• Title/Summary/Keyword: Reverberation level

Search Result 88, Processing Time 0.023 seconds

Measurement method for valve noise (밸브의 소음 측정 방법)

  • Lee, Y. B.;Yoon, B. R.;Kwon, H. S.;Park, K. A.;Yoo, S. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.433-438
    • /
    • 2001
  • Noise is one of the major environmental problems in human life. To reduce the noise emitted from the control valve it is necessary to develop the measurement method, measurement system, analysis method applicable to the field. In this study IEC and ISO standards were investigated and measurement method for the valve noise was proposed. Noise from the valve was measured in the reverberation room and sound power level was calculated. The sound power level increased as the flow rate and pressure difference increased. The noise characteristics are useful to predict valve noise for given conditions, to compare the performance of different valves and to develope low-noise valves.

  • PDF

Interior Noise Reduction for Subway Railroad Vehicles (통근형 지하철의 실내소음저감)

  • 김종년;유동호;박경환
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.265-272
    • /
    • 1998
  • In this paper, the intoner noise reduction for subway railroad vehicles was studied by improving transmission loss of carbody panels and side doors, and on-line tests were conducted to examine the exterior noise levels at various running conditions. Also the transmission loss for design candidates of the carbody specimen was measured in two reverberation rooms. From the results of the tests, side door gap is the most dominant factor affecting the Interior noise level of subway railroad cars with a sliding typed side door. The next one is revealed to transmission loss of a floor panel. To improve the transmission loss of the carbody, many activities were conducted such as, treatment of resilient and sound-absorbing materials and reducing the gap of the side door by adopting a brush and rubber, etc. The estimated interior noise level for modified car which is designed with improved carbody panels is lower than original car by about 5㏈.

  • PDF

Effects of the sound field characteristics of the receiving room on heavy-weight impact sound measurement generated by impact ball (임팩트 볼에 의한 중량충격음 측정에 있어서 수음실 음장특성의 영향)

  • Yoo, Seung-Yup;Lee, Sin-Young;Jeong, Young;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.622-625
    • /
    • 2006
  • This study is a fundamental investigation for standardization of the heavy-weight floor impact measuring method by the impact ball. The distribution chrematistics of floor impact sound level and reverberation time in a receiving room of the testing building for floor impact sound were measured with variations of number and arrangement of the sound-absorbing materials. Total 8 cases were investigated. The distribution of the floor impact sound level($L_{i,\;Fmax}$) was measured at 30 points with same intervals. The absorption coefficient of the room is 0.10 in case of installation of 6 absorbing materials and 0.02 in case of non-installation. The distribution shape of the impact sound pressure level was similar to the result of the bang machine driving at the measured frequency range. However, the overall reduction of the impact sound level investigated in the 125 to 500 Hz shows that the sound absorption characteristics of the receiving room actually affects the result of the heavy-weight impact measurement.

  • PDF

Effects of the Facade of the Buildings on the Sound Characteristics in an Apartment Complex (공동주택 입면 변화에 따른 단지 내 소음특성)

  • Kim, Yong-Hee;Lee, Pyoung-Jik;Jeon, Jin-Yong;Lee, Byung-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.367-370
    • /
    • 2005
  • This paper investigated the sound characteristics in an apartment complex. The field measurement was conducted in order to examine the acoustical characteristics of the apartment complex in situ. As a result, it shows that there are around 3 sec. reverberation time and the additional sound reinforcements at the area of high height due to the surrounded buildings. Thus, 1:50 Scale model measurement and Raynoise computer simulation were carried out with insertion of the parapet and the canopy on the balcony. In case of a single building, the parapet was effective to reduce noise level at low floor levels, and the canopy was effective to reduce noise level at high floor levels. But it also shows that both the parapet and the canopy were not effective to reduce noise level at middle floor levels. In case of an apartment complex, the canopy was less effective to reduce noise level at each floor in comparison with case of the single building.

  • PDF

Effect of noise and reverberation on subjective measure of speech transmission performance for elderly person with hearing loss in residential space (주거 공간에서 고령자 청력손실을 고려한 소음 및 잔향에 따른 음성 전송 성능의 주관적 평가)

  • Oh, Yang Ki;Ryu, Jong-Kwan;Song, Han-Sol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.369-377
    • /
    • 2018
  • This study investigated the effect of noise and reverberation on subjective measure of speech transmission performance for elderly person with hearing loss in residential space through listening test. Floor impact, road traffic, airborne, and drainage noise were employed as the residential noise, and several impulse responses were obtained through room acoustical computer simulation for an apartment building. Sound sources for the listening test consisted of residential noises and speech sounds for boh the young (the original sound) and the aged (the sound filtered out by filters with frequency responses of hearing loss of 65 years elderly person). In the listening test, subjects evaluated speech intelligibility and listening difficulty for the presented word ($L_{Aeq}$ 55 dB) at three noise levels ($L_{Aeq}$ 30, 40, 50 dB) and three reverberation times (0.5, 1.0, 1.5 s). Results showed that the residential space with noise level lower than equal to 50 dB ($L_{i,Fmax,AW}$) for jumping noise and 40 dB ($L_{Aeq}$) for road traffic, airborne, and drainage noise had speech intelligibility of 90 % and over and listening difficulty of 30 % and below. Speech intelligibility and listening difficulty for the aged sound source was shown to be 0 % ~ 5 % lower and 2 % ~ 20 % higher than those for the young sound source, respectively.

Prediction Method of Control Valve Noise (잔향실을 이용한 콘트롤 밸브 소음 예측 방법)

  • 이용봉;윤병로;박경암;이두희;유선학
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.8
    • /
    • pp.703-707
    • /
    • 2002
  • This paper proposes new method for predicting sound power emitted from the control valve and piping system. The sound power level measurement method using the reverberation chamber is much easy to apply in the field compared to the method using the anechoic chamber. Measured sound power was used to determine the coefficients of the equation predicting sound power level. The noise prediction equation was developed at relative flow coefficient, 0.11. The sound power level predicted is in good agreement with the measured value. Proposed method can be used to express the noise characteristics of the control valves.

The Effect of Aerated Concrete containing Foam Glass Aggregate on the Floor Impact Sound Insulation (발포유리 혼합기포 콘크리트의 바닥충격음 차단성능 영향에 관한 연구)

  • Yun, Chang-Yeon;Jeong, Jeong-Ho;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.414-422
    • /
    • 2013
  • As structure-borne sound, the floor impact sound is one of the serious noises in residential building. Most of heating system applied to the typical Korean residential building is floor heating system which is called ondol. The ondol usually consists of finishing material, mortar with heating coil, light-weight aerated concrete and reinforced concrete. This study focused on the isolation of heavy-weight impact sound and modification of mortar and light-weight aerated concrete. Specifically the glass foam aggregate was added on light-weight aerated concrete. Also, water-cement ratio and amount of cement on mortar were revised. The sound pressure level of heavy-weight impact was measured in reverberation chamber using both bang-machine and impact ball. The size of specimen was 1 m by 1 m. Substitution ratio of glass foam aggregate on light-weight aerated concrete shows relationship with heavy-weight impact sound pressure level. In addition, heavy-weight impact sound pressure level was decreased with increment of water-cement ratio and amount of cement on mortar.

Measure of Effectiveness Analysis of Active SONAR for Detection (능동소나 탐지효과도 분석)

  • Park, Ji-Sung;Kim, Jea-Soo;Cho, Jung-Hong;Kim, Hyoung-Rok;Shin, Kee-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.118-129
    • /
    • 2013
  • Since the obstacles and mines are of the risk factors for operating ships and submarines, the active sonar system is inevitably used to avoid the hazards in ocean environment. In this paper, modeling and simulation algorithm is used for active sonar systemto quantify the measure of mission achievability, which is known as Measure of Effectiveness(MOE), specifically for detection in this study. MOE for detection is directly formulated as a Cumulative Detection Probability(CDP) calculated from Probability of Detection(PD) in range and azimuth. The detection probability is calculated from Transmission Loss(TL) and the sonar parameters such asDirectivity Index (DI) calculated from the shape of transmitted and received array, steered beam patterns, and Reverberation Level (RL). The developed code is applied to demonstrating its applicability.

Detection Range Estimation Algorithm for Active SONAR System and Application to the Determination of Optimal Search Depth (능동 소나 체계에서의 표적 탐지거리 예측 알고리즘과 최적 탐지깊이 결정에의 응용)

  • 박재은;김재수
    • Journal of Ocean Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.62-70
    • /
    • 1994
  • In order to estimate the detection range of a active SONAR system, the SONAR equation is commonly used. In this paper, an algorithm to calculate detection range in active SONAR system as function of SONAR depth and target depth is presented. For given SONAR parameters and environment, the transmission loss and background level are found, signal excess is computed. Using log-normal distribution, signal excess is converted to detection probability at each range. Then, the detection range is obtained by integrating the detection probability as function of range for each depth. The proposed algorithm have been applied to the case of omni-directional source with center frequency 30Hz for summer and winter sound profiles. It is found that the optimal search depth is the source depth since the detection range increase at source depth where the signal excess is maximized.

  • PDF

Minimization of Shadow Zone for Hull Mounted Sonar (선체 고정형 소나의 음영 구역 최소화)

  • Lim, Se-Han;Han, Yun-Hoo;Jang, Chan-Joo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.211-217
    • /
    • 2010
  • This paper introduces the Hull Mounted Sonar Vertical Scanning(HMS Verscan) technique to overcome the limitation of target detection in short range shadow zone. Numerical experiments were done with the HMS Verscan taking advantage of the vertical beamforming technique for two-dimension hydrospace(range-depth). For numerical experiments, ray model and high-frequency monostatic reverberation model were used. HMS Verscan increased a sound pressure level at the short range shadow zone through reflections at the sea surface and seafloor. Inclusion of the boundary scattering improved target detection due to the sound reflected into the shadow zone.