• Title/Summary/Keyword: Reverse Channel

Search Result 229, Processing Time 0.032 seconds

Improvement of Channel Estimation Algorithm in Mobile/Satellite Communication Systems

  • Kim, Byung-Gi;Ryoo, Sang-Jin;Lee, Chang-Hun;Choi, Kwang-Seok;Kim, Seong-Hwan;Kang, Seong-Jun;Na, Cheol-Hun
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.3
    • /
    • pp.404-411
    • /
    • 2009
  • In this paper, in order to increase system capacity and reduce the transmitting power of the user's equipment, we propose an efficient power estimation consisting of a modified open-loop power control (OLPC) and closed-loop power control (CLPC) schemes for mobile/satellite communications systems. The OLPC works well if the forward and reverse links are perfectly correlated and the CLPC is sensitive to round-trip delay (RTD). Therefore, it is not effective in mobile/satellite system. In order to solve the above problem, we added monitoring equipment to both the OLPC and CLPC to use information about transmitting power that has not yet been received by the receiver over the satellite/ATC channel. Moreover, we adapted an efficient pilot diversity of both OLPC and CLPC in order to get a better signal to interference plus noise ratio (SIR) estimation of the received signal.

Multi-symbol detection for biorthogonal signals over rayleigh fading channels (레일리 페이딩 채널에서의 이중직교 신호에 대한 다중심볼 검파)

  • 엄의식;윤순영;이황수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.1
    • /
    • pp.30-39
    • /
    • 1997
  • In this paper, a new practical coherent detection scheme for biorthogonal signals, which uses multi-symbol observation interval, is proposed and its performances are analyzed and simulated. The technique jointly estimates both the demondulated data and the channel from received signal only while reducing computation complexity by an approximate maximum-likelihood sequence estimation rather than symbol-by-symbol detection as in previous noncoherent detection. The scheme achieves performance close to that of ideal coherent detection with perfect channel estimates when select the appropriate observation symbol interval N in the given symbol alphabet wize M. What is particularly interesting is that the requeired average signal-to-noise ratio per bit ${\gamma}_{b}$ can be reducedd by as much as 1.4dB and the capacity can be increase by as much as 38% when we use this system in the CDMA cellular reverse link.

  • PDF

A Forward Link ADA Positioning method for mobile Robots (이동 로봇을 위한 순방향 링크 AOA 측위 방법)

  • Kim, Dong-Hyouk;Song, Seung-Hun;Roh, Gi-Hong;Sung, Tae-Kyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.6
    • /
    • pp.603-608
    • /
    • 2007
  • In the conventional AOA(angle-of-arrival) positioning utilizing reverse-link wireless channel, each sensor should be equipped with an array antenna to measure the incident angle of signal transmitting from a tag. To perform the complicated signal processing for angle measurements, sensor size and its power consumption will be large. In some applications like mobile robot location, there exists no strict restriction in tag size or in power consumption. Rather, it is desirable that the sensor would be as small as possible. This paper presents a new AOA positioning method utilizing forward-link channel. Under the assumption that the mobile robot is operating on the flat surface, the measurement model for FLAOA(tiJrward-link AOA) is derived first. Two kinds of position estimation algorithms using FLAOA measurements are proposed; Gauss-Newton method and closed-fonn solution method. With the proposed methods, we can ohtain the attitude of robot as well as its position. Positioning performance of proposed methods is compared by computer simulation. Simulation results show that the closed-form solution method using FLAOA measurements is suitable for indoor robot positioning.

A Study on the performance of coded Multi-carrier Code Division Multiple Access communication system in Rician Fading channel (Rician 페이딩채널상의 부호화 MC-CDMA시스템 성능에 관한 연구)

  • 고연화;이정재;최삼길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.3
    • /
    • pp.309-315
    • /
    • 1998
  • This paper is analyzed the performance of coded MC-CDMA system using the multi-carrier with narrow band that is suggested to solve ISI and ICI of DS-CDMA system. In this paper, considered channel model is indoor mobile radio communication environment with Rician fading distribution and fading of multi-carrier have mutual independent characteristics. For the performance analysis of MC-CDMA system, first, bit error probability of uncoded system is simulated in the reverse and forward Rician channels. And then, it is simulated that bit error probability of coded MC-CDMA system for users, multicarriers and SNR, using (7,4) Hamming code, (15,7) BCH code and 1/2-convolutional code with 7 constraint length.

  • PDF

Performance analysis of a MC-CDMA cellular system with antenna arrays in a fading channel (페이딩 채널 환경에서 안테나 어래이를 갖는 MC-CDMA 셀룰라 시스템의 성능 분석)

  • 김찬규;조용수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.12
    • /
    • pp.2686-2695
    • /
    • 1997
  • The MC-CDMA(multi-carrier code division multiple access) technique is known to be appropriate for high data-rate wireless communications such as mobile multimedia communication due to its robustness to multipath fading and its capability of handing high data rates with a simple one-tap equalizer. In this paepr, the performance of a MC-CDMA cellular system employing antenna arrays at the based station in a fading channel is presented. It is whown that the interference from other users within the cell can be significantly reduced for both reverse link (mobile to base station) and forward link (base station to mobile) using a MC-CDMA with antenna arrays, thus incresig the system's user-capacity. Computer simulations that demonstrate user-capacity improvement of the proposed approach are discussed.

  • PDF

Development of an automatic measurement system for the AC-DC current transfer difference of the thermal current converter (열전형 전류 변환기의 교류-직류 전류 변환차이 자동측정시스템 개발)

  • Kwon, Sung-Won;Jung, Jae-Kap;Kim, Mun-Seog;Kim, Kye-Tae;Ryu, Je-Cheon
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.350-356
    • /
    • 2005
  • We have developed a dual-channel type automatic measurement system to evaluate AC-DC current transfer difference of the thermal current converter(TCC) which is primary standard of AC current. The output drift effect of the TCC is minimized by measuring simultaneously the output voltages of two TCCs using voltmeter. Furthermore, the offset voltage of the voltmeter is cancelled nearly out by taking the average values of two outputs of TCCs measured with the forward-reverse directions using dual channel scanner. The uncertainties of the automatic system were 7 to $86{\mu}A/A$ for 3 mA to 10 A at 40 Hz to 20 kHz, which were evaluated by the comparisons between adjacent range of TCCs and inter-comparison with national measurement institute of Germany(PTB). The capability for ac-dc transfer difference measurement was improved by one order compared with that for the manual ac-dc measurement system.

The Effect of ATP-sensitive Potassium Channel on R-PIA Induced Mechanical Antiallodynia in a Peripheral Neuropathic Rat (신경병증 통증 모델의 백서에서 R-PIA의 기계적 항이질통 효과와 ATP-감수성 칼륨 통로와의 연관성에 대한 연구)

  • Min, Hong Gi;Seong, Seung Hye;Jung, Sung Mun;Shin, Jin Woo;Gwak, Mi Jung;Leem, Jeong Gill;Lee, Cheong
    • The Korean Journal of Pain
    • /
    • v.18 no.2
    • /
    • pp.107-112
    • /
    • 2005
  • Background: Nerve ligation injury may produce mechanical allodynia, but this can be reversed after an intrathecal administration of adenosine analogues. In many animal and human studies, ATP-sensitive potassium channel blockers have been known to reverse the antinociceptive effect of various drugs. This study was performed to evaluate the mechanical antiallodynic effects of spinal R-PIA (Adenosine A1 receptor agonist) and the reversal of these effects due to pretreatment with glibenclamide (ATP-sensitive potassium channel blocker). Thus, the relationship between the antiallodynic effects of R-PIA and ATP-sensitive potassium channel were investigated in a neuropathic model. Methods: Male Sprague Dawley rats were prepared by tightly ligating the left lumbar 5th and 6th spinal nerves and implantation of a chronic lumbar intrathecal catheter for drug administration. The mechanical allodynia was measured by applying von Frey filaments ipsilateral to the lesioned hind paw. And the thresholds for paw withdrawal assessed. In study 1, either R-PIA (0.5, 1 and $2{\mu}g$) or saline were administered intrathecally for the examination of the antiallodynic effect of R-PIA. In study 2, glibenclamide (2, 5, 10 and 20 nM) was administered intrathecally 5 min prior to an R-PIA injection for investigation of the reversal of the antiallodynic effects of R-PIA. Results: The antiallodynic effect of R-PIA was produced in a dose dependent manner. In study 1, the paw withdrawal threshold was significantly increased with $2{\mu}g$ R-PIA (P < 0.05). In study 2, the paw withdrawal threshold with $2{\mu}g$ R-PIA was significantly decreased almost dose dependently by intrathecal pretreatment of 5, 10 and 20 nM glibenclamide (P < 0.05). Conclusions: These results demonstrated that an intrathecal injection of ATP-sensitive potassium channel blockers prior to an intrathecal injection of adenosine A1 receptors agonist had an antagonistic effect on R-PIA induced antiallodynia. The results suggest that the mechanism of mechanical antiallodynia, as induced by an intrathecal injection of R-PIA, may involve the ATP-sensitive potassium channel at both the spinal and supraspinal level in a rat nerve ligation injury model.

Dynamic Channel Allocation Algorithm for TD-SCDMA Smart Antenna System with Inter-cell Interference (인접 셀 간섭영향을 고려한 TD-SCDMA 스마트 안테나 시스템의 동적 채널 할당 알고리즘)

  • Jang, Min-Seok;Hong, Een-Kee
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.4
    • /
    • pp.415-422
    • /
    • 2007
  • In this paper, we proposed a new dynamic channel allocation algorithm for TD-SCDMA with cross time slots. In order to reduce the interference in cross time slot, the mobile stations (MSs) are divided into two groups: the Near Group consisting of MSs near by the base station(BS) and the Far Group including the MSs far from the BS. The reverse link for MSs in the Near Group and forward link for MSs in the Far Group are allocated to the cross time slot. In cellular systems, a BS has multiple neighbor BSs. Some of neighbor BSs can operate in the same direction link while the others have cross time slot. Thus, it is required to determine which BS has the most significant impact in terms of interference. We divide each cell into 6 areas based on the direction of arrival of smart antenna and the most significant neighbor sector is determined with this division. The proposed allocation method and area division method can avoid the severe interference in cross time slots and increase the system capacity about 2%~9% compared to FCA, and 0.5%~1.3% compared to RCA.

  • PDF

Performance Evaluation of Channel Estimation Algorithm for Pilot Symbol-Assisted IMT-2000 System over Multipath Rayleigh Fading Channel (다중경로 레일레이 페이딩 채널에서 파일럿 심볼 구조의 IMT-2000 시스템의 채널추정 알고리즘 성능평가)

  • 구제길;최형진
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.7
    • /
    • pp.1128-1138
    • /
    • 2000
  • This paper presents two different approaches for channel estimation of IMT-2000 pilot symbol-assisted W-CDMA reverse link over Rayleigh fading channels of one and two paths. By obtaining BER performance through computer simulations, the proposed algorithms of 2-point second-order interpolation and IDD BWMA are compared with the performance of existing interpolation and adaptive algorithms. The BER performance of the proposed algorithms is superior to WMSA, linear and second-order Gaussian interpolation, LMS, and RLS algorithm in fast fading channels. In particular, the BER performance of the IDD BWMA algorithm is nearly insensitive for Doppler frequency within simulation range $E_b/N_0$ = 28 dB. The two proposed algorithms also have relatively simple structure and similar processing delay in comparison to the existing algorithms. Therefore, these algorithms are more suitable for high-speed mobile communication environments.

  • PDF

Characterization of PCR fragment of metallothionein gene from liver mRNS of channel catfish (챠넬메기의 간 mRNA 로부터 분리한 metallothionein 유전자의 PCR 절편의 특성)

  • Song, Young-Hwan
    • Journal of fish pathology
    • /
    • v.10 no.1
    • /
    • pp.39-44
    • /
    • 1997
  • Metallothionein is an important and essential protein to control the intracellular concentration of heavy metals, which exist in all organisms from bacteria to vertebrates. Although the detailed functions and induction mechanisms of metallothionein gene have not been clearly characterized until yet, the structure of several metallothionein genes has been revealed. Especially, piscine metallothionein is regarded as an important protein because it is induced by several heavy metal pollutants and environmental stress and it could be determined the comparative amount of heavy metals and the extent of environmental stress by assaying the RNA transcript of metallothionein gene in the method of the quantitative RT-PCR(Reverse Transcriptase Polymerase Chain Reaction). In this study I have characterized the 450 bp PCR fragment of metallothionein gene amplified by using the mixture of internal specific primers and universal 3' end primer. The nucleotide sequence analysis of 450 bp PCR fragment amplified in cDNA library of channel catfish did not show strong homology to other piscine metallothionein genes.

  • PDF