• Title/Summary/Keyword: Reverse Osmosis (RO)

Search Result 232, Processing Time 0.029 seconds

Evaulation of Developing New-Fusion Eco-Friendly Biocide on the Reverse Osmosis Membranes (살균에 박리 및 분산 기능이 추가된 친환경살균제에 대한 역삼투(RO)막에서의 효과 검증 연구)

  • Park, Duk Joon;Oh, Eun Jung;Kim, Sung Han;Ahn, Kwang Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.497-503
    • /
    • 2016
  • Eco-friendly biocide that do not have noxious chemicals, have a role of disinfection adding of dispersion and strengthening peer power on RO membranes surfaces. Eco-friendly biocide show an 93% improvement of differential pressures arrival time. Also, eco-friendly biocide's Autopsy result show less the percentage of organic pollutants than currently in using biocide. Adding dispersion & peeling strength power to remove the microorganisms is upgrading. Eco-friendly biocide that have a dispersion and peering power is non-toxicant chemicals and is safe for user.

Effects of hypochlorite exposure on morphology and trace organic contaminant rejection by NF/RO membranes

  • Simon, Alexander;Nghiem, Long D.
    • Membrane and Water Treatment
    • /
    • v.5 no.4
    • /
    • pp.235-250
    • /
    • 2014
  • The impacts of membrane degradation due to chlorine attack on the rejection of inorganic salts and trace organic contaminants by nanofiltration (NF) and reverse osmosis (RO) membranes were investigated in this study. The rejection of trace contaminants was examined at environmentally relevant concentrations. Changes in the membrane surface morphology were observed as a result of chlorine exposure. A small increase in rejection was consistently observed with all four membranes selected in this study after being exposed to a low concentration of hypochlorite (100 ppm). In contrast, a higher concentration of hypochlorite (i.e., 2000 ppm) could be detrimental to the membrane separation capacity. Membranes with severe chlorine impact showed a considerable decrease in rejection over filtration time, possibly due to rearrangement of the polyamide chains under the influence of chlorine degradation and filtration pressure. The reported results indicate that loose NF membranes are more sensitive to chlorine exposure than RO membranes. The impact of hypochlorite exposure (both positive and negative) on rejection is dependent on the strength of the hypochlorite solution and is more significant for the neutral carbamazepine compound than the negatively charged sulfamethoxazole.

Comparisons of Reverse Osmosis and Pervaporation Membrane Processes. I. Theoretical Interpretations. (역삼투와 투과 증발막 공정의 비교. I. 이론적 해석)

  • Rhim, Ji-Won;Lee, Kew-Ho;Bae, Seong-Youl;H
    • Membrane Journal
    • /
    • v.3 no.1
    • /
    • pp.29-34
    • /
    • 1993
  • Reverse osmosis(RO) and pervaporation(PV) membrane processes were compared with each other theoretically by using Paul and Ebra-Lima model. From this model the concentrations of liquid within the membrane when pressure was applied to the upper compartment(for PV case, the applied pressure is infinite) were calculated for rubber membrane-n-hexane and rubber membrane-benzene systems. The permeabilities of RO and PV were also calculated and compared for polyethylene film-n- hexane and polyethylene film- benzene systems Theoretically, the permeabilities of PV membrane were greater than those of RO membrane.

  • PDF

Performance evaluation of forward osmosis (FO) hollow fiber module with various operating conditions (중공사막 모듈을 이용한 정삼투 공정에서의 운영조건 변화에 따른 성능평가)

  • Kim, Bongchul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.4
    • /
    • pp.357-361
    • /
    • 2018
  • Forward osmosis (FO) process has been attracting attention for its potential applications such as industrial wastewater treatment, wastewater reclamation and seawater desalination. Particularly, in terms of fouling reversibility and operating energy consumption, the FO process is assumed to be preferable to the reverse osmosis (RO) process. Despite these advantages, there is a difficulty in the empirical step due to the lack of separation and recovery techniques of the draw solution. Therefore, rather than using FO alone, recent developments of the FO process have adapted a hybrid system without draw solution separation/recovery systems, such as the FO-RO osmotic dilution system. In this study, we investigated the performance of the hollow fiber FO module according to various operating conditions. The change of permeate flow rate according to the flow rates of the draw and feed solutions in the process operation is a factor that increases the permeate flow rate, one of the performance factors in the positive osmosis process. Our results reveal that flow rates of draw and feed solutions affect the membrane performance, such as the water flux and the reverse solute flux. Moreover, use of hydraulic pressure on the feed side was shown to yield slightly higher flux than the case without applied pressure. Thus, optimizing the operating conditions is important in the hollow fiber FO system.

Effect of Silica and Iron on the Fouling Tendency of Reverse Osmosis Membrane for Treating Wastewater from an Integrated Iron and Steel Mill (역삼투막을 이용한 제철폐수 처리 시 실리카 및 철 이온이 막 폐색에 미치는 영향)

  • Oh, Hee-Wan;Lee, Chae-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.547-553
    • /
    • 2018
  • An integrated iron and steel mill uses a large amount of water and produces wastewater which contains various contaminants such as iron, manganese, etc. Especially, in some regions of Southeast Asia, the concentration of silica in iron and steel mill wastewater is higher than in other countries. Silica is known to be one of the main causes for fouling in the membrane processes for water reuse. In cases of high concentrations of silica in iron and steel mill wastewater, the ferrous silicate tends to be formed. This could lead to higher fouling tendency depositing on the membrane surface. Therefore we conducted a pilot test to investigate the effect of silica and iron on the fouling tendency of reverse osmosis (RO) membrane for treating two types of wastewater from an integrated iron and steel mill. In this case of treated wastewater from iron and steel mill, RO pilot plant was operated with the fluxes 15.9LMH and 18.8LMH for 112 days to investigate the fouling characteristics. The results found that the fluctuation of flux was much wider than the average flux and the minimum permeability was low at 78%. In the case of treated runoff from an integrated iron and steel mill, the average concentration of iron was lower than in wastewater. RO pilot test was conducted with the flux 18.8LMH for 46 days. The results found that runoff had a lower fouling tendency and pre-treatment using microfiltration (MF) could minimize the fouling problem of RO.

The Characteristics of Seawater RO Membrane for High Recovery System (해수담수화용 역삼투막의 고회수율 공정에서의 투과 특성)

  • 김노원
    • Membrane Journal
    • /
    • v.12 no.3
    • /
    • pp.182-191
    • /
    • 2002
  • Polyamide reverse osmosis (RO) membrane with thin film composite structure was commercialized for seawater desalination process. Recently, it has been reported that some RO processes for high pressure and recovery leads to reducing in energy cost and pretreatment scale compared with earlier process. The development of energy recovery, pumping device and RO elements with high pressure and rejection made high pressure and recovery process possible. In this study, permeation properties of commercialized seawater RO membrane were investigated under the condition of high pressure and recovery. In the RO sheet membrane test 3.5% NaCl of synthetic seawater was used. The synthetic seawater contained only sodium chloride. In the RO module test, natural seawater was used at Happo Bay, Masan city. As the results, RO membrane with high durability of pressure was better than that with high rejection of seawater for high pressure and recovery process. Seawater rejection of high concentrate tends to be improved by high pressure operation.

Considerations to design high-pressure membrane system to produce high quality potable water with lower organic matter concentration (유기물 농도가 낮은 고품질 정수 생산을 위한 고압막여과 공정 설계 시 고려사항)

  • Jeon, Jongmin;Kim, Seong-Su;Seo, Inseok;Kim, Suhan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.473-480
    • /
    • 2020
  • High-pressure membrane system like nanofiltration(NF) and reverse osmosis(RO) was investigated as a part of water treatment processes to produce high quality potable water with low organic matter concentration through membrane module tests and design simulation. River water and sand filtration permeate in Busan D water treatment plant were selected as feed water, and NE4040-90 and RE4040-Fen(Toray Chemical Korea) were used as NF and RO membranes, respectively. Total organic carbon(TOC) concentrations of NF and RO permeates were mostly below 0.5 mg/l and the average TOC removal rates of NF and RO membranes were 93.99% and 94.28%, respectively, which means NF used in this study is competitive with RO in terms of organic matter removal ability. Different from ions rejection tendency, the TOC removal rate increases at higher recovery rates, which is because the portion of higher molecular weight materials in the concentrated raw water with increasing recovery rate increases. Discharge of NF/RO concentrates to rivers may not be acceptable because the increased TDS concentration of the concentrates can harm the river eco-system. Thus, the idea of using NF/RO concentrate as the raw water for industrial water production was introduced. The design simulation results with feed water and membranes used in this work reveal that the raw water guideline can be satisfied if the recovery rate of NF/RO system is designed below 80%.

Development of SWRO-PRO hybrid process simulation and cost estimation program (역삼투-압력지연삼투 조합공정 공정모사 및 비용예측 프로그램 개발)

  • Choi, Yongjun;Shin, Yonghyun;Lee, Sangho;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.299-312
    • /
    • 2016
  • The main objective of this paper is to develop computer simulation program for performance evaluation and cost estimation of a reverse osmosis (RO) and pressure-retarded osmosis (PRO) hybrid process to propose guidelines for its economic competitiveness use in the field. A solution-diffusion model modified with film theory and a simple cost model was applied to the simulation program. Using the simulation program, the effects of various factors, including the Operating conditions, membrane properties, and cost parameters on the RO and RO-PRO hybrid process performance and cost were examined. The simulation results showed that the RO-PRO hybrid process can be economically competitive with the RO process when electricity cost is more than 0.2 $/kWh, the PRO membrane cost is same as RO membrane cost, the power density is more than $8W/m^2$ and PRO recovery is same as 1/(1-RO recovery).

Investigation of Organic Fouling with AFM(Atomic Force Microscope) in Reverse Osmosis Membrane and Forward Osmosis Membrane (FO와 RO막에서 AFM(Atomic Force Microscope)을 이용한 유기 막 오염 연구)

  • Kuk, Ji-Hoon;Lee, Sang-Youp;Hong, Seung-Kwan
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.102.1-102.1
    • /
    • 2010
  • 대체수자원 중 막여과 기술에 대한 관심이 지속적으로 높아지고 있다. 하지만, 이러한 막여과 기술에는 fouling이 발생시 효율저감, flux저감, 소모에너지 증대 등 문제점이 발생한다. 이러한 fouling저감을 위해 막 표면특성분석을 통한 기초연구가 필요하다고 보고 이 연구를 진행하였다. AFM을 이용하여 CML입자와 막의 상호작용을 통해 초기 막오염 경향을 예측할 수 있다.

  • PDF

The Hardness Water Production By RO/NF/ED Linking Process From Deep Seawater (RO/NF/ED 연계 공정에 의한 고경도 담수 제조)

  • Moon, Deok-Soo;Kim, Kwang Soo;Gi, Ho;Choi, Mi Yeon;Jung, Hyun Ji;Kim, Hyun Ju
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.4
    • /
    • pp.227-238
    • /
    • 2013
  • The purpose of this study is to develop a process technology to produce high hardness drinking water which meet drinking water standard, remaining useful minerals like magnesium and calcium in the seawater desalination process while removing the sulfate ions and chloride ions. Seawater have been separated the concentrated seawater and desalted seawater by passing on Reverse Osmosis membrane (RO). Using Nano-filtration membrane (NF), We were prepared primary mineral concentrated water that sodium chloride were not removed. By the operation of electro-dialysis (ED) having ion exchange membrane, we were prepared concentrated mineral water (Mineral enriched desalted water) which the sodium chloride is removed. We have produced the high hardness water to meet the drinking water quality standards by diluting the mineral enriched desalted water with deionized water by RO. Reverse osmosis membranes (RO) can separate dissolved material and freshwater from seawater (deep seawater). The desalination water throughout the second reverse osmosis membrane was completely removed dissolved substances, which dissolved components was removed more than 99.9%, its the hardness concentration was 1 mg/L or less and its chloride concentration was 2.3 mg/L. Since the nano-filtration membrane pore size is $10^{-9}$ m, 50% of magnesium ions and calcium ions can not pass through the nano-filtration membrane, while more than 95% of sodium ions and chloride ions can pass through NF membrane. Nano-filtration membrane could be separated salt components like sodium ion and chloride ions and hardness ingredients like magnesium ions and calcium ions, but their separation was not perfect. Electric dialysis membrane system can be separated single charged ions (like sodium and chloride ions) and double charged ions (like magnesium and calcium ions) depending on its electrical conductivity. Above electrical conductivity 20mS/cm, hardness components (like magnesium and calcium ions) did not removed, on the other hand salt ingredients like sodium and chloride ions was removed continuously. Thus, we were able to concentrate hardness components (like magnesium and calcium ions) using nano-filtration membrane, also could be separated salts ingredients from the hardness concentration water using electrical dialysis membrane system. Finally, we were able to produce a highly concentrated mineral water removed chloride ions, which hardness concentration was 12,600 mg/L and chloride concentration was 2,446 mg/L. By diluting 10 times these high mineral water with secondary RO (Reverse Osmosis) desalination water, we could produce high mineral water suitable for drinking water standards, which chloride concentration was 244 mg/L at the same time hardness concentration 1,260 mg/L. Using the linked process with reverse osmosis (RO)/nano filteration (NF)/electric dialysis (ED), it could be concentrated hardness components like magnesium ions and calcium ions while at the same time removing salt ingredients like chloride ions and sodium ion without heating seawater. Thus, using only membrane as RO, NF and ED without heating seawater, it was possible to produce drinking water containing high hardness suitable for drinking water standard while reducing the energy required to evaporation.