• 제목/요약/키워드: Reverse recovery

검색결과 339건 처리시간 0.022초

신제품 생산과 회수제품 재가공이 이루어지는 생산시스템에서 최적 처분 정책에 대한 연구 (Optimal Disposal Policy in a Hybrid Production System with Manufacturing and Remanufacturing)

  • 김은갑
    • 대한산업공학회지
    • /
    • 제33권3호
    • /
    • pp.312-321
    • /
    • 2007
  • We address a disposal issue of returned products in a product recovery system where a single product is stocked in order to meet a demand from customers who may return products after usage. Product returns occur randomly and can be accepted for remanufacturing or disposed of depending on the state of the system. We examine the structure of the optimal disposal policy for returned product that utilizes the information of the inventory of both serviceable and remanufacturable products. Numerical study indicates that it can be characterized by a monotonic threshold type of the curve. A disposal is allowed only when the remanufacturable inventory level exceeds a threshold which is the function of the inventory level of serviceable product and it is decreasing as the serviceable inventory level increases. Sensitivity analysis also indicates that the optimal disposal policy and the optimal profit have monotonic properties with respect to system parameters.

이상적이지 않은 직류변환기의 상태공가 모델링(I) (A State-Space Modeling of Non-Ideal DC-DC Converters (I))

  • 임춘택;정규범;조규형
    • 대한전기학회논문지
    • /
    • 제36권10호
    • /
    • pp.713-718
    • /
    • 1987
  • A new method for the modeling of non-ideal dc-dc converters whose switching times are finite is proposed. The effects of finite turn-on, turn-off times, delay time, storage time, reverse recovery process on the system stability, dc transfer function and efficiency are investigated. It is verified how system poles are changed and how dc transfer function and efficiency are decreased by non-ideal switching.

  • PDF

Zero-Voltage-Switching Boost Converter Using a Coupled Inductor

  • Do, Hyun-Lark
    • Journal of Power Electronics
    • /
    • 제11권1호
    • /
    • pp.16-20
    • /
    • 2011
  • This paper presents a zero-voltage-switching (ZVS) boost converter using a coupled inductor. It utilizes an additional winding to the boost inductor and an auxiliary diode. The ZVS characteristic of the proposed converter reduces the switching losses of the active power switches and raises the power conversion efficiency. The principle of operation and a system analysis are presented. The theoretical analysis and performance of the proposed converter were verified with a 100W experimental prototype operating at a 107 kHz switching frequency.

Flow Analysis within a Small Reverse Flow Cyclone

  • R. B Xiang;Lee, K. W.
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 춘계학술대회 논문집
    • /
    • pp.277-278
    • /
    • 2003
  • Cyclone separators are widely used for cleaning gas streams or for catalyst recovery. For many years, the complexity of the gas flow pattern in cyclones has been a matter of many experimental and theoretical work. At present, precise flow measurements have been performed by means of LDA and hot-wire anemometry (Patterson and Munz, 1996; Hoekstra et al., 1999; Peng et al., 2002). In the theoretical work, Computational fluid dynamics (CFD) codes are frequently employed for simulating cyclone gas-particle flows(Hoekstra et al., 1999). (omitted)

  • PDF

Recovery of complete left bundle branch block in dilated cardiomyopathy after optimal heart failure treatment: a case report

  • Geum Ko;Jae-Geun Lee
    • Journal of Medicine and Life Science
    • /
    • 제21권3호
    • /
    • pp.112-116
    • /
    • 2024
  • Complete left bundle branch block (CLBBB) is a significant cardiac conduction abnormality often associated with dilated cardiomyopathy (DCM). This case report highlights the improvement in CLBBB and symptom relief through reverse cardiac remodeling in a patient diagnosed with DCM following an optimized heart failure treatment regimen consisting of an angiotensin-converting enzyme inhibitor, beta-blocker, and mineralocorticoid receptor antagonist. This case highlights the potential of electrical remodeling and conduction system improvement in patients with DCM receiving optimized medical therapy.

세라믹 패키지를 이용한 표면 실장형 다이오드의 제작과 특성 평가 (Manufacture and Characteristic of Surface Mounted Device Type Fast Recovery Diode with Ceramic Package)

  • 전명표;조상혁;조정호;김영익;유인기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.221-221
    • /
    • 2006
  • The SMD type P-N junction diode with ceramic package for diode case were fabricated. It was made this diode with simple process from $Al_2O_3$ ceramic chip, solder preform, diode chip, coating reagent and conductive paste for chip terrmination. Its merit is small size, easy manufacture. fast cooling with ceramic case. The electric characteristics of the diode such as reverse recovery time, breakdown voltage, forward voltage, and leakage current were 5 28ns, 1322V, 1.08V, $0.45{\mu}A$.

  • PDF

HPLC를 이용한 축산식품중 잔류 설폰아미드제의 동시분석법 연구 (A study on simultaneous determination of residual sulfonamides in livestock productions by high performance liquid chromatography)

  • 황래홍;김영수;윤은선;김기근;이규학
    • 한국동물위생학회지
    • /
    • 제18권3호
    • /
    • pp.13-28
    • /
    • 1995
  • This study was carried out to explore the most sensitive and useful method for simultaneous determination of five sulfa drugs(sulfamethazine, sulfamerazine, sulfamonomethoxine, sulfadimethoxine, sulfaquinoxaline) in livestock productions(pork muscle, bovine muscle, chicken muscle, milk ) by HPLC with UV detector and reverse phase column. The results obtained were as follows:1. For mobile phase acetonitrile-0.01M ammonium acetate (23:77) showed more applicable sensitivity and retention times than acetonitrile-1% acetic acid(23:77). Thus acetonitrile-0.01M ammonium acetate(23:77) selected and applied to the modification test, from which it was found pH 6.75 was the most adequate. 2. Optimal wavelength of UV for SMT(sulfamethazine), SMR(sulfamerazine), SMM(sulfamonomethoxine), SD(sulfadimethoxine), and SQ(sulfaquinoxaline) were 266, 266, 265, 269 and 250nm, respectively, and that for simultaneous application it was 263nm. 3. The average recovery rate by extractant(chloroform, dichloromethane, chlorform+dich-loromethane) in the classic method was not significantly different(p>0.05) but that by chloroform higher than the others. Thus chloroform was found to be adequate as extractant in this classic method. 4. The average recovery rate was 86.5% by the MSPD(matrix solid phase disperse) method, which was significantly higher than that by the classic method(p<0.05). Also the recovery rates by method were significantly different(p<0.05) in accordance with sample and type of drug. The MSPD method was much superior to classic method on clean-up.

  • PDF

Smart Honeycomb Sandwich Panels With Damage Detection and Shape Recovery Functions

  • Okabe, Yoji;Minakuchi, Shu;Shiraishi, Nobuo;Murakami, Ken;Takeda, Nobuo
    • Advanced Composite Materials
    • /
    • 제17권1호
    • /
    • pp.41-56
    • /
    • 2008
  • In this research, optical fiber sensors and shape memory alloys (SMA) were incorporated into sandwich panels for development of a smart honeycomb sandwich structure with damage detection and shape recovery functions. First, small-diameter fiber Bragg grating (FBG) sensors were embedded in the adhesive layer between a CFRP face-sheet and an aluminum honeycomb core. From the change in the reflection spectrum of the FBG sensors, the debonding between the face-sheet and the core and the deformation of the face-sheet due to impact loading could be well detected. Then, the authors developed the SMA honeycomb core and bonded CFRP face-sheets to the core. When an impact load was applied to the panel, the cell walls of the core were buckled and the face-sheet was bent. However, after the panel was heated over the reverse transformation finish temperature of the SMA, the core buckling disappeared and the deflection of the face-sheet was relieved. Hence the bending stiffness of the panel could be recovered.

Determination of Thiamine in Pharmaceutical Preparations by Reverse Phase Liquid Chromatography Without Use of Organic Solvent

  • Suh, Joon Hyuk;Kim, Junghyun;Jung, Juhee;Kim, Kyunghyun;Lee, Seul Gi;Cho, Hyun-Deok;Jung, Yura;Han, Sang Beom
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1745-1750
    • /
    • 2013
  • A novel green aqueous mobile phase modified with room temperature ionic liquids (RTILs) was employed in the absence of volatile organic solvents or ion-pairing reagents to analyze thiamine, a very polar compound, by reverse phase high performance liquid chromatography (RP-HPLC). Due to its strongly hydrophilic nature, thiamine was eluted near the column dead time ($t_0$) using a mobile phase without adding RTILs or ion-pairing reagents, even if a 100% aqueous mobile phase, which has weak elution power under reverse phase conditions, was used. Thus, 1-ethyl-3-methyl-imidazolium hexafluorophosphate ([EMIM][$PF_6$]), which has the strongest chaotropic effect, was selected as a mobile phase additive to improve retention and avoid baseline disturbances at $t_0$. Various mobile phase parameters such as cation moiety, chaotropic anion moiety, pH and concentration of RTILs were optimized to determine thiamine at the proper retention time. Method validation was performed to assess linearity, intra- and inter-day accuracy and precision, recovery and repeatability; all results were found to be satisfactory. The developed method was also compared to the current official United States Pharmacopoeia (USP) and Korean Pharmacopoeia (KP) methods using an organic mobile phase containing an ionpairing reagent by means of evaluating various chromatographic parameters such as the capacity factor, theoretical plate number, peak asymmetry and tailing factor. The results indicated that the proposed method exhibited better efficiency of thiamine analysis than the official methods, and it was successfully applied to quantify thiamine in pharmaceutical preparations.

정수기용 역삼투 폐분리막 필터의 세정 및 성능 향상 연구 (Cleaning of the Waste Reverse Osmosis Membrane Filters for the Household Water Purifier and Their Performance Enhancement Study)

  • 조영주;임지원
    • 멤브레인
    • /
    • 제27권3호
    • /
    • pp.232-239
    • /
    • 2017
  • 본 연구에서는 사용 후 폐기되는 정수기용 역삼투(Reverse Osmosis; RO)막 필터를 세정하여 새 필터의 수준으로 복원시키는 연구를 수행하였다. 화학적 세정액으로는 수산화나트륨, 중아황산나트륨, EDTA용액을 사용하였으며 마이크로버블 발생 장치와 함께 in-situ의 방법으로 세정하였다. EDTA를 0.1%의 농도로 제조한 뒤 마이크로버블과 함께 사용하여 30분 세정하였을 때 가장 좋은 결과를 나타내었다. 이때 폐 필터와 세정 후 폐필터의 성능을 비교해 보았을 때 투과도는 19.9%, 회수율은 49.5%증가하였으며 NaCl 100 mg/L 용액에 대한 염제거율은 2.3% 감소되었는데, 이는 새 필터와 동등한 수준으로 회복이 되었다. 또한 전자현미경 분석을 이용하여 막 표면의 오염물의 제거를 육안으로 확인하였다. 이로써 전량 매립 또는 소각 되어지는 정수기용 폐 RO막 필터의 세정을 통하여 재사용이 가능할 것으로 판단된다.