• Title/Summary/Keyword: Reverse Recovery Time

Search Result 70, Processing Time 0.026 seconds

An on-line Deterioration Analysis Method of Inverters using Averaged Switch Modeling (평균 스위치 모델링에 의한 인버터의 온라인 열화진단기법)

  • Park, Chan-Guk;Choi, Young-Gil;Koo, Tae-Geun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1199-1201
    • /
    • 2003
  • This paper presents an averaged switch model for an on-line deterioration analysis of inverters. The model is based on the operational characteristics of power diodes and IGBTS. Switching loss mechanisms are described and divided into the diode reverse-recovery mechanism, the IGBT current-tailing phenomenon, the IGBT turn-on time, and the output capacitances of the IGBTS and diodes. The deterioration analysis parameters are derived from the averaged switch modeling and the parameters can determinate the deterioration of the inverters.

  • PDF

Comparison of Two Experimental Approaches to Test Temporal Storability of Reduced Sulfur Compounds in Whole Sampling Method (환원황화합물에 대한 용기채취법의 비교 연구)

  • Jo, Sang-Hee;Kim, Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.3
    • /
    • pp.306-315
    • /
    • 2012
  • In this study, storage stability of reduced sulfur compounds ($H_2S$, $CH_3SH$, DMS, $CS_2$, and DMDS) and $SO_2$ in sampling bags was investigated in terms of two contrasting storage approaches between forward (F) and reverse (R) direction. The samples for the F method were prepared at the same time and analyzed sequentially through time. In contrast, those of reverse (R) method were prepared sequentially in advance and analyzed all at once upon the preparation of the last sample. In addition, relative performance between two different bag materials (PVF and PEA) was also assessed by using 100 ppb standard. The response factors (RF) of gaseous RSC samples were determined by gas chromatography/pulsed flame photometric detector (GC/PFPD) combined with air server (AS)/thermal desorber (TD) system at storage intervals of 0, 1, and 3 days. There is no statistical difference in all RSCs between two storage methods. However, the results of relative recovery indicated 2.58~12.8% differences in compound type between the two storage methods. Moreover, loss rates and storage stability of $H_2S$ and $SO_2$ were considerably affected by bag materials than any other variables. Therefore, some considerations about storage methods (or bag material types) for sulfur compounds are needed if stored by sampling bag method.

New Modeling of Switching Devices Considering Power Loss in Electromagnetic Transients Program Simulation

  • Kim, Seung-Tak;Park, Jung-Wook;Baek, Seung-Mook
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.592-601
    • /
    • 2016
  • This paper presents the modeling of insulated-gate bipolar transistor (IGBT) in electromagnetic transients program (EMTP) simulation for the reliable calculation of switching and conduction losses. The conventional approach considering the physical property of switching devices requires many attribute parameters and large computation efforts. In contrast, the proposed method uses the curve fitting and interpolation techniques based on typical switching waveforms and a user-defined component with variable resistances to capture the dynamic characteristics of IGBTs. Therefore, the simulation time can be efficiently reduced without losing the accuracy while avoiding the extremely small time step, which is required in simulation by the conventional method. The EMTP based simulation includes turn-on and turn-off transients of IGBT, saturation state, forward voltage of free-wheeling diode, and reverse recovery characteristics, etc. The effectiveness of proposed modeling for the EMTP simulation is verified by the comparison with experimental results obtained from practical implementation in hardware.

Synchronous Bidirectional DC-DC Converter Applying Soft-Switching Technique (소프트 스위칭 기법을 적용한 싱크로너스 양방향 DC-DC 컨버터)

  • Lee, Dong-Gyu;Park, Nam-Ju;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.311-318
    • /
    • 2008
  • This paper proposes synchronous bidirectional DC-DC converter applying soft-switching technique. The proposed converter integrates two advantages which are conduction loss minimization and switching loss elimination by applying interleaved synchronous buck and ZVT-cell with a single resonant inductor. ZVS is guaranteed for wide load range in CCM(Continuous Conduction Mode) as well as wide output voltage range by current injection method. Also, reverse recovery effects of body diode can be minimized. In addition, it is possible to significantly reduce diode drop voltage occurred during dead time of conventional synchronous buck converter. The validity of the proposed converter is verified through experimental results.

Evaluation of Microfiltration Membrane as Prefilter for Reverse Osmosis membrane (역삼투막의 전처리를 위한 정밀여과막의 평가)

  • hong, Seongho;Oh, Seoukhwan;Jeon, Jaehong
    • Clean Technology
    • /
    • v.7 no.3
    • /
    • pp.179-185
    • /
    • 2001
  • Some companies are trying to develop the microfiltration membranes because most of them used as a prefilter is imported in Korea. However, they are faced with much difficulty such as characterization of membrane and controlling of pore size on development. In this study, a microfiltration membrane developed by a company was evaluated for applicability to use as a prefilter before reverse osmosis membrane process in production of ultra pure water. The optimum feed pressure for the raw water was obtained at 0.2 to 0.4 atm. At that time, turbidity of the treated water was 0.4 NTU and flux was 6,000 to $9,000L/m^2/hr$. In case of the conventionally treated water, it showed the very stable flux and turbidity at 90% of recovery rate. The chemical cleaning was helpful to reduce the TMP for treated water. The turbidity was improved from 0.3 NTU to 0.1 NTU after chemical cleaning.

  • PDF

Permeation Property of Each Stage in Three Stage Reverse Osmosis System for Cold-mill Wastewater Reuse (냉연공장 폐수재이용을 위한 3단 역삼투시스템에서 각 단별 투과특성 연구)

  • 박영규
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.209-214
    • /
    • 1999
  • The purpose of this research was to investigate the permeation properties of each stage in three stage reverse osmosis system for cold-mill wastewater reuse. After construction of the three staged pilot plant which had 75% recovery and equipped with seven plate-and-frame modules, the change of each stage's penneate flow and quality were investigated in the process of membrane fouling. The order of average permeate flow was first, second, and third stage at the beginning. As the operation time passed, the permeate flow of first stage was decreased, the second stage was maintained steadily, and the third stage was increased. Accordingly, the fouling was initiated at the first stage and then progressed to the second and third stage. The first stage's permeate quality showed the best and the second and third stage was the next in that order. And the order of quality was maintained during the test periods. Therefore, the permeate quality was not affected by membrane fouling.

  • PDF

Pyrolysis Effect of Nitrous Oxide Depending on Reaction Temperature and Residence Time (반응온도 및 체류시간에 따른 아산화질소 열분해 효과)

  • Park, Juwon;Lee, Taehwa;Park, Dae Geun;Kim, Seung Gon;Yoon, Sung Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.7
    • /
    • pp.1074-1081
    • /
    • 2021
  • Nitrous oxide (N2O) is one of the six major greenhouse gases and is known to produce a greenhouse ef ect by absorbing infrared radiation in the atmosphere. In particular, its global warming potential (GWP) is 310 times higher than that of CO2, making N2O a global concern. Accordingly, strong environmental regulations are being proposed. N2O reduction technology can be classified into concentration recovery, catalytic decomposition, and pyrolysis according to physical methods. This study intends to provide information on temperature conditions and reaction time required to reduce nitrogen oxides with cost. The high-temperature ranges selected for pyrolysis conditions were calculated at intervals of 100 K from 1073 K to 1373 K. Under temperatures of 1073 K and 1173 K, the N2O reduction rate and nitrogen monoxide concentration were observed to be proportional to the residence time, and for 1273 K, the N2O reduction rate decreased due to generation of the reverse reaction as the residence time increased. Particularly for 1373 K, the positive and reverse reactions for all residence times reached chemical equilibrium, resulting in a rather reduced reaction progression to N2O reduction.

Electronic Throttle Body Model Allowing for Non-linearity of DC Motor Driver (DC 모터 드라이버의 비선형성을 고려한 전자식 스로틀 바디 모델)

  • Jin, Sung-Tae;Kang, Jong-Jin;Lee, Woo-Taik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.71-77
    • /
    • 2008
  • This paper proposes an Electronic Throttle Body (ETB) model considering a non-linearity of DC motor driver which is integrated with a H-bridge and a gate driver. A propagation delay and reverse recovery time of switching components cause non-linear characteristic of DC motor driver. This non-linearity affects not only the amateur voltage of DC motor, but also entire behaviour and parameters of ETB. In order to analyze the behavior of ETB more accurately, this non-linear effect of DC motor driver is modeled. The developed ETB model is validated by use of the step response and ramp response experiments, and it shows relatively accurate results compared with linear DC motor driver model.

SiC Based Single Chip Programmable AC to DC Power Converter

  • Pratap, Rajendra;Agarwal, Vineeta;Ravindra, Kumar Singh
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.697-705
    • /
    • 2014
  • A single chip Programmable AC to DC Power Converter, consisting of wide band gap SiC MOSFET and SiC diodes, has been proposed which converts high frequency ac voltage to a conditioned dc output voltage at user defined given power level. The converter has high conversion efficiency because of negligible reverse recovery current in SiC diode and SiC MOSFET. High frequency operation reduces the need of bigger size inductor. Lead inductors are enough to maintain current continuity. A complete electrical analysis, die area estimation and thermal analysis of the converter has been presented. It has been found that settling time and peak overshoot voltage across the device has reduced significantly when SiC devices are used with respect to Si devices. Reduction in peak overshoot also increases the converter efficiency. The total package substrate dimension of the converter circuit is only $5mm{\times}5mm$. Thermal analysis performed in the paper shows that these devices would be very useful for use as miniaturized power converters for load currents of up to 5-7 amp, keeping the package thermal conductivity limitation in mind. The converter is ideal for voltage requirements for sub-5 V level power supplies for high temperatures and space electronics systems.

Optimization and validation of HPLC/DAD method for the determination of adenosine and cordycepin in cordyceps products

  • Sasikarn Panpraneecharoen;Tisorn Chatrakoon;Sompong Sansenya;Saowapa Chumanee
    • Analytical Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.152-160
    • /
    • 2023
  • Adenosine and cordycepin are bioactive compounds with health benefits. Therefore, both substances are often used to assess the quality of Cordyceps products. Optimization and validation of the HPLC/DAD method for determining two nucleosides were studied. The samples were prepared using an ultrasound-assisted extraction (ultrasonic bath). The result was optimal conditions for aqueous extraction, an extraction time of 35 min, and an extraction temperature of 40 ℃. The Chromatographic separation was achieved using a reverse phase column (InfinityLab Poroshell 120 EC-C18, 4.6 × 250 mm, 2.7 ㎛) at 30 ℃ with a mobile phase gradient elution of water and methanol at a flow rate of 0.7 mL/min. The eluents were monitored via a diode array detector at 260 nm. Two nucleosides were separated by less than 12 min after injection. The developed method was found to be excellent linear (r2 > 0.9999), accurate (% recovery 95.34-98.51), and precise (% relative standard deviation < 2.0). The limit of detection (LOD) and quantification (LOQ) were 0.45 and 1.38 mg/mL for adenosine and 0.47 and 1.43 mg/mL for cordycepin, respectively. This method was satisfactory for simultaneously quantitating two nucleoside contents, which were used to evaluate Cordyceps products.