentation in a rib-roughened duct is affected by the rib configurations, such as rib height, angle of attack, shape, rib to rib pitch, and aspect ratio of a duct. These have been the main subjects in studying the average heat transfer and the friction loss of the fully developed flow. Investigating distributions of local heat transfer coefficients and flow patterns in a duct with the rib turbulators is necessary to find the characteristics of heat transfer augmentation and to decide the optimal configurations of ribs. In the present study the numerical analyses and the mass transfer experiments are performed to understand the flow through a rib roughened duct and the heat transfer characteristics with various angles of attack of ribs. A pair of counter-rotating secondary flow in a duct has a main effect on the lateral distributions of local mass transfer coefficients. Downwash of the rotating secondary flow, reattachment of main flow between ribs and the vortices near ribs and wall enhanced the mass transfer locally up to 8 times of that in case of the duct without ribs.

Heat/Mass Transfer and Friction Characteristic in a Square Duct with Various Discrete Ribs -In-Lined Gap Arrangement Ribs- (덕트내 요철의 단락위치 변화에 따른 열/물질전달 및 압력강하 특성 - 정렬 단락배열 요철 -)

  • Lee, Sei-Young;Choi, Chung;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1640-1649
    • /
    • 2001
  • The present study investigates the effects of various rib arrangements on heat/mass transfer in the cooling passage of gas turbine blades. A complex flow structure occurs in the cooling passage with rib turbulators which promote heat transfer on the wall. It is important to increase not only the heat transfer rates but also the uniformity of heat transfer in the cooling passage. A numerical computation is performed using a commercial code to calculate the flow structures and experiments are conducted to measure heat/mass transfer coefficients using a naphthalene sublimation technique. A square channel (50 mm $\times$ 50 mm) with rectangular ribs (4 mm $\times$ 5 mm) is used fur the stationary duct test. The experiments focus on the effects of rib arrangements and gap positions in the discrete ribs on the heat/mass transfer on the duct wall. The rib angle of attack is 60°and the rib-to-rib pitch is 32 mm, that is 8 times of the rib height. With the inclined rib angle of attack (60°), the parallel rib arrangements make a pair of counter rotating secondary flows in the cross section, but the cross rib arrangements make a single large secondary flow including a small secondary vortex. These secondary flow patterns affect significantly the heat/mass transfer on the ribbed wall. The heat/mass transfer in the parallel arrangements is 1.5 ∼2 times higher than that in the cross arrangements. However, the shifted rib arrangements change little the heat/mass transfer from the inline rib arrangements. The gap position in the discrete rib affects significantly the heat/mass transfer because a strong flow acceleration occurs locally through the gap.

Optimization of the Channel of a Plate Heat Exchanger wits Ribs (리브가 있는 판형 열교환기 관내부 최적화)

  • 이관수;양동근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.3
    • /
    • pp.199-205
    • /
    • 2002
  • In this paper, the optimum shape and arrangement of ribs in the channel of a plate heat exchanger are studied. The following dimensionless geometric parameters of ribs are selected as design variables: rib height ($H_R$), angle of attack ($\beta$), rib pitch ($P_R$), rib distance (L) and aspect ratio of rib (AR). The optimization is performed by minimizing the objective function consisting of the Nusselt number and the friction factor. The optimal values of design variables are as follows: $H_R$=0.263, $\beta$=0.290, $P_R$=3.142, L: 3.954, AR=0.342. The pressure drop and the heat transfer of the optimum model, compared to those of the reference model, are increased by 15.1% and 41.6%, respectively.

A numerical study on the analysis of behavior characteristics of inclined tunnel considering the optimum direction of steel rib (강지보재 최적 설치방향을 고려한 경사터널의 거동특성에 대한 수치해석적 연구)

  • Park, Sang-Chan;Kim, Sung-Soo;Shin, Young-Wan;Shin, Hyu-Soung;Kim, Young-Geun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.3
    • /
    • pp.245-256
    • /
    • 2008
  • The steel rib, one of the main support of tunnel, plays a very important role to stabilize tunnel excavation surface until shotcrete or rockbolt starts to perform a supporting function. In general, a steel rib at the horizontal funnel is being installed in the direction of gravity which is known favorable in terms of constructability and stability. However, as the direction of principal stress at the inclined tunnel wall is different from that of gravity, the optimum direction of steel rib could be different from that at the horizontal tunnel. In this study, a numerical method was used to analyze the direction of force that would develope displacement at the inclined tunnel surface, and that direction could be the optimum direction of steel rib. The support efficiency of steel rib could be maximized when the steel rib was installed to resist the displacement of the tunnel. Three directions which were recommended for the inclined tunnels in the Korea Tunnel Design Standard were used for the numerical models of steel rib direction. In conclusion, the results show that all displacement angle of the models are almost perpendicular to the tunnel surface regardless of face angle. So if the steel rib would be installed perpendicular to the inclined tunnel surface, the support efficiency of steel rib could be maximized.

  • PDF

Evaluation of Rib Geometries of Reinforcing Bars Available in Korea, Japan and USA (국내외 이형철근의 마디 형태 및 부착강도 비교)

  • Soe, Dong-Min;Kim, Ki-Seong;Bong, Won-Young;Yang, Seung-Yul;Hong, Gi-Suop;Choi, Oan-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.278-281
    • /
    • 2006
  • The aims of this study are to investigate rib geometries of reinforcing bars commercially available in Korea, Japan and USA, and evaluate bond performance using beam-end test specimens. Measurement of rib geometries of the bars include nominal area, average distance of rib, height of rib and an angle of rib perpendicular to bar axis. The result of this study show that rib height of Korean reinforcement bars are much less than those of Japan and USA resulting in the lowest value of relative rib area. Average bond strength of Korean D25 deformed bars is known as 9 % less than that of bars produced in USA. Bond strength depends primarily on the relative rib area. Bond strength of the high relative rib area bars produced in USA show 18% higher than that of bars produced in Korea.

  • PDF

Numerical study on overall thermal performance in SAH duct with compound roughness of V-shaped ribs and dimples (V 형 rib과 dimple로 구성된 SAH 덕트에서의 총괄 열성능에 대한 수치적 연구)

  • Kumar, Anil;Kim, Man-Hoe
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.43-55
    • /
    • 2015
  • This paper presents the thermal hydraulic performance of a three dimensional rib-roughened solar air heater (SAH) duct with the one principal wall subjected to uniform heat flux. The SAH duct has aspect ratio of 12.0 and the Reynolds number ranges from 2000 to 12000. The roughness has relative rib height of 0.045, ratio of dimple depth to print diameter of 0.5 and rib pitch ratio of 8.0. The flow attack angle is varied from $35^{\circ}$ to $70^{\circ}$. Various turbulent flow models are used for the heat transfer and fluid flow analysis and their results are compared with the experimental results for smooth surfaces. The computational fluid dynamics (CFD) results based on the renormalization k-epsilon model are in better outcomes compared with the experimental data. This model is used to calculate heat transfer and fluid flow in SAH duct with the compound roughness of V-shaped ribs and dimples. The overall thermal performance based on equal pumping power is found to be the highest (2.18) for flow attack angle of $55^{\circ}$. The thermo-hydraulic performance for V-pattern shaped ribs combined with dimple ribs is higher than that for dimple rib shape and V-pattern rib shape air duct.