Browse > Article
http://dx.doi.org/10.5572/KOSAE.2012.28.3.306

Comparison of Two Experimental Approaches to Test Temporal Storability of Reduced Sulfur Compounds in Whole Sampling Method  

Jo, Sang-Hee (Department of Environment & Energy, Sejong University)
Kim, Ki-Hyun (Department of Environment & Energy, Sejong University)
Publication Information
Journal of Korean Society for Atmospheric Environment / v.28, no.3, 2012 , pp. 306-315 More about this Journal
Abstract
In this study, storage stability of reduced sulfur compounds ($H_2S$, $CH_3SH$, DMS, $CS_2$, and DMDS) and $SO_2$ in sampling bags was investigated in terms of two contrasting storage approaches between forward (F) and reverse (R) direction. The samples for the F method were prepared at the same time and analyzed sequentially through time. In contrast, those of reverse (R) method were prepared sequentially in advance and analyzed all at once upon the preparation of the last sample. In addition, relative performance between two different bag materials (PVF and PEA) was also assessed by using 100 ppb standard. The response factors (RF) of gaseous RSC samples were determined by gas chromatography/pulsed flame photometric detector (GC/PFPD) combined with air server (AS)/thermal desorber (TD) system at storage intervals of 0, 1, and 3 days. There is no statistical difference in all RSCs between two storage methods. However, the results of relative recovery indicated 2.58~12.8% differences in compound type between the two storage methods. Moreover, loss rates and storage stability of $H_2S$ and $SO_2$ were considerably affected by bag materials than any other variables. Therefore, some considerations about storage methods (or bag material types) for sulfur compounds are needed if stored by sampling bag method.
Keywords
Reduced Sulfur Compounds (RSC); Storage stability; Storage method; Polyvinyl fluoride bag; Polyester aluminum bag;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Nagata, Y. (2003) Measurement of odor threshold by triangle odor bag method, Odor Measurement Review, Ministry of Environment (MOE), Japan, pp. 118-127.
2 Ochiai, N., M. Takino, S. Daishima, and D.B. Cardin (2001) Analysis of volatile sulphur compounds in breath by gas chromatography-mass spectrometry using a three-stage cryogenic trapping preconcentration system, J. of Chromatography B, 762, 67-75.   DOI   ScienceOn
3 Park, K.-H., H.-E. Kim, H.-S. Jo, K.-S. Lee, and K.-P. Song (2005) Analysis of odorous compounds (sulfur and hydro carbon compounds) and public discontent of odor in Ansan city, Proceeding of the 40th Meeting of KOSAE, 143-145.
4 Sulyok, M.S., C. Haberhauer-Troyer, and E. Rosenberg (2002) Observation of sorptive losses of volatile sulfur compounds during natural gas sampling, J. of Chromatography A, 946, 301-305.   DOI   ScienceOn
5 Trabue, S., K. Scoggin, F. Mitloehner, H. Li, R. Burns, and H. Xin (2008) Field sampling method for quantifying volatile sulfur compounds from animal feeding operations, Atmospheric Environment, 42, 3332-3341.   DOI   ScienceOn
6 Jo, H.-J. and K.-H. Kim (2011) Storage stability of reduced sulfur gases in Tedlar bag sampler: Test of two different storing approaches, Analytical Science & Technology, 24(3), 212-218. (in Korean with English abstract)   DOI   ScienceOn
7 Jo, S.-H., K.-H. Kim, M. Rahman, and H.-O. Yoon (2011) Emission characteristics of reduced sulfur compounds and gaseous elemental mercury from landfill gas, Korean Journal of Odor Research and Engineering, 10(3), 126-135. (in Korean with English abstract)
8 Kim, J.-B., S.-J. Jeong, and I.-S. Song (2007) The concentrations of sulfur compounds and sensation of odor in the residential area around Banwol-Sihwa industrial complex, J. of Korean Society for Atmospheric Environment, 23(2), 147-157. (in Korean with English abstract)   DOI   ScienceOn
9 Kim, K.-H. (2008) A method to test the detectability of GC/PFPD for an extended concentration range with respect to reduced sulfur compounds, J. Sep. Sci., 31, 1761-1768.   DOI   ScienceOn
10 Kim, K.-H. and S.-H. Jo (2011) A preliminary study on polyester aluminum bag as the possible substitute for Tedlar bag sampler in RSC analysis, J. of Korean Society for Atmospheric Environment, 27(4), 454-459. (in Korean with English abstract)   DOI   ScienceOn
11 Kim, K.-H., Y.-J. Choi, and J.-W. Ahn (2005) Reduced sulfur gas loss in the bag sampling procedure - Comparison by calibration slope values, Analytical Science & Technology, 18(4), 338-343. (in Korean with English abstract)
12 Hayashida, A., K. Hoshi, Y. Sato, J. Ito, T. Arai, S. Imai, N. Hanada, and H. Uematsu (2005) Comparison of sampling bags used for measuring breath odor, Oral Diseases, 98-121.
13 An, S.-Y., O.-S. Kim, Y.-J. Lee, M.-G. Kim, C.-G. Na, C.-W. Lee, and J.-H. Park (2007) A survey on the malodor emission characteristics for malodor complaint in Gyeongbuk area from 2005 to 2006, Korean Journal of Odor Research and Engineering, 6(2), 81-86. (in Korean with English abstract)